Search NASA⌕ Search

SEARCH · Search NASA

Results for “interferometer calibrations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Note: Digital laser frequency auto-locking for inter-satellite laser ranging

We present a prototype of a laser frequency auto-locking and re-locking control system designed for laser frequency stabilization in inter-satellite laser ranging system. The controller has been implemented on field programmable gate arrays and programmed with LabVIEW software. The controller allows initial frequency calibrating and lock-in of a free-running laser to a Fabry-Pérot cavity. Since it allows automatic recovery from unlocked conditions, benefit derives to automated in-orbit operations. Program design and experimental results are demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Update on the NASA Glenn Propulsion Systems Lab Icing and Ice Crystal Cloud Characterization (2017)

NASA Glenn's Propulsion Systems Lab, an altitude engine test facility, generates icing clouds with a spray system. While the spray system is used mostly to create ice crystal clouds (Appendix D/P), the 2017 cloud characterization effort added the requirement to produce exactly supercooled liquid clouds in Appendix C and Appendix O. Success was demonstrated to supercool the largest drops at the warmest conditions, but not freeze out the smallest drops at the coldest conditions. This paper documents primarily the total water content characterization methodology and results from an Iso-Kinetic Probe in ice crystals and Multi-Wire sensor in supercooled liquid, along with the cloud uniformity provided by light extinction tomography. Particle size distribution results from High Speed Imaging probes and a Phase Doppler Interferometer are discussed. Also, a new numerical model for tracking the thermodynamics of the air-drop interactions in PSL from the plenum toward the cloud characterization plane are noted. Both of these latter topic are more fully documented in companion papers.

Calibration↗

Spectroscopic inferences from HIS measurements of atmospheric thermal emission

Radiometrically accurate observations of the earth's emission spectrum from 3.8 to 16.6 microns have been made using the High-resolution Interferometer Sounder (HIS) to look downward from the NASA U2/ER2 aircraft or upward from the ground. These observations have been used to demonstrate the substantially improved vertical resolution of temperature and water vapor soundings derived from high resolution spectra (resolving power from 1800 to 3800), as compared to soundings from the low resolution filter radiometer observations used in current satellite sounders. The HIS observations have also demonstrated that Fourier Transform Infrared (FTIR) instruments are especially well suited to absolute emission measurements of broad spectral bands at high resolution. A fundamental advantage of FTIR instruments for accurate calibration is wavelength integrity, the same property which has made FTIR the standard for very high resolution absorption measurements. The long wavelength part of a HIS downwelling radiance spectrum is compared to a calculated spectrum. The calculation uses the AFGL HITRAN/86 line file and FASCOD2 line-by-line program with atmospheric state data from in situ measurements. In general, agreement between HIS and FASCOD2 spectra is remarkably good, a tribute to the current state of spectral line files and line-by-line codes. Reproducible differences between HIS observations and FASCOD2 line-by-line calculations lead to the following conclusions: (1) The FASCOD2 water vapor continuum in the longwave window region from 10 to 13 microns (750 to 1000 cm(exp -1)) gives reasonable agreement with radiance observations; (2) The model H2O continuum from 7 to 8 microns (1250 to 1425 cm(exp -2)) needs adjustment to reduce its contribution by about 60 percent; (3) CO2 absorption in the region from 13.1 to 14.3 microns (700 to 760 cm(exp -1)) is too small in the model; and (4) Water vapor line strengths in the region from 8.1 to 9.1 microns (1100 to 1230 cm(exp -1)) need to be increased about 30 percent.

