Search NASA⌕ Search

SEARCH · Search NASA

Results for “information spectrum method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Incorporating Beam Attenuation Calculations into an Integrated Data Analysis Model for Ion Effective Charge

Here, we have created a forward model for charge-exchange impurity density measurements that incorporates neutral beam attenuation measurements self-consistently for the purpose of determining the ion-effective charge Z eff . The model is constructed within an integrated data analysis framework to include a self-consistent calculation of neutral beam attenuation due to multiple impurity species into the measurement of a single impurity density. The model includes measurements of the beam Doppler-shift spectrum and shine-through particle flux to determine the neutral beam particle density which is attenuated by ion collisions. Synthetic data are generated from the diagnostic forward model using statistical and calibration uncertainties. These “noisy” data are used in the analysis to evaluate how accurately Z eff is determined. Methods of experimental design are employed to calculate the information gained from different diagnostic combinations. The analysis shows that while attenuation measurements alone do not provide a unique impurity density measurement in the case of a multispecies inhomogeneous plasma, they do provide an effective measurement of the Z eff profile and place constraints on the impurity density profiles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Derivation of Accident-Specific Material-at-Risk Equivalency Factors

A novel method for calculating material at risk (MAR) dose equivalency developed at the Idaho National Laboratory (INL) now allows for increased utilization of dose equivalency for facility MAR control. This method involves near-real time accounting for the use of accident and material specific release and transport. It utilizes all information from the committed effective dose equation and the five factor source term equation to derive dose equivalency factors which can be used to establish an overall facility or process MAR limit. The equivalency factors allow different nuclide spectrums to be compared for their respective dose consequences by relating them to a specific quantity of an identified reference nuclide. The ability to compare spectrums to a reference limit ensures that MAR limits are in fact bounding instead of attempting to establish a representative or bounding spectrum which may lead to unintended or unanalyzed configurations. This methodology is then coupled with a near real time material tracking system which allows for accurate and timely material composition information and corresponding MAR equivalency values. The development of this approach was driven by the complex nature of processing operations in some INL facilities. This type of approach is ideally suited for facilities and processes where the composition of the MAR and possible release mechanisms change frequently but in well defined fashions and in a batch-type nature.

99 GENERAL AND MISCELLANEOUS↗

Constrained or unconstrained? Neural-network-based equation discovery from data

Throughout many fields, practitioners often rely on differential equations to model systems. Yet, for many applications, the theoretical derivation of such equations and/or the accurate resolution of their solutions may be intractable. Instead, recently developed methods, including those based on parameter estimation, operator subset selection, and neural networks, allow for the data-driven discovery of both ordinary and partial differential equations (PDEs), on a spectrum of interpretability. The success of these strategies is often contingent upon the correct identification of representative equations from noisy observations of state variables and, as importantly and intertwined with that, the mathematical strategies utilized to enforce those equations. Specifically, the latter has been commonly addressed via unconstrained optimization strategies. Representing the PDE as a neural network, we propose to discover the PDE (or the associated operator) by solving a constrained optimization problem and using an intermediate state representation similar to a physics-informed neural network (PINN). The objective function of this constrained optimization problem promotes matching the data, while the constraints require that the discovered PDE is satisfied at a number of spatial collocation points. We present a penalty method and a widely used trust-region barrier method to solve this constrained optimization problem, and we compare these methods on numerical examples. Our results on several example problems demonstrate that the latter constrained method outperforms the penalty method, particularly for higher noise levels or fewer collocation points. This work motivates further exploration into using sophisticated constrained optimization methods in scientific machine learning, as opposed to their commonly used, penalty-method or unconstrained counterparts. For both of these methods, we solve these discovered neural network PDEs with classical methods, such as finite difference methods, as opposed to PINNs-type methods relying on automatic differentiation. Here, we briefly highlight how simultaneously fitting the data while discovering the PDE improves the robustness to noise and other small, yet crucial, implementation details.

