Search NASA⌕ Search

SEARCH · Search NASA

Results for “humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Sensitivity of thermodynamic profiles retrieved from ground-based microwave and infrared observations to additional input data from active remote sensing instruments and numerical weather prediction models

Accurate and continuous estimates of the thermodynamic structure of the lower atmosphere are highly beneficial to meteorological process understanding and its applications, such as weather forecasting. In this study, the Tropospheric Remotely Observed Profiling via Optimal Estimation (TROPoe) physical retrieval is used to retrieve temperature and humidity profiles from various combinations of input data collected by passive and active remote sensing instruments, in situ surface platforms, and numerical weather prediction models. Among the employed instruments are microwave radiometers (MWRs), infrared spectrometers (IRSs), radio acoustic sounding systems (RASSs), ceilometers, and surface sensors. TROPoe uses brightness temperatures and/or radiances from MWRs and IRSs, as well as other observational inputs (virtual temperature from the RASS, cloud-base height from the ceilometer, pressure, temperature, and humidity from the surface sensors) in a physical iterative retrieval approach. This starts from a climatologically reasonable profile of temperature and water vapor, with the radiative transfer model iteratively adjusting the assumed temperature and humidity profiles until the derived brightness temperatures and radiances match those observed by the MWR and/or IRS instruments within a specified uncertainty, as well as within the uncertainties of the other observations, if used as input. In this study, due to the uniqueness of the dataset that includes all the above-mentioned sensors, TROPoe is tested with different observational input combinations, some of which also include information higher than 4 km above ground level (a.g.l.) from the operational Rapid Refresh numerical weather prediction model. These temperature and humidity retrievals are assessed against independent collocated radiosonde profiles under non-cloudy conditions to assess the sensitivity of the TROPoe retrievals to different input combinations.

54 ENVIRONMENTAL SCIENCES↗

Improving thermodynamic nudging in the E3SM Atmosphere Model version 2 (EAMv2): strategy and hindcast skills on weather systems

Nudging techniques are commonly employed to constrain atmospheric simulations toward observed states, facilitating model evaluation and sensitivity studies. However, if applied improperly – particularly to thermodynamic variables such as temperature and humidity – nudging can distort physical processes and introduce spurious biases, undermining the credibility of the simulations. This study presents an improved nudging implementation that applies vertically modulated tendencies to reduce adverse impacts on model physics. The framework is tested in version 2 of the Energy Exascale Earth System Model (EAMv2) using a suite of hindcast simulations nudged toward ERA5 reanalysis. We systematically evaluate the individual and combined effects of nudging wind, temperature, and humidity fields on the model's ability to represent large-scale atmospheric states and high-impact weather systems. Results show that the revised strategy – particularly when nudging temperature and humidity at selected levels – enhances hindcast skill by improving agreement with ERA5 without degrading the hydrological cycle or precipitation processes. Additional improvements in surface temperature, outgoing longwave radiation, and precipitation biases are achieved through targeted nudging of land-surface variables. The proposed approach strengthens the representation of large-scale conditions relevant to tropical cyclones, atmospheric rivers, and extratropical cyclones in the low-resolution EAMv2. These findings demonstrate that carefully designed thermodynamic nudging, especially of temperature and humidity, improves the realism of constrained simulations and broadens the utility of nudged EAMv2 for atmospheric modeling, machine learning, and high-impact weather research.

Atmospheric river↗

EPCAPE-PT-LANL Measurements: Humidified Cavity Attenuated Phase Shift Spectroscopy

