Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid synchronization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Single Stage PLL-less Decoupled Active and Reactive Power Control for Weak Grid Interactive Inverters

This paper presents a single stage phase locked loop-less (PLL-less) active and reactive power (PQ) control for single-phase weak grid interactive inverters. The absence of the PLL requirement in the proposed PQ control enhances the stability margin comparing to conventional current control approaches in both the stationary or the synchronous reference frame. Additionally, the proposed control scheme enables direct PQ control with a single loop control structure. This paper demonstrates that the proposed PLL-less PQ control scheme is asymptotically stable if the controller gains are positive. The necessary conditions for supplying the rated active power into the weak grid are derived. The provided analysis shows that certain amount of reactive power injection is necessary to avoid point of common coupling (PCC) voltage collapse when the rated active power is injected into the weak grid. Several case studies are provided to demonstrate the performance of the proposed PLL-less PQ control scheme under weak grid condition.

Khan, Ahmad↗

Technical Bulletin 005: NTP Monitoring

The Center for Alternative Synchronization and Timing (CAST) views Precision Time Protocol (PTP) and Network Time Protocol (NTP) as critical elements of the grid, from generation to the grid edge. This tech bulletin discusses the operation of NTP. The document shows not only commercial but also open-source applications. In some cases, the commercial applications may already have existing feature sets to secure and monitor NTP streams. From a security standpoint, using subscription NTP is risky unless the open bidirectional ports on local firewalls and routers are properly monitored and controlled.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Black Start with Inverter-Based Resources: Hardware Testing

Black start, or grid restoration after a wide-spread power outage, is a critical service on the power system that has historically been provided by transmission-connected synchronous generators. As the power system transitions to rely on more distributed and inverter-based resources it will be critical that these resources can also provide black start services. In this work we investigated battery energy storage and solar photovoltaics technical capabilities and limitations to provide black start services through hardware testing in an experimental microgrid testbed. This hardware demonstration of inverter-based resources providing black start functions can help inform grid operators on how to include these types of resources in their black start plans.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Equivalent-Circuit Models of Grid-Forming IBRs for Electromagnetic-Transient Simulations: Preprint

We derive equivalent-circuit models of control- and physical-layer subsystems of grid-forming (GFM) inverter-based resources (IBRs) for electromagnetic-transient (EMT) simulations. Three different primary controllers are considered: droop, virtual synchronous machine (VSM), and dispatchable virtual oscillator control (dVOC). In addition, the models include cascaded voltage- and current-control loops, and LCL output filters. Simulations for a single-inverter setup and for a network of five inverters in a modified IEEE 14-bus topology are presented. The equivalent-circuit models simulated with analog electronic circuit-simulator software (in our case, LTspice) offer the same accuracy with up to 150x lower computational burden compared to block-diagram-based implementations in commercial off-the-shelf EMT software (in our case, MATLAB-Simulink).

circuit-equivalent model↗

Hierarchical Power Flow Control in Smart Grids: Enhancing Rotor Angle and Frequency Stability with Demand-Side Flexibility

Large-scale integration of renewables in power systems gives rise to new challenges for keeping synchronization and frequency stability in volatile and uncertain power flow states. To ensure the safety of operation, the system must maintain adequate disturbance rejection capability at the time scales of both rotor angle and system frequency dynamics. This calls for flexibility to be exploited on both the generation and demand sides, compensating volatility and ensuring stability at the two separate time scales. This article proposes a hierarchical power flow control architecture that involves both transmission and distribution networks as well as individual buildings to enhance both small-signal rotor angle stability and frequency stability of the transmission network. The proposed architecture consists of a transmission-level optimizer enhancing system damping ratios, a distribution-level controller following transmission commands and providing frequency support, and a building-level scheduler accounting for quality of service and following the distribution-level targets. Furthermore, we validate the feasibility and performance of the whole control architecture through real-time hardware-in-loop tests involving real-world transmission and distribution network models along with real devices at the Stone Edge Farm Microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Equivalent-Circuit Models of Grid-Forming IBRs for Electromagnetic-Transient Simulations

We derive equivalent-circuit models of control- and physical-layer subsystems of grid-forming (GFM) inverter-based resources (IBRs) for electromagnetic-transient (EMT) simulations. Three different primary controllers are considered: Droop, Virtual Synchronous Machine (VSM), and dispatchable Virtual Oscillator Control (dVOC). In addition, the models include cascaded voltage- and current-control loops, and LCL output filters. Simulations for a single-inverter setup and for a network of five inverters in a modified IEEE 14-bus topology are presented. The equivalent-circuit models simulated with analog electronic circuit-simulator software (in our case, LTspice) offer the same accuracy, and with no explicit tuning of the solver, lower computational burden compared to block-diagram-based implementations in commercial off-the-shelf EMT software (in our case, MATLAB-Simulink).

electromagnetic transient simulation↗

A review on protection challenges of Transmission Lines connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses.

