Geothermal Deep Direct Use for Turbine Inlet Cooling in East Texas

The National Renewable Energy Laboratory (NREL), the Southern Methodist University Geothermal Laboratory (SMU), Eastman Chemical (Longview, TX), and TAS (Houston, TX) evaluated the feasibility of using geothermal heat to improve the performance of a natural-gas power plant in East Texas. The area of interest is the Eastman Chemical plant in Longview, Texas, which is on the northwestern margin of a geologic region known as the Sabine Uplift. The feasibility study focused on determining the potential for accessing a subsurface hot-water geothermal resource within a 10-km radius of the site to provide thermal energy for absorption chillers. Wells within a 20-km radius are included for broader geological comparison to determine the heat flow, temperature-at-depth, field porosity and permeability. The lithologies of most interest are the Lower Cretaceous Trinity Group and Upper Jurassic Cotton Valley Group. The deeper Cotton Valley formations are hotter (averaging 117 to 130°C), yet permeability and porosity are low. The shallower Trinity Group contains more variability in permeability and porosity and lower temperatures averaging about 98 to 117°C. The shallower formations are considered despite the lower temperature because of increased ability to produce larger volumes of water and extract enough heat before reinjection. The complete SMU analysis is available in the National Geothermal Data System (NGDS). Tapping such deep geothermal sources for direct heating (as opposed to power generation) is known as geothermal deep direct use (DDU). Geothermal DDU has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for what are typically small-scale, variable-demand projects. This project examines the feasibility of geothermal energy integration in a natural-gas combined cycle power station in East Texas. The DDU resource is tapped to drive absorption chillers (24/7) for production of chilled water at 5-10°C (41-50°F). This chilled water is stored until needed, which allows for continuous operation with a relatively small-capacity geothermal/absorption chiller system. When conditions are favorable, the chilled water is dispatched to cool the air entering the compressor stage of a gas combustion turbine. This process, known as turbine inlet cooling (TIC), boosts power production during periods of high temperature and high-power demand. Such systems can enhance grid reliability and reduce the cost for peak-demand power. A simulation model of the power plant was developed in IPSEpro software and validated against operational data from the plant. This model allowed the team to estimate the additional power that could be produced by applying TIC under different operating and ambient conditions. Absorption chiller performance was estimated from vendor sources to determine the production rate of chilled water from the geothermal resource. Geothermal drilling and development costs were estimated using NREL's GEOPHIRES 2.0. The expected lower drilling costs in this region led to an estimated cost of geothermal heat of about $4/MMBtu (1.4 cents/kWh t ). The estimated cost for the absorption chillers and TIC hardware were obtained from literature sources and project partners. Hourly data were obtained for weather, natural gas and electricity prices, and plant operating state for 2017, which served as a representative year. NREL estimated the capital cost, operating cost, and additional electricity production and revenue for different combinations of geothermal capacity, chiller capacity, and water storage-tank size. The analysis drove toward smaller geothermal and chiller systems to reduce equipment cost. A relatively low-cost water storage tank accumulated the near-continuous chilled water output for later use when TIC was most valued.

15 GEOTHERMAL ENERGY↗

Modeled Retrofit Package Performance for Schools

This report details modeled energy performance and savings from retrofit packages in prototypical school buildings in climate zones throughout the U.S. The information herein serves as a reference for elementary and secondary schools interested in implementing retrofit packages in their facilities for energy savings as well as health and safety benefits. School models developed for simulating package performance differentiated between rural and urban environments. Simulations were run for 10 distinct climate zones covering a range of climate conditions throughout the U.S. Results include savings estimates for electricity, natural gas, CO 2 emissions, and annual utility costs for nine different retrofit packages that combine energy conservation measures, including HVAC controls and equipment upgrades, lighting efficiency upgrades, and electrification technologies such as heat pumps for space conditioning and domestic hot water. Nine additional retrofit packages were also developed for elementary schools and modeled in two climate zones. Appendix B describes the additional retrofit packages and presents savings estimates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Illinois Compressed Air Energy Storage

