Search NASA⌕ Search

SEARCH · Search NASA

Results for “gamma spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Methylammonium Lead Tribromide Single Crystal Detectors towards Robust Gamma-Ray Photon Sensing

In recent years, hybrid perovskite single crystalline solid-state detectors have shown promise in γ-ray spectroscopy. Here, the γ-ray photon induced electrical pulses are investigated, which are produced by perovskite solid-state detectors made with the commonly used methylammonium lead tribromide crystals with chlorine incorporation. Under low electric field detector operation, slow pulses generated by γ-rays with average rise times of 65 µs are observed, which decreases to 20 µs when a higher electrical field of 500 V cm -1 is applied. However, the baseline becomes noisy quickly, which prevents collection of clean pulses for spectra construction. Further, by systematically measuring the temperature dependence and current–voltage characteristics, such instability is attributed to the local ion migration under electrical field creating a fluctuating dark noise, which presents a major challenge in perovskite γ-ray detector technologies. It is demonstrated that cycling the bias between positive and negative polarity can stabilize the detector, allowing for longer periods of pulse accumulation for generating energy resolved spectra with resolutions of ≈35% at 59.6 keV and ≈25% at 662 keV at room temperature. The study indicates that the main limiting factors of perovskite-based γ-ray detectors are slow rise times and bias instability. Finally, these challenges must be properly addressed to achieve reproducible, high-resolution γ-ray detection.

47 OTHER INSTRUMENTATION↗

Digital pulse analysis for fast neutron recoil spectroscopy with a 4 He scintillation detector

Helium-4-based fast neutron scintillation detectors are an attractive alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, as the response of the detectors to gamma rays is intrinsically limited to low energy deposition. Consequently, the neutron recoil distribution can be measured with these detectors without the need for pulse shape analysis. In this work, the response of an Arktis S670 4 He scintillation detector to D-D, D-T, and 252 Cf neutrons was measured. The detector has a unique construction and readout mechanism, with multiple output channels observing the same scintillation event, and an analysis method was developed to aggregate the outputs from all channels into a single list. The D-D and D-T neutron responses were used to perform a two-point energy calibration, which yielded a near-zero intercept, suggesting that the 4 He scintillation medium behaves linearly to a higher energy than previously reported, and that a two-point calibration is sufficient for nuclear recoil energies below 9 MeV. As a result, the detector was measured to have 16.7-ns FWHM time resolution when using the developed custom analysis, a reduction of 4.9 ns when compared to the conventional pulse analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopic features of dissolved iodine in pristine and gamma-irradiated nitric acid solutions

While iodine speciation is important for a wide range of nuclear activities, understanding the mechanisms of the transformations of iodine between chemical forms and the sensitivity of these transitions to solution conditions and exposure to radiation remains an active area of research. This work curates spectroscopic data from several experimental techniques and establishes their sensitivity and limitations in detecting changes in iodine speciation in both neutral and acidic regimes. The techniques include Raman spectroscopy, Fourier Transform Infrared (FTIR) spectroscopy, 127 I NMR spectroscopy, and ultraviolet-visible (UV-Vis) spectroscopy. Analysis of these data indicates that these commonly accessible spectroscopies often have dynamic ranges of measurable concentrations that do not always overlap between all techniques. The experimental techniques are disparately sensitive to iodide (I - ), molecular iodine (I 2 ), iodate (IO 3 - ), and periodate (IO 4 - ) species. Raman, FTIR, and NMR spectra were subsequentially analyzed using two-dimensional correlation analyses to generate high-resolution autocorrelation spectra. Here, the use of these spectroscopies is then extended to tracking acidification-induced and gamma irradiation-induced transformations of dissolved sodium iodate in deionized water and concentrated nitric acid. Both dissolution into nitric acid and irradiation with a gamma source are demonstrated to perturb the iodine speciation promoting their assembly into molecular iodine (I 2 ) and/or triiodide (I 3 - ). While I 2 and I 3 - species are undetectable with FTIR spectroscopy and 127 I NMR spectroscopy, the species can be detected with UV-Vis spectroscopy, and in some instances, I 3 - can be detected with Raman spectroscopy in the low wavenumber region. Ultimately, the results of this work provide a path to designing optimal combinations of techniques to detect forms of iodine across a wide range of concentrations and conditions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Gamma-ray spectrum variations for surface measurements of uranium hexafluoride cylinders

