Search NASA⌕ Search

SEARCH · Search NASA

Results for “inlets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Design of a very-low-bleed Mach 2.5 mixed-compression inlet with 45 percent internal contraction

A full-scale, mixed-compression inlet was designed for operation with the TF30-P-3 turbofan engine and tested at Mach numbers of 2.5 and 2.0. The two-cone axisymmetric inlet had minimum internal contraction consistent with high total pressure recovery and low cowl drag. At Mach 2.5, inlet recovery was 0.906 with only 0.021 centerbody bleed mass-flow ratio and no cowl bleed. Increased centerbody bleed gave a maximum inlet unstart angle of attack of 6.85 deg. At Mach 2.0, inlet recovery was 0.94 with only 0.014 centerbody bleed mass-flow ratio and no cowl bleed. Inlet performance and angle-of-attack tolerance is presented for operation at Mach numbers of 2.5 and 2.0.

Wasserbauer, J. F.↗

Effect of entry-lip design on aerodynamics and acoustics of high throat Mach number inlets for the quiet, clean, short-haul experimental engine

Results of scale model tests of high-throat-Mach-number inlets designed to suppress inlet-emitted engine machinery noise produced in a V/STOL wind tunnel are presented. A vacuum system was used to induce inlet airflow with a siren as a noise source. Inlet mass flow was 11.68 kilograms (25.75 lb. min) per second at a throat Mach number of 0.79. The effect of entry-lip design (contraction ratio and diameter ratio) on inlet total-pressure recovery, steady-state pressure distortion, performance at high incidence angles, and noise suppression was determined. With proper entry-lip design, total-pressure recovery in excess of 0.988 could be obtained statically at an average throat Mach number of 0.79. Total-pressure distortion was 5 percent. The reduction in the siren tone sound pressure level transmitted through the inlet was 10 to 14 db relative to that measured at throat Mach 0.6.

Miller, B. A.↗

Effects of inlet treatment location and treatment cavity depth on compressor noise

The ability of acoustic liners to reduce compressor noise inside and in front of an inlet was studied. An axial flow research compressor and a specially designed inlet were used inside an anechoic chamber. Acoustic and performance data were obtained for a range of inlet treatment locations and cavity depths to determine their effects on inlet noise over a range of blade passing frequencies. The greatest noise reductions in front of the inlet were obtained with acoustic treatment located close to the compressor and backed with the deepest cavities tested. Inside the inlet the maximum noise level reductions were obtained in the area of the treatment regardless of treatment location. No appreciable losses in compressor performance were measured.

Clark, L. R.↗

Analysis of experimental results of the inlet for the NASA hypersonic research engine aerothermodynamic integration model

An aerodynamic engine inlet analysis was performed on the experimental results obtained at nominal Mach numbers of 5, 6, and 7 from the NASA Hypersonic Research Engine (HRE) Aerothermodynamic Integration Model (AIM). Incorporation on the AIM of the mixed-compression inlet design represented the final phase of an inlet development program of the HRE Project. The purpose of this analysis was to compare the AIM inlet experimental results with theoretical results. Experimental performance was based on measured surface pressures used in a one-dimensional force-momentum theorem. Results of the analysis indicate that surface static-pressure measurements agree reasonably well with theoretical predictions except in the regions where the theory predicts large pressure discontinuities. Experimental and theoretical results both based on the one-dimensional force-momentum theorem yielded inlet performance parameters as functions of Mach number that exhibited reasonable agreement. Previous predictions of inlet unstart that resulted from pressure disturbances created by fuel injection and combustion appeared to be pessimistic.

