Search NASA⌕ Search

SEARCH · Search NASA

Results for “heat exchanger”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Ultra-compact and efficient heat exchanger for solar desalination with unprecedented scaling resistance

The objective is to design, prototype, and test a heat exchanger technology with an efficiency improvement of more than 150% compared to state-of-the-art heat exchanger technology (UA/volume), with significantly improved fouling/scaling resistance at elevated temperatures (>120°C) when compared to existing technology where scaling is a major performance-limiting issue, as well as at lower operating-temperatures (~63-110°C). We now report our overall progress on the project. An ultra-compact, efficient heat exchanger geometry has been developed that can maximize surface-area-to-volume ratio so that proposed target (UA/volume). Advanced manufacturing techniques, such additive manufacturing, have made it possible to create complex structures cost effectively. In addition to traditional manufacturing methods, additive manufacturing has been successfully used for the development of high-performance geometries. These methods allow the ability to create custom surface textures, which are deployed to dramatically control wettability and create energy-gradient surfaces. These techniques allow fouling/scaling nucleation to be spatially controlled, such that as the fouling layer grows it will be broken and removed by flow forces.

42 ENGINEERING↗

Design Development Analyses in Support of a Heatpipe-Brayton Cycle Heat Exchanger

One of the power systems under consideration for nuclear electric propulsion or as a planetary surface power source is a heatpipe-cooled reactor coupled to a Brayton cycle. In this system, power is transferred from the heatpipes to the Brayton gas via a heat exchanger attached to the heatpipes. This paper discusses the fluid, thermal and structural analyses that were performed in support of the design of the heat exchanger to be tested in the SAFE-100 experimental program at Marshall Space Flight Center. A companion paper, "Mechanical Design and Fabrication of a SAFE-100 Heat Exchanger for use in NASA s Advanced Propulsion Thermal-hydraulic Simulator", presents the fabrication issues and prototyping studies that, together with these analyses, led to the development of this heat exchanger. An important consideration throughout the design development of the heat exchanger was its capability to be utilized for higher power and temperature applications. This paper also discusses this aspect of the design and presents designs for specific applications that are under consideration.

Steeve, Brian↗

Design Development Analyses in Support of a Heatpipe-Brayton Cycle Heat Exchanger

One of the power systems under consideration for nuclear electric propulsion or as a planetary surface power source is a heatpipe-cooled reactor coupled to a Brayton cycle. In this system, power is transferred from the heatpipes to the Brayton gas via a heat exchanger attached to the heatpipes. This paper discusses the fluid, thermal and structural analyses that were performed in support of the design of the heat exchanger to be tested in the SAFE-100 experimental program at Marshall Space Flight Center. A companion paper, "Mechanical Design and Fabrication of a SAFE-100 Heat Exchanger for use in NASA s Advanced Propulsion Thermal-hydraulic Simulator", presents the fabrication issues and prototyping studies that, together with these analyses, led to the development of this heat exchanger. An important consideration throughout the design development of the heat exchanger was its capability to be utilized for higher power and temperature applications. This paper also discusses this aspect of the design and presents designs for specific applications that are under consideration.

Steeve, Brian↗

Self-Protecting Heat Exchanger

Double-wall heat-exchanger tube protects from overloads by changing thermal resistance automatically. When temperature at any location on tube increases above prescribed limit, thermal resistance through walls of tube increases at location. Prevents local excess heat load from overheating tube or boosting internal pressure and weakening tube, shortening life expectancy, or destroying it. When heat load falls to normal level, tube automatically lowers thermal resistance and resumes heat exhange at rated capacity.

Wagner, William R.↗

Conceptual Design of a Condensing Heat Exchanger for Space Systems Using Porous Media

Condensing heat exchangers are used in many space applications in the thermal and humidity control systems. In the International Space Station (ISS), humidity control is achieved by using a water cooled fin surface over which the moist air condenses, followed by "slurper bars" that take in both the condensate and air into a rotary separator and separates the water from air. The use of a cooled porous substrate as the condensing surface provides and attractive alternative that combines both heat removal as well as liquid/gas separation into a single unit. By selecting the pore sizes of the porous substrate a gravity independent operation may also be possible with this concept. Condensation of vapor into and on the porous surface from the flowing air and the removal of condensate from the porous substrate are the critical processes involved in the proposed concept. This paper describes some preliminary results of the proposed condensate withdrawal process and discusses the on-going design and development work of a porous media based condensing heat exchanger at the NASA Glenn Research Center in collaboration with NASA Johnson Space Center.

