Laminar two-phase boundary layers in natural convection film boiling of subcooled liquids.
Laminar two-phase boundary layer flow in film boiling, obtaining asymptotic solutions for low and high subcooled liquids
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Laminar two-phase boundary layer flow in film boiling, obtaining asymptotic solutions for low and high subcooled liquids
First of a kind high spatial and temporal resolution temperature measurements of Pressurized Water Reactor and Boiling Water Reactor simulated fuel pins (high heat flux cosine profile heaters) in annular rod type geometry during nucleate boiling, departure from nucleate boiling and re-wetting has been performed. Distributed fiber optic measurements of the cladding axial temperature with spatial resolutions down to 2.5 mm axially at up to three equally spaced azimuthal locations per rod have demonstrated the similarities and differences of the different accident tolerant fuel cladding materials. These experiments show the performance of accident tolerant cladding with a precise measurement of the location and evolution of dryout followed by the re-wetting phenomena (see supplementary time history of a critical heat flux event). Experimental parameters varied coolant mass fluxes from 1695 to 2712 kg/m 2 s, pressures from 10 to 20 MPa, and inlet subcooling from 10 to 55 °C. It was found that the coatings and different material have little effect on the value of the critical heat flux. Any discrepancies between the local critical heat flux verified among the cladding material are attributed to different departure from nucleate boiling phenomena captured during the experiment with the high-resolution optical fiber temperature data. Substantial differences in the performance of the different cladding material to survive a critical heat flux event were however observed by post-test X-ray and optical inspection. External evident damage and internal cracks to the simulated fuel pin having the bare zircaloy cladding were observed in regions associated with the occurrence of the critical heat flux for longer periods. Such damages were associated with zirconium oxidation, and not noticed on the Cr coated zircaloy or FeCrAl claddings. These results indicate that the use of FeCrAl or a Cr coated zircaloy as cladding in Pressurized Water Reactor and Boiling Water Reactor may increase the survivability of the cladding material for short transients.
Recently, heat transfer correlations based on liquid nitrogen (LN2) and liquid hydrogen (LH2) pipe quenching data were developed to improve the predictive accuracy of lumped node codes like SINDA/FLUINT and the Generalized Fluid System Simulation Program (GFSSP). After implementing these correlations into both programs, updated model runs showed strong improvement in LN2 pipe chilldown modeling but only modest improvement in LH2 modeling. Due to large differences in thermal and fluid properties between the two fluids, results indicated a need to develop a separate set of LH2-only correlations to improve the accuracy of the simulations. This paper presents a new set of two-phase convection heat transfer correlations based on LH2 pipe quenching data. A correlation to predict the bulk vapor temperature was developed after analysis showed that high amounts of thermal nonequilibrium of the liquid and vapor phases occurred during film boiling of LH2. Implemented in a numerical model, the new correlations achieve a mean absolute error of 19.5 K in the predicted wall temperature when compared to recent LH2 pipe chilldown data, an improvement of 40% over recent GFSSP predictions. This correlation set can be implemented in simulations of the transient LH2 chilldown process. Such simulations are useful for predicting the chilldown time and boil-off mass of LH2 for applications such as the transfer of LH2 from a ground storage tank to the rocket vehicle propellant tank, or through a rocket engine feedline during engine startup.
One dimensional flow model to correlate subcooled boiling pressure drop in circular tubes with constant heat flux
In the dispersed flow film boiling regime (DFFB), which exists under post-LOCA (loss-of-coolant accident) conditions in pressurized water reactors (PWRs), there is a complex interplay between droplet dynamics and turbulence in the surrounding steam. Experiments have accredited particular significance to droplet collision with the spacer-grids and mixing vane structures and their consequent positive feedback to the heat transfer recorded in the immediate downstream vicinity. Enabled by high-performance computing (HPC) systems and a massively parallel finite element-based flow solver—PHASTA (Parallel Hierarchic Adaptive Stabilized Transient Analysis)—this work presents high fidelity interface capturing, two-phase, adiabatic simulations in a PWR sub-channel with spacer grids and mixing vanes. Selected flow conditions for the simulations are informed by the experimental data found in the literature, including the steam Reynolds number and collision Weber number (Wec={40,80}), and are characteristic of the DFFB regime. Data were collected from the simulations at an unprecedented resolution, which provides detailed insights into the continuous phase turbulence statistics, highlighting the effects of the presence of droplets and the comparative effect of different Weber numbers on turbulence in the surrounding steam. Further, axial evolution of droplet dynamics was analyzed through cross-sectionally averaged quantities, including droplet volume, surface area and Sauter mean diameter (SMD). The downstream SMD values agree well with the existing empirical correlations for the selected range of Wec. The high-resolution data repository from the simulations herein is expected to be of significance to guide model development for system-level thermal hydraulic codes.