Andrews, E. H., Jr.↗

Investigation of two bifurcated-duct inlet systems from Mach 0 to 2.0 over a wide range of angles of attack

A 15.354 percent/scale lightweight fighter type inlet/forebody was tested over a Mach number range of 0 to 2.0. Model configurations consisted of side mounted normal shock and fixed overhead ramp type inlets. Each configuration consisted of two inlets ducted (bifurcated) to supply a single engine face. The normal shock inlet variables included a boundary layer splitter bleed system, alternate boundary layer splitter plates, alternate upper and lower cowl lip shapes, and a blow-in-door (auxiliary inlet) in one lower lip. The only variable of the fixed overhead ramp inlet was the boundary layer bleed flow. Reynolds numbers ranged from 7.6 x 1 million to 19.5 x 1 million/m. Angle of attack ranged from -10 to 35 deg and angle of sideslip from -8 to 8 deg. Test measurements included engine face total pressure recovery, steady state distortion, dynamic distortion, and surface static pressures on the forebody and inlet surfaces.

Latham, E. A.↗

Fan inlet disturbances and their effect on static acoustic data

There is evidence that measurements of fan-rotor inlet noise taken during static test situations are at variance with aircraft engine flight data. In particular, static tests generally yield a significantly higher tone at blade passing frequency than that measured during flight. An experimental program was carried out to investigate this discrepancy. Inlet ground vortices and large-scale inlet turbulence were generated intentionally in an anechoic test chamber. Far-field acoustic measurements and inlet flow field hot film mappings of a fan rotor were then carried out to study the influence of such inlet disturbances at a static test facility. Experimental results indicate that the acoustic effect of such disturbances appears to be less severe for supersonic than for subsonic tip speeds. Further, a reverse flow that occurs on the exterior cowl in static test facilities appears to be an additional prime candidate for creating inlet disturbances and causing variance between flight and static acoustic data.

Bekofske, K. L.↗

Atmospheric effects on inlets for supersonic cruise aircraft

Mixed-compression inlet dynamic behavior in the vicinity of unstart, was simulated and analyzed to investigate time response of an inlet's normal shock to independent disturbances in ambient temperature and pressure and relative velocity (longitudinal gust), with and without inlet controls active. The results indicate that atmospheric disturbances may be more important than internal disturbances in setting inlet controls requirements because they are usually not anticipated and because normal shock response to rapid atmospheric disturbances is not attenuated by the inlet, as it is for engine induced disturbances. However, before inlet control requirements can be fully assessed, more statistics on extreme atmospheric disturbances are needed.

Cole, G. L.↗

Phugoid characteristics of a YF-12 airplane with variable-geometry inlets obtained in flight tests at a Mach number of 2.9

Flight tests were conducted with the YF-12 airplane to examine the airplane's longitudinal characteristics at a Mach number of approximately 2.9. Phugoid oscillations as well as short period pulses were analyzed with the variable geometry engine inlets in the fixed and the automatic configurations. Stability and control derivatives for the velocity and altitude degrees of freedom and the standard short period derivatives were obtained. Inlet bypass door position was successfully used to represent the total inlet system, and the effect of the inlets on the velocity and altitude derivatives was determined. The phugoid mode of the basic airplane (fixed inlet configuration) had neutral damping, and the height mode was stable. With the addition of the inlets in the automatic configuration, the phugoid mode was slightly divergent and the height mode was divergent with a time to double amplitude of about 114 seconds. The results of the derivative estimation indicated that the change in the height mode characteristics was primarily the result of the change in the longitudinal force derivative with respect to velocity.

Powers, B. G.↗

Low speed test of a high-bypass-ratio propulsion system with an asymmetric inlet designed for a tilt-nacelle V/STOL airplane

A large scale model of a lift/cruise fan inlet designed for a tilt nacelle V/STOL airplane was tested with a high bypass ratio turbofan. Testing was conducted at low freestream velocities with inlet angles of attack ranging from 0 deg to 120 deg. The operating limits for the nacelle were found to be related to inlet boundary layer separation. Small separations originating in the inlet diffuser cause little or no performance degradation. However, at sufficiently severe freestream conditions the separation changes abruptly to a lip separation. This change is associated with a significant reduction in nacelle net thrust as well as a sharp increase in fan blade vibratory stresses. Consequently, the onset of lip separation is regarded as the nacelle operating limit. The test verified that the asymmetric inlet design will provide high performance and stable operation at the design forward speed and angle of attack conditions. At some of these, however, operation near the lower end of the design inlet airflow range is not feasible due to the occurrence of lip separation.