Here, this work aims to characterize features that contribute to the spectral variations that appear in gamma-23 ray spectra of filled uranium hexafluoride (UF 6 ) cylinders. While the enrichment of the UF 6 in a 24 cylinder can greatly affect gamma-ray spectra at peaks such as the 185.7 keV peak and be used to 25 verify enrichment, many other characteristics of a filled UF 6 cylinder can affect the spectra. These 26 characteristics vary on a per-cylinder basis and can include: the time between when a cylinder was 27 filled and when it was measured; the previous fill history of a cylinder; how the cylinder was most 28 recently filled; the UF 6 geometric distribution within the cylinder; and the measurement location 29 along the cylinder. This work explores spectral variations seen in measurement data and uses 30 validated simulation models to find trends in these uncertainties. These trends are analyzed to observe 31 how each parameter can contribute to the overall uncertainty of UF 6 spectral measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact light shield for the Psyche gamma-ray spectrometer

A compact, low-mass light shield has been designed for the Psyche space mission high-purity germanium gamma-ray spectrometer. The spectrometer will be vented to space, which can allow solar photons to enter the cryostat and cause charge-induced noise. The light shield was designed to block more than 99.9% of solar photons while maintaining high molecular conductance to space vacuum. COMSOL simulations and experiments were performed to characterize light shield photon attenuation and molecular conductance. Finally, the light shield was integrated onto the gamma-ray spectrometer and photon suppression and vacuum performance were demonstrated.

(16) Psyche↗

Development of a compact fast-neutron spectrometer for nuclear emergency response applications

We have developed a Compact Fast Neutron Spectrometer (CFNS) for passive assay of special nuclear material (SNM) through the observation of fast neutrons. The CFNS consists of eight organic glass scintillators (OGS) coupled to silicon photomultipliers and a waveform digitizer, which are integrated within a human-portable box. The CFNS determines the neutron energy profile by spectrum unfolding using the Maximum-Likelihood Expectation Maximization method. The detector acquisition system was optimized to have a dynamic range of up to 10 MeV neutron energy. Bulk special nuclear material (SNM) measurements from the National Criticality Experiments Research Center were analyzed for SNM validation/examination. Additionally, the results show that the CFNS can be used to distinguish between fission and (α, n) neutron emitters, regardless of intervening material type (Cu and polyethylene) and thickness, by taking the ratio of neutron counts at different regions in the unfolded energy spectrum. Additionally, by fitting an exponential curve to the unfolded energy spectrum of PuO 2 and Pu neutron emitters, the CFNS showed the ability of distinguishing between pure Pu oxide, pure Pu metal and mixed oxide-metal configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Pinhole Collimators for High-Resolution Gamma Imaging of Irradiated Fuel

Post-irradiation examination (PIE) of nuclear fuels requires imaging tools capable of resolving isotopic and spatial features with high throughput. This project contributes to a proof-of-concept effort aimed at advancing gamma emission tomography (GET) by evaluating novel fine-aperture pinhole collimators. Two Rose’s metal collimators, 100 µm (20° acceptance angle) and 350 µm (30° acceptance angle), were prototyped and characterized for their effectiveness in transporting gamma rays through the pinhole aperture. To support data collection, a Python-based data acquisition system was developed to coordinate a rotation stage, linear stage, and CZT detector, reducing latency in high-rate gamma event logging to one second per acquisition. Queue-based file writing enabled seamless real-time data capture for count rates up to 35,000 counts per second (cps). List-mode parsing algorithms were implemented to differentiate single and simultaneous gamma interactions for future tomographic reconstruction. Detector response was evaluated in both spectroscopy and list mode acquisition methods across varying source distances to confirm absolute and collimator efficiencies. Preliminary efficiency figures suggest effective collimation of gamma-rays with energies below 700 keV, with ~4% residual intensity through the aperture for Cs-137. The impact of collimator geometry on image quality is currently being evaluated. This groundwork supports the ongoing development of a sub mm resolution cone-beam CT system for imaging fuel phantoms, an essential step toward improving GET efficiency and accelerating nuclear fuel qualification efforts.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Impact of Glass Irradiation on Laser-induced Breakdown Spectroscopy Diagnostics in the Visible and NIR Range

