Search NASA⌕ Search

SEARCH · Search NASA

Results for “image sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Polarization Imaging Apparatus with Auto-Calibration

A polarization imaging apparatus measures the Stokes image of a sample. The apparatus consists of an optical lens set, a first variable phase retarder (VPR) with its optical axis aligned 22.5 deg, a second variable phase retarder with its optical axis aligned 45 deg, a linear polarizer, a imaging sensor for sensing the intensity images of the sample, a controller and a computer. Two variable phase retarders were controlled independently by a computer through a controller unit which generates a sequential of voltages to control the phase retardations of the first and second variable phase retarders. A auto-calibration procedure was incorporated into the polarization imaging apparatus to correct the misalignment of first and second VPRs, as well as the half-wave voltage of the VPRs. A set of four intensity images, I(sub 0), I(sub 1), I(sub 2) and I(sub 3) of the sample were captured by imaging sensor when the phase retardations of VPRs were set at (0,0), (pi,0), (pi,pi) and (pi/2,pi), respectively. Then four Stokes components of a Stokes image, S(sub 0), S(sub 1), S(sub 2) and S(sub 3) were calculated using the four intensity images.

Zou, Yingyin Kevin↗

Polarization imaging apparatus with auto-calibration

A polarization imaging apparatus measures the Stokes image of a sample. The apparatus consists of an optical lens set, a first variable phase retarder (VPR) with its optical axis aligned 22.5.degree., a second variable phase retarder with its optical axis aligned 45.degree., a linear polarizer, a imaging sensor for sensing the intensity images of the sample, a controller and a computer. Two variable phase retarders were controlled independently by a computer through a controller unit which generates a sequential of voltages to control the phase retardations of the first and second variable phase retarders. A auto-calibration procedure was incorporated into the polarization imaging apparatus to correct the misalignment of first and second VPRs, as well as the half-wave voltage of the VPRs. A set of four intensity images, I.sub.0, I.sub.1, I.sub.2 and I.sub.3 of the sample were captured by imaging sensor when the phase retardations of VPRs were set at (0,0), (.pi.,0), (.pi.,.pi.) and (.pi./2,.pi.), respectively. Then four Stokes components of a Stokes image, S.sub.0, S.sub.1, S.sub.2 and S.sub.3 were calculated using the four intensity images.

47 OTHER INSTRUMENTATION↗

Precipitable water and surface humidity over global oceans from special sensor microwave imager and European Center for Medium Range Weather Forecasts

Global fields of precipitable water W from the special sensor microwave imager were compared with those from the European Center for Medium Range Weather Forecasts (ECMWF) model. They agree over most ocean areas; both data sets capture the two annual cycles examined and the interannual anomalies during an ENSO episode. They show significant differences in the dry air masses over the eastern tropical-subtropical oceans, particularly in the Southern Hemisphere. In these regions, comparisons with radiosonde data indicate that overestimation by the ECMWF model accounts for a large part of the differences. As a check on the W differences, surface-level specific humidity Q derived from W, using a statistical relation, was compared with Q from the ECMWF model. The differences in Q were found to be consistent with the differences in W, indirectly validating the Q-W relation. In both W and Q, SSMI was able to discern clearly the equatorial extension of the tongues of dry air in the eastern tropical ocean, while both ECMWF and climatological fields have reduced spatial gradients and weaker intensity.

Liu, W. T.↗

New geophysical algorithms for the special sensor microwave imager

A unified set of algorithms for the estimation of atmospheric parameters over the ocean is assembled, making it possible to apply data from the Special Sensor Microwave Imager (SSM/I) to case studies of weather systems over the ocean. The problems of sensor resolution and cross-parameter contamination are examined. The usefulness of the algorithms for obtaining the surface-wind-speed fields, integrated water vapor, cloud liquid water, and precipitation from SSM/I brightness temperature data over the ocean is demonstrated.

