Search NASA⌕ Search

SEARCH · Search NASA

Results for “fluorescent imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Fluorescent Applications to Crystallization

By covalently modifying a subpopulation, less than or equal to 1%, of a macromolecule with a fluorescent probe, the labeled material will add to a growing crystal as a microheterogeneous growth unit. Labeling procedures can be readily incorporated into the final stages of purification, and tests with model proteins have shown that labeling u to 5 percent of the protein molecules does not affect the X-ray data quality obtained . The presence of the trace fluorescent label gives a number of advantages. Since the label is covalently attached to the protein molecules, it "tracks" the protein s response to the crystallization conditions. The covalently attached probe will concentrate in the crystal relative to the solution, and under fluorescent illumination crystals show up as bright objects against a darker background. Non-protein structures, such as salt crystals, do not show up under fluorescent illumination. Crystals have the highest protein concentration and are readily observed against less bright precipitated phases, which under white light illumination may obscure the crystals. Automated image analysis to find crystals should be greatly facilitated, without having to first define crystallization drop boundaries as the protein or protein structures is all that shows up. Fluorescence intensity is a faster search parameter, whether visually or by automated methods, than looking for crystalline features. Preliminary tests, using model proteins, indicates that we can use high fluorescence intensity regions, in the absence of clear crystalline features or "hits", as a means for determining potential lead conditions. A working hypothesis is that more rapid amorphous precipitation kinetics may overwhelm and trap more slowly formed ordered assemblies, which subsequently show up as regions of brighter fluorescence intensity. Experiments are now being carried out to test this approach using a wider range, of proteins. The trace fluorescently labeled crystals will also emit with sufficient intensity to aid in the automation of crystal alignment using relatively low cost optics, further increasing throughput at synchrotrons.

Pusey, Marc L.↗

Development of image processing techniques for applications in flow visualization and analysis

A comparison between two flow visualization studies of an axi-symmetric circular jet issuing into still fluid, using two different experimental techniques, is described. In the first case laser induced fluorescence is used to visualize the flow structure, whilst smoke is utilized in the second. Quantitative information was obtained from these visualized flow regimes using two different digital imaging systems. Results are presented of the rate at which the jet expands in the downstream direction and these compare favorably with the more established data.

Disimile, Peter J.↗

Preliminary measurements of mesospheric OH X 2Pi by ISO on Atlas 1

The Imaging Spectrometric Observatory (ISO) carried by the Atlas 1 mission conducted observations of the resonance fluorescence of the OH radical, on whose bases a density profile has been determined at 70-80 km altitude. OH observations were conducted during most of the dayside phases during the mission, covering much of the Northern Hemisphere to 57 deg N latitude. Attention is given to results from an observation at 39 deg N, where OH densities rapidly decreased above 80 km.

Morgan, M. F.↗

Concentration Measurements in a Cold Flow Model Annular Combustor Using Laser Induced Fluorescence

A nonintrusive concentration measurement method is developed for determining the concentration distribution in a complex flow field. The measurement method consists of marking a liquid flow with a water soluble fluorescent dye. The dye is excited by a two dimensional sheet of laser light. The fluorescent intensity is shown to be proportional to the relative concentration level. The fluorescent field is recorded on a video cassette recorder through a video camera. The recorded images are analyzed with image processing hardware and software to obtain intensity levels. Mean and root mean square (rms) values are calculated from these intensity levels. The method is tested on a single round turbulent jet because previous concentration measurements have been made on this configuration by other investigators. The previous results were used to comparison to qualify the current method. These comparisons showed that this method provides satisfactory results. 'Me concentration measurement system was used to measure the concentrations in the complex flow field of a model gas turbine annular combustor. The model annular combustor consists of opposing primary jets and an annular jet which discharges perpendicular to the primary jets. The mixing between the different jet flows can be visualized from the calculated mean and rms profiles. Concentration field visualization images obtained from the processing provide further qualitative information about the flow field.