Revercomb, H. E.↗

Experimental Limits on Gravitational Waves in the MHz Frequency Range

This thesis presents the results of a search for gravitational waves in the 1-11MHz frequency range using dual power-recycled Michelson laser interferometers at Fermi National Accelerator Laboratory. An unprecedented level of sensitivity to gravitational waves in this frequency range has been achieved by cross-correlating the output fluctuations of two identical and co-located 40m long interferometers. This technique produces sensitivities better than two orders of magnitude below the quantum shot-noise limit, within integration times of less than 1 hour. 95% confidence level upper limits are placed on the strain amplitude of MHz frequency gravitational waves at the $10^{-21}\ \mathrm{Hz}^{-1/2}$ level, constituting the best direct limits to date at these frequencies. For gravitational wave power distributed over this frequency range, a broadband upper limit of $2.4\times10^{-21}\mathrm{Hz}^{-1/2}$ at 95% confidence level is also obtained. This thesis covers the detector technology, the commissioning and calibration of the instrument, the statistical data analysis, and the gravitational wave limit results. Particular attention is paid to the end-to-end calibration of the instrument's sensitivity to differential arm length motion, and so to gravitational wave strain. A detailed statistical analysis of the data is presented as well.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of Measurements for Solid State Lidar Development

A Detector Characterization Facility (DCF), capable of measuring 2-micron detection devices and evaluating heterodyne receivers, was developed at the Marshall Space Flight Center. The DCF is capable of providing all the necessary detection parameters for design, development, and calibration of coherent and incoherent solid state laser radar (lidar) systems. The coherent lidars in particular require an accurate knowledge of detector heterodyne quantum efficient, nonlinearity properties, and voltage-current relationship as a function of applied optical power. At present, no detector manufacturer provides these qualities or adequately characterizes their detectors for heterodyne detection operation. In addition, the detector characterization facility measures the detectors DC and AC quantum efficiencies noise equivalent power and frequency response up to several GHz. The DCF is also capable of evaluating various heterodyne detection schemes such as balanced detectors and fiber optic interferometers. The design and analyses of measurements for the DCF were preformed over the previous year and a detailed description of its design and capabilities was provided in the NASA report NAS8-38609/DO77. It should also be noted that the DCF design was further improved to allow for the characterization of diffractive andholographical optical elements and other critical components of coherent lidar systems.

Amzajerdian, Farzin↗

Improvement in Rayleigh Scattering Measurement Accuracy

Spectroscopic Rayleigh scattering is an established flow diagnostic that has the ability to provide simultaneous velocity, density, and temperature measurements. The Fabry-Perot interferometer or etalon is a commonly employed instrument for resolving the spectrum of molecular Rayleigh scattered light for the purpose of evaluating these flow properties. This paper investigates the use of an acousto-optic frequency shifting device to improve measurement accuracy in Rayleigh scattering experiments at the NASA Glenn Research Center. The frequency shifting device is used as a means of shifting the incident or reference laser frequency by 1100 MHz to avoid overlap of the Rayleigh and reference signal peaks in the interference pattern used to obtain the velocity, density, and temperature measurements, and also to calibrate the free spectral range of the Fabry-Perot etalon. The measurement accuracy improvement is evaluated by comparison of Rayleigh scattering measurements acquired with and without shifting of the reference signal frequency in a 10 mm diameter subsonic nozzle flow.

Fagan, Amy F.↗

Second Harmonic Generation Electric Field Triplet Interferometry for Absolute Phasing

We report second harmonic generation (SHG) electric field triplet interferometry performed using three mutually coherent ultrafast pulses in a common path with controllable relative phases, namely, the light fields of a sample signal (SI), a reference oscillator (RO), and a local oscillator (LO). The ROLO phase determined from the interference of the light fields produced by two quartz wafers is subtracted from the phase determined from the SIROLO interferogram to yield the signal phase, ϕ SI . The new method also calibrates the measured SHG intensity from a given sample internally by sending the fundamental light field reflected from the sample into one of the quartz wafers in the ROLO element. The approach avoids having to exchange the sample against a reference material with a known χ(2) value or known phase and accounts on-the-fly for situations where the reflected fundamental light field intensity changes with experimental conditions. The new method is successfully benchmarked against z-cut α-quartz, fused silica held at its point of zero charge, and hematite nanolayers in air, across three different interferometers. Furthermore, the approach should be applicable for other second-order nonlinear spectroscopies, such as vibrational or electronic sum-frequency generation.