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Humidified Cavity Attenuated Phase Shift Particulate Matter Single Scattering Albedo (H-CAPS-PMSSA, Aerodyne Inc) Data Notes: The scattering truncation correction was not applied to Bsca. The Bext needs no correction. Files: data_10sec_CAPS.csv, data_10min_CAPS.csv Header: - Bext_wet_CAPS_450nm[1/Mm]: Wet aerosol extinction coefficient measured at 450 nm by the CAPS, in inverse megameters (Mm⁻¹). - Bsca_wet_CAPS_450nm[1/Mm]: Wet aerosol scattering coefficient measured at 450 nm by the CAPS, in inverse megameters (Mm⁻¹). - Temp_wet_CAPS[K]: Temperature inside the wet CAPS measurement chamber, in Kelvin. - Bext_dry_CAPS_450nm[1/Mm]: Dry aerosol extinction coefficient measured at 450 nm by the CAPS, in inverse megameters (Mm⁻¹). - Bsca_dry_CAPS_450nm[1/Mm]: Dry aerosol scattering coefficient measured at 450 nm by the CAPS, in inverse megameters (Mm⁻¹). - Temp_dry_CAPS[K]: Temperature inside the dry CAPS measurement chamber, in Kelvin. - Wet_RH_preCAPS[%]: Relative humidity before entering the wet CAPS, in percent. - Wet_RH_postCAPS[%]: Relative humidity after exiting the wet CAPS, in percent. - Humidifier_RH_CAPS[%]: Relative humidity inside the humidifier used with the CAPS, in percent. - dualCAPS_inlet_RH[%]: Relative humidity at the inlet of the dual (wet/dry) CAPS setup, in percent. - Wet_Temp_preCAPS[C]: Temperature before entering the wet CAPS, in degrees Celsius. - Wet_Temp_postCAPS[C]: Temperature after exiting the wet CAPS, in degrees Celsius. - Humidifier_Temp[C]: Temperature inside the humidifier used with the CAPS, in degrees Celsius. - dualCAPS_inlet_Temp[C]: Temperature at the inlet of the dual (wet/dry) CAPS setup, in degrees Celsius. - Zero_dry_CAPS: 1 is a calibration check for the dry CAPS to ensure zero reading under filter air conditions. - Zero_wet_CAPS: 1 is a calibration check for the wet CAPS to ensure zero reading under filter air conditions. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement.

54 ENVIRONMENTAL SCIENCES↗

Adaptive Water-Resistive Barrier for Building Envelopes

Excessive moisture transport into building enclosures can lead to elevated moisture levels in wall cavities and associated damage. Such conditions can also produce increased energy consumption. Currently, architects and builders are limited to using static membranes as water-resistive barriers that exhibit a single vapor permeance irrespective of environmental conditions. Membranes with a high permeance may allow moisture ingression under hot and humid ambient conditions, while membranes with a low permeance may not allow wall cavities to dry out when moisture accumulates within them.An electrostatically actuated, dual permeance membrane previously demonstrated for protective apparel is under development for use as a water-resistive barrier for building envelopes. When outdoor temperature and relative humidity are high as detected by sensors, the membrane exhibits low permeance (~0.5 perms) to inhibit water vapor ingression into the building enclosure; but when humidity in the wall cavity is high, the membrane exhibits high permeance (~50 perms) to facilitate water vapor egression to the outside. The membrane changes state by electrostatic actuation using a very low current electrical power supply.In order to quantify the benefits of a dual permeance water-resistive barrier, WUFI® hygrothermal modeling simulations were completed comparing the adaptive membrane to conventional fixed permeance membranes relative to inhibiting mold growth for various US climates and several wall constructions. The WUFI® code was modified to accommodate switching the permeance of the adaptive membrane between low and high permeance states for several humidity setpoint control strategies. The effect of liquid water leakage into the wall cavity was also considered.This report summarizes the initial steps in development of dual permeance, electrostatically actuated water-resistive barriers focusing on the results of hygrothermal model simulations of these adaptive structures and testing of subscale adaptive structures to demonstrate the capability of the technology to achieve the preferred permeance levels suggested by the modeling.

Trentacosta, Joseph↗

Experimental Investigation of the Effect of Atomizing Electrospray Nozzles on the Cooling and Reduced Humidification of Air