Compressed Air Storage Energy (CAES) is one of the few mid- technology readiness level (TRL) energy storage technologies that can address the long-duration infrastructure needed for dealing with variable electric output from renewable energy sources and be reliable backup source for replacing natural gas during supply interruptions. In CAES the goal is to capture and store compressed air in subsurface sedimentary strata when off-peak power is available, or there is a need for grid balancing. The stored high-pressure air is returned to the surface and used to power turbines during reductions in either renewable energy or supply issues with fossil fuels. The Illinois CAES project evaluates the feasibility of capturing surplus electrical energy from renewable sources and off-peak energy at a fossil fuel power plant at the University of Illinois Urbana - Champaign (UIUC) campus. The UIUC Abbott Power Plant uses natural gas and coal to generate electricity (capacity: 35 MWe by coal and 49 MWe by NG). UIUC receives additional electricity from on campus solar farm, and off-campus wind farm. Also, UIUC offsets electricity usage by integrating geothermal energy systems into building heating Also, UIUC offsets steam, hot and chilled water usage by integrating geothermal energy systems into building heating and cooling systems. Furthermore, the two UIUC solar farms (Solar Farm 1 is 21 acres and Solar Farm 2 is 54 acres) to generate 4.68 megawatts (MW) and 12.1 MW, respectively. Campus receives 8.6% of the wind-generated electricity from the Rail Splitter Wind Farm. The project objectives were to design an integrated system to 1) capture surplus electrical energy from renewable sources and the Abbott Power Plant using a CAES system, 2) store both the compressed air and the thermal heat generated by compression in the subsurface as part of an adiabatic system, 3) simulate the movement of the air and heat in the subsurface, 4) recover the compressed air and stored thermal heat to rotate turbine generators during sustained interruption due to weather events or fossil fuel disruptions.

03 NATURAL GAS↗

Cosmic Ray Mediated Thermal Fronts in the Warm-Hot Circumgalactic Medium

We investigate the 1D plane-parallel front connecting the warm ($10^4$ K) and hot ($10^6$ K) phases of the circumgalactic medium (CGM), focusing on the influence of cosmic rays (CRs) in shaping these transition layers. We find that cosmic rays dictate the thermal balance while other fluxes (thermal conduction, radiative cooling, and gas flow) adjust to compensate. We compute column density ratios for selected transition temperature ions and compare them with observational data. While most of our models fail to reproduce the observations, a few are successful, although we make no claims for their uniqueness. Some of the discrepancies may indicate challenges in capturing the profiles in cooler, photoionized regions, as has been suggested for by previous efforts to model thermal transition layers.

79 ASTRONOMY AND ASTROPHYSICS↗

Searching For Transiting Planets Around Halo Stars. I. Sample Selection and Validation

By measuring the elemental abundances of a star, we can gain insight into the composition of its initial gas cloud—the formation site of the star and its planets. Planet formation requires metals, the availability of which is determined by the elemental abundance. In the case where metals are extremely deficient, planet formation can be stifled. To investigate such a scenario requires a large sample of metal-poor stars and a search for planets therein. This paper focuses on the selection and validation of a halo star sample. We select ~17,000 metal-poor halo stars based on their Galactic kinematics, and confirm their low metallicities ([Fe/H] < -0.5), using spectroscopy from the literature. Furthermore, we perform high-resolution spectroscopic observations using LBT/PEPSI and conduct detailed metallicity ([Fe/H]) analyses on a sample of 13 previously-known halo stars that also have hot kinematics. We can use the halo star sample presented here to measure the frequency of planets and to test planet formation in extremely metal-poor environments. The result of the planet search and its implications will be presented and discussed in a companion paper by Boley et al.