Petty, Grant W.↗

Evaluating fusion techniques for multi-sensor satellite image data

Satellite image data fusion is a topic of interest in many areas including environmental monitoring, emergency response, and defense. Typically any single satellite sensor cannot provide all of the benefits offered by a combination of different sensors (e.g., high-spatial but low spectral resolution vs. low-spatial but high spectral, optical vs. SAR). Given the respective strengths and weaknesses of the different types of image data, it is beneficial to fuse many types of image data to extract as much information as possible from the data. Our work focuses on the fusion of multi-sensor image data into a unified representation that incorporates the potential strengths of a sensor in order to minimize classification error. Of particular interest is the fusion of optical and synthetic aperture radar (SAR) images into a single, multispectral image of the best possible spatial resolution. We explore various methods to optimally fuse these images and evaluate the quality of the image fusion by using K-means clustering to categorize regions in the fused images and comparing the accuracies of the resulting categorization maps.

Martin, Benjamin W↗

Direct-Solve Image-Based Wavefront Sensing

A method of wavefront sensing (more precisely characterized as a method of determining the deviation of a wavefront from a nominal figure) has been invented as an improved means of assessing the performance of an optical system as affected by such imperfections as misalignments, design errors, and fabrication errors. The method is implemented by software running on a single-processor computer that is connected, via a suitable interface, to the image sensor (typically, a charge-coupled device) in the system under test. The software collects a digitized single image from the image sensor. The image is displayed on a computer monitor. The software directly solves for the wavefront in a time interval of a fraction of a second. A picture of the wavefront is displayed. The solution process involves, among other things, fast Fourier transforms. It has been reported to the effect that some measure of the wavefront is decomposed into modes of the optical system under test, but it has not been reported whether this decomposition is postprocessing of the solution or part of the solution process.

Lyon, Richard G.↗

NASA sea ice validation program for the Defense Meteorological Satellite Program special sensor microwave imager

Attention is given to the prime objective of the NASA validation program, namely, to establish quantitative relationships between the sea ice parameters derived from the special sensor microwave imager (SSM/I) using an algorithm originally developed for the Nimbus 7 SMMR. The underlying philosophy of the validation program is that confidence in the SSM/I algorithm products is achieved not so much by detailed comparison with localized surface observations as by consistency with independent spatially and temporally coincident data sets. The results of the satellite and aircraft comparisons that serve as the basis for the validation of the NASA SSMI/I sea ice algorithm are presented. High-resolution radiometer and C-band SAR imagery from the March 1988 NASA and Navy SSM/I underflights are used to verify the location of the ice edge and to validate the sea ice concentrations as determined by the SSM/I algorithm. These studies are argued to provide the most comprehensive measure to date of the accuracy of sea ice products derived from a spaceborne multichannel microwave imager.

Cavalieri, Donald J.↗

Image-based occupancy sensor

An image-based occupancy sensor includes a motion detection module that receives and processes an image signal to generate a motion detection signal, a people detection module that receives the image signal and processes the image signal to generate a people detection signal, a face detection module that receives the image signal and processes the image signal to generate a face detection signal, and a sensor integration module that receives the motion detection signal from the motion detection module, receives the people detection signal from the people detection module, receives the face detection signal from the face detection module, and generates an occupancy signal using the motion detection signal, the people detection signal, and the face detection signal, with the occupancy signal indicating vacancy or occupancy, with an occupancy indication specifying that one or more people are detected within the monitored volume.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Polarization imaging apparatus

A polarization imaging apparatus measures the Stokes image of a sample. The apparatus consists of an optical lens set 11, a linear polarizer 14 with its optical axis 18, a first variable phase retarder 12 with its optical axis 16 aligned 22.5.degree. to axis 18, a second variable phase retarder 13 with its optical axis 17 aligned 45.degree. to axis 18, a imaging sensor 15 for sensing the intensity images of the sample, a controller 101 and a computer 102. Two variable phase retarders 12 and 13 were controlled independently by a computer 102 through a controller unit 101 which generates a sequential of voltages to control the phase retardations of VPRs 12 and 13. A set of four intensity images, I.sub.0, I.sub.1, I.sub.2 and I.sub.3 of the sample were captured by imaging sensor 15 when the phase retardations of VPRs 12 and 13 were set at (0,0), (.pi.,0), (.pi.,.pi.) and (.pi./2,.pi.), respectively Then four Stokes components of a Stokes image, S.sub.0, S.sub.1, S.sub.2 and S.sub.3 were calculated using the four intensity images.