Increased absorption of optical materials arising from the exposure to ionizing radiation must be accounted for to accurately analyze the laser-induced breakdown spectroscopy (LIBS) data retrieved from high-radiation environments. We evaluate this effect on a specifc example that mimics the diagnostics placed within a gas-cooled fast reactor coolant stream. Analysis is performed on the LIBS data measured with 1% Xe gas in an ambient He environment and the measured optical absorption from the gamma- and neutron-irradiated low-OH fused silica and sapphire glasses. No significant change in the number of shots required to reach a 3σ detection level was observed up to 10 Mrad gamma dose and exposure to a 1.7×10 17 n/cm 2 neutron fluence. In contrast, the spectral dependence of absorption results in either a systematic overestimation or underestimation of line intensity ratios, depending on the line of interest selected for analysis. Moreover, if lines from different spectral regions are used to create Boltzmann plots, this attenuation also leads to statistically significant changes in the calculated temperatures for calculations using Xe II lines only, lowering them from 8000±610 K to 6800±810 K for the case of exposure to the 1.7×10 17 n/cm 2 flux, and broadening the temperature range required for a 95% confidence interval. In the case of measuring the Xe spectrum, these effects may be mitigated using only the longer-wavelength spectral region, where radiation-attenuation is relatively small, or through analysis using the iterative Saha-Boltzmann method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gamma radiation-induced defects in KCl, MgCl 2 , and ZnCl 2 salts at room temperature

Room temperature post-irradiation measurements of diffuse reflectance and electron paramagnetic resonance spectroscopies were made to characterize the long-lived radiation-induced species formed from the gamma irradiation of solid KCl, MgCl 2 , and ZnCl 2 salts up to 100 kGy. The method used showed results consistent with those reported for electron and gamma irradiation of KCl in single crystals. Thermal bleaching of irradiated KCl demonstrated accelerated disaggregation of defect clusters above 400 K, due to decomposition of Cl 3 - . The defects formed in irradiated MgCl 2 comprised a mixture of Cl 3 - , F-centers, and Mg + associated as M-centers. Further, Mg metal cluster formation was also observed at 100 kGy, in addition to accelerated destruction of F-centers above 20 kGy. Irradiated ZnCl 2 afforded the formation of Cl 2 - due to its high ionization potential and crystalline structure, which decreases recombination. The presence of aggregates in all cases indicates the high diffusion of radicals and the predominance of secondary processes at 295 K. Additionally, thermal bleaching studies showed that chloride aggregates’ stability increases with the ionization potential of the cation present. The characterization of long-lived radiolytic transients of pure salts provides important information for the understanding of complex salt mixtures under the action of gamma radiation.

36 MATERIALS SCIENCE↗

Complete set of bound negative-parity states in the neutron-rich nucleus 18 N

High-resolution γ -ray spectroscopy of N 18 is performed with the Advanced GAmma Tracking Array, following deep-inelastic processes induced by an O 18 beam on a Ta 181 target. Six states are newly identified, which together with the three known excitations exhaust all negative-parity excited states expected in N 18 below the neutron threshold. Spin and parities are proposed for all located states on the basis of decay branchings and comparison with large-scale shell-model calculations performed in the p-sd space, with the YSOX interaction. Of particular interest is the location of the 0 1 - and 1 2 - excitations, which provide strong constrains for cross-shell p-sd matrix elements based on realistic interactions and help to simultaneously reproduce the ground and first-excited states in N 16 and N 18 , for the first time. Overall, understanding the N 18 structure may also have significant impact on neutron-capture cross-section calculations in r-process modeling including light neutron-rich nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Indium Tin-Doped Oxide Interactions with Solvent Radiolysis Products

Transparent conductive oxides (TCOs), such as indium tin-doped oxide (ITO), are ubiquitous as components of electronics and are ideal electrode substrates for catalysis, energy transformation reactions, and energy storage applications. Recently, researchers have recognized their effectiveness as electrode materials for manipulating actinide oxidation states in solution. Despite their popularity as electrode materials, prior studies focused extensively on the direct radiolysis of TCO materials in air and rarely examined these effects within a solution, limiting our fundamental understanding of the interactions between solvent radiolysis products and these substrates in high radiation environments. Here, in this study, we characterize the effects of solvent radiolysis products—arising from the gamma irradiation of water, aqueous nitric acid solutions, and n-dodecane—on the composition, surface speciation, and band structure of ITO thin films on a glass substrate as a function of absorbed dose using UV-visible spectroscopy, scanning electron microscopy, photoelectrochemistry, and X-ray photoelectron spectroscopy. Our work demonstrates that mesoporous thin film electrodes of ITO exposed to gamma radiation in each solvent accumulate defects and exhibit solvent and dose dependent changes to their surface and interfacial properties. These electrodes maintain their electrochemical function and improve their photoelectrochemical performance up to at least 100 kGy of accumulated gamma dose, confirming their utility in solvents exposed to ionizing radiation fields.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact of Glass Irradiation on Laser-Induced Breakdown Spectroscopy Data Analysis