14 SOLAR ENERGY↗

A Review on Protection Challenges of Transmission Lines Connected to Inverter-Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses

14 SOLAR ENERGY↗

Impact of Wide-Area Oscillation Damping Control using Measurement-Driven Approach on System Separation - Saudi Grid Case Study

In any interconnected power grid, low-frequency oscillations is a major problem that can limit the power transfer capability and deteriorate power system security due to potential low-damped or even undamped oscillations. Synchronized measurements provided by PMUs enable the design and development of wide-area oscillation damping controllers (WADC) based on measurement-driven model to overcome the limitations of traditional controllers. This work focuses on the impact of a W ADC based on a measurement-driven approach on system separation for the Saudi Electricity Company (SEC) grid. A grid model is provided by SEC for this study. Modal analysis is performed to identify the oscillation mode of interest for which the controller is designed. Damping the dominant oscillation mode helps slightly to improve transient stability of the system. Considering bus frequency at different locations in SEC's system as the candidate observation signals, the optimal observation signal is chosen for the W ADC by using the FFT method. The system transfer function model is constructed by utilizing probing measurements. Then, the W ADC parameters are calculated based on the identified model. The performance of the designed W ADC is tested under different contingencies.

Altarjami, Ibrahim↗

Status of SERT 2 thrusters and spacecraft 1976

The historical record of the SERT II ion thrusters and spacecraft performance for 6 1/2 years since the February 1970 launch is reviewed. The most recent ion thruster operation test shows no changes since 1974. Thruster 2 is fully operational with no performance degradation. Thruster 1 has a high voltage grid short, but continues to demonstrate cathode and discharge relight capability. Spacecraft orbit and dynamic analysis indicates a stable, sun-synchronous spacecraft orientation by 1979. An attitude adjustment maneuver was performed in August 1976 to achieve this orientation and provide sufficient continuous solar power for thruster operation in 1979.

Kerslake, W. R.↗

Status of SERT II thrusters and spacecraft - 1976

The historical record of the SERT II ion thrustors and spacecraft performance for 6-1/2 years since the February 1970 launch is reviewed. The most recent ion thrustor operation test shows no changes since 1974. Thrustor 2 is fully operational with no performance degradation. Thrustor 1 has a high voltage grid short, but continues to demonstrate cathode and discharge relight capability. Spacecraft orbit and dynamic analysis indicates a stable, sun-synchronous spacecraft orientation by 1979. An attitude adjustment maneuver was performed in August 1976 to achieve this orientation and provide sufficient continuous solar power for thrustor operation in 1979.

Kerslake, W. R.↗

Co-Simulation of PSS/E, OpenDSS, and PSCAD for Power Systems Stability Analysis With Inverter-Based Resources: Preprint

The increasing penetration of inverter-based resources (IBRs) is reshaping the dynamic behavior of power systems. IEEE standard 1547-2018 suggests that distributed energy resources (DERs) should provide grid services such as voltage and frequency supports. On the other hand, dynamic events caused by IBRs such as sub-synchronous oscillation have been reported. These developments necessitate improvement in the current modeling capabilities to better understand the interdependencies within power systems. These include interactions between transmission and distribution systems, among IBRs themselves, and between IBRs and conventional resources. In this paper, we present a co-simulation model integrating PSS/E, OpenDSS, and PSCAD to analyze IBR impacts on the stability of transmission and distribution systems. A key challenge in developing a co-simulation model is ensuring interoperability among different simulators (interfacing and data flow) while maintaining accurate results. Using the developed model, we simulate the impact of IBRs on power systems in two test cases: 1) fault ride through (FRT) capability during a generation trip contingency; 2) IBR-induced sub-synchronous oscillation. The results show the effectiveness of the co-simulation model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Oscillatory Spreading and Inertia in Power Grids

