Search NASA⌕ Search

SEARCH · Search NASA

Results for “hybrid renewable systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Optimal Strategies for Hybrid Battery‐Storage Systems Design

As stationary hybrid energy‐storage systems (HESS) for power systems applications have recently drawn interest due to their enhanced performance and decreasing cost, developing systematic approaches for HESS design while considering controls is gaining traction. Herein, a method is presented to optimally design hybrid battery storage by proposing a mathematical modeling framework, formulated as a mixed integer linear programming model. The optimization is capable of handling multiple subsystems of batteries, considering their economic and technological performance. Decisions involve sizing of the batteries, optimal temporal and strategic dispatch to end uses, and energy sources for charging each battery. The applicability of the model is tested on four case studies for three battery chemistries representing distinct objectives: high‐power, high‐energy, and second life. Compared to traditionally designed battery storage with a homogeneous battery, optimally designed hybrid systems can save 12%–26% of system costs, depending on the nature of the dispatch profile. Findings point to design preference toward the second life battery supplemented with some high‐power or high‐energy battery capacity, or both. With the utilized electricity price structure, customers can experience approximately 10%–35% reduction in their bills.

Koleva, Mariya↗

H2Integrate [SWR-23-31]

H2Integrate(H2I) is an open-source Python package for hybrid systems engineering design and technoeconomic analysis. It models and optimizes hybrid energy plants that produce electricity, hydrogen, ammonia, steel, and other products. H2Integrate is designed to be flexible and extensible, allowing users to create their own components and models for various energy systems. The tool currently includes distributed energy generation (wind, solar, wave, tidal), battery storage, hydrogen, ammonia, methanol, and steel technologies. Other elements such as desalination systems, pipelines, compressors, and storage systems can also be included as developed by users. Some modeling capabilities in H2Integrate are provided by integrating existing tools, such as HOPP, PySAM, ORBIT, and ProFAST. The H2Integrate tool is built on top of NASA's OpenMDAO framework, which provides a powerful and flexible environment for modeling and optimization.

King, Jennifer [National Renewable Energy Laborato↗

HydroGEN Seedling: High-Temperature Reactor Catalyst Material Development for Low-Cost and Efficient Solar-Driven Sulfur-Based Processes

The HyS process, driven by solar power, has great potential to reach high-efficiency and low-cost hydrogen production without greenhouse gas emissions. The high-temperature section of the HyS cycle, which operates the catalytic decomposition of sulfuric acid into sulfur dioxide, oxygen, and water, is a fundamental part of the cycle affecting the overall plant efficiency and cost. Therefore, a high-performance catalyst (i.e., low cost, high catalytic activity, and low degradation catalyst) is of critical importance to achieve high efficiency and low hydrogen cost. Research and development has highlighted that a Pt-based monometallic catalyst had unacceptable catalytic activity and performance degradation for a high-efficiency and low-cost hydrogen production process. A high-efficiency solar receiver-reactor system, which incorporates the new catalyst, also needs to be developed to achieve the required plant efficiency and cost. Greenway Energy (GWE) and the University of South Carolina (USC), partnering with HydroGEN node laboratories Idaho National Laboratory (INL), Savannah River National Laboratory (SRNL), and National Renewable Energy Laboratory (NREL), propose the development of a new catalyst formulation, included in a novel solar receiver-reactor concept, to be tested experimentally in the last part of the project.

