Search NASA⌕ Search

SEARCH · Search NASA

Results for “instrument development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

FY2022 Progress Report for Advanced Re-fabrication/Re-instrumentation Capability Development

In support of performing follow-on irradiation experiments with previously irradiated materials, the Halden Reactor Project developed unique and state of the art capabilities to refabricate and re-instrument previously irradiated materials. Such materials were used in in-pile tests at the Halden reactor, and out-of-pile tests for example using furnaces as a heat source. The decision to close the Halden Reactor Project results in the loss of this refabrication and re-instrumentation capability. As a result, the United States (U.S.) Department of Energy (DOE) has determined to develop refabrication and re-instrumentation capability at the unique shielded facilities at Idaho National Laboratory (INL). The development of refabrication capability has been completed and demonstrated. This report focuses on the complementary aspects of reinstrumentation and the progress to-date. Halden spent nearly 30 years developing both refabrication and re-instrumentation. Collaboration with Halden is allowing Idaho National Laboratory (INL) to develop this capability much more rapidly. In FY-21 the results include development of the capability to drill annular center holes in ceramic UO2 fuel pellets, development of fuel rod end caps with feedthroughs for centerline instrumentation inside the rodlet, The procurement of both fuel drilling and welding demonstration equipment from Halden, evaluation of surface thermocouple attachments to support better understanding of temperature measurement uncertainties, and finally, the conceptual design of a new shielded enclosure where advanced refabrication and re-instrumentation equipment can be housed. In FY-22, the results include; Completing set up of the drilling and welding modules procured from Halden, and early experimental trials using that equipment.; Completing set up of an out-of-cell circumferential weld system to allow for further weld development to take place and support fabrication of fuel for fresh fuel experiments.; Evaluation of the Hot Fuel Examination Facility (HFEF) infrastructure to support future installation of advanced re-fabrication/re-instrumentation equipment, specifically related to necessary infrastructure for cryo-drilling.; Developments in dry-drilling alternative. Including experimental studies showing cordierite is the most suitable surrogate for UO 2 for performing drilling studies. That drilling performance is enhanced when a fuel-clad bonding condition is simulated.; Conceptual design completed for attaching surface thermocouples to irradiated fuel in support of TWIST capsule experiments. The authors would like to thank the numerous colleagues at INL and Halden who provided support in accomplishing this work. Their support both material and intellectual is invaluable in advancing the state of the art and establishing the capabilities for refabrication and re-instrumentation at INL.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Power Targetry R&D Roadmap for High Energy Physics

Designing a reliable target is already a challenge for MW-class facilities today and has led several major accelerator facilities to operate at lower power due to target concerns. With present plans to increase beam power for next-generation accelerator facilities in the next decade, timely R&D in support of robust high-power targets is critical to secure the full physics benefits of ambitious accelerator power upgrades. The next generation of high-power targets and beam-intercepting devices (beam dumps, absorbers, collimators ) will have more complex geometries, novel materials, and new concepts that allow for use of improved high-heat-flux cooling methods. Advanced numerical simulations need to be developed to support design of reliable high-power beam targets. In parallel, development of radiation-hardened beam instrumentation is needed. Irradiation methods for high-power targets must be further developed, and new irradiation facilities are needed since only a few facilities worldwide offer beams suitable for target testing. A comprehensive R&D program must be implemented to address the many complex challenges faced by multi-MW beam intercepting devices.

Pellemoine, Frederique [Fermilab]↗

Assessment of Nuclear Sensors and Instrumentation Maturity in Advanced Nuclear Reactors

In the last decade, 97% of the worldwide commercial nuclear reactors connected to the grid were Light Water Reactors (LWRs). LWRs are expected to stay the dominant type of nuclear reactors for the next few decades. Reliable and redundant safety systems are required in nuclear reactors to ensure safe operation and shutdown in abnormal conditions. These safety systems are actuated by the signals obtained from several sensors and instrumentation in and out of the reactor core. Research and Development (R&D) in advanced sensors and instrumentation has gained extra attention, particularly following the accident at the Three Mile Island Unit-2 (TMI-2). In LWRs, these sensors and instrumentation have shown a high level of maturity with long operating experience. Ensuring the compatibility of these sensors and instrumentation with advanced nuclear reactors (Generation IV) is necessary, particularly with the expected expansion of the nuclear industry in the next few decades. Nuclear Sensor and instrumentation technologies used in the current generation of LWRs were investigated. The compatibility of these technologies with advanced reactors was assessed by comparing the advanced reactors' environments with those of the currently operating reactors. In addition to that, the needed R&D for such technologies was highlighted. In comparison with the LWRs environment, it was shown that advanced reactor environments are expected to experience elevated temperatures, a fast neutron spectrum, and a harsh corrosion environment. It was demonstrated that R&D is required mainly for fixed in-core nuclear sensors and instrumentation, while it is not a priority for ex-core nuclear sensors and instrumentation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Plasmonics-Enhanced Optical Imaging Systems for Bioenergy Research