Data-driven discovery↗

Trapped ultracold bosons in periodically modulated lattices

Motivated by the recent rapid development of the field of quantum gases in optical lattices, we present a comprehensive study of the spectrum of ultracold atoms in a one-dimensional optical lattice subjected to a periodic lattice modulation. Using the time-dependent density matrix renormalization group method, we study the dynamical response due to lattice modulations in different quantum phases of the system with varying density. For the Mott-insulating state, we identify several excitation processes, which provide important information about the density profile of the gases. For the superfluid, the dynamical response can be well described in a local density approximation. This simplification can be valuable in understanding the strong-correlated superfluid in a slow-varying harmonic potential. All these spectroscopic features of an inhomogeneous system can be used as a test for the validity of the Bose-Hubbard model in a parabolic trapping potential.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Excitons and trions in monolayer semiconductors with correlated electrons

We revisit low-temperature optical spectra of transition-metal dichalcogenide monolayers and point to a possible crystallization of electrons (or holes) at low to moderate charge densities. To calculate the excitonic spectra under such conditions, we introduce the recursion method and compute how the charge density affects the energies, linewidths, and oscillator strengths of exciton and trion complexes. Equally important, we study how excitons and trions in the monolayer evolve when the charge particles gradually transition to a periodic Wigner lattice. The results provide valuable information on the ability to detect whether the particles are ordered through the exciton spectrum. Finally, we calculate the change in exciton energy in cases where the added charge particles have similar and dissimilar quantum numbers (spin and valley) to those of the electron or hole in the exciton. Here, the results of this work shed new light on the important optical properties of monolayer semiconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Rapid Development of Instrument Thermal Models: Perspectives and Guidelines from NASA Goddard’s Instrument Design Laboratory

The Instrument Design Laboratory (IDL), part of NASA Goddard Space Flight Center’s Integrated Design Center (IDC), is a concurrent and collaborative environment which allows for rapid development of science instrumentation concepts within the span of less than two weeks. Science goals set by a Principal Investigator from government, industry or academia are translated into engineering requirements, from which a team of engineers spanning multiple disciplines use an established study process and a suite of analysis tools to work towards an instrument point design. As part of this process, a staff thermal engineer is tasked with designing a thermal control system which meets all incoming thermal requirements, while iterating real-time with other subsystems to ensure compatibility and functionality as a completed system. Thermal engineers on spaceflight projects typically have weeks or months to develop thermal models. However, the severe time limitation in this conceptual study setting makes thermal design particularly difficult, as rapid thermal modeling solely over the span of a few days is required to develop the instrument thermal design and understand the performance over its intended mission, especially if the instrument concept contains multiple thermal challenges such as dynamic environments or high heat dissipating components. In this paper, the authors provide a condensed guide for the most efficient ways to develop thermal models and conduct thermal analysis within the span of one-to-two weeks, as informed by decades of design experience and best practices in the IDL. The authors also focus on quick methods for determining worst-case thermal environments, deciding which modeling details are essential at this early phase, and quantifying the engineering resources necessary for thermal control. This paper concludes with specific thermal design tips for different instrument types across the electromagnetic spectrum.

Kan Yang↗

Flux Cube Reconstruction from Slitless Spectroscopy

Slitless spectroscopy enables efficient, large-area surveys without target preselection, yet it faces challenges from source blending, higher noise, and lost spatial–spectral information. We present an advanced, nonparametric, data-driven algorithm that leverages multiple dispersion angles to reconstruct three-dimensional flux distributions, providing low-resolution integral field unit capabilities from slitless data. By treating each pixel as an independent element, our method naturally handles source confusion without requiring prior assumptions regarding redshifts, templates, or model libraries. We validate the algorithm using simulated Roman Space Telescope wide-field slitless spectroscopy images that are equivalent to what is expected from the High-Latitude Time-Domain Survey. First, we demonstrate that a host-galaxy model reconstructed from multiple dispersion angles can be used to accurately subtract host light from a transient, recovering a Type Ia supernova spectrum with minimal bias. Second, we showcase a high-fidelity flux-cube reconstruction of a complex galaxy, successfully measuring the redshift and recovering continuum, emission, and absorption features. This approach highlights the potential of multi-dispersion-angle slitless data to provide spatially resolved spectral information in a nonparametric way, which is traditionally accessible only with integral field spectroscopy, opening a new window into large, unbiased, and spatially resolved studies of galaxy evolution.