08 HYDROGEN↗

How Inverter-Based Resources (IBRs) Affect Protection Relay Elements

Inverter-based resources (IBRs) exhibit fault responses that differ significantly from those of synchronous generators, which can challenge the reliable operation of many commonly used power system protection elements. The fault response of IBRs is primarily influenced by their control algorithms and configurations, but the impact of these controls on protection relays is not yet fully understood. This presentation provides a comprehensive study of how IBR modeling and controls affect transmission line protection. Key modeling and control aspects include the DC source, inverter model, power level control, current control, and current limiting. The study reveals that certain aspects - such as the type of DC source (battery, PV, or hybrid), inverter model (average vs. switching), and power level control methods (PQ dispatch vs. Vdc-Vac control for grid-following IBRs, and droop vs. VSM for grid-forming IBRs) - do not significantly affect relay response. However, faster control loops, such as current control and current limiting, do influence the relay behavior. Additionally, the study explores the effects of other factors, including momentary cessation, operating points, fast/slow current responses, and grid strength on relay performance. Finally, the study offers recommendations for both IBR and protection engineers to improve IBR fault response and enhance the reliability of protection systems.

14 SOLAR ENERGY↗

A Comprehensive Study of the Impact of Inverter-Based Resource (IBR) Modeling and Control on Protection Relay Elements

Inverter-based resources (IBRs) exhibit fault responses that differ significantly from those of synchronous generators, which can challenge the reliable operation of many commonly used power system protection elements. The fault response of IBRs is primarily influenced by their control algorithms and configurations, but the impact of these controls on protection relays is not yet fully understood. This presentation provides a comprehensive study of how IBR modeling and controls affect transmission line protection. Key modeling and control aspects include the DC source, inverter model, power level control, current control, and current limiting. The study reveals that certain aspects - such as the type of DC source (battery, PV, or hybrid), inverter model (average vs. switching), and power level control methods (PQ dispatch vs. Vdc-Vac control for grid-following IBRs, and droop vs. VSM for grid-forming IBRs) - do not significantly affect relay response. However, faster control loops, such as current control and current limiting, do influence the relay behavior. Additionally, the study explores the effects of other factors, including momentary cessation, operating points, fast/slow current responses, and grid strength on relay performance. Finally, the study offers recommendations for both IBR and protection engineers to improve IBR fault response and enhance the reliability of protection systems.

14 SOLAR ENERGY↗

Energy efficiency and renewable energy utilization in desalination systems

Desalination technologies and industry have advanced significantly in the past two decades to meet the growing freshwater demands stimulated by the compounding issues of both water quality and quantity in many regions of the world. As desalination processes are energy demanding, there have been many efforts dedicated to improve energy-efficiency of the process units, enhance energy conservation and recovery, and increase renewable energy integration in desalination plants. This review article highlights recent key advances and discusses possible venues for further development in desalination energy portfolio to reduce specific energy consumption and, via integration with solar energy, to minimize the environmental footprint associated with freshwater production. First, an overview of current desalination technologies and their energy requirements are presented followed by a discussion on opportunities for improving energy efficiency and energy recovery in both membrane and thermal desalination technologies. Then, various combinations of renewable energy driven desalination plants are discussed with some recent highlights in solar energy driven membrane, thermal and hybrid desalination processes. Technological readiness levels for novel desalination processes, their perceived impact and expected near-future developments in renewable energy integrated desalination technologies are presented. Lastly, the potential for solar driven desalination as a cost-competitive freshwater supply alternative is discussed

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Dispatch for the US Virgin Islands to Increase Renewable Rates in Saint Croix

The US Virgin Islands, like many other small island nations, face significant challenges related to its energy supply. Their dependency on imported fossil fuels not only drives up energy costs, but also contributes to different environmental problems. Nevertheless, their generally sunny and windy climate makes this archipelago an ideal location for renewable energy development. Increasing the use of sources such as wind, and solar can help reduce their energy dependency, lower their levelized cost of electricity, and improve the health and wellbeing of local communities. In this paper, an optimal dispatcher is employed to analyze the implications on energy security of employing different technology options according to the plans of the local system operator. In this context, short term stability is ensured by inserting operational constraints in the energy management system based on stability analysis developed in PSCAD. The results highlight the usefulness of integrating PV and battery system, while further analysis are required to justify integrating wind power.

