Search NASA⌕ Search

SEARCH · Search NASA

Results for “guide tubes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Heat exchanger selection and design analyses for metal hydride heat pump systems

This paper presents a design analysis for the development of highly efficient heat exchangers within stationary metal hydride heat pumps. The design constraints and selected performance criteria are applied to three representative heat exchangers. The proposed thermal model can be applied to select the most efficient heat exchanger design and provides outcomes generally valid in a pre-design stage. Heat transfer effectiveness is the principal performance parameter guiding the selection analysis, the results of which appear to be mildly (up to 13%) affected by the specific Nusselt correlation used. The thermo-physical properties of the heat transfer medium and geometrical parameters are varied in the sensitivity analysis, suggesting that the length of independent tubes is the physical parameter that influences the performance of the heat exchangers the most. The practical operative regions for each heat exchanger are identified by finding the conditions over which the heat removal from the solid bed enables a complete and continuous hydriding reaction. The most efficient solution is a design example that achieves the target effectiveness of 95%.

08 HYDROGEN↗

Fiber-coupled Luminescence Dosimetry in Therapeutic and Diagnostic Radiology

Fiber-coupled luminescence dosimetry is an emerging technology with several potentially attractive features of relevance for uses in therapeutic and diagnostic radiology: direct water equivalence (i.e. no significant perturbation of the radiation field in a water phantom or a patient), sub-mm detector size, high dynamic range (below a mGy to several Gy), microsecond time resolution, and absence of electrical wires or other electronics in the dosimeter probe head. Fiber-coupled luminescence dosimetry systems typically consist of one or more small samples of phosphor, e.g. a mg of plastic scintillator, attached to 10-20 m long optical fiber cables of plastic. During irradiation, each dosimeter probe spontaneously emits radioluminescence (RL) in proportion to the dose rate. The luminescence intensity can be detected with photomultiplier tubes, CCD cameras or other highly sensitive photodetectors. Some crystalline phosphors, such as carbon-doped aluminium oxide (Al{sub 2}O{sub 3}:C) have the ability to store charge produced in the crystal during irradiation. The stored charge may later be released by fiber-guided laser light under emission of so-called optically stimulated luminescence (OSL). The OSL signal therefore reflects the passively integrated dose. In contrast to thermoluminescence dosimetry, fiber-coupled OSL dosimetry may be performed in vivo while the dosimeter is still in the patient. Within the last few years, several improvements and new applications of these techniques have been published, and the objective of this review is to provide an introduction to this field and to outline some of these new results. Emphasis will be given to applications in medical dosimetry such as in vivo real-time dose verification in brachytherapy and methods aimed for improved quality assurance of linear accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NUMERICAL SIMULATIONS OF THE MAGNETIC RAYLEIGH-TAYLOR INSTABILITY IN THE KIPPENHAHN-SCHLUeTER PROMINENCE MODEL

The launch of the Hinode satellite has allowed unprecedented high-resolution, stable images of solar quiescent prominences to be taken over extended periods of time. These new images led to the discovery of dark upflows that propagated from the base of prominences, developing highly turbulent profiles. As yet, how these flows are driven is not fully understood. To study the physics behind these phenomena, we use three-dimensional magnetohydrodynamic simulations to investigate the nonlinear stability of the Kippenhahn-Shlueter prominence model to the magnetic Rayleigh-Taylor instability. The model simulates the rise of a buoyant tube inside a quiescent prominence, where the upper boundary between the tube and prominence model is perturbed to excite the interchange of magnetic field lines. We found upflows of constant velocity (maximum found 6 km s{sup -1}) and a maximum plume width {approx}1500 km which propagate through a height of approximately 6 Mm in the no guide field case. The case with the strong guide field (initially B{sub y} = 2B{sub x} ) results in a large plume that rises through the prominence model at {approx}5 km s{sup -1} with width {approx}900 km (resulting in width of 2400 km when viewed along the axis of the prominence), reaching a height of {approx}3.1 Mm. In both cases, nonlinear processes were important for determining plume dynamics.

