Search NASA⌕ Search

SEARCH · Search NASA

Results for “gradient filter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Porotomo: InSAR Data from San Emidio Geothermal Field, Nevada, 1992-2010

This submission contains tarred pair directories for interferometric synthetic aperture radar (InSAR) data covering San Emidio Geothermal Field in Nevada, USA as part of the porotomo project. Data included within this submission are the following: > ENVI_T120_GDR.tgz: Tarred directory containing 39 Envisat track 120 tarred, pair subdirectories spanning from 2003-Oct-29 to 2010-Jun-09. > ENVI_T27_GDR.tgz: Tarred directory containing 32 Envisat track 27 tarred, pair subdirectories spanning from 2004-Jun-23 to 2010-Apr-28. > ERS_T27_GDR.tgz: Tarred directory containing 35 ERS track 27 tarred, pair subdirectories spanning from 1992-Jun-07 to 2000-Sep-27. > ENVI_T27_SQR_drange_utm_cut.grd: SqueeSAR-derived data product for Enivsat track 27 from Eneva, et al. (2011) (provided by TRE Altamira) in terms of unwrapped range change rate. > MSTvsSQR_GDR.tgz: Tarred directory containing Easting gradient files for each satellite and track corresponding to the MST data products and the SqueeSAR data products. > sanem_dem_utm.grd: Digital elevation model (DEM) used in the creation of the interferograms. Explanation of pair subdirectories (contained within ENVI_T120_GDR, ENVI_T27_GDR, ERS_T27_GDR): Pairs are chosen based on a minimum spanning tree (MST) algorithm with image quality (as measured by the amount of phase noise within an interferometric pair) as the weighting criterion. Pairs are formed using the InSAR processing software GMT5SAR (Sandwell et al., 2011). Pair subdirectories are named by starting and ending epochs in YYYYMMDD_YYYYMMDD format. Each tarred pair directory contains GRD files for wrapped phase data (radians) and wrapped phase data after application of a modified Goldstein filter that depends on coherence (Goldstein & Werner, 1997; Baran et al., 2003; Sandwell et al., 2011). The data are given in both latitude/longitude and Universal Transverse Mercator (Zone 11N). Raw Synthetic Aperture Radar (SAR) data from the Envisat and ERS satellite missions operated by the European Space Agency (ESA) are copyrighted by ESA and were provided through the WInSAR consortium at the UNAVCO facility.

15 GEOTHERMAL ENERGY↗

Domain wall diode based on functionally graded Dzyaloshinskii–Moriya interaction

In this work, we present a general approach for studying the dynamics of domain walls in biaxial ferromagnetic stripes with functionally graded Dzyaloshinskii–Moriya interaction (DMI). By engineering the spatial profile of the DMI parameter we propose the concept of a diode, which implements filtering of domain walls of certain topological charge and helicity. We base our study on phenomenological Landau–Lifshitz–Gilbert equations with additional Zhang–Li spin-transfer terms using a collective variable approach. In the effective equations of motion the gradients of DMI play the role of a driving force which competes with current driving. All analytical predictions are confirmed by numerical simulations.

36 MATERIALS SCIENCE↗

Preliminary study of the application of the Timation 3 satellite to earth physics

The Timation 3 is a timing and navigation satellite originally planned for launch in December 1972 into a circular orbit at 98 deg inclination 14,000 km altitude with gravity gradient stabilization. An error analysis indicates a satellite position uncertainty of about one meter, 80 percent of which is attributable to the assumed gravity model errors. The remaining uncertainties have a period equal to that of the satellites and can be filtered out yielding an effective uncertainty of about 10 cm in the study of phenomena having different periodicities. The accomplishment of these results depends on a careful consideration of solar radiation pressure taking account of the spacecraft reflecting properties and variations in the presentation area. Consideration is also given to the displacement of the laser reflectors from the center of mass of the spacecraft and to the dynamic coupling of any libration in attitude with the orbital motion. The results indicate that a good set of well distribution laser observations of Timation 3 could yield determinations of polar motion, sea floor spreading, solid earth tides, and earth rotation at the 10 cm level.

