Search NASA⌕ Search

SEARCH · Search NASA

Results for “interval analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Motexafin Gadolinium Combined With Prompt Whole Brain Radiotherapy Prolongs Time to Neurologic Progression in Non-Small-Cell Lung Cancer Patients With Brain Metastases: Results of a Phase III Trial

Purpose: To determine the efficacy of motexafin gadolinium (MGd) in combination with whole brain radiotherapy (WBRT) for the treatment of brain metastases from non-small-cell lung cancer. Methods and Materials: In an international, randomized, Phase III study, patients with brain metastases from non-small-cell lung cancer were randomized to WBRT with or without MGd. The primary endpoint was the interval to neurologic progression, determined by a centralized Events Review Committee who was unaware of the treatment the patients had received. Results: Of 554 patients, 275 were randomized to WBRT and 279 to WBRT+MGd. Treatment with MGd was well tolerated, and 92% of the intended doses were administered. The most common MGd-related Grade 3+ adverse events included liver function abnormalities (5.5%), asthenia (4.0%), and hypertension (4%). MGd improved the interval to neurologic progression compared with WBRT alone (15 vs. 10 months; p = 0.12, hazard ratio [HR] = 0.78) and the interval to neurocognitive progression (p = 0.057, HR = 0.78). The WBRT patients required more salvage brain surgery or radiosurgery than did the WBRT+MGd patients (54 vs. 25 salvage procedures, p < 0.001). A statistically significant interaction between the geographic region and MGd treatment effect (which was in the prespecified analysis plan) and between treatment delay and MGd treatment effect was found. In North American patients, where treatment was more prompt, a statistically significant prolongation of the interval to neurologic progression, from 8.8 months for WBRT to 24.2 months for WBRT+MGd (p = 0.004, HR = 0.53), and the interval to neurocognitive progression (p = 0.06, HR = 0.73) were observed. Conclusion: In the intent-to-treat analysis, MGd exhibited a favorable trend in neurologic outcomes. MGd significantly prolonged the interval to neurologic progression in non-small-cell lung cancer patients with brain metastases receiving prompt WBRT. The toxicity was acceptable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modern Outcomes of Inflammatory Breast Cancer

Purpose: To report contemporary outcomes for inflammatory breast cancer (IBC) patients treated in the modern era of trastuzumab and taxane-based chemotherapy. Methods and Materials: We retrospectively reviewed the charts of 104 patients with nonmetastatic IBC treated between January 2000 and December 2009. Patients who received chemotherapy, surgery, and radiation therapy were considered to have completed the intended therapy. Kaplan-Meier curves estimated locoregional control (LRC), distant metastases-free survival (DMFS), and overall survival. Results: The median follow-up time was 34 months; 57 (55%) patients were estrogen receptor progesterone receptor (ER/PR) negative, 34 (33%) patients were human epidermal growth factor receptor 2 (her2)/neu amplified, and 78 (75%) received definitive postoperative radiation. Seventy-five (72%) patients completed all of the intended therapy, of whom 67 (89%) received a taxane and 18/28 (64%) of her2/neu-amplified patients received trastuzumab. For the entire cohort, the 5-year rates of overall survival, LRC, and DMFS were 46%, 83%, and 44%, respectively. The ER/PR-negative patients had a 5-year DMFS of 39% vs. 52% for ER/PR-positive patients (p = 0.03). The 5-year DMFS for patients who achieved a pathologic complete response compared with those who did not was 83% vs. 44% (p < 0.01). Those patients who received >60.4 Gy (n = 15) to the chest wall had a 5-year LRC rate of 100% vs. 83% for those who received 45 to 60.4 Gy (n = 49; p = 0.048). On univariate analysis, significant predictors of DMFS included achieving a complete response to neoadjuvant chemotherapy (hazard ratio [HR] = 5.8; 95% confidence interval [CI] = 1.4-24.4; p = 0.02) and pathologically negative lymph nodes (HR = 4.1; 95% CI = 1.4-11.9; p < 0.01), but no factor was significant on multivariate analysis. Conclusions: For IBC patients, the rate of distant metastases is still high despite excellent local control, particularly for patients who received >60.4 Gy to the chest wall. Despite the use of taxanes and trastuzumab, outcomes remain modest, particularly for those with ER/PR-negative disease and those without a pathologic complete response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Carbon emission responsive building control: A case study with an all-electric residential community in a cold climate

