At least 307 records · Page 17

Behind the High Power Targetry R&D at Fermilab

• Recently major accelerator facilities have been limited in beam power not by their accelerators, but by their target facilities – Current high power, high intensity targets in use at Fermilab – Plans for future high power, high intensity target facilities

43 PARTICLE ACCELERATORS↗

Temporal evolution and polarization dependence of relativistic transparency in the ultra-short pulse regime

An ultra-intense laser pulse interacting with a solid target can heat electrons to relativistic energies, driving the plasma to transparency before it expands into the classically underdense regime. This effect, called relativistic transparency (RT), has wide ranging significance across many lines of inquiry in relativistic laser–plasma interactions. Here, we show the temporal evolution of the relativistically induced transparency of a laser heated target as measured by a lower intensity probe beam, providing the first time-resolved measurement of the return to opacity in a target undergoing RT. We also measure a shift in the ellipticity angle of the probe polarization by up to 7.8°. Supporting 3D particle-in-cell simulations corroborate these measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Equivalent equilibrium ion distributions in ion sources and beams

Ion sources and ion beams often contain ions of more than one charge-to-mass ratio, due to the presence of multiple ionization states and/or multiple atomic and molecular ion species in the source. We show that, under certain conditions, analysis of these systems can be simplified using the notion of “equivalent equilibrium ion distributions” (EEIDs). These distributions have identical ion trajectories, space-charge distributions, and electric-field distributions, but can be composed of ion species with arbitrary charge-to-mass ratios. We use this result to obtain multi-species generalizations for the perveance of an ion diode, which relates the diode voltage to the extracted beam current, and for the perveance of a drifting ion beam, which determines the axial length-scale for beam expansion due to the self-electric field. Applied to a quasi-neutral plasma ion source containing cold ions and hot electrons, we find that the location of the beam-plasma interface (meniscus), where ions are extracted from the plasma, depends on the electron density and ion energy per unit charge at the interface, independent of the ion composition. For certain types of numerical simulations, EEIDs allow one to calculate the beam optics of an intense multi-species ion source by doing a simulation for a single ion species with an artificial charge-to-mass ratio chosen to minimize computation time. We illustrate these results using the 3D particle-in-cell, finite-element code Aleph. The simulations show how ions in a plasma source self-consistently accelerate to the supersonic speed needed for steady, radially expanding flow. Multi-species equilibria are subject to streaming instabilities because, while the different species have the same kinetic energy per unit charge, their velocities scale with the square root of the charge-to-mass ratio. The simulations show that a strong ion streaming instability can occur in a multi-species plasma ion source.

74 ATOMIC AND MOLECULAR PHYSICS↗

Conditional guided generative diffusion for particle accelerator beam diagnostics

Abstract Advanced accelerator-based light sources such as free electron lasers (FEL) accelerate highly relativistic electron beams to generate incredibly short (10s of femtoseconds) coherent flashes of light for dynamic imaging, whose brightness exceeds that of traditional synchrotron-based light sources by orders of magnitude. FEL operation requires precise control of the shape and energy of the extremely short electron bunches whose characteristics directly translate into the properties of the produced light. Control of short intense beams is difficult due to beam characteristics drifting with time and complex collective effects such as space charge and coherent synchrotron radiation. Detailed diagnostics of beam properties are therefore essential for precise beam control. Such measurements typically rely on a destructive approach based on a combination of a transverse deflecting resonant cavity followed by a dipole magnet in order to measure a beam’s 2D time vs energy longitudinal phase-space distribution. In this paper, we develop a non-invasive virtual diagnostic of an electron beam’s longitudinal phase space at megapixel resolution (1024 × 1024) based on a generative conditional diffusion model. We demonstrate the model’s generative ability on experimental data from the European X-ray FEL.