47 OTHER INSTRUMENTATION↗

Directly imaging the cooling flow in the Phoenix cluster

In the centres of many galaxy clusters, the hot (approximately 10 7 kelvin) intracluster medium can become dense enough that it should cool on short timescales. However, the low measured star formation rates in massive central galaxies and the absence of soft X-ray lines from the cooling gas suggest that most of this gas never cools. This is known as the cooling flow problem. The latest observations suggest that black hole jets are maintaining the vast majority of gas at high temperatures. A cooling flow has yet to be fully mapped through all the gas phases in any galaxy cluster. Here we present observations of the Phoenix cluster using the James Webb Space Telescope to map the [Ne vi] λ 7.652-μm emission line, enabling us to probe the gas at 10 5.5 kelvin on large scales. These data show extended [Ne vi] emission that is cospatial with the cooling peak in the intracluster medium, the coolest gas phases and the sites of active star formation. Taken together, these imply a recent episode of rapid cooling, causing a short-lived spike in the cooling rate, which we estimate to be 5,000–23,000 solar masses per year. As a result, these data provide a large-scale map of gas at temperatures between 10 5 kelvin and 10 6 kelvin in a cluster core, and highlight the critical role that black hole feedback has in not only regulating cooling but also promoting it.

79 ASTRONOMY AND ASTROPHYSICS↗

Field Study of 120-volt Heat Pump Water Heaters in the Big Easy

To meet long-term goals for reducing carbon emissions and lessen the impacts of climate change, the U.S. plans to decarbonize its building stock, which includes the replacement of fossil fuel-burning end uses with energy efficient electric alternatives. As part of this strategy, the replacement of fossil fuel water heaters with heat pump water heaters (HPWH) has the potential to avoid substantial carbon emissions. An estimated 10-15 million single-family homes with fossil fuel water heaters do not have the electrical panel capacity to install a 240-volt, 30-amp HPWH. For these homes, a technology recently introduced to the market, the 120-volt plug-in HPWH, can provide energy efficient electrification of water heating without an expensive panel and wiring retrofit. This paper presents the results of an ongoing 120-volt HPWH field study conducted in 17 homes in New Orleans, LA. Key installation scenarios are profiled for retrofitting from gas-fired water heaters to 120-volt HPWHs, accounting for space, air volume, air temperature, condensate drainage, and electrical. Each HPWH had its surrounding air temperature, relative humidity, inlet and outlet water temperature, flow, and energy consumption monitored. Using these data, hot water delivery and energy efficiency performance were analyzed based on home characteristics. Hot water run outs were investigated to understand how hot water usage, inlet water temperature, and surrounding air temperature impact the HPWH’s ability to meet load. From these results, best practices for 120-volt HPWH siting, sizing, and installation were developed. In addition, results are explored further to add insight for electrification policies and product development.

heat pump water heater, 120-volt, Residential buil↗

A multiscale packed-bed reactor model for sustainable ethylene production via chemical looping oxidative coupling of methane

The rising global warming concerns and shale gas discovery have prompted research in the direction of greenhouse gas (GHG), such as methane, reduction and conversion. Oxidative coupling of methane (OCM) offers a pathway to low carbon-intense valorization of methane while producing ethylene, a chemical regarded as central to the petrochemical industry. Even after decades of OCM discovery, researchers keep understanding the process and underlying chemical reactions in a pursuit to achieve industrial viability for OCM. Here, in general, OCM suffers from low C 2 selectivity, yield and reactor temperature runaways due to highly exothermic nature of its reactions. Computational Fluid Dynamics (CFD) tools help analyze spatial gradients within the reactor to deeply understand the diffusion of species, mass and heat transfer phenomena. Furthermore, challenges associated with scaling up such as hot spot formation and parametric sensitivity can be addressed without having to expend on costly experiments. The current paper presents a multiscale packed-bed reactor CFD model coupled with a chemical kinetic model for the chemical looping OCM. The CFD model includes two scales i.e., macroscale for catalyst bed and microscale for individual pellets. Moreover, a chemical kinetic model based on 10 gas-phase reactions is integrated with the CFD model. An additional surface reaction for the formation of gas-phase oxygen from catalyst surface is added to account for the absence of feed oxygen. The model is calibrated against experimental results. The calibrated model captures trends in CH 4 conversion, C 2 selectivity and C 2 yield within a ± 4.35 % range across a temperature range of 700-900 °C. Moreover, model fidelity is evaluated by varying key computational parameters such as mesh resolution and time step size. The model is also verified by varying the inlet methane concentration and the gas hourly space velocity (GHSV) and comparing the results with literature. A sensitivity analysis and scale-up of the current model is undergoing.

