Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Prospects for detecting C II emission during the epoch of reionization

We produce simulations of the atomic C ii line emission in large sky fields in order to determine the current and future prospects for mapping this line during the high-redshift epoch of reionization. We calculate the C ii line intensity, redshift evolution, and spatial fluctuations using observational relations between C ii emission and the galaxy star formation rate over the frequency range 200–300 GHz. We estimate an averaged intensity of I{sub C II}=(4±2)×10{sup 2} Jy sr{sup −1} in the redshift range z ∼ 5.3−8.5. Observations of the C ii emission in this frequency range will suffer contamination from emission lines at lower redshifts, in particular CO rotational lines. Using simulations, we estimated the CO contamination to be I{sub CO}≈10{sup 3} Jy sr{sup −1} (originating from galaxies at z < 2.5). Using detailed simulations of the C ii and CO emission across a range of redshifts, we generate maps as a function of angle and frequency, fully taking into account this resolution and light-cone effects. In order to reduce the foreground contamination, we find that we should mask galaxies below redshifts ∼2.5 with a CO(J:2–1) to CO(J:6–5) line flux density higher than 5× 10{sup −22} W m{sup −2} or an AB magnitude lower than m{sub K}=22. We estimate that the additional continuum contamination originating in emission from stars and in dust, free–free, free–bound, and two-photon emission in the interstellar medium is of the order of 10{sup 5} Jy sr{sup −1}, which is well above the expected C ii signal. We also consider the possibility of cross-correlating foreground lines with galaxy surveys in order to probe the intensity of the foregrounds. Finally, we discuss the expected constraints from two experiments capable of measuring the expected C ii power spectrum.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark matter axion search using a Josephson Traveling wave parametric amplifier

Here, we describe the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in an axion dark matter search. The operation of the JTWPA for a period of about two weeks achieved sensitivity to axion-like particle dark matter with axion–photon couplings above 10 -13 Ge V -1 over a narrow range of axion masses centered around 19.84 µeV by tuning the resonant frequency of the cavity over the frequency range of 4796.7–4799.5 MHz. The JTWPA was operated in the insert of the axion dark matter experiment as part of an independent receiver chain that was attached to a 0.56-l cavity. The ability of the JTWPA to deliver high gain over a wide (3 GHz) bandwidth has engendered interest from those aiming to perform broadband axion searches, a longstanding goal in this field.

47 OTHER INSTRUMENTATION↗

Piezoelectric accelerometers for ultrahigh temperature application

High temperature sensors are of major importance to aerospace and energy related industries. In this letter, a high temperature monolithic compression-mode piezoelectric accelerometer was fabricated using YCa{sub 4}O(BO{sub 3}){sub 3} (YCOB) single crystals. The performance of the sensor was tested as function of temperature up to 1000 deg. C and over a frequency range of 100-600 Hz. The accelerometer prototype was found to possess sensitivity of 2.4+-0.4 pC/g, across the measured temperature and frequency range, indicating a low temperature coefficient. Furthermore, the sensor exhibited good stability over an extended dwell time at 900 deg. C, demonstrating that YCOB piezoelectric accelerometers are promising candidates for high temperature sensing applications.

36 MATERIALS SCIENCE↗

Three Classes of Motion in the Dynamic Neutron-Scattering Susceptibility of a Globular Protein

A simplified description of the 295 K dynamics of a globular protein over a wide frequency range (1-1000 GHz) is obtained by combining neutron scattering of lysozyme with molecular dynamics simulation. The molecular dynamics simulation agrees quantitatively with experiment for both the protein and the hydration water and shows that, whereas the hydration water molecules subdiffuse, the protein atoms undergo confined motion decomposable into three distinct classes: localized diffusion, methyl group rotations, and jumps. Each of the three classes gives rise to a characteristic neutron susceptibility signal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dual frequency feed system for the CTS communications link characterization experiment

The developing, testing and installation of a dual frequency feed assembly were described. The feed has been designed to receive signals in the frequency range 11.7 to 12.2 GHz and transmit signals in the frequency range 14.12 GHz plus or minus 250 MHz. Complete performance data of the feed alone and installed in the 15 foot antenna is included herein. Drawings and descriptive information of the feed assembly are also given.