Syberg, J.↗

Performance of a short annular dump diffuser using suction-stabilized vortices at inlet Mach numbers to 0.41

A short, annular dump diffuser was designed to use suction to establish stabilized vortices on both walls for improved flow expansion in the region of an abrupt area change. The diffuser was tested at near ambient inlet pressure and temperature. The overall diffuser area ratio was 4.0. The inlet height was 2.54 cm and the exit pitot-static rakes were located at a distance from the vortex fence equal to two or six times the inlet height. Performance data were taken at near ambient temperature and pressure for nominal inlet Mach numbers of 0.18 to 0.41 with suction rates of 0 to 18 percent of the total inlet airflow. The exit velocity profile could be shifted toward either wall by adjusting the inner- or outer-wall suction rate. Symmetrical exit velocity profiles were unstable, with a tendency to shift back to hub- or tip-weighted profile. Diffuser effectiveness was increased from about 47 percent without suction to over 85 percent at a total suction rate of about 14 percent. The diffuser total pressure losses at inlet Mach numbers of 0.18 and 0.41 decreased from 1.1 and 5.6 percent without suction to 0.48 and 5.2 percent at total suction rates of 14.4 and 5.6 percent, respectively.

Smith, J. M.↗

Wind tunnel evaluation of YF-12 inlet response to internal airflow disturbances with and without control

The response of terminal-shock position and static pressures in the subsonic duct of a YF-12 aircraft flight-hardware inlet to perturbations in simulated engine corrected airflow were obtained with and without inlet control. Frequency response data, obtained with inlet controls inactive, indicated the general nature of the inherent inlet dynamics, assisted in the design of controls, and provided a baseline reference for responses with active controls. All the control laws were implemented by means of a digital computer that could be programmed to behave like the flight inlet's existing analog control. The experimental controls were designed using an analytical optimization technique. The capabilities of the controls were limited primarily by the actuation hardware. The experimental controls provided somewhat better attenuation of terminal shock excursions than did the YF-13 inlet control. Controls using both the forward and aft bypass systems also provided somewhat better attenuation than those using just the forward bypass. The main advantage of using both bypasses is in the greater control flexibility that is achieved.

Cole, G. L.↗

Free jet phenomena in a 90 deg-sharp edge inlet geometry

The effects of free-jet phenomena, jetting, in a 90-deg-sharp-edge inlet tube are analyzed. Mass-limiting flow data and associated pressure profiles for tubes of 53, 64, 73 and 105 L/D with a 90 deg-sharp-edge or orifice-type inlet are compared to Borda-type inlet data to determine bounds of the free-jet phenomena. For smooth tubes the limits appear to be one-dimensional and dependent only on inlet stagnation conditions. The upper L/D boundary is related by stagnation characteristics and the lower bound appears to be saturation conditions at the inlet. It is noted that similar free-jet effects were found for fluid hydrogen indicating that fluid jetting might be common to all fluids flowing through 90 deg-sharp-edge inlet geometries.

Hendricks, R. C.↗

Effects on inlet technology on cruise speed selection

The impact of cruise speed on technology level for certain aircraft components is examined. External-compression inlets were compared with mixed compression, self starting inlets at cruise Mach numbers of 2.0 and 2.3. Inlet engine combinations that provided the greatest aircraft range were identified. Results show that increased transonic to cruise corrected air flow ratio gives decreased range for missions dominated by supersonic cruise. It is also found important that inlets be designed to minimize spillage drag at subsonic cruise, because of the need for efficient performance for overland operations. The external compression inlet emerged as the probable first choice at Mach 2.0, while the self starting inlet was the probable first choice at Mach 2.3. Airframe propulsion system interference effects were significant, and further study is needed to assess the existing design methods and to develop improvements.