Separating sensible and latent cooling have shown the potential to reduce energy consumption in A/C systems for building HVAC applications. Several technologies exist based on vapor-compression refrigeration, enthalpy wheels, chemical adsorption and absorption materials, and mechanical cooling. However, their thermodynamics limits and high energy consumption hinder their deployment in hot and humid climatic regions. This paper focuses on separating sensible and latent cooling by using a new thermodynamics process and in-kind (i.e., non-vapor compression-based) technology. Highly electrically charged water droplets were sprayed in the airflow. These droplets attracted water vapor molecules to their surfaces and promoted condensation. The phenomenon was the result of simultaneous dielectrophoresis and electro-diffusion interactions. Studies in the literature have shown that using multiple capillary electrodes reduced air moisture by up to 5% when using nanometer-size droplets in the spray. Unfortunately, these studies were limited to low airflow rates, and the objective of this paper was to investigate how to scale up this in-kind approach to airflows typical of buildings. In the present paper, droplets of micrometer size were utilized to control the humidity for a 5-cfm flow rate. While this airflow was still low for building applications, it was 100 times fold the airflows in the literature studies. The air was tested at 20°C and at 50 and 80% relative humidity. A two-fluid atomizing nozzle produced the droplets in the spray, and high DC electric potential, up to 25 kV, was used to charge the fine droplets electrically. The air atomizing nozzle with high voltage potential resembled an evaporative cooler process. However, a measurable reduction of the absolute humidity of up to 2% was observed compared to the case of the nozzle with no high voltage potential. The entire device had one small nozzle selected from off-the-shelf components and had less than a 9 cm2 footprint area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The effect of barrier films and exposure on the aging of vacuum insulation panels with fumed silica cores

Vacuum insulation panels have very low thermal conductivities compared to conventional insulation materials. The reduction of the core pressure significantly lowers gas phase conduction and overall thermal conductivity. As a consequence, increases in gas pressure can significantly increase thermal conductivity of the VIP. In addition, the thermal conductivity of the core is sensitive to moisture content. For vacuum insulation panels with fumed silica cores, work shows that the measured thermal conductivity increases by 0.5 x 10-3 W/mK per mass percent increase in water content [1]. This is significant since the thermal conductivity of vacuum insulation panels with fumed silica cores is in the range of 0.004 W/mK. This work investigates the long-term behavior of vacuum insulation panels comprised of fumed silica cores with polymer (ethylene vinyl alcohol) and metalized (aluminized) barrier films exposed to different exposure conditions: ambient conditions; exterior conditions in a mixed humid climate; and 24oC and 80 percent relative humidity. Results show that the increase in thermal conductivity is more pronounced for vacuum insulation panels made using polymer barrier films compared to the same panel protected by a metalized film. The increase is more pronounced when exposed to high relative humidity, 80 percent. After almost two years exposure, the decrease in thermal conductivity for vacuum insulation panels protected by a metalized barrier films are between 4 and 11 percent depending on exposure condition. The smallest decrease is for ambient conditions where the largest decrease is for exposure to 80 percent relative humidity. Similar behavior was observed for panels protected using polymer films, except the decrease in thermal conductivity was significantly higher, between approximately 20 and 60 percent, in the same order as for panels protected by metalized films. Measurements are ongoing with an attempt to develop a better relationship between these types of tests and vacuum insulation panel service life.

Aldykiewicz Jr, Antonio↗

Effect of Drying on Corrosion Mitigation of Hanford Transfer Lines

Radioactive waste is stored in underground, carbon-steel double-shell tanks at the Department of Energy Hanford site. The waste is transferred between the tanks and other assets using the transfer lines spanning throughout the various tank farms at Hanford. The transfer lines consist of a pipe-in-pipe design, small diameter pipes, and are not piggable. Recent inspection data of the transfer lines have shown areas with corrosion on both interior of the encasements and exterior of the primary pipes, with nearly 50 percent wall loss on the primary pipes and nearly 25% wall loss on the encasement pipes due to pitting corrosion. The visual inspections of the transfer lines have shown presence of corrosion products near the pipeline risers and beyond. It has been hypothesized that the corrosion is predominantly due to the high humidity conditions and in some cases is driven by the presence of residual hydrotest water in the encasement and the associated contact with the safety significant primary pipe. Therefore, drying of the transfer lines could lead to corrosion mitigation. Experimental studies are being conducted to understand the effect of environmental conditions, especially, relative humidity and temperature, on transfer line grade carbon steel corrosion and on mitigating corrosion. The experimental conditions are selected based on the seasonal temperature changes, and relative humidity conditions ranging from 30 to 100 percent. The experimental data will be used as guidance for maintaining a dry environment that will help mitigate the transfer-line corrosion caused by the high humidity conditions.

