Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency stabilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Dimensional stability of fused silica, Invar, and several ultralow thermal expansion materials

A method is developed for testing the long-term dimensional stability of an iodine-stabilized He-Ne laser, using a technique whereby thermal expansion coefficients are measured by forming a Fabry-Perot etalon from the sample and monitoring the optical resonant frequencies with tunable sidebands impressed on a laser beam from a frequency-stabilized He-Ne laser. A change of 1 ppm over a 3-yr period on the part of fused silica dimensions and the differential thermal expansion of Invar LR-35 and Super Invar materials are noted. The method is of interest for the metrology of extremely stable structures such as telescopes and optical resonators.

Berthold, J. W., III↗

Stabilized fiber-optic frequency distribution system

A technique for stabilizing reference frequencies transmitted over fiber-optic cable in a frequency distribution system is discussed. The distribution system utilizes fiber-optic cable as the transmission medium to distribute precise reference signals from a frequency standard to remote users. The stability goal of the distribution system is to transmit a 100-MHz signal over a 22-km fiber-optic cable and maintain a stability of 1 part in 10(17) for 1000-second averaging times. Active stabilization of the link is required to reduce phase variations produced by environmental effects, and is achieved by transmitting the reference signal from the frequency standard to the remote unit and then reflecting back to the reference unit over the same optical fiber. By comparing the phase of the transmitted and reflected signals at the reference unit, phase variations of the remote signal can be measured. An error voltage derived from the phase difference between the two signals is used to add correction phase.

Primas, L. E.↗

Analysis of hydrogen maser frequency drift due to possible drifts in load VSWR and phase angle of reflection coefficient

Theoretical equations are derived for calculating the effects of local VSWR and reflection coefficient phase angle drifts on hydrogen maser frequency stability. Sample calculations made for a typical JPL maser show that under special load conditions, a VSWR drift of 0.000075/h or phase angle drive of 0.01 deg/h can produce a frequency drift of (10 to the -14th power f sub 0) Hz/h where f sub 0 is the maser frequency of approximately 1.42 x 10 to the 9th power Hz.

Beatty, R. W.↗

Spectrophone stabilization and offset tuning of a carbon dioxide waveguide laser

A sensitive spectrophone containing CO2 gas is incorporated into a feedback loop to stabilize the frequency of a CO2 waveguide laser. First or second harmonic detection combined with a zero offset feature and the relatively high operating pressure of the laser allows continuous tuning of the stabilized frequency over a 400 MHz range. Frequency stability of better than + or - 1 MHz is achieved.

Kavaya, M. J.↗

Radio science ground data system for the Voyager-Neptune encounter, part 1

The Voyager radio science experiments at Neptune required the creation of a ground data system array that includes a Deep Space Network complex, the Parkes Radio Observatory, and the Usuda deep space tracking station. The performance requirements were based on experience with the previous Voyager encounters, as well as the scientific goals at Neptune. The requirements were stricter than those of the Uranus encounter because of the need to avoid the phase-stability problems experienced during that encounter and because the spacecraft flyby was faster and closer to the planet than previous encounters. The primary requirement on the instrument was to recover the phase and amplitude of the S- and X-band (2.3 and 8.4 GHz) signals under the dynamic conditions encountered during the occultations. The primary receiver type for the measurements was open loop with high phase-noise and frequency stability performance. The receiver filter bandwidth was predetermined based on the spacecraft's trajectory and frequency uncertainties.

Kursinski, E. R.↗

Two-Beam multiplexed laser-induced fluorescence measurements of an argon arcjet plume

We describe a multiplexed, laser-induced fluorescence (LIF) technique with which radial and axial profiles of vector velocities of excited propellant species were obtained in the exhaust plume from a 300-W argon arcjet. Although the arcjet is a prototype, and although argon is not an interesting propellant from a propulsion perspective, the technique clearly demonstrates how a narrowband, frequency-stabilized ring-dye laser can be used to obtain simultaneous measurements of two velocity components in an arcjet plume and how a third signal from an optogalvanic cell can be used as a frequency reference. We also show that much information on the flow can be obtained by analyzing the Doppler widths and fluorescence intensities of the LIF data. Specifically, the data identify a boundary layer in the radial direction of the plume and a shock in the downstream region of the flow. Also, some flow anisotropy is observed, consistent with the assumption that the magnitude of the mean flow velocity fluctuates. The peak velocity on centerline remains roughly constant at 3 km/s throughout the expansion.

Ruyten, Wilhelmus M.↗

CARS measurement of velocity in a supersonic jet

It is shown that CW CARS can be used to measure velocity in supersonic flows. The accuracy with which the Doppler shift can be measured is determined through the drift in the laser frequencies. In the experiment described here, it is found that a laser drift error of 10 MHz during the recording of a spectrum would limit the velocity resolution to 34 m/s. It is noted that improved frequency stabilization of the laser sources could lead to a velocity measurement accuracy of several m/s. In the experiment, a 4-W single axial mode argon ion laser is the pump source, and the Stokes-shifted frequency is generated by a 100-mW tunable dye laser.