Zou, Yingyin Kevin↗

An analysis of errors in special sensor microwave imager evaporation estimates over the global oceans

The method proposed by Liu (1984) is used to estimate monthly averaged evaporation over the global oceans from 1 yr of special sensor microwave imager (SDSM/I) data. Intercomparisons involving SSM/I and in situ data are made over a wide range of oceanic conditions during August 1987 and February 1988 to determine the source of errors in the evaporation estimates. The most significant spatially coherent evaporation errors are found to come from estimates of near-surface specific humidity, q. Systematic discrepancies of over 2 g/kg are found in the tropics, as well as in the middle and high latitudes. The q errors are partitioned into contributions from the parameterization of q in terms of the columnar water vapor, i.e., the Liu q/W relationship, and from the retrieval algorithm for W. The effects of W retrieval errors are found to be smaller over most of the global oceans and due primarily to the implicitly assumed vertical structures of temperature and specific humidity on which the physically based SSM/I retrievals of W are based.

Esbensen, S. K.↗

Camera-on-a-Chip

Jet Propulsion Laboratory's research on a second generation, solid-state image sensor technology has resulted in the Complementary Metal- Oxide Semiconductor Active Pixel Sensor (CMOS), establishing an alternative to the Charged Coupled Device (CCD). Photobit Corporation, the leading supplier of CMOS image sensors, has commercialized two products of their own based on this technology: the PB-100 and PB-300. These devices are cameras on a chip, combining all camera functions. CMOS "active-pixel" digital image sensors offer several advantages over CCDs, a technology used in video and still-camera applications for 30 years. The CMOS sensors draw less energy, they use the same manufacturing platform as most microprocessors and memory chips, and they allow on-chip programming of frame size, exposure, and other parameters.

Source record↗

NASA team algorithm for sea ice concentration retrieval from Defense Meteorological Satellite Program special sensor microwave imager - Comparison with Landsat satellite imagery

The present study describes the validation of the the NASA team algorithm for the determination of sea ice concentrations from the Defense Meteorological Satellite Program special sensor microwave imager (SSM/I). A total of 28 cloud-free Landsat scenes were selected to permit validation of the passive microwave ice concentration algorithm for a range of ice concentrations and ice types. The sensitivity of the NASA team algorithm to the selection of locally and seasonally adjusted algorithm parameters is discussed. Mean absolute differences between SSM/I and Landsat ice concentrations are within 1 percent during fall using local and global tie points (standard deviations of the difference are +/-3.1 and +/-6.2 percent, respectively). In areas with greater amounts of nilas and young ice, the NASA team algorithm was found to underestimate ice concentrations by as much as 9 percent. It is inferred that the standard deviation between SSM/I and Landsat ice concentrations decreases from +/-7 to +/-5 percent with local tie points compared to the global ones for spring and fall.

