Search NASA⌕ Search

SEARCH · Search NASA

Results for “inverter control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Dispatching Grid-Forming Inverters in Grid-Connected and Islanded Mode: Preprint

This paper explores the dispatch-ability of grid-forming (GFM) inverters in grid-connected and islanded mode. Grid-forming (GFM) inverters usually use droop control to automatically share power with other GFM sources (inverters and synchronous generator (SG)) and follow the change of the load demand. However, they can be dispatched like their grid-following (GFL) counterparts to output the target active and reactive power. This will help the grid operator better manage their inverter-based resources (IBRs) for improved operation efficiency and reliability. Therefore, this paper proposes an innovative concept of dispatching GFM sources (inverters and SG) to output the target power for both grid-connected and islanded mode by adjusting their droop intercepts. The fundamental principle of doing so is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, thus, dispatching active and reactve power of a GFM inverter can be achieved through dispatching its frequency and voltage. Moreover, the concept distinguishes the dispatch rules for grid-connected and islanded mode. Finally, the concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one grid-following inverter and loads in both grid-connected and islanded mode. This pioneering work results in a practical guidance for power system energy management system (EMS) development to control a future grid with GFM and GFL inverters.

droop control↗

Power Decoupling Method for Voltage Source Inverters Using Grid Voltage Modulated Direct Power Control in Unbalanced System

The grid voltage modulated direct power control (GVM-DPC) is a novel power regulation method for grid-connected voltage source inverters (VSI). However, interactions between real and reactive powers still exist in GVM-DPC under unbalanced grid voltage condition, which may deteriorate its transient performance. Here, this article proposes a power decoupling method for GVM-DPC-based VSI in unbalanced systems based on the dynamic feedforward power compensation strategy, which can reduce the coupling magnitudes of real and reactive powers in the transient stages. First, the power coupling mechanism of positive and negative sequence real and reactive powers of VSI under the unbalanced voltage condition is analyzed. Then, the power coupling magnitudes (PCM) are derived according to relationships among the positive sequence components of real power, reactive power and point of common coupling (PCC) voltages. Next, the PCM are compensated into the GVM-DPC for the better decoupling performance. Furthermore, a stability analysis of the proposed control system is studied based on the impedance model, and a comparison with the traditional power decoupling method based on virtual impedance is conducted to show the superiority of the proposed method. Finally, simulations, hardware-in-loop test and experiment are conducted to validate the effectiveness of the proposed method.

42 ENGINEERING↗

A Nonlinear Direct Power Controller for a Three-Phase Grid-Connected Inverter with Online Parameter Update for PV Application

This work proposes a nonlinear direct power controller for a three-phase grid-connected inverter for photovoltaic application. Grid-connected converters for solar applications require advanced control architectures to ensure optimal operation and extraction of maximum power from the photovoltaic arrays. Therefore, to ensure this, a nonlinear power controller architecture has been proposed to extract the maximum power from the solar arrays and to achieve the most optimal operation. To further improve the performance, a parameter update scheme has been utilized which is based on model reference adaptive system. The latter helps to accomplish not only good dynamic response but also excellent tracking performance. The overall control come estimation architecture is verified based on computer simulations via MATLAB/Simulink and PLECS domain and various important case study results are presented.

direct power control↗

Control Parameter Sensitivity Study for Inverter-Based-Resource Dominated Grids: A Small Signal Stability Approach and Framework