Gustafson, E. K.↗

Monolithic Isolated Single-Mode Ring Laser

MISER uses four-sided ring to lase nonreciprocally. Laser concept provides very-compact, efficient, and stable source of coherent radiation. Lasers of single, very-stable frequency desirable for number of purposes. Frequency stability makes possible coherent detection of laser radiation with low-bandwidth detector, useful for communications. Allows very-high-resolution spectroscopy. Any application where desired to use laser in way microwaves used traditionally enhanced if frequency very stable.

Kane, T. J.↗

Stability of a Crystal Oscillator, Type Si530, Inside and Beyond its Specified Operating Temperature Range

Data acquisition and control systems depend on timing signals for proper operation and required accuracy. These clocked signals are typically provided by some form of an oscillator set to produce a repetitive, defined signal at a given frequency. Crystal oscillators are commonly used because they are less expensive, smaller, and more reliable than other types of oscillators. Because of the inherent characteristics of the crystal, the oscillators exhibit excellent frequency stability within the specified range of operational temperature. In some cases, however, some compensation techniques are adopted to further improve the thermal stability of a crystal oscillator. Very limited data exist on the performance and reliability of commercial-off-the-shelf (COTS) crystal oscillators at temperatures beyond the manufacturer's specified operating temperature range. This information is very crucial if any of these parts were to be used in circuits designed for use in space exploration missions where extreme temperature swings and thermal cycling are encountered. This report presents the results of the work obtained on the operation of Silicon Laboratories crystal oscillator, type Si530, under specified and extreme ambient temperatures.

Patterson, Richard L.↗

Phase discriminating capacitive array sensor system

A phase discriminating capacitive sensor array system which provides multiple sensor elements which are maintained at a phase and amplitude based on a frequency reference provided by a single frequency stabilized oscillator. Sensor signals provided by the multiple sensor elements are controlled by multiple phase control units, which correspond to the multiple sensor elements, to adjust the sensor signals from the multiple sensor elements based on the frequency reference. The adjustment made to the sensor signals is indicated by output signals which indicate the proximity of the object. The output signals may also indicate the closing speed of the object based on the rate of change of the adjustment made, and the edges of the object based on a sudden decrease in the adjustment made.

Vranish, John M.↗

Impact of Jason-2/T2L2 Ultra-Stable-Oscillator Frequency Model on DORIS stations coordinates and Earth Orientation Parameters

Doppler Orbitography and Radiopositioning Integrated on Satellite (DORIS)is a tracking technique based on a one-way ground to space Doppler link.For Low Earth Orbit (LEO) satellites, DORIS shows a robust capability interms of data coverage and availability, due to a wide and well-distributedground network, where data are made available by the International DorisService (IDS). However, systematic errors remain in the DORIS data, suchas instabilities of the on-board clock due to radiation encountered in space,which limit the accurate determination of station positions.The DORIS on-board clock frequency stability is degraded by the increased radiation found in the region of the South Atlantic Anomaly (SAA)and has been shown to degrade station position estimation. This paper in-troduces a new model correction to the DORIS data for the frequency ofthe Jason-2 Ultra Stable Oscillator (USO), derived from the Time Transferby Laser Link (T2L2) experiment (Belli and Exertier, 2018). We show thata multi-satellite DORIS solution including this T2L2-corrected data appliedto the frequency modelling for The DORIS data, improves the estimationof station coordinates. We show the tie residuals with respect to collocatedGPS stations are improved by several millimeters. We also demonstratethat the 117-day (Jason-2) draconitic signal in the geophysical parametersis reduced, implying that the origin of this signal is not just solar radiationpressure mis-modeling, but also radiation-induced clock perturbations onthe Jason-2 DORIS Ultra-Stable-Oscillator (USO). Finally we demonstratethrough comparisons with the International Earth Rotations and ReferenceSystems Service (IERS) C04 series for Earth Orientation Parameters (EOP),that the estimation of EOP is improved in both a Jason-2 DORIS-only anda multi-satellite DORIS solution for EOP.

DORIS↗

A 200 MHz surface acoustic wave resonator mass microbalance

The development of a 200 MHz SAW instrument based on an SAW resonator instead of a conventional delay line is reported. The instrument is small, compact, and uses two separate 200 MHz resonataor crystals which operate in the dual difference mode. The difference frequency stability is better than 5 x 10 to the -9th (+ or - 1 Hz) which is comparable to a 10 MHz bulk crystal and at least an order of magnitude better than other commercially available SAW delay lines that operate at comparable frequencies. The mass sensitivity is about 9 x 10 to the 10th Hz sq cm/g. Response to temperature change is found to be about 20 Hz/C from -30 C to 30 C. Response to pressure is found to be linear from 760 to 415 Torr at 3 Hz/Torr. Detection limits for HCl vapors were determined to be in the low ppb range using an SAW resonator coated with triethanolamine.