Morgan, Douglas C.↗

Ultra-Sensitive Photoreceiver Boosts Data Transmission

NASA depends on advanced, ultra-sensitive photoreceivers and photodetectors to provide high-data communications and pinpoint image-detection and -recognition capabilities from great distances. In 2003, Epitaxial Technologies LLC was awarded a Small Business Innovation Research (SBIR) contract from Goddard Space Flight Center to address needs for advanced sensor components. Epitaxial developed a photoreciever capable of single proton sensitivity that is also smaller, lighter, and requires less power than its predecessor. This receiver operates in several wavelength ranges; will allow data rate transmissions in the terabit range; and will enhance Earth-based missions for remote sensing of crops and other natural resources, including applications for fluorescence and phosphorescence detection. Widespread military and civilian applications are anticipated, especially through enhancing fiber optic communications, laser imaging, and laser communications.

Source record↗

NASA Tech Briefs, April 2009

Topics covered include: Direct-Solve Image-Based Wavefront Sensing; Use of UV Sources for Detection and Identification of Explosives; Using Fluorescent Viruses for Detecting Bacteria in Water; Gradiometer Using Middle Loops as Sensing Elements in a Low-Field SQUID MRI System; Volcano Monitor: Autonomous Triggering of In-Situ Sensors; Wireless Fluid-Level Sensors for Harsh Environments; Interference-Detection Module in a Digital Radar Receiver; Modal Vibration Analysis of Large Castings; Structural/Radiation-Shielding Epoxies; Integrated Multilayer Insulation; Apparatus for Screening Multiple Oxygen-Reduction Catalysts; Determining Aliasing in Isolated Signal Conditioning Modules; Composite Bipolar Plate for Unitized Fuel Cell/Electrolyzer Systems; Spectrum Analyzers Incorporating Tunable WGM Resonators; Quantum-Well Thermophotovoltaic Cells; Bounded-Angle Iterative Decoding of LDPC Codes; Conversion from Tree to Graph Representation of Requirements; Parallel Hybrid Vehicle Optimal Storage System; and Anaerobic Digestion in a Flooded Densified Leachbed.

Source record↗

The Effect of Impingement on Transitional Behavior in Underexpanded Jets

An investigation into the development of flow unsteadiness in impinging axisymmetric underexpanded jets has been conducted at NASA Langley Research Center. The study has examined the effect of an impingement target placed at various distances and angles on transitional behavior of such jets. Two nozzles, with exit Mach numbers of 1.0 and 2.6, were used in this investigation. Planar laser-induced fluorescence of nitric oxide (NO PLIF) has been used to identify flow unsteadiness and to image transitional and turbulent flow features. Measurements of the location of the onset of various degrees of unsteady flow behavior have been made using these PLIF images. Both qualitative and quantitative comparisons are presented to demonstrate the observed effects of impingement and flow parameters on the process of the transition to turbulence. The presence of the impingement target was found to significantly shorten the distance to transition to turbulence by up to a factor of approximately three, with closer targets resulting in slightly shorter distance to transition and turbulence. The location at which the flow first exhibits unsteadiness was found to have a strong dependence on the presence and location of key flow structures. This paper presents quantitative results on transition criteria for free and impinging jets.

Inman, Jennifer A.↗

Simplified Microarray Technique for Identifying mRNA in Rare Samples

Two simplified methods of identifying messenger ribonucleic acid (mRNA), and compact, low-power apparatuses to implement the methods, are at the proof-of-concept stage of development. These methods are related to traditional methods based on hybridization of nucleic acid, but whereas the traditional methods must be practiced in laboratory settings, these methods could be practiced in field settings. Hybridization of nucleic acid is a powerful technique for detection of specific complementary nucleic acid sequences, and is increasingly being used for detection of changes in gene expression in microarrays containing thousands of gene probes. A traditional microarray study entails at least the following six steps: 1. Purification of cellular RNA, 2. Amplification of complementary deoxyribonucleic acid [cDNA] by polymerase chain reaction (PCR), 3. Labeling of cDNA with fluorophores of Cy3 (a green cyanine dye) and Cy5 (a red cyanine dye), 4. Hybridization to a microarray chip, 5. Fluorescence scanning the array(s) with dual excitation wavelengths, and 6. Analysis of the resulting images. This six-step procedure must be performed in a laboratory because it requires bulky equipment.