Carpenter, L.↗

Vascular pressures and passage of gas emboli through the pulmonary circulation

Doppler technique was used to measure the pulmonary vascular pressure gradients in dogs that received venous air emboli (VAE) at the rate of 0.35 ml/kg per min, at which the spillover of bubbles into the systemic arteries occur. It was found that, in 60 percent of dogs, venous bubbles spilled over into the arterial circulation at the pulmonary vascular pressure gradient of about 34.7 mm Hg. When the pulmonary vascular pressure gradient was raised to about 52 mm Hg, the spillover of venous bubbles occurred 100 percent of time. It is concluded that venous bubbles can cross the lungs of anesthetized dogs when the driving pressures are sufficient to overcome the normal filtering function.

Butler, B. D.↗

Dosimetric Impact of Intrafraction Motion During RapidArc Stereotactic Vertebral Radiation Therapy Using Flattened and Flattening Filter-Free Beams

Purpose: To study the dosimetric impact of relatively short-duration intrafraction shifts during a single fraction of RapidArc delivery for vertebral stereotactic body radiation therapy (SBRT) using flattened (FF) and flattening filter-free (FFF) beams. Methods and Materials: The RapidArc plans, each with 2 to 3 arcs, were generated for 9 patients using 6-MV FF and 10-MV FFF beams with maximum dose rates of 1000 and 2400 MU/min, respectively. A total of 1272 plans were created to estimate the dosimetric consequences in target and spinal cord volumes caused by intrafraction shifts during one of the arcs. Shifts of 1, 2, and 3 mm for periods of 5, 10, and 30 seconds, and 5 mm for 5 and 10 seconds, were modelled during a part of the arc associated with high doses and steep dose gradients. Results: For FFF plans, shifts of 2 mm over 10 seconds and 30 seconds could increase spinal cord D{sub max} by up to 6.5% and 13%, respectively. Dosimetric deviations in FFF plans were approximately 2-fold greater than in FF plans. Reduction in target coverage was <1% for 83% and 96% of the FFF and FF plans, respectively. Conclusion: Even short-duration intrafraction shifts can cause significant dosimetric deviations during vertebral SBRT delivery, especially when using very high dose rate FFF beams and when the shift occurs in that part of the arc delivering high doses and steep gradients. The impact is greatest on the spinal cord and its planning-at-risk volume. Accurate and stable patient positioning is therefore required for vertebral SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

IMAGING THE ELUSIVE H-POOR GAS IN THE HIGH adf PLANETARY NEBULA NGC 6778

We present the first direct image of the high-metallicity gas component in a planetary nebula (NGC 6778), taken with the OSIRIS Blue Tunable Filter centered on the O ii λ 4649+50 Å optical recombination lines (ORLs) at the 10.4 m Gran Telescopio Canarias. We show that the emission of these faint O ii ORLs is concentrated in the central parts of the planetary nebula and is not spatially coincident either with emission coming from the bright [O iii] λ 5007 Å collisionally excited line (CEL) or the bright H α recombination line. From monochromatic emission line maps taken with VIMOS at the 8.2 m Very Large Telescope, we find that the spatial distribution of the emission from the auroral [O iii] λ 4363 line resembles that of the O ii ORLs but differs from nebular [O iii] λ 5007 CEL distribution, implying a temperature gradient inside the planetary nebula. The centrally peaked distribution of the O ii emission and the differences with the [O iii] and H i emission profiles are consistent with the presence of an H-poor gas whose origin may be linked to the binarity of the central star. However, determination of the spatial distribution of the ORLs and CELs in other PNe and a comparison of their dynamics are needed to further constrain the geometry and ejection mechanism of the metal-rich (H-poor) component and hence, understand the origin of the abundance discrepancy problem in PNe.