Bowers, W. D.↗

Effects of structural coupling on mistuned cascade flutter and response

The effects of structural coupling on mistuned cascade flutter and response are analytically investigated using an extended typical section model. This model includes both structural and aerodynamic coupling between the blades. The model assumes that the structurally coupled system natural modes were determined and are represented in the form of N bending and N torsional uncoupled modes for each blade, where N is the number of blades and, hence, is only valid for blade dominated motion. The aerodynamic loads are calculated by using two dimensional unsteady cascade theories in the subsonic and supersonic flow regimes. The results show that the addition of structural coupling can affect both the aeroelastic stability and frequency. The stability is significantly affected only when the system is mistuned. The resonant frequencies can be significantly changed by structural coupling in both tuned and mistuned systems, however, the peak response is significantly affected only in the latter.

Kielb, R. E.↗

Effects of structural coupling on mistuned cascade flutter and response

The effects of structural coupling on mistuned cascade flutter and response are analytically investigated using an extended typical section model. This model includes both structural and aerodynamic coupling between the blades. The model assumes that the structurally coupled system natural modes were determined and are represented in the form of N bending and N torsional uncoupled modes for each blade, where N is the number of blades and, hence, is only valid for blade dominated motion. The aerodynamic loads are calculated by using two dimensional unsteady cascade theories in the subsonic and supersonic flow regimes. The results show that the addition of structural coupling can affect both the aeroelastic stability and frequency. The stability is significantly affected only when the system is mistuned. The resonant frequencies can be significantly changed by structural coupling in both tuned and mistuned systems, however, the peak response is significantly affected only in the latter. Previously announced in STAR as N83-15672

Kielb, R. E.↗

An electronically tuned, stable 8415 MHz dielectric resonator FET oscillator for space applications

A voltage-controlled 8415-MHz FET oscillator stabilized by a dielectric resonator is described. The oscillator provides over 3.2-MHz linear electronic tuning range with a flat power output equal to +1.8 dBm (27 C, nominal), a single-sideband noise-to-carrier ratio of -68 dBc/Hz at 1 kHz off carrier, and a frequency-temperature coefficient of 0.54 parts per million/C over a -24 C to 75 C range. The oscillator withstood 150 Krads (Si) of gamma radiation with no significant performance degradation. The overall performance of the FET oscillator is far superior in many ways to that of an equivalent bipolar oscillator for space applications. For space applications, the FET dielectric resonator oscillator (DRO) is preferred over bipolar DRO because of its lower DC power consumption, better thermal frequency stability, linear electronic tunability, and higher RF output power capability.

Mysoor, Narayan R.↗

White-Light Whispering-Gallery-Mode Optical Resonators

Whispering-gallery-mode (WGM) optical resonators can be designed to exhibit continuous spectra over wide wavelength bands (in effect, white-light spectra), with ultrahigh values of the resonance quality factor (Q) that are nearly independent of frequency. White-light WGM resonators have potential as superior alternatives to (1) larger, conventional optical resonators in ring-down spectroscopy, and (2) optical-resonator/electro-optical-modulator structures used in coupling of microwave and optical signals in atomic clocks. In these and other potential applications, the use of white-light WGM resonators makes it possible to relax the requirement of high-frequency stability of lasers, thereby enabling the use of cheaper lasers. In designing a white-light WGM resonator, one exploits the fact that the density of the mode spectrum increases predictably with the thickness of the resonator disk. By making the resonator disk sufficiently thick, one can make the frequency differences between adjacent modes significantly less than the spectral width of a single mode, so that the spectral peaks of adjacent modes overlap, making the resonator spectrum essentially continuous. Moreover, inasmuch as the Q values of the various modes are determined primarily by surface Rayleigh scattering that does not depend on mode numbers, all the modes have nearly equal Q. By use of a proper coupling technique, one can ensure excitation of a majority of the modes. For an experimental demonstration of a white-light WGM resonator, a resonator disk 0.5-mm thick and 5 mm in diameter was made from CaF2. The shape of the resonator and the fiberoptic coupling arrangement were as shown in Figure 1. The resonator was excited with laser light having a wavelength of 1,320 nm and a spectral width of 4 kHz. The coupling efficiency exceeded 80 percent at any frequency to which the laser could be set in its tuning range, which was >100-GHz wide. The resonator response was characterized by means of ring-down tests in which the excitation was interrupted by a shutter having a rise and a fall time of 5 ns. The ring-down time of photodiodes and associated circuitry used to measure the interrupted excitation and the resonator output was <1 ns. Figure 2 shows the shapes of representative input and output light pulses. The average ring-down time was found to be 120 ns, corresponding to Q=2x10(exp 8). The variations of Q with the laser carrier frequency were found to be <5 percent. Hence, the resonator was shown to have the desired white light properties.

Matsko, Andrey↗