Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Multiscale aperture synthesis imager

Synthetic aperture imaging has enabled breakthrough observations from radar to astronomy. However, optical implementation remains challenging due to stringent wavefield synchronization requirements among multiple receivers. Here we present the multiscale aperture synthesis imager (MASI), which utilizes parallelism to break complex optical challenges into tractable sub-problems. MASI employs a distributed array of coded sensors that operate independently yet coherently to surpass the diffraction limit of single receiver. It combines the propagated wavefields from individual sensors through a computational phase synchronization scheme, eliminating the need for overlapping measurement regions to establish phase coherence. Light diffraction in MASI naturally expands the imaging field, generating phase-contrast visualizations that are substantially larger than sensor dimensions. Without using lenses, MASI resolves sub-micron features at ultralong working distances and reconstructs 3D shapes over centimeter-scale fields. MASI transforms the intractable optical synchronization problem into a computational one, enabling practical deployment of scalable synthetic aperture systems at optical wavelengths.

electrical and electronic engineering↗

A comparison of histopathology imaging comprehension algorithms based on multiple instance learning

Whole slide imaging (WSI), also called digital virtual microscopy, is a new imaging modality. It allows for the application of AI and machine learning methods to cancer pathology to help establish a means for the automatic diagnosis of cancer cases. However, designing machine-learning models for WSI is computationally challenging due to its required ultra-high resolution. The current state-of-the-art models use multiple instance learning (MIL). MIL is a weakly-supervised learning method in which the model uses an array of inferences from many smaller instances to make a final classification about the entire set. In the context of WSI, researchers divide the ultra-high-resolution image into many patches. The model then classifies the slide based on an array of inferences from the patches. Among several ways of making the final classification, attention-based mechanisms have resulted in superb accuracy scores. The Transformer, one attention-based algorithm, has reported substantial improvements for WSI comprehension tasks. In this project, we studied and compared several WSI comprehension algorithms. We used the following three datasets: CAMELYON16+17, TCGALung, and TCGA-Kidney. We found that attention-based MIL algorithms performed better than standard MIL algorithms for classifying WSI images, achieving a higher mean accuracy and AUC. However, none of the attention-based algorithms performed significantly better than the others, reporting accuracy scores that varied widely. Presumably, it is due to the limited availability of training samples in the data corpus. Since it is not easy to increase the samples from human subjects, some machine learning techniques like transfer learning could help mitigate this issue.

Saunders, Adam↗

Accelerating Markov Chain Monte Carlo sampling with diffusion models

Global fits of physics models require efficient methods for exploring high-dimensional and/or multimodal posterior functions. We introduce a novel method for accelerating Markov Chain Monte Carlo (MCMC) sampling by pairing a Metropolis-Hastings algorithm with a diffusion model that can draw global samples with the aim of approximating the posterior. We briefly review diffusion models in the context of image synthesis before providing a streamlined diffusion model tailored towards low-dimensional data arrays. We then present our adapted Metropolis-Hastings algorithm which combines local proposals with global proposals taken from a diffusion model that is regularly trained on the samples produced during the MCMC run. Our approach leads to a significant reduction in the number of likelihood evaluations required to obtain an accurate representation of the Bayesian posterior across several analytic functions, as well as for a physical example based on a global fit of parton distribution functions. Our method is extensible to other MCMC techniques, and we briefly compare our method to similar approaches based on normalising flows. A code implementation can be found at https://github.com/NickHunt-Smith/MCMC-diffusion.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A horseshoe-shaped ring of diffuse emission detected at 1.4 GHz

We identify a horseshoe-shaped ring (HSR) of diffuse emission in J1407+0453 from the Faint Images of Radio Sky at Twenty-cm (FIRST) survey using the Very Large Array telescope at 1.4 GHz. An optical galaxy, SDSS J140709.01+045302.1, is present near the limb of the HSR of J1407+0453, with a spectroscopic redshift ofz = 0.13360. The total extent of the source, including the diffuse emission of J1407+0453, is 65 arcsec (with a physical extent of 160 kpc), whereas the diameter of the HSR is approximately 10 arcsec (25 kpc). The flux density of the HSR is ∼47 mJy at 1400 MHz, whereas the flux densities of the whole diffuse emission of J1407+0453 at 1400 MHz and 150 MHz are 172 mJy and 763 mJy, respectively. We measure the radio luminosity of HSR J1407+0453 as 1.94 × 10 24 W Hz −1 , with a spectral index,α 150 1400 = −0.67. The black hole mass of J1407+0453 is 5.8 × 10 8 M ⊙ . We compare the HSR of diffuse emission of J1407+0453 with other discovered diffuse circular sources. The possible formation scenarios for J1407+0453 are discussed, so as to understand the nature of the source. We present a spectral index map of source J147+0453 to study the spectral properties of the source.