Almeida, Eduardo↗

Three Component Velocity and Acceleration Measurement Using FLEET

The femtosecond laser electronic excitation and tagging (FLEET) method has been used to measure three components of velocity and acceleration for the first time. A jet of pure N2 issuing into atmospheric pressure air was probed by the FLEET system. The femtosecond laser was focused down to a point to create a small measurement volume in the flow. The long-lived lifetime of this fluorescence was used to measure the location of the tagged particles at different times. Simultaneous images of the flow were taken from two orthogonal views using a mirror assembly and a single intensified CCD camera, allowing two components of velocity to be measured in each view. These different velocity components were combined to determine three orthogonal velocity components. The differences between subsequent velocity components could be used to measure the acceleration. Velocity accuracy and precision were roughly estimated to be +/-4 m/s and +/-10 m/s respectively. These errors were small compared to the approx. 100 m/s velocity of the subsonic jet studied.

Danehy, Paul M.↗

Machine Learning Approaches to Data Reduction from the MapX X-ray Fluorescence Instrument for Detection of Biosignatures and Habitable Planetary Environments

The search for evidence of life or its processes involves the detection of biosignatures suggestive of extinct or extant life, or the determination that an environment either has or once had the potential to harbor life. In situ elemental imaging is useful in either case, since features on the mm to μm scale reveal geological processes which may indicate past or present habitability. The Mapping X-ray Fluorescence Spectrometer (MapX) is an in-situ instrument designed to identify these features on planetary surfaces. Here we present progress on instrument development, data analysis methods, and element quantification.

Walroth, Richard C.↗

Lunar and Planetary Science XXXVI, Part 15

Contents include the following: Impact Metamorphism of Subsurface Organic Matter on Mars: A Potential Source for Methane and Surface Alteration. Preliminary Study of Polygonal Impact Craters in Argyre Region, Mars. Geochemistry of the Dark Veinlets in the Granitoids from the Souderfjarden Impact Structure, Finland: Preliminary Results. An Experimental Method to Estimate the Chemical Reaction Rate in Vapor Clouds: An Application to the K/T Impact. Study of the Apollo 16 Landing Site: Re-Visit as a Standard Site for the SELENE Multiband Imager. First X-Ray Observation of Lunar Farside from Hayabusa X-Ray Spectrometer. Lunar X-Ray Fluorescence Spectrometry from SELENE Lunar Polar Orbiter. Origin and Thermal History of Lithic Materials in the Begaa LL3 Chondrite. Evidence of Normal Faulting and Dike Intrusion at Valles Marineris from Pit Crater Topography. Evidence of Tharsis-Radial Dike Intrusion in Southeast Alba Patera from MOLA-based Topography of Pit Crater Chains. Are They Really Intact? Evaluation of Captured Micrometeoroid Analogs by Aerogel at the Flyby Speed of Stardust. Numerical Simulations of Impactor Penetration into Ice-Over-Water Targets. A Probable Fluid Lava Flow in the Hebes Mensa (Mars) Studied by HRSC Images. New Drill-Core Data from the Lockne Crater, Sweden: The Marine Excavation and Ejection Processes, and Post-Impact Environment. Cross-Sectional Profile of Baltis Vallis Channel on Venus: Reconstruction from Magellan SAR Brightness Data.