Chemical looping↗

Understanding asymmetries using integrated simulations of capsule implosions in low gas-fill hohlraums at the National Ignition Facility

Current capsule implosions at the National Ignition Facility (NIF) using high-density-carbon ablators and laser energies close to 2 MJ have shown neutron yields in excess of 50 kJ. Improving on this performance requires understanding of the different degradation mechanisms. For many NIF implosions, nuclear diagnostic signatures have inferred residual hot-spot velocities that correlate with fuel areal density variations consistent with a low-order mode-1 asymmetry. A current working hypothesis attributes these asymmetries to a combination of beam to beam variations in the laser delivery and possibly coupling to target features, such as the diagnostic holes needed for x-ray imaging. Recently, a new source has been identified, thickness variation in the ablator shell. To gain better understanding and eventually mitigate the causes of <ρR> asymmetries, 3D integrated simulations using the actual delivered laser powers are needed. To capture the effect of the diagnostic holes (DHs) using direct numerical simulation would require significantly large computational resources. Instead, our 3D simulations make use of a subgrid model developed using highly-resolved 2D simulations that include several details of the DH engineering complexity. Simulations of NIF shots using hohlraums without DHs, to isolate the effect of beam-to-beam variations, reproduce fairly well the observed nuclear diagnostic signatures. Similarly, reasonable agreement between data and simulations is also obtained in the presence of diagnostic holes. To account for the remaining discrepancies a sensitivity study of ablator thickness variation showed that 1% thickness asymmetries are comparable in effect to 1% peak drive mode-1 asymmetries. Furthermore, this study identified sensitivity to variations in the imbedded doped layer (needed to shield the DT ice from the high energy x-rays generated in the hohlraum) thickness even when the inner and outer surface of the ablator are perfectly spherical.

radiation hydrodynamics↗

Manufacture aluminum alloy tube from powder with a single-step extrusion via ShAPE

Mechanical performance of aluminum in terms of strength, wear and corrosion resistance, especially high-temperature strength has been shown to improve with the addition of transition metal (TM) elements of Fe, Cr, and Ti. However, these feedstock materials occur as powders. As such, the traditional fabrication process is complex and expensive because it requires multiple procedures and consumes considerable energy. This study developed Shear Assisted Processing and Extrusion (ShAPE) as a single-step process that manufactures tubes directly from Al-TM powders obtained via gas atomization. Meter-long Al-TM alloy tubes are extruded from powders with different processing conditions. The ShAPE tubes have very low porosity and the average density is 2.94 kg/cm 3 , which is equal to or higher than parts fabricated by hot extrusion and sintering. The powder-to-tube fabrication process was revealed and discussed by examining the microstructural evolution. The Vickers hardness of ShAPE tubes ranges from 110 to 140 HV through wall thickness and at different extrusion speeds. The variation in hardness was correlated with the extent of refinement of intermetallics and attributed to the shear deformation per unit extrusion length. Energy cost analysis shows that ShAPE save ~60% energy compared to the conventional sintering and extrusion processes. Results indicate ShAPE is a low-cost, high-efficiency manufacturing process for producing tubes from metallic powders.

36 MATERIALS SCIENCE↗

Near-field models and simulations of pellet ablation in tokamaks

Here, detailed numerical studies of the ablation of a single neon pellet in the plasma disruption mitigation parameter space have been performed. Simulations were carried out using FronTier, a hydrodynamic/low magnetic Reynolds number MHD code with explicit tracking of material interfaces. FronTier's physics models resolve the pellet surface ablation and the formation of a dense, cold cloud of ablated material, the deposition of energy from hot plasma electrons, the expansion of the ablation cloud along magnetic field lines, and the radiation losses. A local thermodynamic equilibrium model based on Saha equations has been used to resolve atomic processes in the cloud and Redlich–Kwong corrections to the ideal gas equation of state for cold and dense gases, which have been used near the pellet surface. The FronTier pellet code is a next generation of the code described. It has been validated against the semi-analytic improved neutral gas shielding model in the 1D spherically symmetric approximation. Main results include quantification of the influence of atomic processes and Redlich–Kwong corrections on the pellet ablation in spherically symmetric approximation and verification of analytic scaling laws in a broad range of pellet and plasma parameters. Using axially symmetric MHD simulations, the properties of ablation channels and the reduction of pellet ablation rates in magnetic fields of increasing strength have been studied. While the main emphasis has been given to neon pellets for the plasma disruption mitigation, selected results on deuterium fueling pellets have also been presented.