This final report summarizes the key accomplishments of the project entitled “Plasmonics-Enhanced Optical Imaging Systems for Bioenergy Research”. The goal of this project is aimed at developing innovative and improved imaging instrumentation for visualization and quantitative characterization of biomarkers related to molecular processes and cellular function in living plants. This project focused on three specific aims: 1) Development of Advanced Multimodal Optical Sensing And Imaging Combinatory (MOSAIC) System for SERS biosensing and bioimaging. 2) Evaluation of MOSAIC technologies for sensing and imaging gene expression in plant systems using plasmonic nanoprobes. 3) Application of MOSAIC techniques to bioenergy research.

47 OTHER INSTRUMENTATION↗

Laboratory Instrument Software Controlled Spread Spectrum Time Domain Reflectometry for Electrical Cable Testing

This research discusses development of a software-controlled laboratory instrument based spread spectrum time domain reflectometry system (SSTDR). This constitutes one task within PNNL’s Light Water Sustainability Program (LWRS) whose mission includes advancing nondestructive examination (NDE) techniques for off-line and on-line in-situ cable condition monitoring. In 2022, PNNL evaluated SSTDR for detection and characterization of a number of cable anomalies (Glass et al. 2022). The review included comparison of SSTDR to Frequency Domain Reflectometry (FDR) techniques which have enjoyed encouraging feedback and are starting to be used in nuclear power plants for periodic cable condition monitoring of cable systems as part of the plant’s overall cable aging management program. The FDR test introduces a broad-band chirp onto the cable at the cable end then listens for any reflection from a change of impedance along the cable caused by a damaged conductor or insulation, splices, contact with moisture, or other cable anomalies. The signal is captured in the frequency domain then transformed back to the time domain using an inverse Fourier transform (IFT). Based on the velocity of propagation, the impedance response signal is plotted against distance along the cable. Peak locations along the X-axis indicate the distance along the cable where a portion of the signal has been reflected back to the instrument as a result of a cable anomaly. The FDR test is considered the gold standard of reflectometry however it does require the cable to be de-energized to perform the test. The LIVEWIRE commercial SSTDR produces a similar plot to the FDR however all processing is in the time domain. A pseudo-random noise code (PN code) is input onto the cable conductor and the instrument listens for any reflected response from cable anomalies. The SSTDR processes the signal as an autocorrelation comparing the input PN code to any reflected signal detected. The autocorrelation analysis for thermal aging, water and water ingress detection, ground fault and phase-to-phase fault detection at various locations along the cable and with the cable attached and detached from a motor load, and on both energized and un-energized conditions were performed. These results were contrasted to Frequency Domain Reflectometry (FDR) measurements of the un-energized cable. Results were encouraging but indicated more work was warranted – particularly with the SSTDR, it seemed that the insulation damage would likely be better evaluated with multiple bandwidth cable tests particularly including larger bandwidths than were possible with the current commercial instrument. The commercial instrument’s bandwidth was set at 6, 12, 24, and 48MHz but note that SSTDR and FDR definitions of bandwidth trend similarly but are not the same. The FDR response could be more broadly adjusted, and the bandwidth of 100 to 500 MHz produced the best responses. FDR responses to anomalies were clearer than SSTDR responses and indications were that a broader bandwidth SSTDR may lead to improved SSTDR detection capability. This project used a laboratory instrument based SSTDR (primarily using an Arbitrary Waveform Generator (AWG) and a digital oscilloscope plus Python in-house software) that allowed software adjustment of the SSTDR bandwidth, window functions applied to the exciting Pseudo-random Noise (PN) code plus and other aspects of the SSTDR signal processing. Hereafter, this will be referred to as the PNNL SSTDR. Evaluating specific performance of the PNNL SSTDR is left to a separate report. This report documents hardware and software development to produce the SSTDR cable test system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with aspheric x-ray optics