Source record↗

Three-dimensional quantitative flow diagnostics

The principles, capabilities, and practical implementation of advanced measurement techniques for the quantitative characterization of three-dimensional flows are reviewed. Consideration is given to particle, Rayleigh, and Raman scattering; fluorescence; flow marking by H2 bubbles, photochromism, photodissociation, and vibrationally excited molecules; light-sheet volume imaging; and stereo imaging. Also discussed are stereo schlieren methods, holographic particle imaging, optical tomography, acoustic and magnetic-resonance imaging, and the display of space-filling data. Extensive diagrams, graphs, photographs, sample images, and tables of numerical data are provided.

Miles, Richard B.↗

Time Resolved Visualization of Liquid Jet Interaction With H2-Air Rotating Detonations Using MHz Rate Diesel PLIF

The characterization of the dynamic response of liquid jets to transient detonation wave passage is critical for optimization and modeling of liquid fueled rotating detonation combustors. In this work, a rotating detonation combustor (RDC) is operated on hydrogen and air to sustain stable detonation waves that acts as a detonation driver and interact in a one-way coupled manner with a single liquid fuel jet that propagates into the combustion chamber with cycle periods of ~ 250 μs. Diesel is utilized as a realistic fuel surrogate with higher aromatic compounds to enable fluorescence excitation, using the 355 nm thirdharmonic output of a burst-mode Nd:YAG laser, imaged at rates up to 1 MHz. By optimizing the technique to accommodate orders of magnitude variations in the fuel density throughout the injection process, the PLIF data enable quantitative measurements including the refill time, the relative recovery between liquid and gaseous jets and jet trajectory across various momentum flux ratio. As the passage of the detonation wave imparts significant changes in the momentum flux ratio, the qualitative liquid break-up process and spatial distribution varies significantly in time. As the injection system recovers ~ 70% of the cycle period and return to a quasi-steady position and allow comparisons with theoretical jet trajectories. These data, enabled by ultra-high-speed PLIF imaging, represent some of the first detailed measurements for quantifying the dynamic response and recovery of liquid jets exposed to periodic detonations in an operating RDC.

Propulsion↗

Quantitative density visualization in a transonic rotor

The flow in a two foot diameter transonic rotor has been visualized using a fluorescent gas, 2, 3 butanedione, as a tracer. The technique allows the three dimensional flow to be imaged as a set of distinct planes. Quantitative static density maps can be obtained after correcting the images for distortion and nonlinearities introduced by the illumination and imaging systems. The visualized flow is compared to data taken simultaneously by high frequency pressure transducers near the rotor entrance and exit planes.

Epstein, A. H.↗

Reduction and Analysis of Phosphor Thermography Data With the IHEAT Software Package

Detailed aeroheating information is critical to the successful design of a thermal protection system (TPS) for an aerospace vehicle. This report describes NASA Langley Research Center's (LaRC) two-color relative-intensity phosphor thermography method and the IHEAT software package which is used for the efficient data reduction and analysis of the phosphor image data. Development of theory is provided for a new weighted two-color relative-intensity fluorescence theory for quantitatively determining surface temperatures on hypersonic wind tunnel models; an improved application of the one-dimensional conduction theory for use in determining global heating mappings; and extrapolation of wind tunnel data to flight surface temperatures. The phosphor methodology at LaRC is presented including descriptions of phosphor model fabrication, test facilities and phosphor video acquisition systems. A discussion of the calibration procedures, data reduction and data analysis is given. Estimates of the total uncertainties (with a 95% confidence level) associated with the phosphor technique are shown to be approximately 8 to 10 percent in the Langley's 31-Inch Mach 10 Tunnel and 7 to 10 percent in the 20-Inch Mach 6 Tunnel. A comparison with thin-film measurements using two-inch radius hemispheres shows the phosphor data to be within 7 percent of thin-film measurements and to agree even better with predictions via a LATCH computational fluid dynamics solution (CFD). Good agreement between phosphor data and LAURA CFD computations on the forebody of a vertical takeoff/vertical lander configuration at four angles of attack is also shown. In addition, a comparison is given between Mach 6 phosphor data and laminar and turbulent solutions generated using the LAURA, GASP and LATCH CFD codes. Finally, the extrapolation method developed in this report is applied to the X-34 configuration with good agreement between the phosphor extrapolation and LAURA flight surface temperature predictions. The phosphor process outlined in the paper is believed to provide the aerothermodynamic community with a valuable capability for rapidly obtaining (4 to 5 weeks) detailed heating information needed in TPS design.