43 PARTICLE ACCELERATORS↗

Collimation Systems for the PSR

This note provides a review of collimator systems being used or considered in high-intensity proton accelerators like SNS, J-PARC, LHC, and PIP-II. These facilities use collimators to remove beam halo, restrict transverse size and momentum in the beam to constrain beam losses around collimators and minimize beam losses downstream, particularly losses arising from particles missing the design location at the stripping foil when injected into the proton storage ring. Collimators are placed either in the transport injection lines (single-pass collimators) or in the rings (multi-pass collimators). Collimators in the transport line are placed around stripping foils in H- accelerators, allowing the beamline optics to get rid of the unstripped protons into well localized absorbers. Rings and proton accelerators mostly rely on tungsten scrapers and collimators in a multi-stage configuration to clean the scattered beam particles mainly responsible for heavy losses at high energies. Placement of the collimators is carefully chosen in terms of the right phase advance to maximize the collimating efficiency, whether the collimation is intended to match an injection stripping foil or a downstream acceptance. Collimation systems are designed with the specific concerns of each facility in mind, although all of them prioritize the minimization of activation due to beam losses to enable hands-on access during maintenance periods. At LANSCE, there are no high-energy collimators, although pairs of horizontal and vertical jaws are routinely used in the LEBT to clean and control the transverse beam profile delivered downstream. This report will help in understanding, together with the beam dynamics simulations, which collimation schemes would be most effective for the PSR upgrade. For example, SNS designed off-momentum collimators to be placed in a 90° arc bend, a high-dispersion region in the beam injection line, very similar to the bend at Line D in LANSCE. This system was very effective at minimizing losses during injection into the SNS accumulator ring and is being re-designed for future operation.

43 PARTICLE ACCELERATORS↗

Scattering of a Tightly Focused Beam by an Optically Trapped Particle

Near-forward scattering of an optically trapped 5 m radius polystyrene latex sphere by the trapping beam was examined both theoretically and experimentally. Since the trapping beam is tightly focused, the beam fields superpose and interfere with the scattered fields in the forward hemisphere. The observed light intensity consists of a series of concentric bright and dark fringes centered about the forward scattering direction. Both the number of fringes and their contrast depend on the position of the trapping beam focal waist with respect to the sphere. The fringes are caused by diffraction due to the truncation of the tail of the trapping beam as the beam is transmitted through the sphere.

Lock, James A.↗

Nonintrusive optical single-particle counter for measuring the size and velocity of droplets in a spray

A technique for measuring nonintrusively, and in real time, the size and velocity of droplets in a spray is presented. A small beam identifies the center of a larger beam, thus defining a region of almost uniform intensity, and only droplets crossing through such a center are measured. The size is obtained from the absolute scattered light and the velocity from the modulated signal produced by the interferometric pattern. A self-calibrating algorithm is also discussed. Results are presented for a spray of predictable chracteristics.

Hess, C. F.↗

Installation and Commissioning of the GLUEX DIRC

The GlueX experiment takes place in experimental Hall D at Jefferson Lab (JLab). With a linearly polarized photon beam of up to 12 GeV energy, GlueX is a dedicated experiment to search for hybrid mesons via photoproduction reactions. The low-intensity (Phase I) of GlueX was recently completed; the high-intensity (Phase II) started in 2020 including an upgraded particle identification system, known as the DIRC (Detection of Internally Reflected Cherenkov light), utilizing components from the decommissioned BaBar experiment. The identification and separation of the kaon final states will significantly enhance the GlueX physics program, by adding the capability of accessing the strange quark flavor content of conventional (and potentially hybrid) mesons. Here, we report that the installation and commissioning of the DIRC detector has been successfully completed.

47 OTHER INSTRUMENTATION↗

Transient Relativistic Plasma Grating to Tailor High-Power Laser Fields, Wakefield Plasma Waves, and Electron Injection

In this work, we show the first experiment of a transverse laser interference for electron injection into the laser plasma accelerators. Simulations show such an injection is different from previous methods, as electrons are trapped into later acceleration buckets other than the leading ones. With optimal plasma tapering, the dephasing limit of such unprecedented electron beams could be potentially increased by an order of magnitude. In simulations, the interference drives a relativistic plasma grating, which triggers the splitting of relativistic-intensity laser pulses and wakefield. Consequently, spatially dual electron beams are accelerated, as also confirmed by the experiment.

43 PARTICLE ACCELERATORS↗

Recent Improvements in the Beam Capture at Fermilab Booster for High Intensity Operation

The Fermilab Booster uses multi-turn beam injection with all its cavities phased such that beam sees a net zero RF voltage even when each station is at the same maxi-mum voltage. During beam capture the RF voltage is increased slowly by using its paraphase system. At the end of the capture the feedback is turned on for beam acceleration. It is vital for present operations as well as during the PIP-II era that both the HLRF and LLRF systems provide the proper intended phase and RF voltage to preserve the longitudinal emittance from injection to extraction. In this paper, we describe the original architecture of the cavity phase distribution, our recent beam-based RF phase measurements, observed significant deviation in the relative phases between cavities and correction effort. Results from the improved capture for high intensity beam are also presented.