High-accuracy surface metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate x-ray light with nanometer-scale wavelengths. The current and potential capabilities of x˗ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. Metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for fabrication of slightly curved x-ray optics. However, for even moderately curved aspherical x-ray mirrors the flat-reference calibration is not sufficiently accurate. For micro-stitching interferometry developed for surface measurements with curved x-ray mirrors, the tool aberration errors are known to be transferred into the optical surface topography of x-ray mirrors. Our approach to improving metrology is to thoroughly calibrate the measuring tool and apply the results of the calibration to deconvolution of the measured data. Here we explore the application of a recently developed technique for calibrating the instrument transfer function (ITF) of 3D optical surface profilers to metrology with significantly curved x-ray optics. The technique, based on test standards patterned with two-dimensional (2D) binary pseudo-random arrays (BPRAs), employs the unique properties of the BPRA patterns in the spatial frequency domain. The inherent 2D power spectral density of the pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field of view of an instrument. The high efficacy of the technique has been previously demonstrated in application to metrology with flat and slightly curved optics. Here, we concentrate on development of an efficient fabrication process for production of highly randomized (HR) BPRA test standards on flat and 500-mm spherical optical substrates. We also compare and discuss the results of the ITF calibration of an interferometric microscope when using the HR BPRA standards on flat and curved substrates.

Munechika, Keiko↗

An overview of polarized neutron instruments and techniques in Asia Pacific

Polarized neutron scattering is an indispensable tool for exploring a vast range of scientific phenomena. With its dynamic scientific community and significant governmental support as well as the rapid economic growth, the Asia–Pacific region has become a key player in the worldwide neutron scattering arena. From traditional research reactors to cutting-edge spallation neutron sources, this region is home to a myriad of advanced instruments offering a wide range of polarized neutron capabilities. This review aims to provide a comprehensive overview of the development and current status of polarized neutron instruments and techniques in the Asia–Pacific region, emphasizing the important role of the Asia–Pacific region in shaping the landscape of global polarized neutron scattering development.

47 OTHER INSTRUMENTATION↗

Influence of Joule Heating on the Stability of High Temperature Irradiation Resistant Thermocouples

Development of in-core instrumentation is driven by the pursuit of safer and more economic energy production from both existing nuclear reactors and Generation IV reactor designs. Idaho National Laboratory (INL) has developed high temperature irradiation resistant thermocouples (HTIR-TCs) for temperature sensing inside Generation IV nuclear reactors. These thermocouples are composed of phosphorus-doped niobium (Nb-P) and lanthana-doped molybdenum (Mo-LaO) thermoelements, an alumina (Al2O3) insulation, and a niobium sheath. HTIR-TCs require an initial heat treatment exceeding the maximum service temperature to stabilize the generated electromotive force (EMF) signal; however, the mechanism behind this stabilization is not well understood. This work evaluates the impact of Joule heating on the thermoelements' microstructures, chemical stability, and mechanical properties to determine the mechanisms by which the EMF signal stabilization occurs. Accordingly, during the Joule heat treatment, a secondary Nb3P phase coarsened along the length of the Nb-P thermoelement, along with the formation of an interaction region at the Al2O3/niobium interface. The interaction between the alumina insulation and the Nb-P thermoelement was also observed within the Mo-LaO thermoelement. Joule heating induced stability within the generated EMF signal of HTIR-TCs through the formation of secondary phases within the Nb-P and the interaction of the alumina insulation with the thermoelements.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Influence of Joule Heating on the Stability of High Temperature Irradiation-resistant Thermocouples

Development of in-core instrumentation is driven by the pursuit of safer, more economic energy production from the perspective of both existing nuclear reactors and Generation IV reactor designs. Idaho National Laboratory has developed high-temperature irradiation-resistant thermocouples (HTIR-TCs) for temperature sensing inside Generation IV nuclear reactors. These thermocouples are composed of phosphorus-doped niobium (Nb-P) and lanthana-doped molybdenum (Mo-LaO) thermoelements, an alumina (Al2O3) insulation, and a niobium sheath. HTIR-TCs require an initial heat treatment exceeding the maximum service temperature to stabilize the generated electromotive force (EMF) signal. The mechanism behind the stabilization of the HTIR-TCs through traditional heat treatment methods is understood; however, the traditional heat treatment method is expensive, time consuming, and results in a heterogeneous microstructure. Therefore, we investigated a rapid method for stabilization and microstructure homogeneity, through Joule heating. This work evaluates the impact of Joule heating on the thermoelements’ microstructures, chemical stability, and mechanical properties so as to determine the mechanisms by which stabilization of the EMF signal occurs. Accordingly, during the Joule heat treatment, a secondary Nb3P phase coarsened along the length of the Nb-P thermoelement, along with the formation of an interaction region at the Al2O3/niobium interface. The interaction between the alumina insulation and the Nb-P thermoelement was also observed within the Mo-LaO thermoelement. Joule heating induced stability within the generated HTIR-TC EMF signal via the formation of secondary phases within the Nb-P and the interaction between the alumina insulation and the thermoelements.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