Interfaces↗

Measuring Extended Structure in Stars Using the Keck Interferometer Nuller

The Keck Interferometer Nuller is designed to detect faint off-axis mid-infrared light a few tens to a few hundreds of milliarcseconds from a bright central star. The starlight is suppressed by destructive combination along the long (85 m) baseline, which produces a fringe spacing of 25 mas at a wavelength of 10 m, with the central null crossing the position of the star. The strong, variable mid-infrared background is subtracted using interferometric phase chopping along the short (5 m) baseline. This paper presents an overview of the observing and data reduction strategies used to produce a calibrated measurement of the off-axis light. During the observations, the instrument cycles rapidly through several calibration and measurement steps, in order to monitor and stabilize the phases of the fringes produced by the various baselines, and to derive the fringe intensity at the constructive peak and destructive null along the long baseline. The data analysis involves removing biases and coherently demodulating the short-baseline fringe with the long-baseline fringe tuned to alternate between constructive and destructive phases, combining the results of many measurements to improve the sensitivity, and estimating the part of the null leakage signal which is associated with the finite angular size of the central star. Comparison of the results of null measurements on science target and calibrator stars permits the instrumental leakage - the "system null leakage" - to be removed and the off-axis light to be measured.

nulling interferometry↗

Testing and Calibration of Phase Plates for JWST Optical Simulator

Three phase plates were designed to simulate the JWST segmented primary mirror wavefront at three on-orbit alignment stages: coarse phasing, intermediate phasing, and fine phasing. The purpose is to verify JWST's on-orbit wavefront sensing capability. Amongst the three stages, coarse alignment is defined to have piston error between adjacent segments being 30 m to 300 m, intermediate being 0.4 m to 10 m, and fine is below 0.4 m. The phase plates were made of fused silica, and were assembled in JWST Optical Simulator (OSIM). The piston difference was realized by the thickness difference of two adjacent segments. The two important parameters to phase plates are piston and wavefront errors. Dispersed Fringe Sensor (DFS) method was used for initial coarse piston evaluation, which is the emphasis of this paper. Point Diffraction Interferometer (PDI) is used for fine piston and wavefront error. In order to remove piston's 2 pi uncertainty with PDI, three laser wavelengths, 640nm, 660nm, and 780nm, are used for the measurement. The DHS test setup, analysis algorithm and results are presented. The phase plate design concept and its application (i.e. verifying the JWST on-orbit alignment algorithm) are described. The layout of JWST OSIM and the function of phase plates in OSIM are also addressed briefly.

Gong, Qian↗

Design Studies for a Far Infrared Absolute Spectrometer for the Cosmic Background Explorer

Unrelenting symmetry of design is required to assure the thermal balance of a cryogenically cooled, rapid scan interferometer spectrometer to be mounted in vacuum with the Cosmic Background Explorer liquid helium dewar. The instrument receives inputs from Winston cone optical flux collectors, one open to space and a second coupled to a black body reference source. A differential instrument, the spectrometer produces outputs corresponding to the Fourier transform of the spectral radiance difference between the two inputs. The two outputs are sensed by four detectors, two optimized for shorter wavelength response, and two optimized for longer wavelengths. The optical design, detector and signal channel, system sensitivity, mechanics, thermal control and cryogenics, electronics and power systems, command and control, calibration, system test requirements, and the instrument interface are discussed. Recommendations for continued work are indicated for the superconducting reflective horns, the motor bearing and drive, and design detail.