energy islands↗

Upgrading Biogas through in situ Conversion of Carbon Dioxide to Biomethane in Anaerobic Digesters

Organic waste streams generated by wastewater treatment plants, agricultural operations, and food processing industries represent an important yet underutilized opportunity for renewable energy production in the United States. Through anaerobic digestion, these waste streams can produce biogas, a mixture primarily composed of methane (CH4) and carbon dioxide (CO2), that can be upgraded to pipeline-quality natural gas. However, most existing upgrading technologies remove CO2 from biogas rather than utilizing it, leaving a significant portion of the potential energy unused. This project investigates a novel biological upgrading approach that converts CO2 into additional CH4 by supplying hydrogen (H2) to specialized microorganisms capable of performing hydrogenotrophic methanation. The main challenges associated with biological biogas upgrading are related to hydrogen supply, gas-liquid mass transfer, and process stability. First, due to the high cost of hydrogen gas, it is preferable that H2 be produced on-site using renewable energy sources such as wind or solar power. Second, hydrogen has low solubility in liquids, which limits its availability to microorganisms and requires strategies to improve gas dissolution and transfer within the reactor. Third, process inhibition may occur as a result of increased pH caused by CO2 consumption or elevated H2 partial pressure, both of which can negatively affect methanogenic activity. Although research in these areas has advanced during the course of this project, these challenges have not yet been fully resolved. To date, the biological systems that have achieved the highest methane concentrations are typically ex-situ reactors, where operational conditions can be more easily controlled. For this reason, the findings of the present project remain highly relevant. The project goal was to develop an innovative system that can accomplish biogas upgrading via biological conversion of CO2 to CH4, in a novel hybrid approach that combines the advantages of both in-situ and ex-situ systems. The proposed system employs a three-phase upflow anaerobic bioreactor with H2 delivery through a gas-permeable membrane, enabling efficient hydrogen transfer and microbial conversion. Under optimized operating conditions, the system achieved 99% H2 consumption and 90% CO2 conversion. A subsequent gas cleaning stage was implemented to further improve gas quality and meet target purity standards. The upgraded gas composition reached 97.7% CH4, 2.2% CO2, and 0.97% O2, while H2S concentrations remained below detection limits. In addition, a flue gas-driven inorganic thermoelectric generator (TEG) system was designed and experimentally validated as a potential source of electricity for H2 production. The system consisted of six TEG modules connected in series and achieved an open-circuit voltage of 4.5 V and a maximum power output of 224 mW at a temperature difference of approximately 53.5 °C, demonstrating effective conversion of waste heat into electrical power under simulated flue gas conditions. Finally, a comprehensive techno-economic analysis was completed to evaluate the capital and operating costs associated with the proposed system. The results provide important insights to guide future scale-up, optimization, and potential deployment of integrated biological biogas upgrading technologies.

09 BIOMASS FUELS↗

Flexible Nuclear Energy for Clean Energy Systems

As part of the Nuclear Innovation: Clean Energy Future initiative, this report describes flexibility in nuclear systems, the value it can bring, and international experiences surrounding flexible nuclear energy. Flexible nuclear energy for this report is defined as “The ability of nuclear energy generation to economically provide energy services at the time and location they are needed by end-users. These energy services can include both electric and non-electric applications utilizing both traditional nuclear power plants and advanced integrated systems.” Flexibility in nuclear systems is enabled by three main mechanisms: core ramping, integrated energy systems with multiple byproducts, and thermal storage. The value of this flexibility on a $\$$/MW and a $\$$/MWh basis can be estimated through a combination of physics and economics modeling. International agencies describe their experiences in operating flexible nuclear systems and describe their plans for increasing nuclear flexibility in a clean energy system, likely with a high penetration of variable renewable energy.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

2023 Annual Merit Review Vehicle Technologies Office Results Report

The 2023 U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy's (EERE) Vehicle Technologies Office (VTO) Annual Merit Review (AMR) was held June 12-15, 2023, as a hybrid event with in-person and virtual attendance. The review encompassed work done by VTO: 257 individual activities were reviewed by 266 reviewers. Exactly 991 individual review responses were received for the VTO technical reviews. The objective of the meeting was to review the accomplishments and plans for VTO over the previous 12 months, and provide an opportunity for industry, government, and academia to give inputs to DOE with a structured and formal methodology. The meeting also provided attendees with a virtual forum for interaction and technology information transfer.