The application of flow cytometry for kelp meiospore isolation

The goal of this study was to evaluate flow-cytometric techniques for isolating individual kelp meiospores into 96-welled plates. Previously reported low success rates for sorting tens of thousands of meiospores at a time have been improved by technological developments, specifically, the low nozzle pressure of the commercially available, JSAN (Bay Bioscience Co. Ltd) instrument. We monitored growth and gametophyte development post-sorting for 10 months. Our data demonstrate that successful kelp meiospore isolations of up to 76% viability can be achieved with flow-cytometry. This method can save time as compared to traditional, manual isolations using pipettes and improves confidence that self-fertilized individuals will not contaminate specific crosses of resulting gametophytes. Our results highlight a new application for the flow cytometer to produce clonal kelp gametophytes with direct applications for germplasm and culture collection development.

59 BASIC BIOLOGICAL SCIENCES↗

Technical Challenges and Gaps in Integration of Advanced Sensors, Instrumentation, and Communication Technologies with Digital Twins for Nuclear Application

This paper explores integrating advanced sensor, instrumentation, and communication technologies with digital twin technologies for nuclear energy application. Digital twins and digital-twin-enabling technologies are expected to integrate with future nuclear reactor designs and have the potential to impact currently operating nuclear power plants. Greater digital integration, advanced instrumentation and control systems, and advanced operations and maintenance practices are all associated with digital-twin-enabling technologies. Advanced sensors, instrumentation, and communication technology are expected to comprise important elements of the infrastructure required to develop and operate a nuclear digital twin system. This paper identifies and discusses challenges and gaps in developing and implementing advanced sensors and instrumentation and communication technology to be integrated with a digital twin in current and advanced reactor applications. It is important to address some challenge and gap to enable a successful near-term deploying advanced sensors, instrumentation, and communication technologies integrated with digital twins.

Yadav, Vaibhav↗

Detectors and Instrumentation [Slides]

D&I targets diagnostic maturation and development for subcritical and hydrodynamic experiments 2 to 5 years into the future. Key technology areas include imaging, detectors, instruments and control systems. Most of the work scope is funded from Stockpile Stewardship’s Hydrodynamic and Subcritical Experiment Execution Support (HSEES) portfolio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DARPA beyond CMOS RFI

The Lawrence Livermore National Laboratory Center for Micro and Nanotechnology (CMNT) is located on the LLNL campus in Livermore, CA. LLNL employs over 7000 employees with a broad range of science and engineering backgrounds with an administrative structure that encourages multidisciplinary teaming, a key ingredient in our ability to address diverse technical problems. Our CMNT facility houses a 6,400 ft 2 class 100 cleanroom (class 10 capable) with an additional 1,000 ft 2 Class 1000 space, and 6000 ft 2 of other laboratories. Most equipment can accommodate 6” wafers, although some is limited to 4”. The CMNT is a multi-user, multi-programmatic facility that offers a broad set of instruments for microfabrication to invent, develop, and apply microscale and nanoscale technologies to support national security missions in Stockpile Stewardship, Homeland Security, Directed Energy, Nonproliferation, biomedical research, and more. The research and capabilities of the Center cover materials, devices, instruments, and systems that require microfabricated components, including microelectromechanical systems (MEMS), electronics, photonics, micro- and nanostructures, bio-implantable devices, and micro- and nanoactuators.

42 ENGINEERING↗

A D-term Modeling Code (DMC) for Simultaneous Calibration and Full-Stokes Imaging of Very Long Baseline Interferometric Data

In this paper we present DMC, a model and associated tool for polarimetric imaging of very long baseline interferometry data sets that simultaneously reconstructs the full-Stokes emission structure along with the station-based gain and leakage calibration terms. DMC formulates the imaging problem in terms of posterior exploration, which is achieved using Hamiltonian Monte Carlo sampling. The resulting posterior distribution provides a natural quantification of uncertainty in both the image structure and the data calibration. We run DMC on both synthetic and real data sets, the results of which demonstrate its ability to accurately recover both the image structure and calibration quantities, as well as to assess their corresponding uncertainties. The framework underpinning DMC is flexible, and its specific implementation is under continued development.