97 MATHEMATICS AND COMPUTING↗

The generation of a multiphase medium in ‘Splash’ bridge systems: towards an understanding of star formation suppression in turbulent galaxy systems

ABSTRACT Cloud–cloud collisions in splash bridges produced in gas-rich disc galaxy collisions offer a brief but interesting environment to study the effects of shocks and turbulence on star formation rates in the diffuse intergalactic medium, far from the significant feedback effects of massive star formation and active galactic nucleus. Expanding on our earlier work, we describe simulated collisions between counter-rotating disc galaxies of relatively similar mass, focusing on the thermal and kinematic effects of relative inclination and disc offset at the closest approach. This includes essential heating and cooling signatures, which go some way towards explaining the luminous power in H$_2$ and [C ii] emission in the Taffy bridge, as well as providing a partial explanation of the turbulent nature of the recently observed compact CO-emitting clouds observed in Taffy by the Atacama Large Millimeter Array (ALMA). The models show counter-rotating disc collisions result in swirling, shearing kinematics for the gas in much of the post-collision bridge. Gas with little specific angular momentum due to collisions between counter-rotating streams accumulates near the centre of mass. The disturbances and mixing in the bridge drive continuing cloud collisions, differential shock heating, and cooling throughout. A wide range of relative gas phases and line-of-sight velocity distributions are found in the bridges, depending sensitively on initial disc orientations, and the resulting variety of cloud collision histories. Most cloud collisions can occur promptly or persist for quite a long duration. Cold and hot phases can largely overlap throughout the bridge or can be separated into different parts of the bridge.

79 ASTRONOMY AND ASTROPHYSICS↗

Multi-jet gas cooling of in-beam foils or specimens: CFD predictions of the convective heat-transfer coefficient

An experiment was designed to investigate the possible enhancement of the convective heat-transfer coefficient by utilizing multiple, parallel jets in the cooling of a small heated surface, such as typically induced by an accelerated ion beam on a thin foil or specimen. The hot spot was provided using a small electrically heated plate. It was found that heat-transfer calculations by means of simple empirical methods based on dimensional analysis are not useful in this case and that advanced computational fluid dynamics (CFD) modelling is essential to interpret the results. It is shown that enhanced convective cooling can indeed be obtained with a multi-jet configuration as compared to a single-jet configuration but only under very selective conditions. An improperly designed multi-jet configuration can also provide significantly reduced cooling relative to the single-jet case and the estimation of the behavior of any particular jet geometry is eminently non-intuitive. CFD provides acceptable quantitative results and seem to be the only tool available to gain an understanding of these complex flows where simple models and “rules of thumb” cannot be relied upon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Multi-Tube Mixer Combustion for 65% Efficiency (Final Report)

This project targeted advanced low NOx combustion for advanced gas turbines capable of 65%, or greater, efficiency in combined cycle application. This technology advancement has further potential to benefit gas turbines used in coal based IGCC applications with pre-combustion carbon capture and hydrogen as the resulting fuel. The program developed and synthesized the most advanced combustion system capable of achieving low NOX emissions up to turbine inlet temperatures of 3100F while also supporting the load-following needs of a modern grid. The combustion system contributes to the overall gas turbine efficiency goal by setting the maximum cycle temperature achievable for a given NOX level and by minimizing the through-combustor air flow pressure drop. Focus areas for this project targeted maximizing the turbine inlet temperature entitlement, as constrained by emissions considerations. The design also minimized parasitic air flow pressure drop by using advanced cooling techniques and performance materials selections and by minimizing hot surface area. These two technology objectives (maximum, emissions-compliant cycle temperature and minimum air flow pressure drop) were integrated into a prototype design. The primarily analytical project sought to identify the most promising technologies to meet these objectives. Additional critical “jugular” data were obtained from multi-tube mixer tests to realize the potential of leveraging “micro flames” for minimizing overall hot surface area. This data was used, in conjunction with an understanding of advanced material and cooling design technologies, to analytically develop multiple design concepts. Phase I focused on in-depth engineering analysis and design, with minimal supporting laboratory testing to enable a selection of the top three combustion architectures for achieving these overall objectives. Phase II of the program developed the selected design through a combination of sub-scale testing and analytical efforts. Early tests included a cold-flow cascade to establish aerodynamic performance characteristics and a sub-scale fired test at GE Global Research in Niskayuna, NY, to establish cooling and heat transfer characteristics in conjunction with combustion performance. The data from these tests validated the analytical models to ultimately design a full-scale, test article to evaluate at prototypical pressure and temperature conditions at GE Gas Power’s Gas Turbine Technology Laboratory in Greenville, SC. GE Gas Power also developed, tested, and recommended a suitable seal design to be applied to the unique features of the combustor. To assess the technology challenges from prospective future production of the combustor from a ceramic matrix composite material, screening tests of Environmental Barrier Coatings were completed.