Steffen, Konrad↗

Validation of Special Sensor Microwave Imager monthly-mean wind speed from July 1987 to December 1989

Since July 1987, the Remote Sensing Systems (Santa Rosa, California) routinely computes from first principles the wind speed from Special Sensor Microwave Imager (SSM/I) measurements of the intensity of microwave radiation emitted at the ocean surface. The accuracy of monthly-mean SSM/I wind speeds is determined by comparisons with moored-buoy wind measurements, which were recorded by four different institutions at 44 sites in the Atlantic and Pacific Oceans during July 1987 to December 1989. All results for 1988 were virtually identical with 1989. The range of monthly mean moored-buoy wind speeds was 2-10 m/s. The rms difference of 697 monthly-mean matchups of the composite 1988 and 1989 data set was 1.2 m/s. The rms differences were smaller in the equatorial zone and higher in middle latitudes, in accord with the monthly standard deviation. At middle latitudes, the time series of rms differences displayed an annual cycle. In the equatorial zone, the agreement between SSM/I and in situ data was better in regions with a lesser amount of clouds, and vice versa. For SSM/I monthly standard deviations of 1-2, 2-3, and 3-4 m/s, the average absolute values of the monthly-mean difference between SSM/I and moored-buoy wind speeds were 0.6, 0.9, and 1.4 m/s, respectively.

Halpern, David↗

Validation of Special Sensor Microwave Imager Monthly-Mean Wind Speed From July 1987 to December 1989

Since July 1987 the Remote Sensing Systems, Santa Rosa, California, routinely computes from first principles the wind speed from Special Sensor Microwave Imager (SSM/I) measurements of the intensity of microwave radiation emitted at the ocean surface. The accuracy of monthly-mean SSM/I wind speeds is determined by comparisons with moored-buoy wind measurements, which were recorded by four different institutions at 44 sites in the Atlantic and Pacific Oceans during July 1987 to December 1989. All results for 1988 were virtually identical with 1989. The range of monthly mean moored-buoy wind speeds was 2-10 m s^(-1). During 1987, the equatorial matchups were not equivalent with 1998 and 1989, and the cause remains unknown. The root-mean-square (rms) difference of 697 monthly-mean matchups of the composite 1988 and 1989 data set was 1.2 m s^(-1). The rms differences were smaller in the equatorial zone and higher in middle latitudes, in accord with the monthly standard deviation. At middle latitudes the time series of rms differences displayed an annual cycle. In the equatorial zone the agreement between SSM/I and in situ data was better in regions with a lesser amount of clouds, and vice versa. For SSM/I monthly standard deviations of 1-2, 2-3, and 3-4 m s^(-1), the average absolute values of the monthly-mean difference between SSM/I and moored-buoy wind speeds were 0.6, 0.9, and 1.4 m s^(-1), respectively.

Halpern, D.↗

A model for atmospheric brightness temperatures observed by the special sensor microwave imager (SSM/I)

A closed-form mathematical model for the atmospheric contribution to microwave the absorption and emission at the SSM/I frequencies is developed in order to improve quantitative interpretation of microwave imagery from the Special Sensor Microwave Imager (SSM/I). The model is intended to accurately predict upwelling and downwelling atmospheric brightness temperatures at SSM/I frequencies, as functions of eight input parameters: the zenith (nadir) angle, the integrated water vapor and vapor scale height, the integrated cloud water and cloud height, the effective surface temperature, atmospheric lapse rate, and surface pressure. It is shown that the model accurately reproduces clear-sky brightness temperatures computed by explicit integration of a large number of radiosonde soundings representing all maritime climate zones and seasons.

Petty, Grant W.↗

High-speed multi-frame dynamic transmission electron microscope image acquisition system with arbitrary timing

An electron microscope is disclosed which has a laser-driven photocathode and an arbitrary waveform generator (AWG) laser system ("laser"). The laser produces a train of temporally-shaped laser pulses each being of a programmable pulse duration, and directs the laser pulses to the laser-driven photocathode to produce a train of electron pulses. An image sensor is used along with a deflector subsystem. The deflector subsystem is arranged downstream of the target but upstream of the image sensor, and has a plurality of plates. A control system having a digital sequencer controls the laser and a plurality of switching components, synchronized with the laser, to independently control excitation of each one of the deflector plates. This allows each electron pulse to be directed to a different portion of the image sensor, as well as to enable programmable pulse durations and programmable inter-pulse spacings.

36 MATERIALS SCIENCE↗