In the United States, buildings account for 35% of total energy-related carbon dioxide emissions, making them important contributors to decarbonization. Carbon intensities in the power grid are time-varying and can fluctuate significantly within hours, so shifting building loads in response to the carbon intensities can reduce a building’s operational carbon emissions. This paper presents a rule-based carbon responsive control framework that controls the setpoints of thermostatically controlled loads responding to the grid’s carbon emission signals in real time. Based on this framework, four controllers are proposed with different combinations of carbon accounting methods and control rules. To evaluate their performance, we performed simulation studies using models of a 27-home, all-electric, net zero energy residential community located in Basalt, Colorado, United States. The carbon intensity data of four future years from the Cambium data set are adopted to account for the evolving resource mix in the power grid. Various performance metrics, including energy consumption, carbon emission, energy cost, and thermal discomfort, were used to evaluate the performance of the controllers. Sensitivity analysis was also conducted to determine how the control thresholds and intervals affect the controllers’ performance. Simulation results indicate that the carbon responsive controllers can reduce the homes’ annual carbon emissions by 6.0% to 20.5%. However, the energy consumption increased by 0.9% to 6.7%, except in one scenario where it decreased by 2.2%. Compared to the baseline, the change in energy cost was between –2.9% and 3.4%, and thermal discomfort was also maintained within an acceptable range. The little impact on energy cost and thermal discomfort indicates there are no potential roadblocks for customer acceptance when rolling out the controllers in utility programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Behavioural phenotypes in mice after prenatal and early postnatal exposure to intermediate frequency magnetic fields

Highlights: • Human exposure to intermediate frequency magnetic fields (MF) is increasing. • We exposed prenatal and early postnatal male mice to 7.5 kHz MFs at 12 and 120 μT. • A behavioural teratology study focused on the developing nervous system. • No consistent adverse effects were observed. Electromagnetic fields are ubiquitous in the environment. Human exposure to intermediate frequency (IF) fields is increasing due to applications like electronic article surveillance systems, wireless power transfer, and induction heating cooking hobs. However, there are limited data on possible health effects of exposure to IF magnetic fields (MF). In the present study, we set out to assess cognitive and behavioural effects of IF MF in mice exposed during prenatal and early postnatal periods. Pregnant female mice were exposed continuously to 7.5 kHz MFs at 12 and 120 μT, from mating until weaning of pups. Sham exposed pregnant mice were used as a control group. A behavioural teratology study was conducted on the male offspring at two months of age to detect possible effects on the developing nervous system. Body weight development did not differ between the exposure groups. The exposure did not alter spontaneous motor activity when exploring a novel cage or anxiety in novelty-suppressed feeding or marble burying tests. Improved performance in the Rotarod task was observed in the 12 µT group, while the 120 μT exposure group swam more slowly than the sham exposed group in the Morris swim navigation task. However, indices of learning and memory (path length and escape latency during task acquisition and search bias during the probe test) did not differ between the exposure groups. Furthermore, the passive avoidance task did not indicate any impairment of long-term memory over a 48 h interval in the exposed groups. In a post-mortem histopathological analysis, there was no evidence for an effect of IF MF exposure on astroglial reactivity or hippocampal neurogenesis. The results suggest that the IF MF used did not have detrimental effects on spatial learning and memory or histological markers of tissue reaction. The two statistically significant findings that were observed (improved performance in the Rotarod task in the 12 µT group and decreased swimming speed in the 120 µT group) are likely to be chance findings, as they do not form an internally consistent, dose-dependent pattern indicative of specific developmental effects.