Shukla, Pavan K.↗

Thermodynamic Model and Initial Experimental Investigation of Air Dehumidification through Electrically Charged Vapor Capturing Electrostatic Droplets

The removal of water vapor from the air to reduce relative humidity is a well known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation with the goal to reduce the energy consumption associated with dehumidification. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. In this thesis, a broad theoretical investigation to study the electrostatically enhanced condensation processes was carried out. These processes consist of the use of highly charged particles, preferably highly charged water droplets to attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. The electrical charge promotes the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation on curved surfaces and, consequently, the equilibrium between evaporation and condensation is shifted towards condensation. This investigation resulted in the development of a thermodynamics model, which was able to predict an effective size range of the charged droplets for optimal dehumidification, under ideal conditions. The range resulted in about 2 to 4 m in diameter, while the electrical charge was kept to the maximum limit predicted by the Rayleigh model. A sensitivity analysis on the variation of the size and the charge of the charged droplets was also performed. In terms of dehumidification rates, when six electrospray heads, i.e. the maximum number of heads tested in the experimental campaign, were considered, the model predicted very limited rates, way lower than the target of this research, i.e. a dehumidification rate in terms of relative humidity of 5 % with an air flow rate of 5 cfm. While ways to increase this rate existed, their implementation proved difficult for this initial investigation. According to the requirements predicted by the model, the use of electrosprays appeared the most suitable solution for the production of small but highly charged droplets. The electrospray features and operational modes were studied in detail and an electrospray assembly was designed to be tested in this initial experimental investigation. For this initial investigation, an experimental system was designed and built to validate the thermodynamics model and with the goal to achieve a dehumidification rate of 5 % in terms of relative humidity with an air flow rate of 5 cfm. The experimental system consisted of a wind tunnel test apparatus, dew point sensors, thermocouples for temperature measurements, pressure sensors and other devices. The experimental system was equipped with a computerized data acquisition and storage system. The system was suitable to evaluate the air water content differential before and after the test section where the electrospray heads were installed. The air water content differential was evaluated in terms of the ∆ω/ω_1 ratio, to eliminate the dependence on the dry bulb temperature along the test apparatus. This work presented initial experimental data for electrostatically enhanced dehumidification processes. Working parameters, such as air and water flow rates, high voltage potentials and polarity, deionized water types with different electrical conductivity, were varied to find the best combination for an improved dehumidification. With the set up used and the conditions considered, it was never possible to achieve a 5 % dehumidification rate with 5 cfm. In general, the dehumidification rate was always limited and lower than 1 % for all the air flow rates considered and mainly within the uncertainty of the dew point sensors. These results confirmed the already limited predictions of the thermodynamics model, for ideal conditions and the interesting and promising results obtained in some experimental investigations available in the open literature were not achievable in this thesis. The more probable reasons were the higher air flow rates considered and the complete absence of the use of cooling power, which was mainly implemented to facilitate the vapor condensation.

Morcelli, Stefano↗

Estimators and Fusers for Fiber Delay Estimation Using Environmental Measurements

The properties of deployed network fiber are affected by environmental factors due to their exposure to the elements. Particularly for quantum networks, the resultant delay variations may have significant impacts due to the extreme sensitivity of synchronization, coincidence counting, and other critical operations. In this paper, the delays of 15 km aerial-inground fiber connections are measured, and effects due to temperature, humidity and wind speed are analyzed over multiple periods spanning four seasons of a year. Machine learning methods are first utilized to reveal surprisingly pronounced effects of humidity on the delay, in addition to the expected temperature and its seasonal variations. Estimator and fusion methods are developed to estimate the delay using temperature, humidity and wind speed measurements, by utilizing smooth Gaussian Process Regression (GPR) and nonsmooth Ensemble of Trees (EOT) methods. Measurements from winter and summer periods are temporally fused using twelve different methods, and eight methods provide estimates for the delay throughout the year with median test errors under 1.28%. The results reveal distinct temperature-humidity trends across the seasons, and the ability of estimator and temporal fusion methods to exploit them for estimating the delay. These results constitute a case study of machine learning analytical results, wherein generalization equations explain the performance of various estimator and fuser methods.