79 ASTRONOMY AND ASTROPHYSICS↗

System for slicing wafers

A newly patented process for slicing silicon wafers that has distinct advantages over methods now widely used is described. The primary advantage of the new system is that it allows the efficient slicing of a number of ingots simultaneously at high speed. The cutting action is performed mechanically, most often with diamond particles that are transported to the cutting zone by a fluid vehicle or have been made an integral part of the blade by plating or impregnation. The new system uses a multiple or ganged band saw, arranged and spaced so that each side, or length, segment of a blade element, or loop, provides a cutting function. Each blade is maintained precisely in position by guides as it enters and leaves each ingot. The cutting action is performed with a conventional abrasive slurry composed of diamond grit suspended in an oil- or water-based vehicle. The distribution system draws the slurry from the supply reservoir and pumps it to the injection tubes to supply it to each side of each ingot. A flush system is provided at the outer end of the work-station zone. In order to reduce potential damage, a pneumatically driven flushing fluid is provided.

Source record↗

Thermal-shock experiments for separate-effects validation of UO 2 fuel fracture models

Because of the important role that fracture plays in the behavior of ceramic UO2 fuel in a nuclear reactor environment, fracture models are a major component of fuel performance codes. As with any aspect of fuel performance, it is crucial to validate these fracture models against experimental data; however, obtaining well-controlled data for conditions representative of a reactor environment is difficult. Quenching is proposed here as a relatively simple approach for using a laboratory environment to achieve conditions that approximate those of a reactor environment. In this paper, an experimental apparatus containing a single instrumented fuel pellet in a sealed section of copper tubing is developed. It is then applied to a series of seven experiments in which the apparatus is first heated to a high temperature (580-680°C) by immersion in a molten salt bath, then quenched in a cold bath (-10-4 °C). Development of these experiments was guided by numerical simulations, and post-test simulations were performed to aid in understanding the experimental behavior and assessing the accuracy of the predictions of fracture initiation and propagation. In addition, similar experiments were performed on solid copper rods to provide temperature-dependent heat transfer coefficients for use in simulations of these experiments. Here, this study demonstrates that quenching is a viable approach for generating thermal gradients representative of those in prototypical light-water reactor conditions at powers of about 5–10 kW/m. Fracture is expected to begin at these power levels, and moderate amounts of radial and axial cracking was observed in these quenching tests.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

3D Printable Polymers for Radiological Applications

Additive manufacturing of polymers is a widely used and growing technology throughout the DOE complex. Composite filaments for Fused Deposition Modeling (FDM) printers are commonly used to enhance material properties such as mechanical strength, operating temperature and chemical resistance. Radio luminescent properties were added to 3D filaments by impregnating clear poly(ethylene terephthalate)-glycol (PETG) with X-ray scintillator powder. X-ray scintillators have unique, narrow emission spectra which can be imaged with low light DSLR cameras, photomultiplier tubes, or spectrometers. Filament Production: 1. Pellets are loaded into the hopper. 2. Temperature and extrusion speed are set on extruder. 3. Extruder turned on and filament is pulled from nozzle along air path to cool. 4. Spooler drive speeds set. 5. Filament is inserted through Filameasure then guided along drive wheels and into traverse. 6. Parameters adjusted to obtain 1.75 mm diameter 7. Filament is inserted into spooler wheel. Traverse speed set and slip nut adjusted to make tight and even roll. From Raw Materials to Printed Part: Clear PETG pellets were dipped in ZnS:Cu scintillator powder to coat pellets. Coated and uncoated pellets were mixed together before inserting into hopper. Filament showed trace amounts of powder and luminesced under UV light. Powder distribution is random and not reproducible thus providing a unique identification marker potentially useful for national security applications. Multiple X-ray scintillators can be arranged in a panel to discriminate incident X-ray photon energies. Variable panel arrangement: pixelated, layered, solid from homogenous filament. Ratio of emission intensities. Response varies with incident photon energy. Spectrally separate scintillators. Scintillators: Yttrium Oxide Europium Doped - Red, Gadolinium Oxysulfide Terbium Doped - Green, Barium Magnesium Aluminate Europium Doped - Blue, Zinc Sulfide Copper Doped - Green. Powder concentrations will need to be increased in the filament for use in the energy discriminating panel. Homogeneity in the filament will be a challenge that can be solved by turning the pellets into a powder and mixing it with scintillator powder prior to extrusion. The panels will be tested using x-ray booths and button sources such as Am-241, Cs-137, and Co-60.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A user's guide to the PLTEMP/ANL code.