The growing adoption of renewable energy is driving the prevalence of inverter-based resources (IBRs) within power grids. Future power grids will integrate both grid-following IBRs (GFM-IBRs) and grid-forming IBRs (GFL-IBRs) alongside synchronous generators. Therefore, it is crucial to perform stability studies that account for all components and especially control interactions related to IBRs. Extensive research has performed to study the IBR-related stability, however, the sensitivity study of IBRs' control parameters on system stability has not been adequately studied yet, especially from a systematic way. Therefore, this paper conducts a small signal stability analysis for a generic grid with multiple types of resources and develops an analytical framework for assessing the sensitivity of control parameters affecting stability margins. To achieve that, the non-autonomous reduced-order non-linear dynamic model is developed for a generic power system with multiple synchronous generator-based resources (SGBRs), GFM-IBRs, and GFL-IBRs. Based on the analytic model, a systematic framework for parametric sensitivity on systems' asymptotic stability is developed. A parameter sensitivity analysis based on eigenvalue methods is proposed. The impact of the droop controllers of GFM-IBRs, PQ-dispatch and the PLL controller of GFL-IBR on the system asymptotic stability is discussed. This sensitivity study is aiming to provide deep insights on control parameters' impact on system stability, and gives direction for parameter tuning in case of instability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Smart Inverter Twin Model for Anomaly Detection

Smart inverters connected to a communication network are vulnerable to various anomalies in the form of cyberattacks. In this paper, a self-security approach is implemented using the digital twin concept for smart inverters. The digital twin is formed using the inverter’s dynamic model. Then, the incoming setpoints are autonomously examined using the digital twin, and only the safe setpoints are engaged to the inverter’s local controller. This paper demonstrates the details of the self-security algorithm and how the inverter’s digital twin is formed. In particular, the stable and unstable operation region is experimentally verified by changing the power setpoints engaged to the local controller, using a laboratory setup including a three-phase 1.5-kVA SiC-MOSFET inverter and a 12-kW NHR 9410 regenerative power grid emulator. The results demonstrate that the digital twin model can potentially protect inverters from abnormal operation by examining the incoming commands (new setpoints) using the inverter’s digital twin before engaging the setpoints to the local controller.

Hossen, Tareq↗

A Comprehensive Strategy for Grid Forming Control in DC Coupled Photovoltaic and Battery Energy Storage Inverters

This paper presents an integrated DC-DC and DCAC grid-forming control strategy for DC-coupled photovoltaic (PV) plus battery energy storage systems, considering the effect of DC link voltage variations caused by direct PV connections. A power reference algorithm determines power distribution between the PV and battery to the grid while observing device power ratings to prevent the over-rating of components and keep the battery's state of charge within an acceptable range. The simulated utility-scale model in MATLAB/Simulink illustrates its ability against extreme phase angle variation contingencies in the grid while controlled through grid-forming control with a fast dynamic on DC link voltage. The simulation results confirm the effectiveness of the proposed control in integrating PV plus battery configurations with grid forming control and maintaining reliable grid operation under severe grid disturbances.

battery, boost, control, energy storage, grid form↗

Design of a Non-PLL Grid-Forming Inverter for Smooth Microgrid Transition Operation

This paper develops a controller for a grid-forming (GFM) inverter that is capable of operating as either a GFM or grid-feeding source that can improve the operation of a microgrid during on-off grid transitions through use of a novel synchronization approach. Furthermore, this controller avoids use of a phase-locked loop (PLL) and the inverter is able to synchronize with the grid with self-generated voltage and frequency. This prevents the inverter from replicating any grid voltage disturbances in its output—a key disadvantage of many grid-connected inverters that use a PLL. To enable fast synchronization, active synchronization control is adopted both during inverter start-up and microgrid reconnection operation and a method of coordinating synchronization of the inverter with a microgrid controller and grid interconnection circuit breaker is presented. Simulation results for multiple microgrid transition operations and unplanned islanding events demonstrate that the developed non-PLL grid-connected GFM inverter controller and synchronization method are effective in synchronizing the inverter and microgrid to the grid, avoiding phase jump during microgrid transition operation, and improving microgrid islanding transients versus a traditional configuration.

27 ARPA - Advanced Research Projects Agency-Energy↗

Stability and control characteristics of a monoplane missile with large delta wings and various tail controls at Mach 1.90 to 2.86

Wind tunnel tests were conducted to determine the stability and control characteristics of a monoplane missile with large delta wings and various tail configurations. The tests were conducted at angles of attack of approximately 24 degrees and angles of sideslip of about 22 degrees. Tail control configurations were the cruciform, conventional airplane type, and an inverted airplane configuration. Control effectiveness was measured for pitch, yaw, and roll.