The increase in variable renewable generators (VRGs) in power systems has altered the dynamics from a historical experience. VRGs introduce new sources of power oscillations, and the stabilizing response provided by synchronous generators (SGs, e.g., natural gas, coal, etc.), which help avoid some power fluctuations, will lessen as VRGs replace SGs. These changes have led to the need for new methods and metrics to quickly assess the likely oscillatory behavior for a particular network without performing computationally expensive simulations. This work studies the impact of a critical dynamical parameter - the inertia value - on the rest of a power system's oscillatory response to representative VRG perturbations. We use a known localization metric in a novel way to quantify the number of nodes responding to a perturbation and the magnitude of those responses. This metric allows us to relate the spread and severity of a system's power oscillations with inertia. We find that as inertia increases, the system response to node perturbations transitions from localized (only a few close nodes respond) to delocalized (many nodes across the network respond). We introduce a heuristic computed from the network Laplacian to relate this oscillatory transition to the network structure. We show that our heuristic accurately describes the spread of oscillations for a realistic power-system test case. Using a heuristic to determine the likely oscillatory behavior of a system given a set of parameters has wide applicability in power systems, and it could decrease the computational workload of planning and operation.

dynamical systems↗

Open Source High Fidelity Modeling Of A Type-5 Wind Turbine Drivetrain

The purpose of this code is to provide a high-fidelity model of Type-5 wind turbine drivetrain for grid integration and transient stability studies. The increasing integration of renewable energy resources in evolving bulk power system (BPS) is impacting the system’s inertia. Type-5 wind turbine generation has the potential to behave like a traditional synchronous generator and can help mitigate the aforementioned impact. A hydraulic torque converter (TC) and gearbox with torque limiting feature are integral parts of a Type-5 wind turbine unit. A generic and high-fidelity model of a Type-5 wind turbine drivetrain is not openly and widely available for grid integration and transient stability studies. This hinders appropriate assessment of Type-5 wind power plant's contribution to the BPS resilience. This work develops and validates a TC model based on those generally used in automobile's transmission system.

Hussain, Tanveer↗

On requirements for a satellite mission to measure tropical rainfall

Tropical rainfall data are crucial in determining the role of tropical latent heating in driving the circulation of the global atmosphere. Also, the data are particularly important for testing the realism of climate models, and their ability to simulate and predict climate accurately on the seasonal time scale. Other scientific issues such as the effects of El Nino on climate could be addressed with a reliable, extended time series of tropical rainfall observations. A passive microwave sensor is planned to provide information on the integrated column precipitation content, its areal distribution, and its intensity. An active microwave sensor (radar) will define the layer depth of the precipitation and provide information about the intensity of rain reaching the surface, the key to determining the latent heat input to the atmosphere. A visible/infrared sensor will provide very high resolution information on cloud coverage, type, and top temperatures and also serve as the link between these data and the long and virtually continuous coverage by the geosynchronous meteorological satellites. The unique combination of sensor wavelengths, coverages, and resolving capabilities together with the low-altitude, non-Sun synchronous orbit provide a sampling capability that should yield monthly precipitation amounts to a reasonable accuracy over a 500- by 500-km grid.

Thiele, Otto W.↗

Delivery and application of precise timing for a traveling wave powerline fault locator system

The Bonneville Power Administration (BPA) has successfully operated an in-house developed powerline fault locator system since 1986. The BPA fault locator system consists of remotes installed at cardinal power transmission line system nodes and a central master which polls the remotes for traveling wave time-of-arrival data. A power line fault produces a fast rise-time traveling wave which emanates from the fault point and propagates throughout the power grid. The remotes time-tag the traveling wave leading edge as it passes through the power system cardinal substation nodes. A synchronizing pulse transmitted via the BPA analog microwave system on a wideband channel sychronizes the time-tagging counters in the remote units to a different accuracy of better than one microsecond. The remote units correct the raw time tags for synchronizing pulse propagation delay and return these corrected values to the fault locator master. The master then calculates the power system disturbance source using the collected time tags. The system design objective is a fault location accuracy of 300 meters. BPA's fault locator system operation, error producing phenomena, and method of distributing precise timing are described.

Street, Michael A.↗

Employing Interacting Qubits for Distributed Microgrid Control

To empower flexible and scalable operations, distributed control of multi-inverter microgrids, based on classical communication networks among distributed energy resources, has attracted considerable attention as it can guarantee synchronization and provide suitable remedies to the problem of improper power sharing. Notwithstanding this, resilience of the current schemes on classical communication makes microgrids vulnerable to cyber attacks. Inspired by recent revolutionary breakthroughs in quantum communication, in this paper, we devise a novel synchronization mechanism. We extend the synchronization framework utilized in distributed control algorithms to networks of quantum systems by generating pinning terms and coupling mechanism for the new synchronization rule via exploiting proper quantum jump operators and observables, and show that the quantum system will converge to a time-variant target state. Our devised quantum distributed controller (QDC) gives rise to a novel quantum communication scheme for distributed control of microgrids and enables microgrids to exploit the state-of-the-art quantum communication frameworks as communication infrastructure. Finally, test results on two representative AC and DC networked microgrids validate the efficacy and universality of the quantum distributed control.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