Astronomy & Astrophysics↗

Soft x-ray spectrum unfold of K-edge filtered x-ray diode arrays using cubic splines

Cubic spline interpolation is able to recover temporally and spectrally resolved soft x-ray flux from an array of K-edge filtered x-ray diodes without the need for a priori assumptions about the spectrum or the geometry of the emitting volume. The mathematics of the cubic spline interpolation is discussed in detail. The analytic nature of the cubic spline solution allows for analytical error propagation, and the method of calculating the error for radiation temperature, spectral power, and confidence intervals of the unfolded spectrally resolved flux is explained. An unfold of a blackbody model demonstrates the accuracy of the cubic spline unfold. Tests of cubic spline performance using spectrally convolved detailed atomic model simulation results have been performed to measure the method's ability to conserve spectral power to within a factor of 2 or better in line-dominated regimes. The unfold is also demonstrated to work when information from the x-ray diode array is limited due to high signal-to-noise ratios or lack of signal due to over-attenuation or over-filtration of the x-ray diode signal. Here, the robustness of the unfold with respect to background subtraction and raw signal processing, signal alignment between diode traces, limited signal information, and initial conditions is discussed. Results from an example analysis of a halfraum drive are presented to demonstrate the capabilities of the unfold in comparison with previously established methods.

47 OTHER INSTRUMENTATION↗

Associative memories using complex-valued Hopfield networks based on spin-torque oscillator arrays

Abstract Simulations of complex-valued Hopfield networks based on spin-torque oscillators can recover phase-encoded images. Sequences of memristor-augmented inverters provide tunable delay elements that implement complex weights by phase shifting the oscillatory output of the oscillators. Pseudo-inverse training suffices to store at least 12 images in a set of 192 oscillators, representing 16 × 12 pixel images. The energy required to recover an image depends on the desired error level. For the oscillators and circuitry considered here, 5% root mean square deviations from the ideal image require approximately 5 μ s and consume roughly 130 nJ. Simulations show that the network functions well when the resonant frequency of the oscillators can be tuned to have a fractional spread less than 10 −3 , depending on the strength of the feedback.

Prasad, Nitin (ORCID:0000000180880164)↗

Formation of Complex Spin Textures in Thermally Demagnetized La 0.7 Sr 0.3 Mn O 3 Artificial-Spin-Ice Structures

Artificial spin ices (ASIs) have traditionally been designed such that each nanomagnet possesses a single-domain magnetic configuration that is assumed to be minimally perturbed by interisland dipolar interactions. Using x-ray photoemission electron microscopy to perform magnetic domain imaging, we study thermally demagnetized La 0.7 Sr 0.3 MnO 3 -based brickwork ASI arrays and showed that complex spin textures (CSTs) can be stabilized through an appropriate selection of nanoisland width and interisland spacing. While the width dependence can be explained through the dominance of shape anisotropy in isolated nanoislands, the ASIs we investigate demonstrate a complex dependence on both the nanoisland width and interisland spacing. Micromagnetic simulations reveal that interisland dipolar interactions play a role in the formation of CSTs, which are composed of single- and double-vortex states. Furthermore, energy analysis of the simulations provides an understanding of the system energetics that arises from a delicate balance between intraisland effects (i.e., shape anisotropy and exchange energy) and interisland effects (i.e., dipolar interactions between nearest-neighbor nanoislands).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Minimizing Timing Jitter’s Impact on Ground-Penetrating Radar Array Coupling Signals

This article presents a novel investigation into the effect of receiver timing jitter on the quality of imaging of ground-penetrating radar systems. We explicitly show the impact of timing jitter throughout an entire example processing pipeline. The process of coupling removal in systems whose receivers have a random Gaussian-distributed jitter with a high standard deviation leaves randomly distributed residue in the radar image. This residue, called jitter-induced coupling noise, extends even into the expected target domain which may cause false alarms. This residue approximately follows a sum of Gaussian and Gamma distributions based on the higher order derivatives of the coupling signal. Once migrated to create an image, the coupling residue is best described by a Weibull distribution. We show that simple filtering does not remove enough residue and propose two preventative design specifications called the linear slope and migrated probability specifications. Antenna and system designers should use these specifications to assess the true severity of coupling signals in a given jitter environment.