Hasan, Mohammad M.↗

Water Based Phase Change Material Heat Exchanger Development

In a cyclical heat load environment such as low Lunar orbit, a spacecraft’s radiators are not sized to reject the full heat load requirement. Traditionally, a supplemental heat rejection device (SHReD) such as an evaporator or sublimator is used to act as a “topper” to meet the additional heat rejection demands. Utilizing a Phase Change Material (PCM) heat exchanger (HX) as a SHReD provides an attractive alternative to evaporators and sublimators as PCM HXs do not use a consumable, thereby leading to reduced launch mass and volume requirements. Studies conducted in this paper investigate utilizing water’s high latent heat of formation as a PCM, as opposed to traditional waxes, and corresponding complications surrounding freezing water in an enclosed volume. Work highlighted in this study is primarily visual and includes understanding ice formation, freeze front propagation, and the solidification process of water/ice. Various test coupons were constructed of copper to emulate the interstitial pin configuration (to aid in conduction) of the proposed water PCM HX design. Construction of a prototypic HX was also completed in which a flexible bladder material and interstitial pin configurations were tested. Additionally, a microgravity flight was conducted where three copper test articles were frozen continuously during microgravity and 2-g periods and individual water droplets were frozen during microgravity.

Hansen, Scott W.↗

Fitness For Service Assessment of a Corroded Heat Exchanger

Within the Fermi National Accelerator complex, there exist various water systems that support accelerator operations. One of these systems is extremely vital to the operation of the machine; that is the cooling system. The cooling system consists of nine relatively large heat exchangers that take untreated pond water and use it to cool the process fluid that further cools machine components. Over the 30 years these heat exchangers have been in operation, they have undergone significant material loss on the channels. This material loss, due to various forms of corrosion such as galvanic and microbiologically influenced corrosion (MIC) and possibly others, has deteriorated more than 80% of the nominal wall thickness of some of the exchangers and placed them in a questionable state. ASME FFS-1 (API 579) has been applied to address the condition of the heat exchangers due to their noncompliance with the governing code, BPVC Sec. VIII Div. 1. The assessments encompassed ASME FFS-1 parts 4: General Metal Loss and 9: Crack Like Flaw using level 1, 2, and 3 analysis techniques based on inspection data obtained by API 510 inspections. Level 1 and 2 assessments were deemed unfit for the corroded regions due to their location relative to a major structural discontinuity (channel to tube-sheet joint), so a level 3 analysis was conducted according to ASME Sec. VIII Div. 2 (design by analysis) rules for pressure vessels. Supplemental information included pond water tests to determine an accurate future corrosion allowance due to lacking inspection history. A leak before break (LBB) route was chosen to evaluate the possibility of leaking prior to the onset of failure. The analysis of one heat exchanger shows that the possibility the channel will develop a pinhole leak over 2.5 more years of operation should not be overlooked, but burst was unlikely from operation. The use of fracture mechanics show, that if a through-wall crack were to develop, it would not propagate further than the channel geometry and cause a leak not greater than 35 GPM. Using ASME Section XI Code Case N-705-1, allowing us to operate with a leak until the next outage given certain operating conditions and developing a leak mitigation procedure, this heat exchanger is deemed fit-for-service.

Humenik, Alex [Fermilab]↗

Coupled heat and mass transfer in internally cooled silica gel-coated aluminum foam heat exchangers for dehumidification

Solid desiccant dehumidifiers offer significant potential to improve humidity control in buildings due to their ability to independently regulate latent (humidity) and sensible (temperature) loads. However, adsorption of water vapor by desiccants is an exothermic process; the resulting heat of adsorption increases both the desiccant bed temperature and the temperature of the air flowing over the bed, thereby limiting the performance of desiccant dehumidifiers. To address this problem, desiccant-coated heat exchanger prototypes were developed by coating silica gel onto aluminum foam substrates and integrated with chilled water circulation for effective removal of the heat of adsorption. Prototype heat exchangers with two different pore densities (10 and 20 pores per inch (PPI)) and two different desiccant loadings (∼10.36% and ∼17.80%) were fabricated. Experiments were conducted by varying the inlet air face velocity, chilled water inlet temperature, and chilled water flow rate to investigate the coupled heat and mass transfer characteristics of the prototype heat exchangers over a wide range of operating conditions. The underlying transport mechanisms were analyzed using transient desiccant bed temperature, outlet air temperature, and outlet humidity profiles. The results demonstrate that internal cooling significantly enhances dehumidification performance by maintaining more favorable thermodynamic conditions for water vapor adsorption. Under identical operating conditions, a 20 PPI heat exchanger coated with 25.05 g of silica gel achieved 98.98% higher cumulative water uptake and 97.75% higher moisture removal capacity than the corresponding non-cooled case after 5 min of adsorption. This substantial enhancement was further supported by a validated one-dimensional coupled heat and mass transfer model developed in the present study. To date, this is one of the first experimental studies to systematically investigate the combined effects of internal cooling, foam pore density, and desiccant loading on the performance of silica-gel-coated metal foam heat exchangers under HVAC-relevant operating conditions.