20 FOSSIL-FUELED POWER PLANTS↗

Tritiated Sulfur Hexafluoride Disposition Strategies

Tritium (T 2 ) is a radioactive isotope of hydrogen that is produced in nuclear fission reactions and is often used in nuclear fusion reactions and accelerator-based applications for medical isotope production. As a hydrogen isotope, tritium can readily bind to hydroxyl radicals (OH), forming tritiated water (HTO or T 2 0), and to carbon atoms. Tritium decays to helium-3 ( 3 He) via beta-decay with max decay energy of 18.6 keV. While it is not an external radiation hazard, it can be an internal radiation hazard if tritium is inhaled, ingested, or absorbed through the skin. In applications where tritium is handled, tritium confinement is performed using different barriers to minimize releases to the environment. For gaseous (elemental), liquid (oxide), and metal (hydride) tritium, process piping and components provide the primary confinement function. Secondary tritium confinement is typically provided by inert (i.e. non-flammable gases such as nitrogen, argon, or helium) gloveboxes which are connected to a tritium stripper system. Primary tritium confinement barriers typically produce low volumes of high tritium concentrations of tritiated methane from carbon in steels or organic materials along with tritiated water/tritium oxide (e.g. HTO) and tritiated ammonia from reactions with oxygen and nitrogen. Tritium escaping primary confinement into secondary confinement atmospheres (e.g. gloveboxes) produce higher volumes of lower activity contamination than found in process piping. Tritium contamination also occurs by leaks or tritium permeation/diffusion through confinement materials. Tritium from inside primary confinement barriers will diffuse or leak out of the primary confinement barrier and usually into the air, if the system is inside an air hood or ventilated hot cell, or into the secondary confinement (e.g. glovebox) atmosphere which is either exhausted or stripped based on the function of the secondary confinement (glovebox) system. Accelerator based processes for medical isotope production represent an atypical tritium contamination challenge. In medical isotope production, deuterium supply gas is ionized and accelerated to a tritium gas target to produce neutrons that are then used to produce the medical isotopes through additional nuclear fission reactions. To create large voltage differentials for accelerator operations, an electrical insulation medium is needed to prevent or rapidly quench electric discharges. A common electrical insulation medium utilized in accelerator applications is sulfur hexafluoride (SF 6 ) gas. SF 6 has a high dielectric strength and allows for the construction of smaller accelerator systems compared to other electrical insulation mediums such as air or dry nitrogen. Due to tritium permeation/diffusion through accelerator process and confinement materials, there is the possibility that tritium can contaminate the electrical insulation medium of the accelerator. Tritium contaminated SF 6 creates a material without any obvious processes for managing the contamination, reuse, or disposal of the used SF 6 . This document will discuss possible management strategies for tritium contaminated SF 6 for accelerator-based processes for Molybdenum-99 (Mo-99) production.