54 ENVIRONMENTAL SCIENCES↗

Reduction of Overall Treatment Time in Patients Irradiated for More Than Three Brain Metastases

Purpose: Patients with multiple brain metastases usually receive whole brain radiotherapy (WBRT). A dose of 30 Gy in 10 fractions (10 x 3 Gy) in 2 weeks is the standard treatment in many centers. Regarding the poor survival of these patients, a shorter RT regimen would be preferable if it provides a similar outcome as that with 10 x 3 Gy. This study compared 20 Gy in five fractions (5 x 4 Gy) within 5 days to 10 x 3 Gy. Methods and Materials: Data from 442 patients treated with WBRT for multiple brain metastases were retrospectively analyzed. Survival and local control within the brain of 232 patients treated with 5 x 4 Gy were compared with the survival and local control within the brain of 210 patients treated with 10 x 3 Gy. Seven additional potential prognostic factors were investigated: age, gender, Karnofsky performance score, tumor type, interval from tumor diagnosis to RT, extracranial metastases, and recursive partitioning analysis class. Results: On univariate analysis, the WBRT program was not associated with survival (p = 0.29) or local control (p = 0.07). On multivariate analyses, improved survival was associated with a lower recursive partitioning analysis class (p < 0.001), age {<=}60 years (p = 0.001), Karnofsky performance score {>=}70 (p = 0.015), and the absence of extracranial metastases (p = 0.005). Improved local control was associated with a lower recursive partitioning analysis class (p < 0.001), Karnofsky performance score {>=}70 (p < 0.001), and breast cancer (p = 0.043). Grade 3 acute toxicity rates were not significantly different between 5 x 4 Gy and 10 x 3 Gy. Conclusions: Shorter course WBRT with 5 x 4 Gy was associated with similar survival and local control as 'standard' WBRT with 10 x 3 Gy in patients with more than three brain metastases. The 5 x 4-Gy regimen appears preferable for most of these patients, because it is less time consuming and more convenient for patients than the 10 x 3-Gy regimen.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prognosis for Mammographically Occult, Early-Stage Breast Cancer Patients Treated With Breast-Conservation Therapy

Purpose: To compare mammographically occult (MamOcc) and mammographically positive (MamPos) early-stage breast cancer patients treated with breast-conservation therapy (BCT), to analyze differences between the two cohorts. Methods and Materials: Our two cohorts consisted of 214 MamOcc and 2168 MamPos patients treated with BCT. Chart reviews were conducted to assess mammogram reports and method of detection. All clinical-pathologic and outcome parameters were analyzed to detect differences between the two cohorts. Results: Median follow-up was 7 years. There were no differences in final margins, T stage, nodal status, estrogen/progesterone receptor status, or 'triple-negative' status. Significant differences included younger age at diagnosis (p < 0.0001), more positive family history (p = 0.0033), less HER-2+ disease (p = 0.0294), and 1{sup o} histology (p < 0.0001). At 10 years, the differences in overall survival, cause-specific survival, and distant relapse between the two groups did not differ significantly. The MamOcc cohort had more breast relapses (15% vs. 8%; p = 0.0357), but on multivariate analysis this difference was not significant (hazard ratio 1.0, 95% confidence interval 0.993-1.007, p = 0.9296). Breast relapses were mammographically occult in 32% of the MamOcc and 12% of the MamPos cohorts (p = 0.0136). Conclusions: Although our study suggests that there are clinical-pathologic variations for the MamOcc cohort vs. MamPos patients that may ultimately affect management, breast relapse after BCT was not significantly different. Breast recurrences were more often mammographically occult in the MamOcc cohort; consideration should be given to closer follow-up and alternative imaging strategies (ultrasound, breast MRI) for routine posttreatment examination. To our knowledge, this represents the largest series addressing the prognostic significance of MamOcc cancers treated with BCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Do Patients Receiving Whole-Brain Radiotherapy for Brain Metastases From Renal Cell Carcinoma Benefit From Escalation of the Radiation Dose?