42 ENGINEERING↗

Design, optimization, and validation of a triply periodic minimal surface based heat exchanger for extreme temperature applications

Heat exchanger (HX) innovation offers potential for significant improvements in energy efficiency for a host of applications including but not limited to aviation and power generation cycles. Triply Periodic Minimal Surfaces (TPMS) have received significant attention in recent years due to their incredibly high surface area density, which makes them very attractive from a heat transfer point of view. Recent efforts have largely focused on thermal-hydraulic characterization of the many available TPMS and the testing of small-scale HX prototypes. However, practical implementation remains largely unexplored, partially due to the extreme computational cost associated with accurately simulating these complex structures. In this work, we present the design, simulation, and optimization of a TPMS-HX for high temperature (900 °C) and pressure (25 MPa) applications. Detailed analysis of HX sub-sections is conducted to define the smallest repeatable section which may be used to characterize the thermal-hydraulic performance of the entire HX, enabling rapid design and iteration with significantly reduced computational cost. Compared to preliminary results for a water-to-water experiment, calibrated heat transfer and pressure drop predictions were within ±5 % and ±10 %, respectively. Optimization results show a 10x increase in volumetric power density over the initial design, which is verified against a parametric exhaustive search of the HX design space. Furthermore, it was found that reducing the unit cell hydraulic diameter cell plays the largest role in increasing heat transfer, increasing the surface area density and enabling a more compact and efficient HX.

42 ENGINEERING↗

Surface Roughness Effects on Heat Transfer in Additively Manufactured sCO 2 Cycle Heat Exchangers

An experimental study was performed to consider the impact of surface roughness on heat transfer and pressure drop to supercritical carbon dioxide (sCO 2 ) in additively manufactured channels. All tests were performed in the Heat Exchange and Experimental Testing (HEET) rig at the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) in Morgantown, West Virginia. Four test articles were considered. The first was a hydrodynamically smooth, drawn tube. The other three were additively manufactured channels with square and rectangular cross sections, which were characterized by sand-grain roughness to hydraulic diameter ratios spanning 0.0029 to 0.0073. Friction factors were determined by measuring the tube mass flow rate and pressure drop. The tube side heat transfer coefficient was measured using the Wilson plot technique. It was found that the friction factor results were 8% greater than the Colebrook correlation. Greater deviation was observed between the heat transfer results and the correlations. The Gnielinski correlation overpredicted the experimental points by nominally 30% and the Norris correlation overpredicting the experimental points by nominally 25%. A thermal performance factor was formed from the friction factor augmentation and Nusselt number augmentation results. These results indicated a 10% improvement in heat duty for a heat exchanger constructed utilizing a tube with ϵ/D_h =0.0073 relative to a heat exchanger utilizing a smooth, conventional tube.

36 MATERIALS SCIENCE↗

Optimization of Refrigerant Compositions for Low-GWP Refrigerant Mixtures Using Segment-by-segment Heat Exchanger and Detailed System Models

The recently introduced hydrofluoroolefin (HFO) refrigerants, including R1234yf and R1234ze(E), have significantly lower global warming potentials (GWPs) than traditional hydrofluorocarbon (HFC) refrigerants like R410A. However, prior tests show that direct drop-in of pure R1234yf or R1234ze(E) into equipment designed for R410A results in a decrease in heat exchanger capacity and the system coefficient of performance. The primary reason is the lower in-tube heat transfer performance of R1234yf and R1234ze(E) compared with that of R410A. To address this issue, previous studies have mixed the mildly flammable HFC R32 with HFOs to improve system performance, with HFC R125 also added to suppress flammability. Previous studies selected compositions based on simple cycle analyses and did not consider modifications of the heat exchanger circuitry configuration to adapt to the new refrigerants. This study presents a novel multi-objective optimization approach to design a refrigerant composition that maximizes energy efficiency within flammability and GWP limits. The approach in this work simultaneously optimizes mixture composition and heat exchanger circuitry configuration. A case study on a rooftop unit indicates that, compared with mixture-only optimization, simultaneous optimization of mixture and heat exchanger circuitry yields a 5.9% improvement in cycle efficiency and a 48.6% reduction in refrigerant flammability with a GWP of 268. Circuitry optimization using refrigerants with different temperature glides shows that the larger the temperature glide is, the larger EER improvement is obtained. The results show that zeotropic blends with a large temperature glide are more sensitive to the refrigerant circuitry than pure refrigerants and may suffer significant performance degradation with subpar heat exchanger circuitry design. The proposed optimization approach is generally applicable to mixtures with any number of components. Using this approach to design a HVAC system can yield higher system efficiency within flammability and GWP constraints.