33 ADVANCED PROPULSION SYSTEMS↗

Using Machine Learning Tools to Predict Compressor Stall

Clean energy has become an increasingly important consideration in today’s power systems. As the push for clean energy continues, many coal-fired power plants are being decommissioned in favor of renewable power sources such as wind and solar. However, the intermittent nature of renewables means that dynamic load following traditional power systems is crucial to grid stability. With high flexibility and fast response at a wide range of operating conditions, gas turbine systems are poised to become the main load following component in the power grid. Yet, rapid changes in load can lead to fluid flow instabilities in gas turbine power systems. These instabilities often lead to compressor surge and stall, which are some of the most critical problems facing the safe and efficient operation of compressors in turbomachinery today. Although the topic of compressor surge and stall has been extensively researched, no methods for early prediction have been proven effective. This study explores the utilization of machine learning tools to predict compressor stall. The long short-term memory (LSTM) model, a form of recurrent neural network (RNN), was trained using real compressor stall datasets from a 100 kW recuperated gas turbine power system designed for hybrid configuration. Two variations of the LSTM model, classification and regression, were tested to determine optimal performance. The regression scheme was determined to be the most accurate approach, and a tool for predicting compressor stall was developed using this configuration. Overall, results show that the tool is capable of predicting stalls 5–20 ms before they occur. With a high-speed controller capable of 5 ms time-steps, mitigating action could be taken to prevent compressor stall before it occurs.

42 ENGINEERING↗

2022 Annual Merit Review Report, Vehicle Technologies Office: Results Report

The 2022 U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy’s (EERE) Vehicle Technologies Office (VTO) Annual Merit Review (AMR) was held June 21-23, 2022, as a hybrid event with in-person and virtual attendance. The review encompassed work done by VTO: 213 individual activities were reviewed by 255 reviewers. Exactly 1,051 individual review responses were received for the VTO technical reviews. The objective of the meeting was to review the accomplishments and plans for VTO over the previous 12 months, and provide an opportunity for industry, government, and academia to give inputs to DOE with a structured and formal methodology. The meeting also provided attendees with a virtual forum for interaction and technology information transfer.

33 ADVANCED PROPULSION SYSTEMS↗

GRIDCERF - Geospatial Raster Input Data for Capacity Expansion Regional Feasibility

The Geospatial Raster Input Data for Capacity Expansion Regional Feasibility (GRIDCERF) data package is a high-resolution product to evaluate siting suitability for renewable and non-renewable power plants in the conterminous United States. GRIDCERF offers hundreds of individual suitability layers for use with both renewable and non-renewable power plant technology configurations in a harmonized format that can be easily ingested by geospatially-enabled modeling software. It also provides pre-compiled technology-specific suitability layers and allows for user customization to robustly address science objectives when evaluating varying future conditions. GRIDCERF data can be directly used with the CERF (Capacity Expansion Regional Feasibility) model to site power plants at a 1km resolution. GRIDCERF includes composite technology siting suitability raster layers for the following utility scale technology configurations. Note that, in addition to technology sub-types shown below, various cooling types are also included (recirculating, pond, once-through, recirculating-seawater, dry-hybrid, or dry) for various technologies. Biomass Conventional (with or without CCS) IGCC (with or without CCS) Coal Conventional (with or without CCS) IGCC (with or without CCS) Natural Gas Combined-cycle (CC) (with or without CCS) Turbine Geothermal Enhanced Geothermal Systems (EGS) - Class 1 through Class 5 resource potential Nuclear Gen 2 Light Water Reactor (LWR) Gen 3 Small Modular Reactor (SMR) Gen 3 AP1000 Refined Liquids Combined-cycle (CC) (with or without CCS) Turbine Solar Photovoltaic (PV) - for capacity factors in the range of 6-18% Utility-scale Concentrating Solar Power (CSP) - for capacity factors in the range of 24-46% Tower Wind (Onshore) - for capacity factors in the range of 5-50% 80m hub height 100m hub height 120m hub height 140m hub height Wind (Offshore) - for capacity factors in the range of 25-60% 100m hub height 140m hub height 160m hub height