Merski, N. Ronald↗

Time Resolved Visualization of A Liquid Jet in an RDE Using MHz Rate Diesel PLIF

The characterization of the dynamic response of liquid jets to transient detonation wave passage is critical for optimization and modeling of liquid fueled rotating detonation combustors. In this work, a rotating detonation combustor (RDC) is operated on hydrogen and air to sustain stable detonation waves that acts as a detonation driver and interact in a one-way coupled manner with a single liquid fuel jet that propagates into the combustion chamber with cycle periods of ~ 250 μs. Diesel is utilized as a realistic fuel surrogate with higher aromatic compounds to enable fluorescence excitation, using the 355 nm third harmonic output of a burst-mode Nd:YAG laser, imaged at rates up to 1 MHz. By optimizing the technique to accommodate orders of magnitude variations in the fuel density throughout the injection process, the PLIF data enable quantitative measurements including the refill time, the relative recovery between liquid and gaseous jets and jet trajectory across various momentum flux ratio. As the passage of the detonation wave imparts significant changes in the momentum flux ratio, the qualitative liquid break-up process and spatial distribution varies significantly in time. As the injection system recovers ~ 70% of the cycle period and return to a quasi-steady position and allow comparisons with theoretical jet trajectories. These data, enabled by ultra-high-speed PLIF imaging, represent some of the first detailed measurements for quantifying the dynamic response and recovery of liquid jets exposed to periodic detonations in an operating RDC.

Propulsion↗

In-Field Diffuse Ultraviolet Spectroscopy and Imaging of the Stardust Sample Return Capsule

In-field diffuse Ultraviolet (UV) spectroscopy and imaging systems were developed for the purposes of evaluating the surface chemical composition of spacecraft thermal control coatings and materials. The investigation of these systems and the compilation of an associated UV reflectance and luminescence database were conducted using the Stardust Sample Return Capsule (SRC), located at the Johnson Space Center. Spectral responses of the surfaces of the Stardust forebody and aftbody in both reflectance and fluorescence modes were examined post-flight. In this paper, we report on two primary findings of in-field diffuse UV spectroscopy and imaging: (1) deduction of the thermal history of thermal control coatings of the forebody and (2) bond line variations in the aftbody. In the forebody, the thermal history of thermal control coatings may be deduced from the presence of particular semiconducting defect states associated with ZnO, a common emissivity constituent in thermal control coatings. A spatial dependence of this history was mapped for these regions. In the aftbody, luminescing defect states, associated with Si and SiO2 color centers were found along regions of bond variability.

Pugel, D. Elizabeth↗

Remote detection of OH

This is a remote measurement technique utilizing a XeCl excimer laser tuned to the Q sub 21 1 rotational transition of the 0-0, A-X band at 307.847 nm. A wavemeter is under development to monitor, on a pulse-to-pulse basis, both the laser lineshape and absolute wavelength. Fluorescence is detected with a multiple Fabry-Perot type filter with a spectral resolution on the order of 0.001 nm. This is tuned to the overlapping Q sub 2 2, Q sub 12 2, Q sub 2 3, and Q sub 12 3 rotational transitions at 308.986 nm. The fringe pattern from this filter is imaged using a discrete, multi-anode detector which has a photon gain of 10 to the 8th power. This permits the simultaneous monitoring of OH fluorescence, N2 and/or O2 rotational Raman scattering and broadband background levels. The use of three etalons in series provides sufficient rejection, approx. greater than 10 to the 10th power, against the laser radiation only 1.2 nm away.

Mcdermid, I. Stuart↗