Bangert, L. H.↗

Aerodynamic and acoustic behavior of a YF-12 inlet at static conditions

An aeroacoustic test program to determine the cause of YF-12 inlet noise suppression was performed with a YF-12 aircraft at ground static conditions. Data obtained over a wide range of engine speeds and inlet configurations are reported. Acoustic measurements were made in the far field and aerodynamic and acoustic measurements were made inside the inlet. The J-58 test engine was removed from the aircraft and tested separately with a bellmouth inlet. The far field noise level was significantly lower for the YF-12 inlet than for the bellmouth inlet at engine speeds above 5500 rpm. There was no evidence that noise suppression was caused by flow choking. Multiple pure tones were reduced and the spectral peak near the blade passing frequency disappeared in the region of the spike support struts at engine speeds between 6000 and 6600 rpm.

Bangert, L. H.↗

An implicit method for the calculation of inlet flow fields

Inlet flow fields are calculated by an implicit, time marching procedure to solve the thin layer Navier-Stokes equations formulated in body fitted coordinates. Because the method can be used for a flow field with both subsonic and supersonic regions, it is applicable to subcritical as well as supercritical inlet operation. Results are presented and discussed for an inlet of current design practice. Results include inviscid calculations performed for supercritical inlet operation with uniform and nonuniform inflow boundary conditions as well as for subcritical inlet operation with uniform inflow boundary conditions. Results for viscous calculations performed for supercritical inlet operation with uniform inflow boundary conditions are also discussed.

Biringen, S.↗

A large-scale investigation of engine influence on inlet performance at angle-of-attack

A low-speed wind tunnel test was conducted in the NASA/Ames 40-x-80-foot wind tunnel to investigate the effect of engine/inlet flowfield interaction on inlet performance near flow separation. The effect of engine/inlet flowfield interaction was determined by comparing the performance of a large-scale subsonic inlet (CR = 1.26) close-coupled and remote-coupled to a TF-34 turbofan engine. The remote coupled inlet configuration removes the influence of the engine on the inlet flowfield and further, typifies conventional small-scale inlet test techniques which generally provide no simulation of turbomachinery effects. Test results indicated that engine interaction allows the inlet to operate with lower distortion levels at and beyond the separation angle-of-attack attained without engine interaction.

Hodder, B. K.↗

Aerodynamic performance of a fan stage utilizing Variable Inlet Guide Vanes (VIGVs) for thrust modulation

An experimental research program was conducted in the Lewis Research Center's 9x15-foot (2.74x4.57 m) low speed wind tunnel to evaluate the aerodynamic performance of an inlet and fan system with variable inlet guide vanes (VIGVs) for use on a subsonic V/STOL aircraft. At high VIGV blade angles (lower weight flow and thrust levels), the fan stage was stalled over a major portion of its radius. In spite of the stall, fan blade stresses only exceeded the limits at the most extreme flow conditions. It was found that inlet flow separation does not necessarily lead to poor inlet performance or adverse fan operating conditions. Generally speaking, separated inlet flow did not adversely affect the fan blade stress levels. There were some cases, however, at high VIGV angles and high inlet angles-of-attack where excessive blade stress levels were encountered. An evaluation term made up of the product of the distortion parameter, K alpha, the weight flow and the fan pressure ratio minus one, was found to correlate quite well with the observed blade stress results.

Woollett, R. R.↗

Aerodynamic performance of a fan stage utilizing variable inlet guide vanes (VIGV's) for thrust modulation

An experimental research program was conducted in the Lewis Research Center's 9 x 15-foot (2.74 x 4.57 m) low speed wind tunnel to evaluate the aerodynamic performance of an inlet and fan system with variable inlet guide vanes (VIGVs) for use on a subsonic V/STOL aircraft. At high VIGV blade angles (lower weight flow and thrust levels), the fan stage was stalled over a major portion of its radius. In spite of the stall, fan blade stresses only exceeded the limits at the most extreme flow conditions. It was found that inlet flow separation does not necessarily lead to poor inlet performance or adverse fan operating conditions. Generally speaking, separated inlet flow did not adversely affect the fan blade stress levels. There were some cases, however, at high VIGV angles and high inlet angles-of-attack where excessive blade stress levels were encountered. An evaluation term made up of the product of the distortion parameter, K alpha, the weight flow and the fan pressure ratio minus one, was found to correlate quite well with the observed blade stress results. Previously announced in STAR as N83-27957

Woollett, R. R.↗