Purpose: Whole-brain radiotherapy (WBRT) is the most common treatment for brain metastases from renal cell carcinoma (RCC). Most patients cannot receive more aggressive therapies including surgery or radiosurgery. The standard WBRT regimen, 30 Gy/10 fractions (10 x 3 Gy), has resulted in poor survival (OS). This study investigates whether escalation of the WBRT dose improves treatment outcomes. Methods and Materials: Data from 60 patients receiving WBRT for brain metastases from RCC were retrospectively analyzed. A dose of 10 x 3 Gy (n = 31) was compared with higher doses (40 Gy/20 fractions or 45 Gy/15 fractions; n = 29) for OS and local control (LC). Additional factors evaluated were patient age, sex, performance status, number of metastases, interval from diagnosis of RCC to WBRT, extracerebral metastases, recursive partitioning analysis (RPA) class, and year of WBRT. Results: The OS at 6 months was 29% after 10 x 3 Gy and 52% after higher doses (p = 0.003). The OS at 12 months was 13% and 47%, respectively. On multivariate analysis, higher WBRT doses (p = 0.022), Karnofsky performance status score {>=}70 (p = 0.017), fewer than four brain metastases (p = 0.035), and RPA Class 1 (p = 0.003) resulted in better OS. The LC at 6 months was 21% after 10 x 3 Gy and 57% after higher doses (p = 0.013). The LC at 12 months was 7% and 35%, respectively. On multivariate analysis, fewer than four brain metastases (p < 0.001) were associated with LC. A trend was found for WBRT regimen (p = 0.06) and RPA class (p = 0.06). Conclusions: The findings suggest that escalation of the WBRT dose beyond 10 x 3 Gy improves outcomes in patients with brain metastases from RCC. The results should be confirmed in a randomized trial stratifying for significant prognostic factors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Shorter-Course Whole-Brain Radiotherapy for Brain Metastases in Elderly Patients

Purpose: Many patients with brain metastases receive whole-brain radiotherapy (WBRT) alone. Using 10 Multiplication-Sign 3 Gy in 2 weeks is the standard regimen in most centers. Regarding the extraordinarily poor survival prognosis of elderly patients with multiple brain metastases, a shorter WBRT regimen would be preferable. This study compared 10 Multiplication-Sign 3 Gy with 5 Multiplication-Sign 4 Gy in elderly patients ({>=}65 years). Methods and Materials: Data from 455 elderly patients who received WBRT alone for brain metastases were retrospectively analyzed. Survival and local (= intracerebral) control of 293 patients receiving 10 Multiplication-Sign 3 Gy were compared with 162 patients receiving 5 Multiplication-Sign 4 Gy. Eight additional potential prognostic factors were investigated including age, gender, Karnofsky performance score (KPS), primary tumor, number of brain metastases, interval from tumor diagnosis to WBRT, extracerebral metastases, and recursive partitioning analysis (RPA) class. Results: The 6-month overall survival rates were 29% after 5 Multiplication-Sign 4 Gy and 21% after 10 Multiplication-Sign 3 Gy (p = 0.020). The 6-month local control rates were 12% and 10%, respectively (p = 0.32). On multivariate analysis, improved overall survival was associated with KPS {>=} 70 (p < 0.001), only one to three brain metastases (p = 0.029), no extracerebral metastasis (p = 0.012), and lower RPA class (p < 0.001). Improved local control was associated with KPS {>=} 70 (p < 0.001), breast cancer (p = 0.029), and lower RPA class (p < 0.001). Conclusions: Shorter-course WBRT with 5 Multiplication-Sign 4 Gy was not inferior to 10 Multiplication-Sign 3 Gy with respect to overall survival or local control in elderly patients. 5 Multiplication-Sign 4 Gy appears preferable for the majority of these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of the Radiation-Equivalent of Chemotherapy Contributions in 1-Phase Radio-chemotherapy Treatment of Muscle-Invasive Bladder Cancer