47 OTHER INSTRUMENTATION↗

Compact single-shot soft X-ray photon spectrometer for free-electron laser diagnostics

The photon spectrum from free-electron laser (FEL) light sources offers valuable information in time-resolved experiments and machine optimization in the spectral and temporal domains. We have developed a compact single-shot photon spectrometer to diagnose soft X-ray spectra. The spectrometer consists of an array of off-axis Fresnel zone plates (FZP) that act as transmission-imaging gratings, a Ce:YAG scintillator, and a microscope objective to image the scintillation target onto a two-dimensional imaging detector. This spectrometer operates in segmented energy ranges which covers tens of electronvolts for each absorption edge associated with several atomic constituents: carbon, nitrogen, oxygen, and neon. The spectrometer’s performance is demonstrated at a repetition rate of 120 Hz, but our detection scheme can be easily extended to 200 kHz spectral collection by employing a fast complementary metal oxide semiconductor (CMOS) line-scan camera to detect the light from the scintillator. This compact photon spectrometer provides an opportunity for monitoring the spectrum downstream of an endstation in a limited space environment with sub-electronvolt energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Micro-imaging with an atomic magnetometer and flux guide

Micro-imaging may be performed with an ultra-sensitive atomic magnetometer (AM) and an array of flux guides (FGs). The array of FGs may be configured to act as a magnetic lens that expands microscopic magnetic distribution to match dimensions of the AM. A plurality of single channel AMs may be combined into an array, or the AM may include an array of photodetectors, to realize multi-channel operation.

47 OTHER INSTRUMENTATION↗

Imaging the magnetic nanowire cross section and magnetic ordering within a suspended 3D artificial spin-ice

Artificial spin-ice systems are patterned arrays of magnetic nanoislands arranged into frustrated geometries and provide insight into the physics of ordering and emergence. The majority of these systems have been realized in two-dimensions, mainly due to the ease of fabrication, but with recent developments in advanced nanolithography, three-dimensional artificial spin ice (ASI) structures have become possible, providing a new paradigm in their study. Such artificially engineered 3D systems provide new opportunities in realizing tunable ground states, new domain wall topologies, monopole propagation, and advanced device concepts, such as magnetic racetrack memory. Direct imaging of 3DASI structures with magnetic force microscopy has thus far been key to probing the physics of these systems but is limited in both the depth of measurement and resolution, ultimately restricting measurement to the uppermost layers of the system. In this work, a method is developed to fabricate 3DASI lattices over an aperture using two-photon lithography, thermal evaporation, and oxygen plasma exposure, allowing the probe of element-specific structural and magnetic information using soft x-ray microscopy with x-ray magnetic circular dichroism (XMCD) as magnetic contrast. The suspended polymer–permalloy lattices are found to be stable under repeated soft x-ray exposure. Analysis of the x-ray absorption signal allows the complex cross section of the magnetic nanowires to be reconstructed and demonstrates a crescent-shaped geometry. Measurement of the XMCD images after the application of an in-plane field suggests a decrease in magnetic moment on the lattice surface due to oxidation, while a measurable signal is retained on sub-lattices below the surface.

36 MATERIALS SCIENCE↗

Design and performance of the first IceAct demonstrator at the South Pole

Here in this paper we describe the first results of IceAct, a compact imaging air-Cherenkov telescope operating in coincidence with the IceCube Neutrino Observatory (IceCube) at the geographic South Pole. An array of IceAct telescopes (referred to as the IceAct project) is under consideration as part of the IceCube-Gen2 extension to IceCube. Surface detectors in general will be a powerful tool in IceCube-Gen2 for distinguishing astrophysical neutrinos from the dominant backgrounds of cosmic-ray induced atmospheric muons and neutrinos: the IceTop array is already in place as part of IceCube, but has a high energy threshold. Although the duty cycle will be lower for the IceAct telescopes than the present IceTop tanks, the IceAct telescopes may prove to be more effective at lowering the detection threshold for air showers. Additionally, small imaging air-Cherenkov telescopes in combination with IceTop, the deep IceCube detector or other future detector systems might improve measurements of the composition of the cosmic ray energy spectrum. In this paper we present measurements of a first 7-pixel imaging air Cherenkov telescope demonstrator, proving the capability of this technology to measure air showers at the South Pole in coincidence with IceTop and the deep IceCube detector.