79 ASTRONOMY AND ASTROPHYSICS↗

Orb5: A global electromagnetic gyrokinetic code using the PIC approach in toroidal geometry

This paper presents the current state of the global gyrokinetic code Orb5 as an update of the previous reference [Jolliet et al., Comp. Phys. Commun. 177 409 (2007)]. The Orb5 code solves the electromagnetic VlasovMaxwell system of equations using a PIC scheme and also includes collisions and strong flows. The code assumes multiple gyrokinetic ion species at all wavelengths for the polarization density and drift-kinetic electrons. Variants of the physical model can be selected for electrons such as assuming an adiabatic response or a “hybrid” model in which passing electrons are assumed adiabatic and trapped electrons are drift-kinetic. A Fourier filter as well as various control variates and noise reduction techniques enable simulations with good signal-to-noise ratios at a limited numerical cost. They are completed with different momentum and zonal flow-conserving heat sources allowing for temperature-gradient and flux-driven simulations. The code, which runs on both CPUs and GPUs, is well benchmarked against other similar codes and analytical predictions, and shows good scalability up to thousands of nodes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Topology optimization of finite strain viscoplastic systems under transient loads [Dynamic topology optimization based on finite strain visco-plasticity]

In this paper, a transient finite strain viscoplastic model is implemented in a gradient-based topology optimization framework to design impact mitigating structures. The model's kinematics relies on the multiplicative split of the deformation gradient, and the constitutive response is based on isotropic hardening viscoplasticity. To solve the mechanical balance laws, the implicit Newmark-beta method is used together with a total Lagrangian finite element formulation. The optimization problem is regularized using a partial differential equation filter and solved using the method of moving asymptotes. Sensitivities required to solve the optimization problem are derived using the adjoint method. To demonstrate the capability of the algorithm, several protective systems are designed, in which the absorbed viscoplastic energy is maximized. Finally, the numerical examples demonstrate that transient finite strain viscoplastic effects can successfully be combined with topology optimization.

42 ENGINEERING↗

DPM: A deep learning PDE augmentation method with application to large-eddy simulation

A framework is introduced that leverages known physics to reduce overfitting in machine learning for scientific applications. The partial differential equation (PDE) that expresses the physics is augmented with a neural network that uses available data to learn a description of the corresponding unknown or unrepresented physics. Training within this combined system corrects for missing, unknown, or erroneously represented physics, including discretization errors associated with the PDE's numerical solution. For optimization of the network within the PDE, an adjoint PDE is solved to provide high-dimensional gradients, and a stochastic adjoint method (SAM) further accelerates training. Additionally, the approach is demonstrated for large-eddy simulation (LES) of turbulence. High-fidelity direct numerical simulations (DNS) of decaying isotropic turbulence provide the training data used to learn sub-filter-scale closures for the filtered Navier–Stokes equations. Out-of-sample comparisons show that the deep learning PDE method outperforms widely-used models, even for filter sizes so large that they become qualitatively incorrect. It also significantly outperforms the same neural network when a priori trained based on simple data mismatch, not accounting for the full PDE. Measures of discretization errors, which are well-known to be consequential in LES, point to the importance of the unified training formulation's design, which without modification corrects for them. For comparable accuracy, simulation runtime is significantly reduced. A relaxation of the typical discrete enforcement of the divergence-free constraint in the solver is also successful, instead allowing the DPM to approximately enforce incompressibility physics. Since the training loss function is not restricted to correspond directly to the closure to be learned, training can incorporate diverse data, including experimental data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gain Stability of Hamamatsu R5912-MOD Photo-Multipliers at Low Temperature

The Photon Detection System is a crucial component of the ICARUS detector in the Short Baseline Neutrino (SBN) Program at Fermi National Accelerator Laboratory (FNAL). It consists of 360 Photo Multiplier Tubes (PMTs) 8” Hamamatsu R5912-MOD and, since June 2020, it has been operated at the liquid Argon cryogenic temperature. During these years, the PMTs have shown gain losses as an aging effect. Using a climatic chamber at the INFN Sezione di Catania, we confirmed a stable gain for a single PMT 8” Hamamatsu 5912-MOD when operated at room temperature, and a persistent gain loss at temperatures around -70°C, although far from the liquid Argon one. No gain recovery was obtained bringing the PMT back to room temperature. We suspect that dynode deterioration due to temperature gradient plays a significant role in this phenomenon. During our test, the PMT was illuminated by a 520 nm laser source and operated in current mode. The laser beam was split into two optical fibers, the first one transmitting light through Neutral Density filters and then diffusing it over the surface of the PMT photocathode. The other optical fiber was used for an independent reference measurement of the injected light via a bolometric photodetector. In this presentation, the main technical characteristics of the measurement system are shown together with preliminary results which need further investigation to elucidate the underlying mechanisms driving the gain loss and to propose new mitigation strategies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photometric Detection of Multiple Populations in Globular Clusters Using Integrated Light