Griggio, M. [Space Telescope Science Institute, Ba↗

A full-spectral Bayesian reconstruction approach based on the material decomposition model applied in dual-energy computed tomography

Purpose: Dual-energy computed tomography (DECT) makes it possible to get two fractions of basis materials without segmentation. One is the soft-tissue equivalent water fraction and the other is the hard-matter equivalent bone fraction. Practical DECT measurements are usually obtained with polychromatic x-ray beams. Existing reconstruction approaches based on linear forward models without counting the beam polychromaticity fail to estimate the correct decomposition fractions and result in beam-hardening artifacts (BHA). The existing BHA correction approaches either need to refer to calibration measurements or suffer from the noise amplification caused by the negative-log preprocessing and the ill-conditioned water and bone separation problem. To overcome these problems, statistical DECT reconstruction approaches based on nonlinear forward models counting the beam polychromaticity show great potential for giving accurate fraction images.Methods: This work proposes a full-spectral Bayesian reconstruction approach which allows the reconstruction of high quality fraction images from ordinary polychromatic measurements. This approach is based on a Gaussian noise model with unknown variance assigned directly to the projections without taking negative-log. Referring to Bayesian inferences, the decomposition fractions and observation variance are estimated by using the joint maximum a posteriori (MAP) estimation method. Subject to an adaptive prior model assigned to the variance, the joint estimation problem is then simplified into a single estimation problem. It transforms the joint MAP estimation problem into a minimization problem with a nonquadratic cost function. To solve it, the use of a monotone conjugate gradient algorithm with suboptimal descent steps is proposed.Results: The performance of the proposed approach is analyzed with both simulated and experimental data. The results show that the proposed Bayesian approach is robust to noise and materials. It is also necessary to have the accurate spectrum information about the source-detector system. When dealing with experimental data, the spectrum can be predicted by a Monte Carlo simulator. For the materials between water and bone, less than 5% separation errors are observed on the estimated decomposition fractions.Conclusions: The proposed approach is a statistical reconstruction approach based on a nonlinear forward model counting the full beam polychromaticity and applied directly to the projections without taking negative-log. Compared to the approaches based on linear forward models and the BHA correction approaches, it has advantages in noise robustness and reconstruction accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Holistic fleet optimization incorporating system design considerations

The methodology described in this article enables a type of holistic fleet optimization that simultaneously considers the composition and activity of a fleet through time as well as the design of individual systems within the fleet. Often, real-world system design optimization and fleet-level acquisition optimization are treated separately due to the prohibitive scale and complexity of each problem. Importantly, this means that fleet-level schedules are typically limited to the inclusion of predefined system configurations and are blind to a rich spectrum of system design alternatives. Similarly, system design optimization often considers a system in isolation from the fleet and is blind to numerous, complex portfolio-level considerations. In reality, these two problems are highly interconnected. To properly address this system-fleet design interdependence, we present a general method for efficiently incorporating multi-objective system design trade-off information into a mixed-integer linear programming (MILP) fleet-level optimization. This work is motivated by the authors' experience with large-scale DOD acquisition portfolios. However, the methodology is general to any application where the fleet-level problem is a MILP and there exists at least one system having a design trade space in which two or more design objectives are parameters in the fleet-level MILP.