47 OTHER INSTRUMENTATION↗

Characterization of a Pixelated Cadmium Telluride Detector System Using a Polychromatic X-Ray Source and Gold Nanoparticle-Loaded Phantoms for Benchtop X-Ray Fluorescence Imaging

In this paper, the imaging dose and scan time have been considered as the two major constraints for routine benchtop x-ray fluorescence computed tomography (XFCT) imaging. One way to address this issue is to acquire x-ray fluorescence (XRF) signals in parallel through a 2D array of single-crystal detectors or a pixelated detector along with the cone-beam x-ray source. To identify a detector system suitable for this purpose, a commercially available, fully spectroscopic cadmium telluride (CdTe) pixelated detector, HEXITEC (High-Energy X-ray Imaging Technology), was tested under the experimental conditions optimized for benchtop XFCT imaging of gold nanoparticles (GNPs). Specifically, two different parallel-hole stainless steel collimators were fabricated and coupled with the detector for seamless integration into our existing benchtop cone-beam XFCT system. After the detector deployment, this benchtop XFCT system was used to detect XRF photons from GNP-loaded phantoms. A pixel-merging algorithm was introduced to enhance the sensitivity of XRF photon detection thereby minimizing the scan time. The effect of pixel-level charge sharing correction algorithms was investigated within the context of benchtop XFCT imaging. The detector energy resolution, in terms of the full width at half maximum (FWHM) values at different gold K-shell XRF energies, was also determined. Of the two charge sharing correction algorithms examined, the charge sharing addition gave better sensitivity than the charge sharing discrimination (csd). On the other hand, under the current experimental conditions, the energy resolution of the HEXITEC detector was the best with the csd and estimated to be 1.56 keV FWHM at 66-69 keV photon energy. Overall, despite some degradation of the detector energy resolution (compared with typical single crystal CdTe detectors), the HEXITEC detector enabled parallel data acquisition under the experimental conditions typical of benchtop XFCT imaging and operated well within our benchtop XFCT setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Brighter-fatter Effect in Near-infrared Detectors—III. Fourier-domain Treatment of Flat Field Correlations and Application to WFIRST

Weak gravitational lensing has emerged as a leading probe of the growth of cosmic structure. However, the shear signal is very small and accurate measurement depends critically on our ability to understand how non-ideal instrumental effects affect astronomical images. The Wide-Field Infrared Survey Telescope (WFIRST) will fly a focal plane containing 18 Teledyne H4RG-10 near-infrared detector arrays, which present different instrument calibration challenges from previous weak lensing observations. Previous work [Paper I: Hirata & Choi, PASP, 132, 014501 (2020); and Paper II: Choi & Hirata, PASP, 132, 014502 (2020)] has shown that correlation functions of flat field images, including cross-correlations between different time slices that are enabled by the non-destructive read capability of the infrared detectors, are effective tools for disentangling linear and nonlinear inter-pixel capacitance (IPC) and the brighter-fatter effect (BFE). Here we present a Fourier-domain treatment of the flat field correlations, which allows us to expand the previous formalism to all orders in IPC, BFE, and classical nonlinearity. We show that biases in simulated flat field analyses in Paper I are greatly reduced through the use of this formalism. We then apply this updated formalism to flat field data from three WFIRST flight candidate detectors, and explore the robustness to variations in the analysis. We find that the BFE is present in all three detectors, and that its contribution to the flat field correlations dominates over the nonlinear IPC, in accordance with the results from Paper II on a development detector. The magnitude of the BFE is such that the effective area of a pixel is increased by (3.54 ± 0.03) × 10 -7 for every electron deposited in a neighboring pixel (sensor chip assembly [SCA] 20829, statistical error, not IPC-deconvolved). We compare IPC maps from flat field autocorrelation measurements to those obtained from the single pixel reset method and find a median difference of 0.113% for SCA 20829. After further diagnosis of this difference, we ascribe it largely to an additional source of cross-talk, the vertical trailing pixel effect, and recommend further work to develop a model for this effect. These results represent a significant step toward calibration of the non-ideal effects in WFIRST detectors.