Tests of cryogenic chilldown in a vertical stainless steel tube are simulated using computational fluid dynamics (CFD). Subcooled liquid nitrogen enters the room-temperature tube at one end, resulting in film boiling and eventual quenching of the tube walls. A CFD-based modeling framework employing the mixture multiphase model has been developed to simulate this chilldown process and applied to validate it against experimental data. Extensive sensitivity studies have been performed to create a consistent modeling framework, and a two test conditions are simulated to test the modeling capability. The importance of the rewetting temperature and its relation to the foam limit temperature is discussed and is considered in the CFD model. The presented results demonstrate a qualitatively consistent representation of the film boiling and quenching regime. However, the quantitative accuracy of the simulations varies with the test conditions. Simulated vapor volume fraction distributions are also presented, although the current lack of experimental volume fraction data does not permit a comparison.
Tests of cryogenic chilldown in a vertical stainless-steel tube are simulated using computational fluid dynamics (CFD). Subcooled liquid nitrogen enters a room-temperature tube at one end, resulting in film boiling and eventual quenching of the tube walls. A CFDbased modeling framework employing the mixture multiphase model was developed to simulate this chilldown process and was applied to validate it against experimental data. Extensive sensitivity studies have been performed to create a consistent modeling framework, and a range of test conditions are simulated to assess the modeling capability. The importance of the rewetting temperature and its relation to the foam limit temperature is discussed and considered in the CFD framework. The presented results demonstrate a qualitatively consistent representation of the film boiling and quenching regime. However, the quantitative accuracy of the simulations varies with the test conditions. In addition, simulated distributions of the vapor volume fraction are presented, but the current lack of experimental volume fraction data prevents comparisons.
Tests of cryogenic chilldown in a vertical stainless-steel tube are simulated using computational fluid dynamics (CFD). Subcooled liquid nitrogen enters a room-temperature tube at one end, resulting in film boiling and eventual quenching of the tube walls. A CFDbased modeling framework employing the mixture multiphase model was developed to simulate this chilldown process and was applied to validate it against experimental data. Extensive sensitivity studies have been performed to create a consistent modeling framework, and a range of test conditions are simulated to assess the modeling capability. The importance of the rewetting temperature and its relation to the foam limit temperature is discussed and considered in the CFD framework. The presented results demonstrate a qualitatively consistent representation of the film boiling and quenching regime. However, the quantitative accuracy of the simulations varies with the test conditions. In addition, simulated distributions of the vapor volume fraction are presented, but the current lack of experimental volume fraction data prevents comparisons.
The coupling influence of airflow and temperature on the two-dimensional distribution of the film resulted from fuel spray impinging on a horizontal flat wall was studied with experiments. The horizontal airflow direction was perpendicular to the vertical axis of the injection spray. The results show that, as air velocity increases, the film shape turns from a circle to an oblong. As wall temperature increases, the film area shrinks. Film thickness decreases as wall temperature or air velocity increases. The boiling point of the fuel is an important temperature to affect the film area and the film thickness. Film center moves more far away in the downstream direction as air velocity increases. For a certain air velocity, film center moves less far away as wall temperature increases. (author)
This report describes the Consortium for Advanced Simulation of Light Water Reactors (CASL) work conducted for completion of the Thermal Hydraulics Methods (THM) Level 3 milestone THM.CFD.P13.03: High Fidelity BWR Fuel Simulation. High fidelity computational fluid dynamics (CFD) simulation for Boiling Water Reactor (BWR) was conducted to investigate the applicability and robustness performance of BWR closures. As a preliminary study, a CFD model with simplified Ferrule spacer grid geometry of NUPEC BWR Full-size Fine-mesh Bundle Test (BFBT) benchmark has been implemented. Performance of multiphase segregated solver with baseline boiling closures has been evaluated. Although the mean values of void fraction and exit quality of CFD result for BFBT case 4101-61 agreed with experimental data, the local void distribution was not predicted accurately. The mesh quality was one of the critical factors to obtain converged result. The stability and robustness of the simulation was mainly affected by the mesh quality, combination of BWR closure models. In addition, the CFD modeling of fully-detailed spacer grid geometry with mixing vane is necessary for improving the accuracy of CFD simulation.