We investigate the multiple stellar populations of the globular clusters (GCs) M3, M5, M13, and M71 using g{sup ′} and intermediate-band CN-λ3883 photometry obtained with the WIYN 0.9 m telescope on Kitt Peak. We find a strong correlation between red giant stars’ CN−g{sup ′} colors and their spectroscopic sodium abundances, thus demonstrating the efficacy of the two-filter system for stellar population studies. In all four clusters, the observed spread in red giant branch CN−g{sup ′} colors is wider than that expected from photometric uncertainty, confirming the well-known chemical inhomogeneity of these systems. M3 and M13 show clear evidence for a radial dependence in the CN-band strengths of its red giants, while the evidence for such a radial dependence of CN strengths in M5 is ambiguous. Our data suggest that the dynamically old, relatively metal-rich M71 system is well mixed, as it shows no evidence for chemical segregation. Finally, we measure the radial gradients in the integrated CN−g{sup ′} color of the clusters and find that such gradients are easily detectable in the integrated light. We suggest that photometric observations of color gradients within GCs throughout the Local Group can be used to characterize their multiple populations, and thereby constrain the formation history of GCs in different galactic environments.

79 ASTRONOMY AND ASTROPHYSICS↗

A CO 2 laser heating system for in situ high pressure-temperature experiments at HPCAT

We present a CO 2 laser heating setup for synchrotron x-ray diffraction inside a diamond anvil cell, situated at HPCAT (Sector 16, Advanced Photon Source, Argonne National Lab, Illinois, USA), which is modular and portable between the HPCAT experiment hutches. Specifically, the system allows direct laser heating of wide bandgap insulating materials to thousands of degrees at static high pressures up to the Mbar regime. Alignment of the focused CO 2 laser spot is performed using a mid-infrared microscope, which addressed past difficulties with aligning the invisible radiation. The implementation of the mid-infrared microscope alongside a mirror pinhole spatial filter system allows precise alignment of the heating laser spot and optical pyrometry measurement location to the x-ray probe. A comparatively large heating spot (~50 μ m) relative to the x-ray beam (<10 μ m) reduces the risk of temperature gradients across the probed area. Each component of the heating system and its diagnostics have been designed with portability in mind and compatibility with the various experimental hutches at the HPCAT beamlines. We present measurements on ZrO 2 at 5.5 GPa which demonstrate the improved room-temperature diffraction data quality afforded by annealing with the CO 2 laser. We also present in situ measurements at 5.5 GPa up to 2800 K in which we do not observe the postulated fluorite ZrO 2 structure, in agreement with recent findings.

47 OTHER INSTRUMENTATION↗

FTICR-MS data

Soils along a salinity gradient from a coastal forested floodplain (Beaver Creek in Western Washington) were analyzed for their organic compound signatures using Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FTICR). This contains 12T FTICR reports of water and chloroform fraction of soils, processed data using FREDA, data filtering steps in FREDA, data used to generate van Krevelen plots, and code for analyzing FTICR data and performing statistics.

54 ENVIRONMENTAL SCIENCES↗

TESTING GALAXY FORMATION MODELS WITH THE GHOSTS SURVEY: THE COLOR PROFILE OF M81's STELLAR HALO

We study the properties of the stellar populations in M81's outermost part, which hereafter we will call the stellar halo, using Hubble Space Telescope (HST) Advanced Camera for Surveys observations of 19 fields from the GHOSTS survey. The observed fields probe the stellar halo out to a projected distance of {approx}50 kpc from the galactic center. Each field was observed in both F606W and F814W filters. The 50% completeness levels of the color-magnitude diagrams (CMDs) are typically at 2 mag below the tip of the red giant branch (TRGB). Fields at distances closer than 15 kpc show evidence of disk-dominated populations whereas fields at larger distances are mostly populated by halo stars. The red giant branch (RGB) of the M81's halo CMDs is well matched with isochrones of {approx}10 Gyr and metallicities [Fe/H] {approx} - 1.2 dex, suggesting that the dominant stellar population of M81's halo has a similar age and metallicity. The halo of M81 is characterized by a color distribution of width {approx}0.4 mag and an approximately constant median value of (F606W - F814W) {approx}1 mag measured using stars within the magnitude range 23.7 {approx}< F814W {approx}< 25.5. When considering only fields located at galactocentric radius R > 15 kpc, we detect no color gradient in the stellar halo of M81. We place a limit of 0.03 {+-} 0.11 mag difference between the median color of RGB M81 halo stars at {approx}15 and at 50 kpc, corresponding to a metallicity difference of 0.08 {+-} 0.35 dex over that radial range for an assumed constant age of 10 Gyr. We compare these results with model predictions for the colors of stellar halos formed purely via accretion of satellite galaxies. When we analyze the cosmologically motivated models in the same way as the HST data, we find that they predict no color gradient for the stellar halos, in good agreement with the observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Clouds above the Martin Limb: Viking observations