Li, Zhenning↗

Continued Water-Based Phase Change Material Heat Exchanger Development

In a cyclical heat load environment such as low Lunar orbit, a spacecraft's radiators are not sized to reject the full heat load requirement. Traditionally, a supplemental heat rejection device (SHReD) such as an evaporator or sublimator is used to act as a "topper" to meet the additional heat rejection demands. Utilizing a Phase Change Material (PCM) heat exchanger (HX) as a SHReD provides an attractive alternative to evaporators and sublimators as PCM HXs do not use a consumable, thereby leading to reduced launch mass and volume requirements. In continued pursuit of water PCM HX development two full‐scale, Orion sized water‐based PCM HX's were constructed by Mezzo Technologies. These HX's were designed by applying prior research and experimentation to the full scale design. Design options considered included bladder restraint and clamping mechanisms, bladder manufacturing, tube patterns, fill/drain methods, manifold dimensions, weight optimization, and midplate designs. Design and construction of these HX's led to successful testing of both PCM HX's.

Hansen, Scott↗

Continued Water-Based Phase Change Material Heat Exchanger Development

In a cyclical heat load environment such as low Lunar orbit, a spacecraft's radiators are not sized to meet the full heat rejection demands. Traditionally, a supplemental heat rejection device (SHReD) such as an evaporator or sublimator is used to act as a "topper" to meet the additional heat rejection demands. Utilizing a Phase Change Material (PCM) heat exchanger (HX) as a SHReD provides an attractive alternative to evaporators and sublimators as PCM HX's do not use a consumable, thereby leading to reduced launch mass and volume requirements. In continued pursuit of water PCM HX development two full-scale, Orion sized water-based PCM HX's were constructed by Mezzo Technologies. These HX's were designed by applying prior research on freeze front propagation to a full-scale design. Design options considered included bladder restraint and clamping mechanisms, bladder manufacturing, tube patterns, fill/drain methods, manifold dimensions, weight optimization, and midplate designs. Two units, Units A and B, were constructed and differed only in their midplate design. Both units failed multiple times during testing. This report highlights learning outcomes from these tests and are applied to a final sub-scale PCM HX which is slated to be tested on the ISS in early 2017.

Hansen, Scott W.↗

Heat transfer and pressure drop performance of a finned-tube heat exchanger proposed for use in the NASA Lewis Altitude Wind Tunnel

A segment of the heat exchanger proposed for use in the NASA Lewis Altitude Wind Tunnel (AWT) facility has been tested under dry and icing conditions. The heat exchanger has the largest pressure drop of any component in the AWT loop. It is therefore critical that its performance be known at all conditions before the final design of the AWT is complete. The heat exchanger segment is tested in the NASA Lewis Icing Research Tunnel (IRT) in order to provide an icing cloud environment similar to what will be encountered in the AWT. Dry heat transfer and pressure drop data are obtained and compared to correlations available in the literature. The effects of icing sprays on heat transfer and pressure drop are also investigated.

Vanfossen, G. J.↗

Advanced interface heat exchangers for the Space Station main thermal bus

Future evolution and growth of the Space Station will place increasing demands on the thermal management system by the addition of new payloads and from increased activity in the habitat modules. To meet this need, Creare is developing advanced evaporators, condensors, and single-phase heat exchangers for operation in microgravity. The objective is to achieve a several-fold increase in the heat flux capability of these components, while operating at the same temperature difference as specified for the present interface heat exchangers. Two prototype interface heat exchangers are presently being developed: one to interface the main thermal bus to a payload two-phase ammonia bus, and the other, to interface with the crew module single-phase water loop. The results achieved to date in the development of these heat exchangers are reviewed.

Valenzuela, Javier A.↗

Advanced absorber heat integration via heat exchange packings

A rate-based model of an absorption column was developed and used to analyze several intercooling strategies utilizing “heat exchange packings.” These packings are capable of removing heat from the column and transferring it to a cooling fluid within the packing. For absorption of CO 2 into aqueous monoethanolamine under industrial conditions, intercooling via heat exchange packings placed along 10–20% of the column could reduce the column height by ~15%. The height of these columns was close to the minimum theoretical value, calculated by numerically optimizing the temperature profile. Effective intercooling could also be achieved by using the cool, rich solvent as the cooling fluid. This reduces the cooling load and facilitates recovery of waste heat. Heat exchange packings could also be used to redistribute heat within the column, reducing the column height with no net cooling load. However, this approach requires larger heat transfer coefficients than have been experimentally observed.

20 FOSSIL-FUELED POWER PLANTS↗