Gill, G. J.↗

Low-frequency magnetic fluctuation spectra in the magnetosheath and plasma depletion layer

Recent observations have delineated several different kinds of enhanced magnetic fluctuation spectra below the proton cyclotron frequency in the terrestrial magnetosheath. A model is presented that represents the variation of plasma parameters across the plasma depletion layer and into the magnetosheath proper. Using this model, we find that many of the properties of the observed spectra follow directly from the predictions of linear Vlasov instability theory. The observed progression of spectral features is a natural progression from mirror mode to merged (in frequency range) proton and He(2+) cyclotron modes to bifurcated (in frequency range) cyclotron modes as plasma convects earthward in the magnetosheath. The necessary change in dispersion surface topology from separated proton and He(2+) cyclotron surfaces at low beta to merged surfaces at high beta is described.

Denton, Richard E.↗

Overview of Integrated Random Vibration Testing of the NASA Orion Crew Survival Suit

The launch ascent and abort random vibration environments from NASA’s Orion spacecraft drove the need to test the NASA Orion Crew Survival Suit as an integrated system with exposure to the design levels. In order to properly characterize component responses, a series of integrated tests were designed to incorporate the interaction between a crew member, suit, seat, and the attenuation system. The first Development Test (2017) included human subjects, and was performed with early development seat and suit components, and low level inputs. It provided a baseline for frequency response and behavior of the integrated system. The next two tests, Development Test (2019) and Qualification Test (2020), used manikin surrogates to represent the crew member and increasing levels of component hardware fidelity in order to test to higher input levels. Testing was performed at NASA Johnson Space Center (JSC) and Kennedy Space Center (KSC) Vibration Labs and provided the input levels required to represent the ascent and abort vehicle profiles as well as recorded component response behavior from accelerometer instrumentation and high speed cameras. Inspection of the suit and related components showed that for all seat orientations, and input environments, no damage occurred. Additional pre and post-test checks confirmed the functionality of all suited hardware. Response data of the suited components generally showed heavy attenuation across most of the tested frequency range. Transmissibility plots showed some amplification of components at lower frequency ranges. Overall this series of integrated tests showed that 1) the use of surrogate manikins in the tests were adequate for representing crew in a vibration environment, 2) full vibration levels for ascent and abort were heavily attenuated in the suit components and were non-damaging, and 3) the suit and related components are qualified for the Orion random vibration environments.

Jeffrey D Suhey↗

Overview of Integrated Random Vibration Testing of the NASA Orion Crew Survival Suit

The launch ascent and abort random vibration environments from NASA’s Orion spacecraft drove the need to test the NASA Orion Crew Survival Suit as an integrated system with exposure to the design levels. In order to properly characterize component responses, a series of integrated tests were designed to incorporate the interaction between a crew member, suit, seat, and the attenuation system. The first Development Test (2017) included human subjects, and was performed with early development seat and suit components, and low level inputs. It provided a baseline for frequency response and behavior of the integrated system. The next two tests, Development Test (2019) and Qualification Test (2020), used manikin surrogates to represent the crew member and increasing levels of component hardware fidelity in order to test to higher input levels. Testing was performed at NASA Johnson Space Center (JSC) and Kennedy Space Center (KSC) Vibration Labs and provided the input levels required to represent the ascent and abort vehicle profiles as well as recorded component response behavior from accelerometer instrumentation and high speed cameras. Inspection of the suit and related components showed that for all seat orientations, and input environments, no damage occurred. Additional pre and post-test checks confirmed the functionality of all suited hardware. Response data of the suited components generally showed heavy attenuation across most of the tested frequency range. Transmissibility plots showed some amplification of components at lower frequency ranges. Overall this series of integrated tests showed that 1) the use of surrogate manikins in the tests were adequate for representing crew in a vibration environment, 2) full vibration levels for ascent and abort were heavily attenuated in the suit components and were non-damaging, and 3) the suit and related components are qualified for the Orion random vibration environments.