capacity expansion↗

GRIDCERF - Geospatial Raster Input Data for Capacity Expansion Regional Feasibility

The Geospatial Raster Input Data for Capacity Expansion Regional Feasibility (GRIDCERF) data package is a high-resolution product to evaluate siting suitability for renewable and non-renewable power plants in the conterminous United States. GRIDCERF offers hundreds of individual suitability layers for use with both renewable and non-renewable power plant technology configurations in a harmonized format that can be easily ingested by geospatially-enabled modeling software. It also provides pre-compiled technology-specific suitability layers and allows for user customization to robustly address science objectives when evaluating varying future conditions. GRIDCERF data can be directly used with the CERF (Capacity Expansion Regional Feasibility) model to site power plants at a 1km resolution. GRIDCERF includes composite technology siting suitability raster layers for the following utility scale technology configurations. Note that, in addition to technology sub-types shown below, various cooling types are also included (recirculating, pond, once-through, recirculating-seawater, dry-hybrid, or dry) for various technologies. Biomass Conventional (with or without CCS) IGCC (with or without CCS) Coal Conventional (with or without CCS) IGCC (with or without CCS) Natural Gas Combined-cycle (CC) (with or without CCS) Turbine Geothermal Enhanced Geothermal Systems (EGS) - Class 1 through Class 5 resource potential Nuclear Gen 2 Light Water Reactor (LWR) Gen 3 Small Modular Reactor (SMR) Gen 3 AP1000 Refined Liquids Combined-cycle (CC) (with or without CCS) Turbine Solar Photovoltaic (PV) - for capacity factors in the range of 6-18% Utility-scale Concentrating Solar Power (CSP) - for capacity factors in the range of 24-46% Tower Wind (Onshore) - for capacity factors in the range of 5-50% 80m hub height 100m hub height 120m hub height 140m hub height Wind (Offshore) - for capacity factors in the range of 25-60% 100m hub height 140m hub height 160m hub height

capacity expansion↗

A deep learning-based battery sizing optimization tool for hybridizing generation plants

Hybrid generation and energy storage systems offer the ability to increase flexibility of the combined asset. This flexibility can be used to increase provision of services already provided by the generation asset, such as timing sale of electricity to the energy market during high price periods, and also enable provision of additional services, such as ancillary services or contribute to resource adequacy. From a generation asset owner perspective, the decision to hybridize includes selecting an energy storage system that, among other factors, maximizes financial performance of the energy storage investment. Yet, existing tools to optimize energy storage sizing are either too rudimentary (i.e., based on “rules of thumb”) or too complex to implement (i.e., require specialized engineering and software knowledge and a high-performance computer to run). This work presents a novel deep learning-based battery sizing optimization tool that is designed to help generation asset owners easily assess preliminary sizing considerations for potential battery investments to hybridize their generation facility. The tool uses deep learning to predict revenue over a broad search space of potential battery sizes, estimates capital and operating costs (including accounting for battery degradation), and computes financial performance of each potential battery system investment, recommending a system with maximum financial performance. The tool is tested and validated for hydropower assets. Finally, this tool will help a greater cross-section of industry consider investments in battery systems, increasing their revenue and helping them compete in rapidly evolving electrify markets.