43 PARTICLE ACCELERATORS↗

Generation of radioisotopes for medical applications using high-repetition, high-intensity lasers

We used the PW high-repetition laser facility VEGA-3 at Centro de Láseres Pulsados in Salamanca, with the goal of studying the generation of radioisotopes using laser-driven proton beams. Various types of targets have been irradiated, including in particular several targets containing boron to generate α-particles through the hydrogen–boron fusion reaction. We have successfully identified γ-ray lines from several radioisotopes created by irradiation using laser-generated α-particles or protons including 43 Sc, 44 Sc, 48 Sc, 7 Be, 11 C and 18 F. We show that radioisotope generation can be used as a diagnostic tool to evaluate α-particle generation in laser-driven proton–boron fusion experiments. We also show the production of 11 C radioisotopes, ≈ 6 × 10 6 , and of 44 Sc radioisotopes, ≈ 5 × 10 4 per laser shot. This result can open the way to develop laser-driven radiation sources of radioisotopes for medical applications.

gamma ray spectroscopy↗

Forward and backward stimulated Raman scattering in multi-speckled beams: Density dependence and effects on cross-beam energy transfer

Particle-in-cell simulations of cross-beam energy transfer (CBET) between multi-speckled beams reveal a potentially prominent energy loss from forward stimulated Raman scattering (FSRS) in the amplified seed beam [Yin et al., Phys. Plasmas 26, 082708 (2019)]. In this work, an intensity scan is used to examine this energy loss in the CBET-amplified seed beam at intensities of a few times 1014 W/cm2. Electron tracers demonstrate both the trapping in the electron plasma waves that is sustained over multiple speckles and the subsequent acceleration to velocities well beyond the phase velocity. Motivated by expanding our understanding of this energy loss mechanism, we isolate the FSRS density dependence by using a 2×1014 W/cm2 pulse to scan densities between 0.06 ncr and 0.12 ncr; a spectral analysis characterizes the energy losses from scattering with the changing densities. At saturation, both greater beam attenuation is measured at the laser frequency and larger scattering FSRS angles are observed as density increases, along with a rapid transition to primarily backscatter SRS between 0.10 ncr and 0.12 ncr, earlier than predicted by linear theory. Density gradients are shown to effectively mitigate oblique FSRS and beam energy losses in the two lower density cases, whereas 0° forward scattering is primarily suppressed in the higher density cases. Finally returning to the two-beam CBET system of interest, the interplay and mitigation of the secondary instabilities at larger domain and beam spatial scales are discussed, here also examining backward stimulated Brillouin scattering.

Stark, D. J. (ORCID:0000000203642733)↗

Free electron lasers for transmission of energy in space

A one-dimensional resonant-particle model of a free electron laser (FEL) is used to calculate laser gain and conversion efficiency of electron energy to photon energy. The optical beam profile for a resonant optical cavity is included in the model as an axial variation of laser intensity. The electron beam profile is matched to the optical beam profile and modeled as an axial variation of current density. Effective energy spread due to beam emittance is included. Accelerators appropriate for a space-based FEL oscillator are reviewed. Constraints on the concentric optical resonator and on systems required for space operation are described. An example is given of a space-based FEL that would produce 1.7 MW of average output power at 0.5 micrometer wavelength with over 50% conversion efficiency of electrical energy to laser energy. It would utilize a 10 m-long amplifier centered in a 200 m-long optical cavity. A 3-amp, 65 meV electrostatic accelerator would provide the electron beam and recover the beam after it passes through the amplifier. Three to five shuttle flights would be needed to place the laser in orbit.

Segall, S. B.↗

Resolution of holograms produced by the fluid experiment system and the holography ground system

The Fluid Experiment System (FES) was developed to study low temperature crystal growth of triglycine sulfate from solution in a low gravity environment onboard Spacelab. The first flight of FES was in 1985. FES uses an optical system to take holograms of the growing crystal to be analyzed after the mission in the Holography Ground System (HGS) located in the Test Laboratory at Marshall Space Flight Center. Microscopic observation of the images formed by the reconstructed holograms is critical to determining crystal growth rate and particle velocity. FES and HGS were designed for a resolution of better than 20 micrometers, but initial observation of the flight holograms show a limit of 80 micrometers. The resolution of the FES holograms is investigated, as well as the role of beam intensity ratio and exposure time on the resolution of HGS produced holograms.