Rao, Nageswara [ORNL] (ORCID:0000000234085941)↗

Parabolic oxidation kinetics of a plutonium alloy at room temperature

Auger electron spectroscopy (AES) was used to characterize the oxide scale formed on an ~0.5 wt. % Ga plutonium metal alloy. Analysis of changes to the characteristic Auger transitions for Pu and O during sputter depth profiles were used in combination with previously measured sputter yields to determine the thickness of the oxide scale and provide insight into its chemistry. From this data, the parabolic kinetics for the Pu-Ga alloy were determined as a function of relative humidity, RH = 14–92%, and oxygen partial pressure, p(O 2 ) = 31–157 Torr, at 25°C. For each relative humidity investigated, the parabolic rate constant was found to be independent of oxygen partial pressure. Furthermore, power-law fits to the relative humidity effect on the rate constant was found to have a power of n = 1.265, indicating the diffusion species which rate-limits the reaction isn’t molecular water, which subsequent dissociates at the oxide-metal interface, or hydroxyl from dissociation at the gas-surface interface.

36 MATERIALS SCIENCE↗

Controlled Demolition and Reconstruction of Imidazolate and Carboxylate Metal–Organic Frameworks by Acid Gas Exposure and Linker Treatment

The metal-linker coordination bond in metal–organic frameworks (MOFs) can be unstable in humid and acid gas environments, leading to loss of crystallinity and porosity. This degradation is not necessarily irreversible; solvent-assisted crystal redemption (“SACRed”) has been shown to recover the physical and chemical properties of ZIF-8 exposed to humid SO 2 . This approach can also be useful in creating mixed-linker materials that might be challenging to produce via de novo synthesis. Here, we expand more generally the concept of controlled degradation of a MOF with acid gas, followed by treatment with a fresh linker solution, to the use of different template MOFs (ZIFs, UiO-66, and UiO-67) and acid gases (SO 2 and NO 2 in dry and humid conditions). Significant losses in porosity and crystallinity along with structural changes (acid gas-linker complexes and linker functionalizations) are observed in the acid gas-exposed MOF templates, and SACRed is shown to reconstruct these partially demolished MOFs with a high degree of structural recovery. Detailed structural and spectroscopic characterizations of the controlled degradation and subsequent recovery are presented and analyzed. Furthermore, these findings indicate the generality of controlled degradation and reconstruction as a means for linker replacement in a wider variety of MOFs and also create the potential for linker substitutions (with non-native linkers) to obtain new hybrid MOFs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

COVID-19: Effects of Environmental Conditions on the Propagation of Respiratory Droplets

As coronavirus disease 2019 (COVID-19) continues to spread, a detailed understanding on the transmission mechanisms is of paramount importance. The disease transmits mainly through respiratory droplets and aerosol. Although models for the evaporation and trajectory of respiratory droplets have been developed, how the environment impacts the transmission of COVID-19 is still unclear. In this study, we investigate the propagation of respiratory droplets and aerosol particles generated by speech under a wide range of temperatures (0–40 °C) and relative humidity (0–92%) conditions. We show that droplets can travel three times farther in low-temperature and high-humidity environment, whereas the number of aerosol particles increases in high-temperature and low-humidity environments. The results also underscore the importance of proper ventilation, as droplets and aerosol spread significantly farther in airstreams. This study contributes to the understanding of the environmental impact on COVID-19 transmission.

60 APPLIED LIFE SCIENCES↗

Moisture-Induced Structural Degradation in Methylammonium Lead Iodide Perovskite Thin Films

Methylammonium lead iodide (CH 3 NH 3 PbI 3 , MAPbI 3 ) belongs to the group of organic–inorganic halide perovskites (OIHPs) that exhibit exceptional electrical and optical behavior suitable for photovoltaic applications. However, improving its structural and chemical stability and robustness remains a challenge for OIHPs to be considered a feasible active material in optoelectronic devices. This is due to the fact that this material is very susceptible to degrade under various intrinsic and extrinsic factors. Therefore, it is crucial to understand the mechanisms through which MAPbI 3 undergoes chemical degradation under operating conditions such as a relatively humid environment. We present the structural characteristics of MAPbI 3 under working conditions that suggest the routes of phase segregation as a result of exposing to highly moist media. We use dark pulse discharge behavior and current–voltage (I–V) variations of MAPbI 3 under different moisture levels to investigate the nature of structural degradation in OIHPs. Here we show that while relatively lower levels of humidity (~60% RH) have a limited impact on the structural stability of MAPbI 3 , exposure to higher levels of moisture (~100% RH) results in the formation of PbI 2 and aqueous CH 3 NH 3 I, which fundamentally change the charge transport characteristics in MAPbI 3 . Our findings explain the ongoing debate on the presence of a threshold for the humidity that triggers irreversible structural transformation and leads to full degradation of MAPbI 3 .