13 HYDRO ENERGY↗

Multicarrier Energy Systems: Shaping Our Energy Future

Multicarrier energy systems (MCESs) are characterized by strong coordination in operation and planning across multiple energy vectors and/or sectors to deliver reliable, cost-effective energy services to end users/customers with minimal impact on the environment. They have efficiency and flexibility benefits and are deployed in large and small scales on the supply and demand sides and at the network level but are more complex to control and manage. Here, MCESs are reviewed in the context of future low carbon energy systems based on electrification and very high variable renewable energy penetrations. Fully exploiting these systems requires some cost reductions, more sophisticated operations enabled by standardized communications and control capabilities detailed planning paradigms, and addressing their corresponding economic challenges. All these point toward the direction of analysis, markets, and technology research and development coupled with better policy and regulatory frameworks. One futuristic vision of a very low carbon energy system is proposed that illustrates potential pathways to an MCES-dominated energy future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Prediction and Control of Atomic Ordering in Electrodeposited Binary Alloy Films: Direct Synthesis of L10 Magnetic Phases

Permanent magnet materials are essential components in renewable energy technology, underlying, electric vehicles, hybrids, wind turbines and more. Today commercial permanent magnets based on Nd-Fe-B exhibit an energy product of ~ 400 kJ/m 3 , capable to run wind turbines efficiently. Unfortunately, the supplies of rare-earth elements are centralized, and their availability may see volatility over time. This state of affairs stimulates the search for the search for rare-earth-free permanent magnetic materials. The L1 0 crystal structure underlines an important class of chemical ordered alloys that exhibit uniaxial magnetocrystalline anisotropy. This material has been considered an excellent candidate for rare-earth-free permanent magnets. In this program, a series of systematic experiments were performed and analysed in order to understand the effect of each. In order to synthesize L 10-Fe-Ni, one has to circumvent the sluggish kinetic and the limited driving force resulted from the low order-disorder temperature (~320°C) of the system. A strategy was found to trigger a martensitic transformation from the FCC phase to one of the non-cubic phases by high-strain methods. The body-centered tetragonal Fe-Ni obtained by this strategy was considered as a precursor of L10 Fe-Ni. The formation of BCT Fe-Ni via a displacive process was also implemented at the nanoscale by using tailored AuNi@FeNi core@shell.

36 MATERIALS SCIENCE↗

Co-Simulation Model for Optimal Wind-Hydro Coordination Using Wind Farm Control Dynamics

The growing share of Variable Renewable Energy sources (VRES) in power systems presents challenges for regula- tors, grid operators and energy producers. The VRES’ operation has limited flexibility in their operations, as they are highly dependent on ambient environments. To address these challenges, decision-makers must consider multiple objectives, among these are revenue, power system services and mechanical load on wind turbines. Coordinated operation of power plants and different wind farm control strategies are examples of measures that can benefit these objectives. This study proposes a Multi-Objective Linear Programming (MOLP) model to simulate the optimum operation of wind and hydropower plants that share limited transmission capacity. Further, wind farm control dynamics are included to obtain realistic output power and accumulated damage. From this, a case study based on a relevant location in Norway is presented to analyze the improved effect of wind- hydro coordination and wind farm control in achieving the objectives of accumulated wind turbine damage and total revenue of the hybrid power system. In addition, the study considers the potential advantages of adding a variable-speed pump to the hydropower plant. The results demonstrate that by considering multiple objectives in the optimization, one may achieve better overall performance of the objectives. By utilizing the flexibility of hydro storage, the decision maker may adjust to obtain the most desired outcome. Moreover, the added flexibility of utilizing a pump for hydro storage shows great improvements for the combined revenue of the power plants and reduced curtailment of the wind farm. However, less impact is observed from using a variable speed pump compared to a fixed speed pump.

13 HYDRO ENERGY↗