Jeffrey Suhey↗

NEUTRON STAR RADIUS MEASUREMENT WITH THE QUIESCENT LOW-MASS X-RAY BINARY U24 IN NGC 6397

This paper reports the spectral and timing analyses of the quiescent low-mass X-ray binary (qLMXB) U24 observed during five archived Chandra/ACIS exposures of the nearby globular cluster NGC 6397, for a total of 350 ks. We find that the X-ray flux and the parameters of the hydrogen atmosphere spectral model are consistent with those previously published for this source. On short timescales, we find no evidence of aperiodic intensity variability, with 90% confidence upper limits during five observations ranging between <8.6% rms and <19% rms, in the 0.0001-0.1 Hz frequency range (0.5-8.0 keV); and no evidence of periodic variability, with maximum observed powers in this frequency range having a chance probability of occurrence from a Poisson-deviated light curve in excess of 10%. We also report the improved neutron star (NS) physical radius measurement, with statistical accuracy of the order of {approx}10%: R{sub NS} = 8.9{sup +0.9}{sub -0.6} km for M{sub NS} = 1.4 M{sub sun}. Alternatively, we provide the confidence regions in mass-radius space as well as the best-fit projected radius R{sub {infinity}} = 11.9{sup +1.0}{sub -0.8} km, as seen by an observer at infinity. The best-fit effective temperature, kT{sub eff} = 80{sup +4}{sub -5} eV, is used to estimate the NS core temperature which falls in the range T{sub core} = (3.0-9.8) x 10{sup 7} K, depending on the atmosphere model considered. This makes U24 the third most precisely measured NS radius among qLMXBs, after those in {omega} Cen and M13.

79 ASTRONOMY AND ASTROPHYSICS↗

Robust metal-ceramic coaxial cable sensors for distributed temperature monitoring in fossil energy power systems