36 MATERIALS SCIENCE↗

Nearby Sites Show Similar Upwind Sources and Differing Semivolatile Concentrations in Coastal Aerosol Particles

The Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) characterized aerosol composition using measurements at two sites within 3 km (Scripps Pier and Mt. Soledad) from 15 February 2023 to 14 February 2024. Comparing the two sites shows the strong influence of upwind sources that results in similar monthly compositions at both sites. The seasonal changes in chemical mass concentrations were largely driven by the upwind source regions, with coastal northwesterly back-trajectories occurring 63−65% of the year and bringing submicrometer mass concentrations that were lower than the EPCAPE average for all trajectories at each site. In contrast, refractory black carbon (rBC) and nonrefractory (NR)-organics and nitrate mass concentrations exceeded EPCAPE average concentrations for back-trajectories from urban areas such as Los Angeles-Long Beach. For hourly measurements, NR-organics and non-sea-salt (NSS)-sulfate mass concentrations at Mt. Soledad were correlated strongly (r = 0.73−0.82) to those measured at Scripps Pier, but NR-nitrate was correlated only moderately (r = 0.63). The explanation for the lower correlation of NR-nitrate is both emissions between the sites and semivolatility, with semivolatility accounting for site-to-site changes in daily averages of +0.01 μg m −3 per percentage site-to-site difference in relative humidity and −0.07 μg m −3 per degree Celsius site-to-site difference in temperature. On average, comparing Scripps Pier to Mt. Soledad, NR-nitrate was higher by 29% because of relative humidity and lower by −26% because of temperature. NR-nitrate and rBC mass concentrations at Scripps Pier for nighttime were 13−15% higher than those for daytime because land breezes brought higher inland concentrations. Concentrations of rBC were 52% higher at Mt. Soledad than those measured at Scripps Pier, accompanied by increases in tracers for brake wear because of traffic on the steep roads within 10 m of that site. The implications are that these nearby sites had comparable monthly concentrations of measured components due to their similar backtrajectories, but hourly and daily concentration differences supported quantification of the meteorological effects from relative humidity and temperature on semivolatile NR-nitrate as well as minor differences from land−sea breezes and local emissions.

Aerosols↗

Changes in Convective Available Potential Energy and Convective Inhibition under Global Warming

Atmospheric convective available potential energy (CAPE) is expected to increase under greenhouse gas–induced global warming, but a recent regional study also suggests enhanced convective inhibition (CIN) over land although its cause is not well understood. In this study, a global climate model is first evaluated by comparing its CAPE and CIN with reanalysis data, and then their future changes and the underlying causes are examined. The climate model reasonably captures the present-day CAPE and CIN patterns seen in the reanalysis, and projects increased CAPE almost everywhere and stronger CIN over most land under global warming. Over land, the cases or times with medium to strong CAPE or CIN would increase while cases with weak CAPE or CIN would decrease, leading to an overall strengthening in their mean values. These projected changes are confirmed by convection-permitting 4-km model simulations over the United States. The CAPE increase results mainly from increased low-level specific humidity, which leads to more latent heating and buoyancy for a lifted parcel above the level of free convection (LFC) and also a higher level of neutral buoyancy. The enhanced CIN over most land results mainly from reduced low-level relative humidity (RH), which leads to a higher lifting condensation level and a higher LFC and thus more negative buoyancy. Over tropical oceans, the near-surface RH increases slightly, leading to slight weakening of CIN. Over the subtropical eastern Pacific and Atlantic Ocean, the impact of reduced low-level atmospheric lapse rates overshadows the effect of increased specific humidity, leading to decreased CAPE.