97 MATHEMATICS AND COMPUTING↗

An adaptive-binning method for generating constant-uncertainty/constant-significance light curves with Fermi -LAT data

Here, we present a method enabling the creation of constant-uncertainty/constant-significance light curves with the data of the Fermi-Large Area Telescope (LAT). The adaptive-binning method enables more information to be encapsulated within the light curve than with the fixed-binning method. Although primarily developed for blazar studies, it can be applied to any sources. Furthermore, this method allows the starting and ending times of each interval to be calculated in a simple and quick way during a first step. The reported mean flux and spectral index (assuming the spectrum is a power-law distribution) in the interval are calculated via the standard LAT analysis during a second step. In the absence of major caveats associated with this method Monte-Carlo simulations have been established. We present the performance of this method in determining duty cycles as well as power-density spectra relative to the traditional fixed-binning method.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-AB-BRB-06: A Temperature Independent Plastic Scintillation Detector Capable of Simultaneous Dose and Temperature Measurement

Purpose: To evaluate a measurement method that renders plastic scintillation detectors temperature independent and capable of recovering dose and temperature information simultaneously. Methods: A novel approach was developed to account for the temperature dependence of plastic scintillation detectors (PSDs) without prior knowledge of the temperature. To enable this, the optical response of the scintillating element is separated into two sub-components, one being the response at a given temperature and the other accounting for the change in the optical emission spectrum with temperature. Using a previously demonstrated hyperspectral approach and following the proper calibration protocol, the contribution to scintillator emission and physical value of both dose and temperature can be obtained in real-time. To validate the method, dose and temperature were measured under cobalt irradiation in a temperature controlled water tank developed for this study. The temperature was varied from 22°C to 42°C. Depth-dose curves were also obtained during irradiations from a linear accelerator, first maintaining the water at room temperature and then warming it to 40°C and letting it cool down naturally over the course of the second measurement. Results: Dose measurements delivered with the Co-60 unit showed an average relative difference to the expected value of (1.0±0.8)%, with a maximum difference of 2.3% over the entire range of temperatures. The measured temperatures using the PSD were all within 1°C of the expected values. The difference between room temperature and warmer depth dose measurements differed by only (1.2±0.4)%. The dosimeter showed to be accurate for temporal resolution down to 0.1s. Conclusion: The proposed method was shown to reliably correct for the temperature dependence of a PSD. Additionally, it makes it possible to assess the temperature at the point of measurement. These are significant advances in PSD technology, particularly in relation to real-time in vivo dosimetry. Part of this research was supported by the Odyssey Program at The University of Texas MD Anderson Cancer Center.

60 APPLIED LIFE SCIENCES↗

Energy-Resolved Neutron Imaging for Reconstruction of Strain Introduced by Cold Working

Energy-resolved neutron transmission imaging is used to reconstruct maps of residual strains in drilled and cold-expanded holes in 5-mm and 6.4-mm-thick aluminum plates. The possibility of measuring the positions of Bragg edges in the transmission spectrum in each 55 × 55 µm2 pixel is utilized in the reconstruction of the strain distribution within the entire imaged area of the sample, all from a single measurement. Although the reconstructed strain is averaged through the sample thickness, this technique reveals strain asymmetries within the sample and thus provides information complementary to other well-established non-destructive testing methods.

Tremsin, Anton (ORCID:0000000324437576)↗

On the Stability of Three-Dimensional Boundary Layers: Secondary Instability - Pt. 2

The secondary instability of three-dimensional incompressible boundary layers is studied using Floquet theory. Starting from the equilibrium solutions that we obtained from the PSE computations documented in Part 1, we investigate the region where a purely stationary crossflow disturbance saturates for its secondary instability characteristics utilizing developed global and local eigenvalue solvers that are based on the Implicitly Restarted Arnoldi Method, and a Newton-Raphson technique, respectively. The main focuses of this study are on the existence of multiple roots in the eigenvalue spectrum that could explain experimental observations of time-dependent occurrences of an explosive growth of traveling disturbances, on the routes by which high-frequency disturbances enter the boundary layer, as well as on gaining more information about threshold amplitudes for the growth of secondary disturbances.