PLTEMP/ANL V4.1 is a FORTRAN program that obtains a steady-state flow and temperature solution for a nuclear reactor core, or for a single fuel assembly. It is based on an evolutionary sequence of ''PLTEMP'' codes in use at ANL for the past 20 years. Fueled and non-fueled regions are modeled. Each fuel assembly consists of one or more plates or tubes separated by coolant channels. The fuel plates may have one to five layers of different materials, each with heat generation. The width of a fuel plate may be divided into multiple longitudinal stripes, each with its own axial power shape. The temperature solution is effectively 2-dimensional. It begins with a one-dimensional solution across all coolant channels and fuel plates/tubes within a given fuel assembly, at the entrance to the assembly. The temperature solution is repeated for each axial node along the length of the fuel assembly. The geometry may be either slab or radial, corresponding to fuel assemblies made of a series of flat (or slightly curved) plates, or of nested tubes. A variety of thermal-hydraulic correlations are available with which to determine safety margins such as Onset-of-Nucleate boiling (ONB), departure from nucleate boiling (DNB), and onset of flow instability (FI). Coolant properties for either light or heavy water are obtained from FORTRAN functions rather than from tables. The code is intended for thermal-hydraulic analysis of research reactor performance in the sub-cooled boiling regime. Both turbulent and laminar flow regimes can be modeled. Options to calculate both forced flow and natural circulation are available. A general search capability is available (Appendix XII) to greatly reduce the reactor analyst's time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A User's Guide to the PLTEMP/ANL Code

PLTEMP/ANL V4.2 is a FORTRAN program that obtains a steady-state flow and temperature solution for a nuclear reactor core, or for a single fuel assembly. It is based on an evolutionary sequence of ''PLTEMP'' codes in use at ANL for the past 20 years. Fueled and non-fueled regions are modeled. Each fuel assembly consists of one or more plates or tubes separated by coolant channels. The fuel plates may have one to five layers of different materials, each with heat generation. The width of a fuel plate may be divided into multiple longitudinal stripes, each with its own axial power shape. The temperature solution is effectively 2-dimensional. It begins with a one-dimensional solution across all coolant channels and fuel plates/tubes within a given fuel assembly, at the entrance to the assembly. The temperature solution is repeated for each axial node along the length of the fuel assembly. The geometry may be either slab or radial, corresponding to fuel assemblies made of a series of flat (or slightly curved) plates, or of nested tubes. A variety of thermal-hydraulic correlations are available with which to determine safety margins such as Onset-of- Nucleate boiling (ONB), departure from nucleate boiling (DNB), and onset of flow instability (FI). Coolant properties for either light or heavy water are obtained from FORTRAN functions rather than from tables. The code is intended for thermal-hydraulic analysis of research reactor performance in the sub-cooled boiling regime. Both turbulent and laminar flow regimes can be modeled. Options to calculate both forced flow and natural circulation are available. A general search capability is available (Appendix XII) to greatly reduce the reactor analyst’s time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-E-E-06: Teaching Medical Physics in a Radiology Museum

Purpose: To enhance the learning process in the teaching of medical physics by providing a venue to experience the historical equipment and devices of radiology. Methods: We have created a museum by assembling a large collection of equipment and artifacts related to radiology and medical physics. As part of a learning-in-context educational approach, classes for a survey course in medical physics are held in the museum so that students are able to visually and tangibly experience the implements of radiology, while related topics are discussed. The students learn how x-ray equipment and techniques evolved throughout the years and they learn to appreciate the differences and similarities between current x-ray technology and that of the early days. The collection contains items dating from the era of the discovery of x-rays up to recent times and includes gas x-ray tubes, hand-held fluoroscopes, generators, spark-gap kV meters, stereoscopes, glass-plate radiographs, a photofluorographic unit, wood-interspaced grid, flat-panel detector, linear-accelerator klystron, and brachytherapy radium applicators, as well as an extensive library containing some of the seminal literature of the field so that students can delve deeper into the technology. In addition to the classes, guided tours are provided for radiologic-technology, bioengineering, physics and medical students, as well as group and individual tours for the general public. Results: Student course assessments have consistently included positive expressions of their experience in the museum. Numerous students have volunteered to assist with display preparation and have learned by researching the content. Many individuals have been attracted on a walk-in basis and have expressed a deep curiosity in the technology, with positive feedback. Conclusion: The museum and its artifacts have been invaluable in stimulating interest in the history and technology of medical physics. Students and visitors alike obtain a deeper appreciation of the contribution physics has made to medicine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experiments planned specifically for developing turbulence models in computations of flow fields around aerodynamic shapes