Purpose: To estimate the radiation equivalent of the chemotherapy contribution to observed complete response rates in published results of 1-phase radio-chemotherapy of muscle-invasive bladder cancer. Methods and Materials: A standard logistic dose–response curve was fitted to data from radiation therapy-alone trials and then used as the platform from which to quantify the chemotherapy contribution in 1-phase radio-chemotherapy trials. Two possible mechanisms of chemotherapy effect were assumed (1) a fixed radiation-independent contribution to local control; or (2) a fixed degree of chemotherapy-induced radiosensitization. A combination of both mechanisms was also considered. Results: The respective best-fit values of the independent chemotherapy-induced complete response (CCR) and radiosensitization (s) coefficients were 0.40 (95% confidence interval −0.07 to 0.87) and 1.30 (95% confidence interval 0.86-1.70). Independent chemotherapy effect was slightly favored by the analysis, and the derived CCR value was consistent with reports of pathologic complete response rates seen in neoadjuvant chemotherapy-alone treatments of muscle-invasive bladder cancer. The radiation equivalent of the CCR was 36.3 Gy. Conclusion: Although the data points in the analyzed radio-chemotherapy studies are widely dispersed (largely on account of the diverse range of chemotherapy schedules used), it is nonetheless possible to fit plausible-looking response curves. The methodology used here is based on a standard technique for analyzing dose-response in radiation therapy-alone studies and is capable of application to other mixed-modality treatment combinations involving radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spectral Properties of Type Ia Supernovae up to $z\sim 0.3$

Aims: Spectroscopic observations of Type Ia supernovae obtained at the New Technology Telescope (NTT) and the Nordic Optical Telescope (NOT), in conjunction with the SDSS-II Supernova Survey, are analysed. We use spectral indicators measured up to a month after the lightcurve peak luminosity to characterise the supernova properties, and examine these for potential correlations with host galaxy type, lightcurve shape, colour excess, and redshift. Methods: Our analysis is based on 89 Type Ia supernovae at a redshift interval z = 0.05 - 0.3, for which multiband SDSS photometry is available. A lower-z spectroscopy reference sample was used for comparisons over cosmic time. We present measurements of time series of pseudo equivalent widths and line velocities of the main spectral features in Type Ia supernovae. Results: Supernovae with shallower features are found predominantly among the intrinsically brighter slow declining supernovae. We detect the strongest correlation between lightcurve stretch and the Si ii 4000 absorption feature, which also correlates with the estimated mass and star formation rate of the host galaxy. We also report a tentative correlation between colour excess and spectral properties. If confirmed, this would suggest that moderate reddening of Type Ia supernovae is dominated by effects in the explosion or its immediate environment, as opposed to extinction by interstellar dust.

79 ASTRONOMY AND ASTROPHYSICS↗

Reviving sub-keV warm dark matter: a UVLF-based analysis

Thermal warm dark matter (WDM) particles with m WDM ≤ 1 keV are ruled out at more than 4σ by multiple observational probes, owing to the strong suppression of small-scale structure induced by early-time free-streaming. Recently, it was highlighted that a small admixture of ∼ 1% (f CDM ∼ 0.01) cold dark matter (CDM) endowed with a blue-tilted isocurvature spectrum could offset the WDM-induced suppression and relax the WDM mass bound by a factor of 𝒪(10). If viable, this “warm + cold-isocurvature” scenario would allow sub-keV WDM particles to constitute nearly the full dark matter abundance while potentially alleviating some small-scale tensions. In this work, we test this mechanism by constraining the WDM mass mWDM while marginalizing over CDM isocurvature parameters. We combine ultraviolet luminosity function measurements from the Hubble Space Telescope and James Webb Space Telescope over redshift 4 ≤ z ≤ 11 with CMB, BAO, and SNe data. For a pure WDM model, our joint analysis yields a lower bound m WDM > 1.8 keV (95% credible intervals). When CDM isocurvature is introduced at f CDM = 0.01, the limit relaxes to m WDM > 0.27 keV (95% credible intervals), reflecting a shallow degeneracy in which blue-tilted isocurvature fluctuations partially compensate for WDM suppression. These results provide new constraints on thermal WDM in the presence of CDM isocurvature fluctuations and quantify the extent to which such fluctuations can mask the small-scale signatures of light relics.