Johnson, N. J. E.↗

Study of the performance of antennas in magnetized plasmas

The antenna studies were performed in a large magnetized plasma source, a schematic drawing of which is shown. The plasma diagnostics consist of a 70 GHz (4 mm) microwave interferometer for density measurements and of various Langmuir probes for spatially resolved measurements of t sub e, n sub e and the shape of the electron distribution function. All diagnostic data are time-resolved by sample-and-hold techniques so as to yield information about the plasma build-up, the steady-state discharge, and the plasma decay in the afterglow. Whistler waves are excited and detected with various antennas which are inserted into the center of the plasma column through one axial and two orthogonal radial ports. The antennas were tested for their proper dipole response and then calibrated in a known field geometry in air. For the electric dipole, a parallel plate capacitor field was used; the magnetic loop is calibrated in the near-zone field of a long linear conductor of known radio frequency current distribution. Results are presented and discussed.

Stenzel, R. L.↗

Relative Sensor with 4Pi Coverage for Formation Flying Missions

The Terrestrial Planet Finder (TPF) pre-project, an element of NASA s Origins program, is currently developing two architectures for a mission to search for earth-like planets around nearby stars. One of the architectures being developed is the Formation Flying Interferometer (FFI). The FFI is envisioned to consist of up to seven spacecraft (as many as six "collectors" with IR telescopes, and a "combiner") flying in precise formation within +/-1 cm of pre-determined trajectories for synchronized observations. The spacecraft-to-spacecraft separations are variable between 20 m and 100 m or more during observations to support various configurations of the interferometer in the planet-finding mode. The challenges involved with TPF autonomous operations, ranging from formation acquisition and formation maneuvering to high precision formation control during science observations, are unprecedented. In this paper we discuss the development of the formation acquisition sensor, which uses novel modulation and duplexing schemes to enable fast signal acquisition, multiple-spacecraft operation, and mitigation of inherent jamming conditions, while providing precise formation sensing and integrated radar capability. This approach performs delay synthesis and carrier cycle ambiguity resolution to improve range measurement, and uses differential carrier cycle ambiguity resolution to make precise bearing angle measurements without calibration maneuvers.

Tien, Jeffrey Y.↗

Relative Sensor with 4(pi) Coverage for Formation Flying Missions

The Terrestrial Planet Finder (TPF) pre-project, an element of NASA's Origins program, is currently developing two architectures for a mission to search for earth-like planets around nearby stars. One of the architectures being developed is the Formation Flying Interferometer (FFI). The FFI is envisioned to consist of up to seven spacecraft (as many as six 'collectors' with IR telescopes, and a 'combiner') flying in precise formation within f 1 cm of pre-determined trajectories for synchronized observations. The spacecraft-to-spacecraft separations are variable between 20 m and 100 m or more during observations to support various configurations of the interferometer in the planet-finding mode. The challenges involved with TPF autonomous operations, ranging from formation acquisition and formation maneuvering to high precision formation control during science observations, are unprecedented. In this paper we discuss the development of the formation acquisition sensor, which uses novel modulation and duplexing schemes to enable fast signal acquisition, multiple-spacecraft operation, and mitigation of inherent jamming conditions, while providing precise formation sensing and integrated radar capability. This approach performs delay synthesis and carrier cycle ambiguity resolution to improve range measurement, and uses differential carrier cycle ambiguity resolution to make precise bearing angle measurements without calibration maneuvers.

formation flying sensors↗

Phase-stepping fiber-optic projected fringe system for surface topography measurements

A projected fringe interferometer for measuring the topography of an object is presented. The interferometer periodically steps the phase angle between a pair of light beams emanating from a common source. The steps are pi/2 radians (90 deg) apart, and at each step a video image of the fringes is recorded and stored. Photodetectors measure either the phase and theta of the beams or 2(theta). Either of the measures can be used to control one of the light beams so that the 90 deg theta is accurately maintained. A camera, a computer, a phase controller, and a phase modulator established closed-loop control of theta. Measuring the phase map of a flat surface establishes a calibration reference.