47 OTHER INSTRUMENTATION↗

Remote Instrumentation and Data Acquisition

This poster outlines the development and implementation of a remote data acquisition system for waveform analysis using a Rohde & Schwarz oscilloscope. The project involved capturing waveform data, and transferring it to a local machine for visualization and analysis. The core logic was developed in C++ with a focus on object oriented programming and the use of polymorphism so the main application can interact with any instrument without knowing its exact type, simplifying the overall logic and making it easier to add or swap out components without changing the rest of the codebase.. The system issues Standard Commands for Programmable Instruments (SCPI) via a socket connection and parses the oscilloscope s ASCII waveform data. The C++ application was containerized using Docker for ease of portability, and reproducibility. Emphasis was placed on secure networking practices, error handling, and effective data capture. The report describes the technical steps taken, challenges encountered, and future work, providing insight into the practical integration of hardware interfacing with remote computational environments.

Parikh, Jaymil [Illinois U., Urbana]↗

Calibration and Initial Results of Space Radiation Dosimetry Using the iMESA-R

The integrated Miniaturized Electrostatic Analyzer-Reflight (iMESA-R) is a space weather instrument designed to measure plasma density, temperature, and spacecraft charging, along with total ionizing dose and dose rate. A constellation consisting of five nearly identical instruments has been designed and developed to act as science payloads hosted on-board Department of Defense satellites operating in low-Earth orbit. To validate the dosimetry component of the iMESA-R, a radiation test study was performed to calibrate the dosimeter and ascertain the attenuation due to the instrument aluminum housing. An 80 curie Cobalt-60 radioisotope source emitting beta, X-ray, and gamma ray radiation decay products was used to calibrate the dosimeter response as a function of distance and instrument shielding. We present results of the calibration study along with initial on-orbit data presented from the first operational iMESA-R hosted on-board Space Test Program Satellite 5 in a polar Earth orbit. The initial on-orbit data demonstrate the ability to map the radiation environment, particularly the South Atlantic Anomaly and the auroral regions using total ionizing dose rate due to electrons of E > 1.5 MeV and protons of E > 25 MeV.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiation Hardened Beam Instrumentations for Multi-mega-watt Beam Facilities

A beam instrumentation is an essential element for the successful operate particle accelerators in which various diagnostics and beam control systems are integrated into beam optics. However, the performance of beam instrumentation is often subject to constraints such as prompt radiation dose, integrated radiation dose, operation (ambient) temperature and humidity, available space, and strength of embedded electromagnetic fields at the monitoring point. These constraints will limit the dynamic range of operational beam parameters, like the maximum achievable beam power. A seamless R\&D effort to develop the radiation hardened beam instrumentation should be made for future multi-MW beam facilities. In this paper, we describes about a radiation hardened beam instrumentation based on the operational experience of the NuMI beam line.

43 PARTICLE ACCELERATORS↗

Roundtable Report: Terahertz and 6G Wireless Communications in Science and Extreme Environments

The main objective of the roundtable is to bring together computer scientists and wireless communications experts from industry, academia, and government to explore the electromagnetic spectrum in the Terahertz (THz) bands for ultra-high-speed short-distance wireless communications in extreme environments. This new generation of THz wireless communications is the key to future machine-to-machine communications critical for the mass deployment of an intelligent Internet of Things (IoT). The roundtable discussion explores THz and 6G wireless technologies along with Visible Light Communications (VLC), intelligent reflection surfaces, free-space quantum and optical communications, and nano communications. The roundtable considers the suitability of these technologies for extreme environments from the nanoscale to the mesoscale for the following: scientific facilities and associated instruments, as well as industry, and manufacturing. Such use cases are not traditionally the primary customer of commercial wireless networks which are focused on personal broadband voice and data communications. Finally, the discussion identifies high-level opportunities and challenges for leveraging THz and 6G wireless communications and related Artificial Intelligence (AI) that can catalyze the advancement of the development of hyperconnected smart scientific instruments and facilities.

97 MATHEMATICS AND COMPUTING↗