Brooks, Howard L.↗

Initial Time Dependence of Abundances in Solar Energetic Particle Events

We compare the initial behavior of Fe/O and He/H abundance ratios and their relationship to the evolution of the proton energy spectra in "small" and "large" gradual solar energetic particle (SEP) events. The results are qualitatively consistent with the behavior predicted by the theory of Ng et al. (1999a, b). He/H ratios that initially rise with time are a signature of scattering by non-Kolmogorov Alfven wave spectra generated by intense beams of shock-accelerated protons streaming outward in large gradual SEP events.

Reames, Donald V.↗

Reconstruction of Six-Dimensional Phase Space

A phase space is a mathematical representation of all possible physical states of a system. Particle beams at Fermilab exist within a six-dimensional (6D) phase space defined by three positional components, (x, y, z) and three momentum components, (px, py, pz). To reconstruct this space implies taking measurement data from detectors and mapping out particle behavior using computational methods. The beam detectors, however, are only able to detect spatial distribution among the events of the beam, therefore being limited to positional data. Also, due to the vast number of events in a particle beam, it is extremely difficult to analyze and differentiate every single one’s behavior. However, with Machine Learning (ML), which can distinguish between patterns and map out particle behavior more efficiently. We first used the particle beam software, G4beamline, to simulate a 10,000-event muon beam, adjusting parameters such as initial momentum magnitude (p¬0) and virtual detector position. Using ten virtual detectors, we analyzed p0 values such that minimum 9,990 events were analyzed by every detector. We then input the data from these beam simulations to a C++ program, that randomly selects 100 events, and creates a 2D histogram based on spatial distribution, detector position, and event intensity. This process is repeated 100 times to create 100 histograms per p0 value. These images were then input to a modified ResNet18 Convolutional Neural Network (CNN) for training, and to predict p0 from some unseen set of histograms. The model was accurate when trained on momentum increments of 5 MeV/c and provided with denser training samples around highly variable test values. These results displayed machine learning being able to accurately predict p0 from being trained on different particle behaviors.

Shirlee, Jermain [Fermilab]↗

Design and test of a special magnet for the Mu2e experiment

The Mu2e experiment (Muon-to-Electron Conversion Experiment) is looking for evidence that a muon can change into an electron without the emission of neutrinos. The experiment will search for the charged-lepton flavor violating (CLFV) neutrino-less conversion of a negative muon into an electron in the field of a nucleus. The conversion process results in a monochromatic electron with an energy of 104.97 MeV, slightly below the muon rest mass. The goal of the experiment is to improve the previous upper limit by four orders of magnitude and reach a SES (single event sensitivity) of 3 × 10 -17 on the conversion rate, a 90% CL of 8 × 10 -17 , and a 5σ discovery reach at 2 × 10 -16 . The experiment will use an intense pulsed negative muon beam, which is essential to reducing backgrounds. The other essential element is a sophisticated magnetic system composed of three consecutive solenoids (figure 1) that form the muon beam.

43 PARTICLE ACCELERATORS↗

Overview of the New Beam Physics Research at the IOTA/FAST Facility

The Fermilab Accelerator Science and Technology (FAST) facility is dedicated to the exploration of novel concepts in accelerator and beam physics, and the development of a robust workforce, in order to enable and enhance next-generation particle accelerators. FAST comprises a high-brightness superconducting electron linac, and a storage ring, the Integrable Optics Test Accelerator (IOTA). Experiments in the most recent operational run include studies of nonlinear integrable lattices; tracking of single electrons; precise characterization of undulator radiation; studies with low-momentum-compaction lattices; and ultra-wide range beam diagnostics based on Photomultiplier tubes. In the linac, experiments on noise in intense electron bunches were conducted. The IOTA proton injector, currently being commissioned, will enable a diverse program on space-charge-dominated beams. Research areas include non-invasive beam profile monitoring for proton beams; beam dynamics with electron lenses; halo suppression, feedback systems, and electron cooling. In this presentation, we provide an overview of the recent results and highlight future plans together with opportunities for collaboration.