Mercer, Carolyn R.↗

Novel analysis technique for measuring edge density fluctuation profiles with reflectometry in the Large Helical Device

A new method for measuring density fluctuation profiles near the edge of plasmas in the Large Helical Device (LHD) has been developed utilizing reflectometry combined with pellet-induced fast density scans. Reflectometer cutoff location was calculated by proportionally scaling the cutoff location calculated with fast far infrared laser interferometer (FIR) density profiles to match the slower time resolution results of the ray-tracing code LHD-GAUSS. Plasma velocity profile peaks generated with this reflectometer mapping were checked against velocity measurements made with charge exchange spectroscopy (CXS) and were found to agree within experimental uncertainty once diagnostic differences were accounted for. Measured density fluctuation profiles were found to peak strongly near the edge of the plasma, as is the case in most tokamaks. These measurements can be used in the future to inform inversion methods of phase contrast imaging (PCI) measurements. This result was confirmed with both a fixed frequency reflectometer and calibrated data from a multi-frequency comb reflectometer, and this method was applied successfully to a series of discharges. The full width at half maximum of the turbulence layer near the edge of the plasma was found to be only 1.5–3 cm on a series of LHD discharges, less than 5% of the normalized minor radius.

47 OTHER INSTRUMENTATION↗

Experiments D004 and D007: Celestial radiometry and space object radiometry

Two interferometer spectrometers and a multichannel spectroradiometer were used as sensing instruments during the Gemini 5 and 7 missions. The selection of the instruments and of the particular detectors in the instruments was based upon the spectral bands to be investigated in each flight and upon the nature of the intended measurements. The instrument characteristics were a compromise among optimization for a particular type of measurement, a need for a broad selection of spectral information, and performance and other pertinent characteristics of the spacecraft. Data were collected on earth background, sky background, rocket exhaust plumes, celestial bodies, man made objects in space, weather phenomena, and spectral calibrations.

Lovett, J.↗

ORION S-band data acquisition for S-Y calibration

Error sources in the Operational Radio Interferometry Observing Network (ORION) are addressed. Specifically, the performance of the S-band receiver and the optimum allocation of data volume between S- and X-band observations is studied. It is found that the requirements on the S-band receiver are not very stringent. The system temperature of the ORION S-band receiver has a very small effect on baseline determination accuracy. It is unwise to pay a high cost for an S-band receiver with a low system temperature; a system temperature as high as 240 K is tolerable. Only 20 to 40 percent of data volume is to be allocated to S-band observations for minimum baseline error. The error remains low over a rather wide range of data volume ratio. Hence precise allocation of the 14 pairs of the Mark 3 very long base interferometer data channels between S- and X-band observations is not critical.

Wu, S. C.↗

Parasitic Interference in Nulling Interferometry

Nulling interferometry aims to detect faint objects close to bright stars. Its principle is to produce a destructive interference along the line of sight so that the stellar flux is rejected, while the flux of the off-axis source can be transmitted. In practice, various instrumental perturbations can degrade the nulling performance. Any imperfection in phase, amplitude or polarization produces a spurious flux that leaks to the interferometer output and corrupts the transmitted off-axis flux. One of these instrumental perturbations is the crosstalk phenomenon, which occurs because of multiple parasitic reflections inside transmitting optics, and/or diffraction effects related to beam propagation along finite size optics. It can include a crosstalk of a beam with itself, and a mutual crosstalk between different beams. This can create a parasitic interference pattern, which degrades the intrinsic transmission map - or intensity response - of the interferometer. In this context, we describe how this instrumental effect impairs the performance of a Bracewell interferometer. A simple formalism is developed to derive the corresponding modified intensity response of the interferometer, as a function of the two parameters of interest: the crosstalk level (or contamination rate) and the phase shift between the primary and secondary - parasitic - beams. We then apply our mathematical approach to a few scientific cases, both analytically and using the GENIESIM simulation software, adapted to handle coherent crosstalk. Our results show that a coherent crosstalk level of about 1 per cent implies a 20 per cent drop of the signal-to-noise ratio at most. Careful attention should thus be paid to reduce the crosstalk level inside an interferometric instrument and ensure an instrumental stability that provides the necessary sensitivity through calibration procedures.

circumstellar matter↗