Increased absorption of optical materials arising from exposure to ionizing radiation must be accounted for to accurately analyze laser-induced breakdown spectroscopy (LIBS) data retrieved from high-radiation environments. We evaluate this effect on two examples that mimic the diagnostics placed within novel nuclear reactor designs. The analysis is performed on LIBS data measured with 1% Xe gas in an ambient He environment and 1% Eu in a molten LiCl-KCl matrix, along with the measured optical absorption from the gamma- and neutron-irradiated low-OH fused silica and sapphire glasses. Significant changes in the number of laser shots required to reach a 3σ detection level are observed for the Eu data, increasing by two orders of magnitude after exposure to a 1.7 × 1017 n/cm2 neutron fluence. For all cases examined, the spectral dependence of absorption results in the introduction of systematic errors. Moreover, if lines from different spectral regions are used to create Boltzmann plots, this attenuation leads to statistically significant changes in the temperatures calculated from the Xe II lines and Eu II lines, lowering them from 8000 ± 610 K to 6900 ± 810 K and from 15,800 ± 400 K to 7200 ± 800 K, respectively, for exposure to the 1.7 × 1017 n/cm2 fluence. The temperature range required for a 95% confidence interval for the calculated temperature is also broadened. In the case of measuring the Xe spectrum, these effects may be mitigated using only the longer-wavelength spectral region, where radiation attenuation is relatively small, or through analysis using the iterative Saha–Boltzmann method.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Post irradiation examination of a uranium-zirconium hydride TRIGA fuel element

Low-enriched (LEU) U-ZrH fuel, with a 235 U content less than 20% of the total uranium, is being evaluated for possible use in different types of reactors, including space nuclear systems, light water reactors (LWRs) and micro-reactors. As a result, it is beneficial to better understand the macrostructural and microstructural changes that occur in this fuel during irradiation. This paper reports the results of the post irradiation examination of an LEU U-ZrH fuel element (30 wt.% U, <20% 235 U) using neutron radiography, precision gamma scanning, chemical analysis, optical metallography and scanning electron microscopy combined with energy dispersive spectroscopy and wavelength dispersive spectroscopy, where the fuel element was irradiated in a Training, Research, Isotope, General Atomics (TRIGA) reactor. Results of microstructural characterization indicated some dehydriding and cracking of the U-ZrH fuel occurred during irradiation; an axial and radial burnup gradient existed in the fuel during irradiation, as measured by gamma scanning and chemical analysis; negligible microstructural changes transpired during irradiation, based on comparison of irradiated and as-fabricated U-ZrH fuel microstructures; and, negligible, fission product-rich, phases could be resolved in a U-ZrH fuel that was irradiated to a calculated 20% depletion of 235 U.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

GeMini: A High-Resolution, Low-Resource, Gamma-Ray Spectrometer for Planetary Science Applications

GeMini is a high-resolution gamma-ray spectrometer designed for planetary-science exploration. GeMini serves as the basis for instruments being flown on three upcoming deep-space missions: NASA’s mission to the M-class asteroid (16) Psyche, the Japan Aerospace Exploration Agency sample-return mission to the moons of Mars, and NASA’s Dragonfly mission that will land on Saturn’s largest moon, Titan. These science missions require high-resolution spectroscopy in a low-power, low-mass, rugged design that can survive in a variety of environments. GeMini addresses these needs by providing a cryogenically cooled crystal of high-purity germanium that can operate with as little as 10 to 20 watts, depending on the implementation and mission, and has a mass of less than 2 kg. GeMini helps determine the elemental composition of planetary bodies by measuring gamma rays emitted from the surface. This paper describes the mechanical, thermal, and electrical design of GeMini as well as its performance. Further, it describes testing that was performed to validate the design with respect to launch loads and radiation damage. Although the basic design of GeMini is common to all three missions, each planetary body has unique environmental conditions and mission specifications. This paper concludes by describing these upcoming missions and how GeMini is customized for each.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiolytic evaluation of select sulfur chlorides (S 2 Cl 2 and SOCl 2 ) for advanced low temperature chlorination of zirconium-based used nuclear fuel cladding