Building block experiments and companion numerical simulations intended to verify and guide turbulence modeling are described. A series of experiments and computations being used to enhance modeling development for the shock wave turbulent boundary layer interaction problem is emphasized. Results are given for transonic flow over a circular arc airfoil undergoing shock wave induced, boundary layer separation for supersonic flow along a tube wall undergoing normal shock wave induced, boundary layer separation. Experimental data which use the complete Navier-Stokes equations are discussed.

Marvin, J. G.↗

A User’s Guide to the PLTEMP/ANL Code

PLTEMP/ANL V4.2 is a program that obtains a steady-state flow and temperature solution for a nuclear reactor core, or for a single fuel assembly. It is based on an evolutionary sequence of codes originally used for plate temperatures, hence “PLTEMP”, developed at Argonne National Laboratory over several decades. Fueled and non-fueled regions are modeled. Each fuel assembly consists of one or more plates or tubes separated by coolant channels. The fuel plates may have one to five layers of different materials, each with heat generation. The width of a fuel plate may be divided into multiple longitudinal stripes, each with its own axial power shape. The temperature solution is effectively 2-dimensional. It begins with a one-dimensional solution across all coolant channels and fuel plates or tubes within a given fuel assembly, at the entrance to the assembly. The temperature solution is repeated for each axial node along the length of the fuel assembly. The geometry may be either slab or radial, corresponding to fuel assemblies made of a series of flat (or slightly curved) plates, or of nested tubes. A variety of thermal-hydraulic correlations are available with which to determine safety margins such as onset-of-nucleate boiling ratio(ONBR), departure from nucleate boiling ratio (DNBR), and onset of flow instability ratio (OFIR). Coolant properties for either light or heavy water are obtained from FORTRAN functions rather than from tables. The code is intended for thermal-hydraulic analysis of research reactor performance in the sub-cooled boiling regime. Both turbulent and laminar flow regimes can be modeled. Options to calculate both forced flow and natural circulation are available. A general search capability is available (Appendix XII) to greatly reduce the reactor analyst’s time.

97 MATHEMATICS AND COMPUTING↗

A User’s Guide to the PLTEMP/ANL Code

PLTEMP/ANL V4.3 is a program that obtains a steady-state flow and temperature solution for a nuclear reactor core, or for a single fuel assembly. It is based on an evolutionary sequence of codes originally used for plate temperatures, hence “PLTEMP”, developed at Argonne National Laboratory over several decades. Fueled and non-fueled regions are modeled. Each fuel assembly consists of one or more plates or tubes separated by coolant channels. The fuel plates may have one to five layers of different materials, each with heat generation. The width of a fuel plate may be divided into multiple longitudinal stripes, each with its own axial power shape. Depending upon the heat transfer method selected, the temperature solution is effectively 2-dimensional or 3-dimensional (Appendix XV). It begins with a solution across all coolant channels and fuel plates or tubes within a given fuel assembly, at the entrance to the assembly. The temperature solution is repeated for each axial node along the length of the fuel assembly. The geometry may be either slab or radial, corresponding to fuel assemblies made of a series of flat (or slightly curved) plates, or of nested tubes. A variety of thermal-hydraulic correlations are available to determine safety margins such as onset-of-nucleate boiling ratio(ONBR), departure from nucleate boiling ratio (DNBR), and onset of flow instability ratio (OFIR). Coolant properties for either light or heavy water are obtained from FORTRAN functions rather than from tables. The code is intended for thermal-hydraulic analysis of research reactor performance in the sub-cooled boiling regime. Both turbulent and laminar flow regimes can be modeled. Options to calculate both forced flow and natural circulation are available. A general search capability is available (Appendix XII) to greatly reduce the reactor analyst’s time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A User’s Guide to the PLTEMP/ANL Code