07 ISOTOPE AND RADIATION SOURCES↗

Symmetric fielding of the largest diamond capsule implosions on the NIF

We present results for the largest diamond capsule implosions driven symmetrically on the National Ignition Facility (NIF) (inner radius of ~1050 μm) without the use of cross beam transfer in cylindrical Hohlraums. We show that the methodology of designing Hohlraum parameters in a semi-empirical way using an extensive database resulted in a round implosion. In addition, we show that the radiation flux symmetry is well controlled during the foot of the pulse and that swings in P2 symmetry between the inflight dense shell and hot spot are within ±4 μm and that swings around peak compression are also within the symmetry specification of ±4 μm. We observed a stronger dependence of symmetry on the capsule scale than previously observed and also observed enhanced inner beam propagation for experiments using a gas fill density of 0.3 mg/cm 3 and 1000 μm inner radius capsules. We have observed sufficient symmetry and mass remaining at near full NIF power and energy, up to 480 TW and 1.9 MJ, with little laser–plasma interactions (low laser backscattered light) and predict that this design could support extended NIF energy of up to 2.1 MJ.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TOI-2374 b and TOI-3071 b: two metal-rich sub-Saturns well within the Neptunian desert

ABSTRACT We report the discovery of two transiting planets detected by the Transiting Exoplanet Survey Satellite (TESS), TOI-2374 b and TOI-3071 b, orbiting a K5V and an F8V star, respectively, with periods of 4.31 and 1.27 d, respectively. We confirm and characterize these two planets with a variety of ground-based and follow-up observations, including photometry, precise radial velocity monitoring and high-resolution imaging. The planetary and orbital parameters were derived from a joint analysis of the radial velocities and photometric data. We found that the two planets have masses of (57 ± 4) M⊕ or (0.18 ± 0.01) MJ, and (68 ± 4) M⊕ or (0.21 ± 0.01) MJ, respectively, and they have radii of (6.8 ± 0.3) R⊕ or (0.61 ± 0.03) RJ and (7.2 ± 0.5) R⊕ or (0.64 ± 0.05) RJ, respectively. These parameters correspond to sub-Saturns within the Neptunian desert, both planets being hot and highly irradiated, with Teq ≈ 745 K and Teq ≈ 1812 K, respectively, assuming a Bond albedo of 0.5. TOI-3071 b has the hottest equilibrium temperature of all known planets with masses between 10 and 300 M⊕ and radii less than 1.5 RJ. By applying gas giant evolution models we found that both planets, especially TOI-3071 b, are very metal-rich. This challenges standard formation models which generally predict lower heavy-element masses for planets with similar characteristics. We studied the evolution of the planets’ atmospheres under photoevaporation and concluded that both are stable against evaporation due to their large masses and likely high metallicities in their gaseous envelopes.

Hacker, Alejandro (ORCID:0009000994520181)↗

Design of a Meso-Scale Test of a Fracture Thermal Energy Storage (FTES) System

This paper will present the characterization, scaling, and design of an intermediate-scale field test of a fracture thermal energy storage system (FTES). Seasonal storage of thermal energy has the potential to both significantly reduce the total energy requirements for heating and cooling of buildings, but also allow for the flexibility to store thermal energy from intermittent sources. With approximately half of global energy consumption currently being used for heating and cooling, this represents an important path to reducing greenhouse gas (GHG) emissions. The concept of FTES is to drill two or more wells into a low permeability formation, generally at a depth of less than a few hundred meters, and then generate hydraulic fractures to create flow paths for water to circulate between the wells. Hot or cold thermal energy can then be stored in the surrounding rock mass by circulating hot or cold water through the fractures, which will heat or cool the rock mass. To recover the stored energy, ambient temperature water can be then circulated through the fractures, which will then be heated or cooled by the rock mass. Fractures inherently have a very large ratio of surface area to volume. This allows for very high heat fluxes to and from the rock mass to be achieved despite the relatively low thermal conductivity of most geologic formations. Because large fractures can be made with low-cost equipment and with only inexpensive and environmentally safe materials such as water and sand, the cost to construct even large FTES systems is expected to be quite low. This paper will present what the performance requirements, size, and operating conditions of a full-scale system to operate a commercial building. The paper will describe how these full-scale system characteristics will be used as a design basis for an intermediate-scale FTES test to be conducted at the Sanford Underground Research Facility (SURF) in Lead, SD.