cosmological parameters from CMBR↗

Energy dependence of $\textit{p}$ + 232 Th fission mass distributions: Mass-asymmetric standard I and standard II modes, and multichance fission

Background: The predominant mass-asymmetric fission of actinide nuclides occurs mainly through the so-called standard I and standard II modes. Though understood to be caused by shape-dependent shell structures encountered between the fission barrier deformation and scission, the most relevant shell gaps are still not firmly established. The standard I mode had been associated with the spherical doubly magic 132 Sn, and thus the $\textit{Z}$ = 50 proton shell, but recently it has been proposed that standard I and standard II are associated with quadrupole and octupole deformed gaps at $\textit{Z}$ = 52 and 56, respectively. Purpose: In this work, we investigate how the relative probabilities of the standard I and standard II modes vary with excitation energy near threshold, probing where the two modes bifurcate. Methods: The Australian National University Heavy Ion Accelerator Facility and CUBE fission spectrometer have been used to measure fission mass distributions for the $\textit{p}$ + 232 Th reaction (forming 233 Pa) at closely spaced bombarding energy intervals from 6.5 to 28 MeV. Results: A model-independent analysis of the energy dependence of the shape of the mass-asymmetric peak shows a strong dependence of the standard I and standard II relative probability on excitation energy near threshold. Conclusions: The results are consistent with the standard II mode having a lower fission barrier than standard I in 233 Pa, with the latter increasing continually in relative probability above its barrier energy. It is concluded that multichance fission, in particular last chance fission, plays a strong role in determining the observed energy dependence of all fission modes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Milestone report - M4FT-14OR03120217 - Initiate very low iodine concentration adsorption tests

The objective of this effort was to design and install a system to allow the testing of sorbent materials under simulated vessel off-gas (VOG) conditions. The test system consisted of a gas supply system that allows the mixing of dry air, humidified air, and low levels of iodine. The iodine is supplied by a KIN-TEK Flexstream Gas Standards Generator. The sorbents are placed in three separate glass sorbent housings. The first housing is a thin bed, subdivided into four quadrants. The second housing holds a deep bed, followed by a third housing that holds a second thin bed. The first thin bed will allow periodic samples to be taken to examine the effect of time-on-line on sorbent performance. The second bed (deep bed) will allow a determination of the DF for the sorbent over time by the analysis of the third thin bed, which will be replaced at intervals during the multi-month test period. This system was been installed in the south hood of laboratory 38 in Building 4505, and the necessary safety documentation has been revised to reflect the addition of the KIN-TEK iodine generator.

47 OTHER INSTRUMENTATION↗

Pressurizing Hagan and SAVY containers to 30-psig (air) to measure the release of analytical cerium oxide test powder

The need to pressure-test known nuclear material storage containers has been made apparent by the CSE (cognizant systems engineer) assigned to containers at TA-55. The main goal of the current study is to understand the behavior of the SAVY-4000 and Hagan containers during an internal pressurization (30 psig) event. The experiments incorporated a nominal mass of 100 g of CeO 2 (cerium oxide) powder to simulate MAR (material at risk) conditions. For the experimental results with mass losses of 0.0±0.1 g mass loss), using ASME error analysis, there is a total expanded uncertainty in a 95% confidence interval (±0.25 g) for the tested SAVY-4000 and Hagan containers. For purposes of conservatism, this has been rounded upward to yield a bounding value for the damage ratio DR = 0.003 = 0.3%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SENTRA: A Modular Computational Graph Framework for Critical Mineral and Materials Supply Chains: Part I: Network Construction Latent-Quantity Estimation, and Temporal Graph Forecasting