PLTEMP/ANL V4.3 is a program that obtains a steady-state flow and temperature solution for a nuclear reactor core, or for a single fuel assembly. It is based on an evolutionary sequence of codes originally used for plate temperatures, hence “PLTEMP”, developed at Argonne National Laboratory over several decades. Fueled and non-fueled regions are modeled. Each fuel assembly consists of one or more plates or tubes separated by coolant channels. The fuel plates may have one to five layers of different materials, each with heat generation. The width of a fuel plate may be divided into multiple longitudinal stripes, each with its own axial power shape. Depending upon the heat transfer method selected, the temperature solution is effectively 2-dimensional or 3-dimensional (Appendix XV). It begins with a solution across all coolant channels and fuel plates or tubes within a given fuel assembly, at the entrance to the assembly. The temperature solution is repeated for each axial node along the length of the fuel assembly. The geometry may be either slab or radial, corresponding to fuel assemblies made of a series of flat (or slightly curved) plates, or of nested tubes. A variety of thermal-hydraulic correlations are available to determine safety margins such as onset-of-nucleate boiling ratio(ONBR), departure from nucleate boiling ratio (DNBR), and onset of flow instability ratio (OFIR). Coolant properties for either light or heavy water are obtained from FORTRAN functions rather than from tables. The code is intended for thermal-hydraulic analysis of research reactor performance in the sub-cooled boiling regime. Both turbulent and laminar flow regimes can be modeled. Options to calculate both forced flow and natural circulation are available. A general search capability is available (Appendix XII) to greatly reduce the reactor analyst’s time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A User’s Guide to the PLTEMP/ANL Code (V.4.3)

PLTEMP/ANL V4.3 is a program that obtains a steady-state flow and temperature solution for a nuclear reactor core, or for a single fuel assembly. It is based on an evolutionary sequence of codes originally used for plate temperatures, hence “PLTEMP”, developed at Argonne National Laboratory over several decades. Fueled and non-fueled regions are modeled. Each fuel assembly consists of one or more plates or tubes separated by coolant channels. The fuel plates may have one to five layers of different materials, each with heat generation. The width of a fuel plate may be divided into multiple longitudinal stripes, each with its own axial power shape. Depending upon the heat transfer method selected, the temperature solution is effectively 2-dimensional or 3-dimensional (Appendix XV). It should be noted that for a 3-dimensional solution the axial power shape is modeled without accounting for axial heat conduction. It begins with a solution across all coolant channels and fuel plates or tubes within a given fuel assembly, at the entrance to the assembly. The temperature solution is repeated for each axial node along the length of the fuel assembly. The geometry may be either slab or radial, corresponding to fuel assemblies made of a series of flat (or slightly curved) plates, or of nested tubes. A variety of thermal-hydraulic correlations are available to determine safety margins such as onset-of-nucleate boiling ratio(ONBR), departure from nucleate boiling ratio (DNBR), and onset of flow instability ratio (OFIR). Coolant properties for either light or heavy water are obtained from FORTRAN functions rather than from tables. The code is intended for thermal-hydraulic analysis of research reactor performance in the sub-cooled boiling regime. Both turbulent and laminar flow regimes can be modeled. Options to calculate both forced flow and natural circulation are available. A general search capability is available (Appendix XII) to greatly reduce the reactor analyst’s time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Netrin-4 regulates angiogenic responses and tumor cell growth

Netrin-4 is a 628 amino acid basement membrane component that promotes neurite elongation at low concentrations but inhibits neurite extension at high concentrations. There is a growing body of literature suggesting that several molecules, including netrins, are regulators of both neuronal and vascular growth. It is believed that molecules that guide neural growth and development are also involved in regulating morphogenesis of the vascular tree. Further, netrins have recently been implicated in controlling epithelial cell branching morphogenesis in the breast, lung and pancreas. Characterization of purified netrin-4 in in vitro angiogenesis assays demonstrated that netrin-4 markedly inhibits HMVEC migration and tube formation. Moreover, netrin-4 inhibits proliferation of a variety of human tumor cells in vitro. Netrin-4 has only modest effects on proliferation of endothelial and other non-transformed cells. Netrin-4 treatment results in phosphorylation changes of proteins that are known to control cell growth. Specifically, Phospho-Akt-1, Phospho-Jnk-2, and Phospho-c-Jun are reduced in tumor cells that have been treated with netrin-4. Together, these data suggest a potential role for netrin-4 in regulating tumor growth.