The project aims to develop a new type of low cost, robust metal-ceramic coaxial cable (MCCC) Fabry-Pérot interferometer (FPI) sensor and demonstrate the capability of cascading a series of FPI sensing points in a single MCCC for real-time distributed monitoring of temperature up to 1000°C. The technical accomplishments of this project include: (i) development of metal and ceramic materials for fabricating the MCCC suitable for use in high temperature (up to 1000oC) fossil fuel, (ii) design, construction and test of single point MCCC-FPI sensors for high temperature measurement at deviation within ±2.7%, (iv) demonstration of the MCCC-FPI sensors for real-time distributed temperature measurement with desired sensitivity, spatial resolution, stability, and response speed that are important to practical applications, and (v) development of a novel MCCC-FPI sensor platform for measuring high frequency dielectric constants for solids and liquids as function of temperature. Single point MCCC-FPI sensors are fabricated based on the FPI parameters, including the relationship between reflector width and reflectance as well as the inter-reflector distance for a FPI, estimated by model calculations. MCCC-FPI sensors have been made using insulators of packed ceramic powders, ceramic tubes, and air or inert gases; outer conductors of various metal tubes; inner conductors of wires of the same metal materials as the tubes used; and reflectors of dense ceramic discs, casted ceramic discs and air gaps. The insulator, conductor and reflector materials are investigated for their thermal, chemical, and structural stabilities under temperatures up to 1000°C in simulated coal-derived syngas. Based on the experimental findings, alumina tube and discs, and stainless steel tube and wire are selected for reflector, insulator and outer and inner conductors, respectively. Air or inert gases are found to be useful for reflectors (in the form of narrow groves) or insulators (in the form of empty chamber cavity between ceramic discs) in construction of MCCC-FPI sensors. Single point MCCC-FPI sensors have been fabricated using stainless steel as conductors, dense α-alumina tubes as dielectric insulators, and two air gaps in the insulator as reflectors. The MCCC-FPI sensor with air gap reflectors has been demonstrated for measuring temperature between 200 and 500°C using microwave as sensing signal in a frequency range of 2 – 8 GHz. The temperature measurement is achieved by monitoring the frequency shift (Δƒ) of a selected resonant peak of the microwave interferogram reflected from the pair of air gap reflectors. The MCCC-FPI sensor exhibited excellent linear temperature-dependence for Δƒ, good accuracy (deviation ±2.7%), and reasonable response speed (<180 s for stabilization). Thermal drifting of the sensing signal was also rather minimal for the MCCC-FPI sensors after operating for more than one week at around 500oC. MCCC-FPI sensors with each containing 2 or 3 pairs of reflectors (i.e. 2 or 3 FPIs in a single cable) have been fabricated and demonstrated for distributed temperature measurement between 250 and 550°C in a microwave frequency range of 3-6 GHz. The measurement is achieved by monitoring the frequency shift of a selected resonant peak of the reflected microwave interferogram, which is obtained by the join-time-domain signal processing method. The results demonstrate that the FPI sensing points in both the three-point and two-point MCCC sensors can measure distributed high temperature with good reproducibility and consistency in multiple runs of measurement tests. The sensor signal displays excellent linear dependence between temperature and the corresponding frequency shift. The 2-point and 3-point MCCC-FPI sensors also exhibit fast response to environmental temperature changes. A three-point MCCC-FPI sensor has been further examined for temperature measurement up to 1000°C for multiple heating-cooling cycles and the results prove that the sensor is suitable for distributed temperature measurement up to 1000°C. MCCC-FPI sensors with more than 4 FPIs point in a single line are made in two structures: the first uses alumina tube as insulation and air gaps as reflectors; and the second uses air chamber as insulation and complete circular alumina discs (2 mm-thick) as reflectors. MCCC-FPIs in neither of the two structures are able to exceed four FPIs in a cable because the reflections from the FPIs are too strong for the microwave to transmit through >4 FPIs over a long distance. Specially shaped alumina discs made by removing parts of the circular discs are found to decrease the microwave reflectance because of reduced reflection areas. However, the smallest reflectance (in terms of percentage of the incident signal) obtained in this work is as high as 7.5%, which is still too large to construct more than 10 FPIs in a single MCCC. Nevertheless, the feasibility of the proposed multipoint MCCC-FPI has been demonstrated using air insulation and 2 mm-thick low-ε r Teflon discs as reflectors on a 2 m-long cable containing 10 FPIs (with reflectance <5% on each FPI). These results indicate that the contrast of dielectric constant between the insulation and reflector has a more significant impact on the reflectance. Thus, future research efforts should also be directed to developing ceramic materials (dense or porous) with low dielectric constant values which, when used as insulation or reflector, can realize large numbers of FPIs in a single cable over a long distance. To assist the development of high temperature dielectric materials, a novel MCCC-FPI sensor platform is developed and successfully demonstrated for measuring high frequency dielectric constants for fluids, packed dielectric solids, and ceramic tube materials and determining ε r dependencies on temperature and chemical composition, etc..