Whenever Viking Orbiter images included the limb of Mars, they recorded one or more layers of clouds above the limb. The height above the limb and the brightness (reflectivity) of these clouds were determined in a selected group of these images. Normalized individual brightness profiles of three separate traverses across the limb of each image are shown. The most notable finding is that some of these clouds can be very high. Many reach heights of over 60 km, and several are over 70 km above the limb. Statistically, the reflectivity of the clouds increases with phase angle. Reflectivity and height both appear to vary with season, but the selected images spanned only one Martian year, so the role of seasons cannot be isolated. Limb clouds in red-filter images tend to be brighter than violet-filter images, but both season and phase appear to be more dominant factors. Due to the limited sample available, the possible influences of latitude and longitude are less clear. The layering of these clouds ranges from a single layer to five or more layers. Reflectivity gradients range from smooth and gentle to steep and irregular.

Martin, L. J.↗

End-compensated magnetostatic cavity for polarized {sup 3}He neutron spin filters

We have expanded upon the ''Magic Box'' concept, a coil driven magnetic parallel plate capacitor constructed out of mu-metal, by introducing compensation sections at the ends of the box that are tuned to limit end-effects similar to those of short solenoids. This ability has reduced the length of the magic box design without sacrificing any loss in field homogeneity, making the device far more applicable to the often space limited neutron beam line. The appeal of the design beyond affording longer polarized {sup 3}He lifetimes is that it provides a vertical guide field, which facilitates neutron spin transport for typical polarized beam experiments. We have constructed two end-compensated magic boxes of dimensions 28.4x40x15 cm{sup 3} (lengthxwidthxheight) with measured, normalized volume-averaged transverse field gradients ranging from 3.3x10{sup -4} to 6.3x10{sup -4} cm{sup -1} for cell sizes ranging from 8.1x6.0 to 12.0x7.9 cm{sup 2} (diameterxlength), respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An iterative stochastic ensemble method for parameter estimation of subsurface flow models

Parameter estimation for subsurface flow models is an essential step for maximizing the value of numerical simulations for future prediction and the development of effective control strategies. We propose the iterative stochastic ensemble method (ISEM) as a general method for parameter estimation based on stochastic estimation of gradients using an ensemble of directional derivatives. ISEM eliminates the need for adjoint coding and deals with the numerical simulator as a blackbox. The proposed method employs directional derivatives within a Gauss–Newton iteration. The update equation in ISEM resembles the update step in ensemble Kalman filter, however the inverse of the output covariance matrix in ISEM is regularized using standard truncated singular value decomposition or Tikhonov regularization. We also investigate the performance of a set of shrinkage based covariance estimators within ISEM. The proposed method is successfully applied on several nonlinear parameter estimation problems for subsurface flow models. The efficiency of the proposed algorithm is demonstrated by the small size of utilized ensembles and in terms of error convergence rates.

97 MATHEMATICS AND COMPUTING↗

Estimating IMU heading error from SAR images.

Angular orientation errors of the real antenna for Synthetic Aperture Radar (SAR) will manifest as undesired illumination gradients in SAR images. These gradients can be measured, and the pointing error can be calculated. This can be done for single images, but done more robustly using multi-image methods. Several methods are provided in this report. The pointing error can then be fed back to the navigation Kalman filter to correct for problematic heading (yaw) error drift. This can mitigate the need for uncomfortable and undesired IMU alignment maneuvers such as S-turns.

47 OTHER INSTRUMENTATION↗