60 APPLIED LIFE SCIENCES↗

Automatic image guidance for prostate IMRT using low dose CBCT

Purpose: Varian's On-Board Imager is a linac-integrated cone-beam CT (CBCT) system used at the authors' institution to acquire images prior to delivering each fraction of prostate intensity modulated radiotherapy. The images are used to determine a couch shift that realigns the tumor with the position obtained in the planning CT. However, this manual image-guided radiotherapy (IGRT) technique is operator dependent, time consuming, offers limited degrees of freedom, and requires significant imaging dose over the course of treatment. To overcome these problems, the authors propose two fully automatic IGRT techniques that require significantly less imaging dose. Methods: Dose is reduced by lowering the x-ray tube mA s during CBCT acquisition at the cost of increasing image noise. In ''forward'' IGRT, the CBCT image is automatically registered to the planning CT to obtain the necessary couch shift. The ''reverse'' technique offers additional degrees of freedom as it involves nonrigid registration of the planning CT to the CBCT. Both techniques were evaluated using images of an anthropomorphic phantom with simulated motion and by retrospectively analyzing data from ten prostate cancer patients. Results: IGRT error for the phantom data at 100% relative imaging dose was 8.2{+-}3.7, 3.5{+-}1.2, and 2.1{+-}0.6 mm for setup only, forward, and reverse techniques, respectively. For patient images acquired at 100% relative imaging dose, the errors were 5.4{+-}1.7, 5.0{+-}1.6, 5.0{+-}2.0, and 4.0{+-}1.6 mm for setup only, manual forward (performed clinically), automatic forward, and reverse IGRT, respectively. Furthermore, imaging dose could be reduced to 20% without a significant loss in image guidance accuracy. Conclusions: The presented image guidance methods are accurate while requiring only 20% of the standard imaging dose. The combination of low dose, automation, and accuracy enables frequent corrections during treatment, possibly leading to reduced margins and improved treatment outcomes.

60 APPLIED LIFE SCIENCES↗

Device for Automated Cutting and Transfer of Plant Shoots

A device that enables the automated cutting and transfer of plant shoots is undergoing development for use in the propagation of plants in a nursery or laboratory. At present, it is standard practice for a human technician to use a knife and forceps to cut, separate, and grasp a plant shoot. The great advantage offered by the present device is that its design and operation are simpler than would be those of a device based on the manual cutting/separation/grasping procedure. [The present device should not be confused with a prior device developed for partly the same purpose and described in Compliant Gripper for a Robotic Manipulator (NPO-21104), NASA Tech Briefs, Vol. 27, No. 3 (March 2003), page 59.]. The device (see figure) includes a circular tube sharpened at its open (lower) end and mounted on a robotic manipulator at its closed (upper) end. The robotic manipulator simply pushes the sharpened open end of the tube down onto a bed of plants and rotates a few degrees clockwise then counterclockwise about the vertical axis, causing the tube to cut a cylindrical plug of plant material. Exploiting the natural friction between the tube and plug, the tube retains the plug, without need for a gripping mechanism and control. The robotic manipulator then retracts the tube, translates it to a new location over a plant-growth tray, and inserts the tube part way into the growth medium at this location in the tray. A short burst of compressed air is admitted to the upper end of the tube to eject the plug of plant material and drive it into the growth medium. A prototype has been tested and verified to function substantially as intended. It is projected that in the fully developed robotic plant-propagation system, the robot control system would include a machine- vision subsystem that would automatically guide the robotic manipulator in choosing the positions from which to cut plugs of plant material. Planned further development efforts also include more testing and refinement of the design and operation described above.

Cipra, Raymond↗