36 MATERIALS SCIENCE↗

Detection of electromagnetic waves using charged MEMS structures

We describe micromechanical structures that are capable of sensing both electrostatic fields and electromagnetic fields over a wide frequency range. Typically, sensing of electromagnetic waves is achieved with electrically conducting antennas, which despite the many advantages do not exhibit high sensitivity over a broad frequency range. An important aspect of our present work is that, in contrast to traditional antennas, the dimensions of micromechanical oscillators sensitive to electromagnetic waves can be much smaller than the wavelength. We characterized the micromechanical oscillators and measured responses to electric fields and estimated the performance limits by evaluating the signal-to-noise ratio theoretically and experimentally.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wobbling mode in {sup 167}Ta

The collective wobbling mode, the strongest signature for the rotation of a triaxial nucleus, has previously been seen only in a few Lu isotopes in spite of extensive searches in nearby isotopes. A sequence of transitions in the N=94 {sup 167}Ta nucleus exhibiting features similar to those attributed to the wobbling bands in the Lu nuclei has now been found. This band feeds into the {pi}i{sub 13/2} band at a relative energy similar to that seen in the established wobbling bands and its dynamic moment of inertia and alignment properties are nearly identical to the i{sub 13/2} structure over a significant frequency range. Given these characteristics, it is likely that the wobbling mode has been observed for the first time in a nucleus other than Lu, making this collective motion a more general phenomenon.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Temperature dependence of mechanical stiffness and dissipation in ultrananocrystalline diamond films grown by the HFCVD techinque.

We have characterized mechanical properties of ultrananocrystalline diamond (UNCD) thin films grown using the hot filament chemical vapor deposition (HFCVD) technique at 680 C, significantly lower than the conventional growth temperature of -800 C. The films have -4.3% sp{sup 2} content in the near-surface region as revealed by near edge x-ray absorption fine structure spectroscopy. The films, -1 {micro}m thick, exhibit a net residual compressive stress of 370 {+-} 1 MPa averaged over the entire 150 mm wafer. UNCD microcantilever resonator structures and overhanging ledges were fabricated using lithography, dry etching, and wet release techniques. Overhanging ledges of the films released from the substrate exhibited periodic undulations due to stress relaxation. This was used to determine a biaxial modulus of 838 {+-} 2 GPa. Resonant excitation and ring-down measurements in the kHz frequency range of the microcantilevers were conducted under ultrahigh vacuum (UHV) conditions in a customized UHV atomic force microscope system to determine Young's modulus as well as mechanical dissipation of cantilever structures at room temperature. Young's modulus is found to be 790 {+-} 30 GPa. Based on these measurements, Poisson's ratio is estimated to be 0.057 {+-} 0.038. The quality factors (Q) of these resonators ranged from 5000 to 16000. These Q values are lower than theoretically expected from the intrinsic properties of diamond. The results indicate that surface and bulk defects are the main contributors to the observed dissipation in UNCD resonators.

36 MATERIALS SCIENCE↗

Use of Frequency Response Metrics to Assess the Planning and Operating Requirements for Reliable Integration of Variable Renewable Generation

An interconnected electric power system is a complex system that must be operated within a safe frequency range in order to reliably maintain the instantaneous balance between generation and load. This is accomplished by ensuring that adequate resources are available to respond to expected and unexpected imbalances and restoring frequency to its scheduled value in order to ensure uninterrupted electric service to customers. Electrical systems must be flexible enough to reliably operate under a variety of"change" scenarios. System planners and operators must understand how other parts of the system change in response to the initial change, and need tools to manage such changes to ensure reliable operation within the scheduled frequency range. This report presents a systematic approach to identifying metrics that are useful for operating and planning a reliable system with increased amounts of variable renewable generation which builds on existing industry practices for frequency control after unexpected loss of a large amount of generation. The report introduces a set of metrics or tools for measuring the adequacy of frequency response within an interconnection. Based on the concept of the frequency nadir, these metrics take advantage of new information gathering and processing capabilities that system operators are developing for wide-area situational awareness. Primary frequency response is the leading metric that will be used by this report to assess the adequacy of primary frequency control reserves necessary to ensure reliable operation. It measures what is needed to arrest frequency decline (i.e., to establish frequency nadir) at a frequency higher than the highest set point for under-frequency load shedding within an interconnection. These metrics can be used to guide the reliable operation of an interconnection under changing circumstances.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Parametric Decay of Pump Waves into two Linear Modes in SINP MaPLE Device