54 ENVIRONMENTAL SCIENCES↗

Development of a Model Correlating Axial HEPA Filter Performance Between Elevated and Standard Conditions

The ASME AG-1 Code specifies minimum rated airflow based on standard cubic feet per minute (SCFM) for axial high efficiency particulate air (HEPA) filters and actual cubic feet per minute (ACFM) for radial HEPA filters with corresponding maximum pressure drop. A quantitative analysis can be performed to demonstrate the variation in filter efficiency and develop a correlation of performance between axial filters subjected to ACFM and SCFM. This study illustrates the variation in filter efficiency of axial HEPA filters subjected to ACFM and SCFM flow rate conditions at varying atmospheric pressures. It also presents the methods used to calculate correction factors to convert filter efficiency and pressure drop from elevated to standard conditions. The Axial Large Scale Test Stand (ALSTS) in the Institute for Clean Energy Technology (ICET) at Mississippi State University has been utilized to control aerosol concentration, flowrate, atmospheric pressure, relative humidity, and temperature. The filter test matrix consists of axial HEPA filters rated at 1,000 and 1,500 CFM with varying filter pack types. Each filter is subjected to varying pressures of 14.70 psi, 13.55 psi, 12.40 psi, and 11.25 psi, temperatures of 70 deg. F, 110 deg. F, and 150 deg. F, and relative humidities of 50% and 80%, resulting in twenty-four unique testing points. The corresponding SCFM flow rates are computed for each point in order to form a comparison. Evaluation of the effects of designating ACFM or SCFM will be based upon the filter efficiencies of generated Dioctyl Phthalate (DOP) particles at a diameter of 0.3 micrometers. The results show filter efficiency decreasing as atmospheric pressure decreases due to increased filter face velocity. A correlation model is developed to convert filter efficiency and pressure drop at elevated conditions to those of standard pressure, relative humidity, and temperature.

42 ENGINEERING↗

The Argonne SuperGel for CBRN Decontamination - 20160

The Argonne SuperGel was developed between 2003 and 2015 to fill a gap in our nation's capability to quickly decontaminate important structures following a radiological or nuclear release event. Specifically, the decontamination technology was developed to minimize damage to monuments, high valued structures, and critical infrastructure while reducing environmental and health impacts. An important criterion during its development, common reagents were employed that could be easily acquired in order to minimize the timeline for its deployment. Its current formulation uses off-the-shelf super-absorbing hydrogels common to the food and agricultural industry and common salts. Over the years, two formulations of the Argonne SuperGel have been developed to specifically target radioactive cesium contaminations and then, more generically, actinide and fission product contaminations. A biodegradable derivative of phosphoric acid is used in small amounts to promote the removal of insoluble actinide species. The original order of unit operations for the SuperGel technology was 1) applying the wash solution to promote mobility of the contaminants on the surface, 2) applying the hydrogel to absorb the wash solution and contaminants, and 3) removing the hydrogel for disposal. During the course of our studies, we tested a new formulation of the gel technology that eliminated the need for a separate step to apply the wash solution without a compromise in decontamination factors. Greater than 70% and >95% of Cs-137 were removed from concrete and tile coupons, respectively, after two decontaminations, with the best results using wash solutions of 1.0 M KCl and 1.0 M NH{sub 4}Cl formulations. We found no statistical difference between results at 30 deg. C and 40 deg. C or at 70% and 90% relative humidity. We tested the gel under strong UV irradiation to simulate extreme environments. While a tropical noontime UV flux did not adversely affect the gel system decontamination of Cs-137 from concrete or tile coupons, the noontime flux resulted in significant dehydration of the gel after two hours of constant exposure. The rehydration of the gel by the humid air (at 90% humidity and 40 deg. C) was slow and may not be sufficient to offset dehydration by the sun. Americium decontamination from concrete was 70% after optimizing the phosphoric acid derivative and carbonate salt concentration in the wash solution. Since its development, we have had the opportunity to test the SuperGel in the removal of legacy contaminations in hot cell facilities and former glovebox facilities at Argonne. This has provided a unique opportunity to evaluate the SuperGel on a range of contaminants outside the original specifications for its use. We will report on the origin of the gel formulation, some highlighted experimental data including independent testing by the US EPA which has never been reported, and its efficacy for removing legacy alpha contaminations and its potential use for removal of chemical and biological hazardous agents. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