Single-pressure absorption systems incorporate bubble-pump generators (BPGs) for refrigerant separation and passive fluid circulation. In conventional spot-heated BPGs, heat is transferred over a small area, requiring high source temperatures. Distributed-heated BPGs receive thermal input over most of the component surface, enabling low temperature operation. In this investigation, a Volume-of-Fluid phase-change simulation formulation is developed and validated. Here this approach is applied to the evaporating Taylor flow pattern in distributed-heated BPGs. A 2-D axisymmetric simulation is performed, which yields detailed information about the developing heat transfer and two-phase flow phenomena. Results are used to assess predicted trends and sub-models from a 1-D segmented BPG model. Close agreement is obtained between segmented model and simulation results for bubble rise velocity (5–7% deviation), bubble and slug lengths, void fraction (3%), and hydrodynamic pressure drop (18%). Specifying average Taylor bubble lengths from the simulation as an input to the segmented model reduces hydrodynamic pressure drop deviation to 6%. Simulated flow-evaporation heat transfer coefficients are significantly higher than those predicted using analytic models from the literature. A new flow evaporation heat transfer correlation that accounts for developing slug flow effects is proposed, and yields close agreement with simulation results for heat transfer coefficient (AAD = 11%) and overall heat transfer rate (2%). Overall, this investigation provides validation for a distributed-heated BPG modeling approach, which can enable passive refrigeration for diverse applications.
The Liquid Argon Purity Demonstrator was an R&D test stand designed to determine if electron drift lifetimes adequate for large neutrino detectors could be achieved without first evacuating the cryostat. We describe here the cryogenic system, its operations, and the apparatus used to determine the contaminant levels in the argon and to measure the electron drift lifetime. The liquid purity obtained by this system was facilitated by a gaseous argon purge. Additionally, gaseous impurities from the ullage were prevented from entering the liquid at the gas-liquid interface by condensing the gas and filtering the resulting liquid before returning to the cryostat. The measured electron drift lifetime in this test was greater than 6 ms, sustained over several periods of many weeks. Measurements of the temperature profile in the argon, to assess convective flow and boiling, were also made and are compared to simulation.
Parker Precision Cooling Business Unit was awarded a Department of Energy grant (DE-EE0000412) to support the DOE-ITP goal of reducing industrial energy intensity and GHG emissions. The project proposed by Precision Cooling was to accelerate the development of a cooling technology for high heat generating electronics components. These components are specifically related to power electronics found in power drives focused on the inverter, converter and transformer modules. The proposed cooling system was expected to simultaneously remove heat from all three of the major modules listed above, while remaining dielectric under all operating conditions. Development of the cooling system to meet specific customer's requirements and constraints not only required a robust system design, but also new components to support long system functionality. Components requiring further development and testing during this project included pumps, fluid couplings, cold plates and condensers. All four of these major categories of components are required in every Precision Cooling system. Not only was design a key area of focus, but the process for manufacturing these components had to be determined and proven through the system development.
Closed loop low pressure forced flow convective boiling system analyzed for instabilities due to feed system/boiler interaction
Explore the source record for details and available documents.
A multi-purpose thermal insulation test apparatus is used for testing insulation materials, or other components. The test apparatus is a fluid boil-off calorimeter system for calibrated measurement of the apparent thermal conductivity (k-value) of a specimen material at a fixed vacuum level. The apparatus includes an inner vessel for receiving a fluid with a normal boiling point below ambient temperature, such as liquid nitrogen, enclosed within a vacuum chamber. A cold mass assembly, including the inner vessel and thermal guards, is suspended from the top of the vacuum chamber. Handling tools attach to the cold mass assembly for convenient manipulation of the assembly and for the installation or wrapping of insulation test materials. Liquid nitrogen is typically supplied to the inner vessel using a fill tube with funnel. A single port through the top of the vacuum chamber facilitates both filling and venting. Aerogel composite stacks with reflective films are fastened to the top and the bottom of the inner vessel as thermal guards. The comparative k-value of the insulation material is determined by measuring the boil-off flow rate of gas, the temperature differential across the insulation thickness, and the dimensions (length and diameters) of the test specimen.