Parametric decay of incident waves of ion cyclotron frequency range into linear modes is observed in experiment performed in the SINP MaPLE device where nitrogen plasma produced by ECR discharge. Along with a mode in drift wave frequency range, sideband of the incident waves are observed when amplitude of the exciter signal goes above a threshold value. Sideband of the second harmonic is also seen. Preliminary studies point towards excitation of ion Bernstein wave. Details of the experimental results are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SCALER MODE OF THE AUGER OBSERVATORY AND SUNSPOTS

Recent data from the Auger Observatory on low-energy secondary cosmic ray particles are analyzed to study temporal correlations together with data on the daily sunspot numbers and neutron monitor data. Standard spectral analysis demonstrates that the available data show 1/f {sup {beta}} fluctuations with {beta} Almost-Equal-To 1 in the low-frequency range. All data behave like Brownian fluctuations in the high-frequency range. The existence of long-range correlations in the data was confirmed by detrended fluctuation analysis. The real data confirmed the correlation between the scaling exponent of the detrended analysis and the exponent of the spectral analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Toroidal modeling of Alfvén eigenmodes excited by runaway electrons in DIII-D and ITER

The non-perturbative MHD-kinetic hybrid code MARS-K (Liu et al 2014 Phys. Plasmas 21 056105) is updated to include relativistic effects for kinetic fast particles, enabling the code to model excitation of Alfvén eigenmodes (AEs) by runaway electrons (REs) in post-disruption tokamak plasmas. Applying the updated code to RE beams in both DIII-D and ITER, a zoo of AE modes triggered by trapped REs due to precessional drift-kinetic resonances is computed while scanning the RE energy. At fixed RE energy, multiple unstable roots are also excited. These AE modes possess radially different eigenmode structures, ranging from global modes to core-localized ones. The computed mode frequency is in the Alfvén frequency range, increasing with the assumed RE energy in a staircase fashion and quantitatively matching the experimental measurement (in DIII-D). At the (more relevant) high-frequency range (above 1 MHz), the modeled eigenmodes are identified as compressional AEs (CAEs) in DIII-D and a mixture of CAE and shear Alfvén waves in ITER.

Alfvén eigenmodes↗

Rotational alignments in {sup 235}Np and the possible role of j{sub 15/2} neutrons

The role j{sub 15/2} neutron orbitals play in the transuranic region of actinides has been studied by exploring {gamma}-ray transitions between yrast states in {sup 235}Np, populated utilizing the nucleon-transfer reaction {sup 237}Np({sup 116}Sn,{sup 118}Sn). Two rotational sequences, presumably the two signatures of the ground-state band, have been delineated to high spin for the first time, with the {alpha}=+1/2 and {alpha}=-1/2 signature partners reaching 49/2{sup +}(Planck constant/2{pi}) (tentatively 53/2{sup +}(Planck constant/2{pi})) and 47/2{sup +}(Planck constant/2{pi}) (tentatively 51/2{sup +}(Planck constant/2{pi})), respectively. Definite isotopic assignments for these in-band transitions were established through {gamma}-ray cross correlations between {sup 235}Np and {sup 118}Sn and events where at least three {gamma} rays corresponding to neptunium-like particles were detected. These transitions reveal clear upbends in the aligned angular momentum and kinematic moment of inertia plots; such a phenomenon could indicate a strong interaction between an aligned nuj{sub 15/2} configuration crossing the ground-state band in {sup 235}Np, which is based on a pii{sub 13/2} orbital. However, the lack of any signature splitting over the observed frequency range of the {sup 235}Np rotational sequences cannot remove the possibility of a pih{sub 9/2} assignment for the observed band. The role of the nuj{sub 15/2} and pii{sub 13/2} alignment mechanisms in the deformed U-Pu region is discussed in light of the current spectroscopic data and in the context of the cranked-shell model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