79 ASTRONOMY AND ASTROPHYSICS↗

Fresnel zone plate development for x-ray radiography of hydrodynamic instabilities at the National Ignition Facility

The study of Rayleigh–Taylor (RT) and Richtmyer–Meshkov (RM) instabilities in a planar geometry at high energy densities at the National Ignition Facility (NIF) requires high spatial resolution imaging. We demonstrate the potential of Fresnel zone plates (FZPs) to achieve resolution that would unlock such studies. FZPs are circular aperiodic gratings that use diffraction to focus x rays and produce an image with high spatial resolution. Taking into account the NIF’s challenging environment, we have designed a specific array of five FZPs for a zinc backlighter to take a radiograph of a target with 9 keV x rays. We measured a mean resolution for the FZP of 1.9µm±0.5µm and a ±1mm depth of focus at an x-ray calibration facility as well as a 2.3µm±0.4µm resolution on a resolution wire mesh shot on the NIF. We also performed an in-depth analysis of the image quality to assess the capability to resolve the small features present in RT and RM instabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Femtosecond photoemission electron microscopy of surface plasmon polariton beam steering via nanohole arrays

Directional control over surface plasmon polariton (SPP) waves is a prerequisite for the development of miniaturized optical circuitry. Here, the efficacy of single and dual component SPP steering elements is explored through photoemission electron microscopy. Our imaging scheme relies on two-color photoemission and counter-propagating SPP generation, which collectively allow SPPs to be visualized in real space. Wave-vector difference mixing between two-dimensional arrays of nanoholes and photon momenta enables SPP steering with directionality governed by the array lattice constant. The magnitude of grating momentum required to achieve counter-propagation guarantees efficient steering over the full range of the negative half-space. In our dual component configuration, separate SPP generation and Bragg diffraction based steering optics are employed. We find that array Bragg planes principally influence the SPP angles through the array band structure, which allows us to visualize both positive and negative refractory waves.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Advanced Mixed-Mode Pixel Array Detector for X-rays Above 20 keV (Final Report)

The objective of the work reported upon was to perform research and development and test advanced prototype imaging x-ray detectors needed to meet pressing scientific research needs at U.S. x-ray synchrotron user facilities. The high x-ray brightness of the Nation’s x-ray synchrotron sources in the DOE National Laboratories holds promise to advance science and technology in a broad range of fundamental and applied disciplines, including physics, chemistry, biomedical areas and engineering. At present, progress in many areas is being limited not by the x-ray source but by the lack of imaging x-ray detectors capable of meeting experimental needs. Specifically, there is pressing need for imaging detectors with high dynamic range, low noise, high frame rates and the ability to capture x-ray images with x-rays of energy > 20 keV. This Final Technical Report summarizes progress made at Cornell University on novel integrating x-ray detectors that address these characteristics.

36 MATERIALS SCIENCE↗

Multi-beam X-ray ptychography for high-throughput coherent diffraction imaging

X-ray ptychography is a rapidly developing coherent diffraction imaging technique that provides nanoscale resolution on extended field-of-view. However, the requirement of coherence and the scanning mechanism limit the throughput of ptychographic imaging. Herein, we propose X-ray ptychography using multiple illuminations instead of single illumination in conventional ptychography. Multiple locations of the sample are simultaneously imaged by spatially separated X-ray beams, therefore, the obtained field-of-view in one scan can be enlarged by a factor equal to the number of illuminations. We have demonstrated this technique experimentally using two X-ray beams focused by a house-made Fresnel zone plate array. Two areas of the object and corresponding double illuminations were successfully reconstructed from diffraction patterns acquired in one scan, with image quality similar with those obtained by conventional single-beam ptychography in sequence. Multi-beam ptychography approach increases the imaging speed, providing an efficient way for high-resolution imaging of large extended specimens.

47 OTHER INSTRUMENTATION↗