Global supply chains for critical minerals and materials are complex, evolving networks of countries, products, production stages, and trade relationships. Existing analytical approaches are limited by fragmented data and static network representations that do not capture the dynamic production dependencies linking raw materials, intermediate products, and final goods across multiple countries. Trade and production statistics provide only a partial view of domestic production, inventories, and material flows, making it difficult to identify indirect sourcing pathways, hidden dependencies, and embedded foreign exposures. This paper introduces the Supply Chain Exposure Network Tracking and Risk Assessment (SENTRA) framework, a modular graph-based computational framework for constructing, analyzing, and forecasting dynamic supply chain networks. As the first paper in a three-part methodological series, it establishes the computational foundation of SENTRA by constructing a temporal attributed multi-relational graph whose nodes represent product–country pairs and whose edges encode observed trade and within-country value-chain relationships. Statistical estimation and constrained optimization recover latent production, final demand, and product input dependency coefficients while enforcing economic accounting constraints. Graph-derived exposure measures quantify direct, transshipment, value-chain, and multi-hop supply chain dependencies independently of the forecasting model. A temporal graph forecasting architecture based on a relational graph neural network then forecasts the evolution of the graph under mass-balance constraints with distribution-free conformal uncertainty quantification. Validation on the global aluminum supply chain shows that the learned graph representations recover economically meaningful supply chain structure, accurately forecast out-of-sample trade relationships, and produce well-calibrated prediction intervals. Subsequent papers apply this computational foundation to exposure assessment, disruption analysis, and scenario-based policy analysis, and extend the framework to multimaterial supply chain modeling and decision support.

36 MATERIALS SCIENCE↗

Time Structure of Particle Production in the MERIT High-Power Target Experiment

The MERIT experiment is a proof-of-principle test of a target system for high power proton beam to be used as front-end for a neutrino factory complex or amuon collider. The experiment took data in autumn 2007 with the fast extracted beam from the CERN Proton Synchrotron (PS) to a maximum intensity of about 30 x 10{sup 12} protons per pulse. We report results from the portion of the MERIT experiment in which separated beam pulses were delivered to a free mercury jet target with time intervals between pulses varying from 2 to 700 {micro}s. The analysis is based on the responses of particle detectors placed along side and downstream of the target.

43 PARTICLE ACCELERATORS↗

Hole formation effect on surface morphological response of plasma-facing tungsten

We report simulation results on the effect of helium (He) bubble bursting-mediated surface hole formation on the surface morphological response of tungsten plasma-facing components (PFCs) in nuclear fusion devices. Our analysis is based on an atomistically informed, continuum-scale model, which is capable of accessing the spatiotemporal scales relevant to the fuzz nanostructure formation process on the surface of PFC tungsten. Our simulations account, in an empirical fashion, for two types of subsurface bubble dynamical phenomena in the nanobubble region of PFC tungsten during He plasma irradiation, involving bubble bursting and surface crater formation. We demonstrate that the hole formation effect on the PFC tungsten surface accelerates the growth rate of nanotendrils and the onset of fuzz formation. As a result, the predicted incubation time for surface nanotendril growth is shortened, in agreement with experimental data of incubation fluence at comparable plasma exposure conditions. We also explore systematically the dependence of the PFC surface morphological response on the areal density of holes introduced at regular time intervals onto the He-implanted tungsten surface, a parameter in our analysis that serves as a proxy for the rate of He bubble bursting. More importantly, our simulations capture fine surface features in the PFC tungsten surface morphology and predict that the average spacing between nanotendrils is on the order of 100 nm, consistent with the experimental findings.

Chen, Chao-Shou (ORCID:0000000307910042)↗