Janke, Erik↗

Improving AIRS Radiance Spectra in High Contrast Scenes Using MODIS

The Atmospheric Infrared Sounder (AIRS) on the EOS Aqua Spacecraft was launched on May 4, 2002. AIRS acquires hyperspectral infrared radiances in 2378 channels ranging in wavelength from 3.7-15.4 microns with spectral resolution of better than 1200, and spatial resolution of 13.5 km with global daily coverage. The AIRS is designed to measure temperature and water vapor profiles for improvement in weather forecast accuracy and improved understanding of climate processes. As with most instruments, the AIRS Point Spread Functions (PSFs) are not the same for all detectors. When viewing a non-uniform scene, this causes a significant radiometric error in some channels that is scene dependent and cannot be removed without knowledge of the underlying scene. The magnitude of the error depends on the combination of non-uniformity of the AIRS spatial response for a given channel and the non-uniformity of the scene, but is typically only noticeable in about 1% of the scenes and about 10% of the channels. The current solution is to avoid those channels when performing geophysical retrievals. In this effort we use data from the Moderate Resolution Imaging Spectroradiometer (MODIS) instrument to provide information on the scene uniformity that is used to correct the AIRS data. For the vast majority of channels and footprints the technique works extremely well when compared to a Principal Component (PC) reconstruction of the AIRS channels. In some cases where the scene has high inhomogeneity in an irregular pattern, and in some channels, the method can actually degrade the spectrum. Most of the degraded channels appear to be slightly affected by random noise introduced in the process, but those with larger degradation may be affected by alignment errors in the AIRS relative to MODIS or uncertainties in the PSF. Despite these errors, the methodology shows the ability to correct AIRS radiances in non-uniform scenes under some of the worst case conditions and improves the ability to match AIRS and MODIS radiances in non-uniform scenes.

spatial↗

Statistical White-Line Analysis in High-Throughput TXM-XANES for Chemical State Quantification

The transmission X-ray microscopy (TXM) based X-ray absorption near-edge structure (XANES) technique provides three-dimensional mapping of element-specific chemical states at nanometer-scale spatial resolution and micrometer-scale fields of view. However, compared to conventional volume-averaged XANES (VA-XANES) measurements, the inherently small voxel size in TXM-XANES leads to a lower signal-to-noise ratio, making full-spectrum analysis computationally demanding and less robust. Here, we present the structural and compositional conditions for a statistical white-line analysis framework under which chemical state information can be directly extracted from the white-line peak position in voxel spectra without the need for voxel-wise background subtraction or normalization, under well-defined structural and compositional conditions. The method is validated on layered oxide cathode materials, where low-order polynomial fitting accurately reproduces white-line features, and the extracted energy distributions correlate strongly with VA-XANES results. This statistical approach enables high-throughput, dose-efficient, and noise-robust chemical state quantification in TXM-XANES, offering broad applicability to functional materials requiring nanoscale oxidation-state mapping.

TXM↗

Investigating the relationship between noise transfer inside the x-ray framing cameras and their imaging ability

We apply a cascaded linear model analysis to a micro-channel plate x-ray framing camera. We establish a theoretical expression of the Noise Power Spectrum (NPS) at the detector’s output and assess its accuracy by comparing it to the NPS of Monte Carlo simulations of the detector’s response to a uniform illumination. We also reflect that fitting the NPS of experimental data against a parametric model based on this expression can yield valuable information on the imaging ability of framing cameras, offering an alternative method to the usual avenue employed to measure their modulation transfer functions.