New sulfur chloride compounds—sulfur monochloride (S 2 Cl 2 ) and thionyl chloride (SOCl 2 )—have been proposed as alternative chlorinating agents for the chemical decladding of zirconium-based used nuclear fuel cladding materials. However, the radiation stability of these compounds has not been thoroughly evaluated, despite envisioned process conditions involving intense, multi-component radiation fields. Knowledge of the radiation chemistry of these sulfur chlorides is essential for the development and optimization of alternative chlorination technologies. To this end, we present preliminary findings on the gamma radiolysis of neat S 2 Cl 2 and SOCl 2 at ambient temperature up to ~ 34 MGy. In this study, Raman spectroscopy and density functional theory calculations were used to identify the Raman-active degradation products from S 2 Cl 2 and SOCl 2 radiolysis. Both sulfur chloride compounds exhibited significant radiation resistance, with respect to changes in the Raman signatures of the parent compounds and the ingrowth of Raman-active degradation products. For S 2 Cl 2 , molecular chlorine (Cl 2 ) was directly identified as the predominant degradation product, which was completely consumed at higher absorbed doses (> 9 MGy). Similarly, the main degradation product from SOCl 2 radiolysis was also Cl 2 , although in this system it continued to grow in with dose over the entire dose range. Further, an “S=O” containing degradation product(s) was also identified as a compliment to Cl 2 . Overall, the perceived radiation resistance of these sulfur chloride compounds makes them suitable for inclusion in a used nuclear fuel chemical decladding process, especially as radiolytically formed Cl 2 can be used to reform the parent compounds, thereby increasing the longevity of the solvents used.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Design of a high-temperature cell for cobalt-60 irradiations of aqueous solutions with in situ UV–visible spectroscopy

To understand the speciation of solutes in aqueous solutions in high temperature radiation environments, we report the design and fabrication of a custom-built, high temperature (≤300 °C) titanium irradiation cell with in situ optical spectroscopy capabilities, as afforded by coupled fiber optic cables. The wetted surfaces of the 8-inch tall cylindrical cell with 3.5 in. diameter are entirely made of titanium, sapphire, and gold, which are chemically and radiolytically inert. The initial benchmarking results are reported, including the baseline spectrum of deionized water as a function of temperature, the stability of a spectrum over 4 h at 100 °C, and an irradiated Fricke dosimetry solution under ambient irradiator temperature conditions (27.0 ± 0.5 °C). Further, the average gamma radiation dose rate in the cell in its current configuration is 26.1 ± 1.3 Gy min -1 . This cell has application in studying several processes throughout the nuclear fuel cycle, including the reactor coolant behavior.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The effect of gamma ray irradiation on few layered MoSe2: A material for nuclear and space applications

In recent years, emerging two-dimensional (2D) materials, such as molybdenum diselenide (MoSe2), have been at the center of attention for many researchers. This is due to their unique and fascinating physicochemical properties that make them attractive in space and defense applications that include shielding harsh irradiation environments. In this study, we examined the effects of gamma (γ) rays at various doses on the structural, chemical, and optical properties of MoSe2 layers. After the samples were exposed to intense gamma radiation (from a 60Co source) with various exposure times to vary the total accumulated dosage (up to 100 kGy), Raman and photoluminescence spectroscopies were used to study and probe radiation-induced changes to the samples. When compared to pristine materials, very few changes in optical properties were typically observed, indicating good robustness with little sensitivity, even at relatively high doses of gamma radiation. The imaging using scanning electron microscopy revealed a number of nano-hillocks that were connected to substrate alterations. X-ray photoelectron spectroscopies revealed that Mo’s binding energies remained the same, but Se’s binding energies blueshifted. We associated this shift with the decrease in Se vacancies that occurred after irradiation as a result of Mo atoms creating adatoms next to Se atoms. When compared to pristine materials, very few changes in optical, chemical, and structural properties were typically observed. These findings highlight the inherent resilience of MoSe2 in hostile radioactive conditions, which spurs additional research into their optical, electrical, and structural characteristics as well as exploration for potential space, energy, and defense applications.

Materials Science↗

Effects of X-Rays, Electron Beam, and Gamma Irradiation on Chemical and Physical Properties of EVA Multilayer Films

Gamma-ray irradiation, using the cobalt-60 isotope, is the most common radiation modality used for medical device and biopharmaceutical products sterilization. Although X-ray and electron-beam (e-beam) sterilization technologies are mature and have been in use for decades, impediments remain to switching to these sterilization modalities because of lack of data on the resulting radiation effects for the associated polymers, as well as a lack of education for manufacturers and regulators on the viability of these sterilization alternatives. For this study, the compatibility of ethylene vinyl acetate (EVA) multilayer films with different ionizing radiation sterilization (X-ray, e-beam, and gamma irradiation) is determined by measuring chemical and physical film properties using high performance liquid chromatography, differential scanning calorimetry, Fourier-Transform InfraRed spectroscopy (FTIR), surface energy measurement, and electron spin resonance techniques. The results indicate that the three irradiation modalities induce no differences in thermal properties in the investigated dose range. Gamma and X-Ray irradiations generate the same level of reactive species in the EVA multilayer film, whereas e-beam generates a reduced quantity of reactive species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