25 ENERGY STORAGE↗

CT energy weighting in the presence of scatter and limited energy resolution

Purpose: Energy-resolved CT has the potential to improve the contrast-to-noise ratio (CNR) through optimal weighting of photons detected in energy bins. In general, optimal weighting gives higher weight to the lower energy photons that contain the most contrast information. However, low-energy photons are generally most corrupted by scatter and spectrum tailing, an effect caused by the limited energy resolution of the detector. This article first quantifies the effects of spectrum tailing on energy-resolved data, which may also be beneficial for material decomposition applications. Subsequently, the combined effects of energy weighting, spectrum tailing, and scatter are investigated through simulations. Methods: The study first investigated the effects of spectrum tailing on the estimated attenuation coefficients of homogeneous slab objects. Next, the study compared the CNR and artifact performance of images simulated with varying levels of scatter and spectrum tailing effects, and reconstructed with energy integrating, photon-counting, and two optimal linear weighting methods: Projection-based and image-based weighting. Realistic detector energy-response functions were simulated based on a previously proposed model. The energy-response functions represent the probability that a photon incident on the detector at a particular energy will be detected at a different energy. Realistic scatter was simulated with Monte Carlo methods. Results: Spectrum tailing resulted in a negative shift in the estimated attenuation coefficient of slab objects compared to an ideal detector. The magnitude of the shift varied with material composition, increased with material thickness, and decreased with photon energy. Spectrum tailing caused cupping artifacts and CT number inaccuracies in images reconstructed with optimal energy weighting, and did not impact images reconstructed with photon counting weighting. Spectrum tailing did not significantly impact the CNR in reconstructed images. Scatter reduced the CNR for all energy-weighting methods; however, the effect was greater for optimal energy weighting. For example, optimal energy weighting improved the CNR of iodine and water compared to energy-integrating weighting by a factor of {approx}1.45 in the absence of scatter and by a factor of {approx}1.1 in the presence of scatter (8.9 deg. cone angle, SPR 0.5). Without scatter correction, the difference in CNR resulting from photon-counting and optimal energy weighting was negligible (<15%) for cone angles greater than 4.4 deg. (SPR>0.3). Optimal weights combined with deterministic scatter correction provided a 1.3 and 1.1 improvement in CNR compared to energy-integrating and photon-counting weighting, respectively, for the 8.9 deg. cone angle simulation. In the absence of spectrum tailing, image-based weighting demonstrated reduced cupping artifact compared to projection-based weighting; however, both weighting methods exhibited similar cupping artifacts when spectrum tailing was simulated. There were no statistically significant differences in the CNR resulting from projection and image-based weighting for any of the simulated conditions. Conclusions: Optimal linear energy weighting introduces artifacts and CT number inaccuracies due to spectrum tailing. While optimal energy weighting has the potential to improve CNR compared to conventional weighting methods, the benefits are reduced as scatter increases. Efficient methods for reducing scatter and correcting spectrum tailing effects are required to obtain the highest benefit from optimal energy weighting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Physically based correction of systematic errors of Rotating Shadowband Irradiometers

Accurate measurements of direct normal, diffuse horizontal and global horizontal irradiance (DNI, DHI and GHI) are needed for meteorological studies and are essential for the solar resource assessment at potential solar power plant sites. Often, these potential sites are remote and hence require robust sensors that require minimal maintenance that are not affected strongly by soiling. Therefore, Rotating Shadowband Irradiometers (RSI) are widely used for resource assessment. To achieve the required accuracy, corrections for the raw values of RSIs depending on systematic temperature, incidence angle and spectral errors must be used, and a thorough calibration of the sensor head must be applied. The existing correction functions are derived from comparisons of RSIs to thermopile radiometers at selected sites and therefore empirical. Their accuracy is considered to be site dependent. In this work a new correction and calibration method is presented that removes the systematic errors using a physical approach. It is based on information of the sensor properties as well as measurements of its directional response, and incorporates the atmospheric conditions at the measurement site. In this case, no empiric relations obtained from a specific site are required. The method requires estimates of the current DHI and GHI spectra during each measurement of the RSI. Based on these spectra, a spectral correction, which includes a spectrum dependent temperature correction, can be made without employing empirical relationships. The new physical calibration and correction method is tested at three sites and reaches similar results compared to the empirical functions. This is already achieved with rudimentary estimations of the GHI and DHI spectra and we expect that these estimations can be improved in the future. The results indicate that the physical approach reduces the problematic location dependence of the current calibration and correction methods. The physical correction and calibration method show promise for a further improvement of the RSI accuracy.

47 OTHER INSTRUMENTATION↗