Jernell, L. S.↗

Deep Reinforcement Learning Enabled Physical-Model-Free Two-Timescale Voltage Control Method for Active Distribution Systems

Active distribution networks are being challenged by frequent and rapid voltage violations due to renewable energy integration. Conventional model-based voltage control methods rely on accurate parameters of the distribution networks, which are difficult to achieve in practice. This paper proposes a novel physical-model-free two-timescale voltage control framework for active distribution systems. To achieve fast control of PV inverters, the whole network is first partitioned into several subnetworks using voltage-reactive power sensitivity. Then, the scheduling of PV inverters in the multiple sub-networks is formulated as Markov games and solved by a multi-agent soft actor-critic (MASAC) algorithm, where each subnetwork is modeled as an intelligent agent. All agents are trained in a centralized manner to learn a coordinated strategy while being executed based on only local information for fast response. For the slower time-scale control, OLTCs and switched capacitors are coordinated by a single agent-based SAC algorithm using the global information with considering control behaviors of the inverters. Particularly, the two-level agents are trained concurrently with information exchange according to the reward signal calculated from the data-driven surrogate model. Comparative tests with different benchmark methods on IEEE 33-and 123-bus systems and 342-node low voltage distribution system demonstrate that the proposed method can effectively mitigate the fast voltage violations and achieve systematical coordination of different voltage regulation assets without the knowledge of accurate system model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solid State Transformer Architecture and Control Compensation for Common Mode Currents

A high-altitude electromagnetic pulse (HEMP) or similar geomagnetic disturbance (GMD) has the potential to impact the operation of large-scale electric power grids. By introducing low-frequency common-mode (CM) currents, these events can degrade the performance of critical system components, such as large power transformers by introducing CM currents which can lead to magnetic saturation of the transformer core. In this work, a solid-state transformer (SST) is developed to replace susceptible equipment and improve grid resiliency by safely absorbing these CM disturbances. This device will be referred to as a common-mode solid-state transformer (CM-SST). An SST architecture based on a four-legged AC/DC converter is developed. This architecture enables active control of CM signals without disturbing the AC voltages or the real and reactive power delivery capabilities. A system-level model of this architecture is created, and time-domain simulations are performed to evaluate the SST’s performance in response to simulated CM disturbances. A control strategy for mitigating CM current is also investigated. Hamiltonian surface shaping and power flow control (HSSPFC) is used to design a nonlinear controller for the SST’s output inverter. The objectives of the controller are to suppress CM-induced AC current offsets and regulate AC currents to desired setpoints. Nonlinear system analysis is applied to design and validate the controller. Two cases are tested: (a) the proposed four-leg inverter and (b) a standard three-leg inverter. The results show that the proposed controller rapidly mitigates CM disturbances while maintaining high-quality AC current waveforms in the four-leg configuration. Finally, the hardware performance of an SST prototype is evaluated. In particular, the ability of the SST to safely redirect and absorb CM currents is demonstrated, showing how it can protect neighboring conventional transformers in the system. The study confirms that appropriate control laws allow the SST to protect both itself and adjacent transformers during a HEMP or GMD event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Visibility-enhanced model-free deep reinforcement learning algorithm for voltage control in realistic distribution systems using smart inverters

Increasing integration of distributed solar photovoltaic (PV) into distribution networks could result in adverse effects on grid operation. Traditional model-based control algorithms require accurate model information that is difficult to acquire and thus are challenging to implement in practice. Here, this paper proposes a surrogate model-enabled grid visibility scheme to empower deep reinforcement learning (DRL) approach for distribution network voltage regulation using PV inverters with minimal system knowledge. In contrast to existing DRL methods, this paper presents and corroborates the adverse impact of missing load information on DRL performance and, based on this finding, proposes a surrogate model methodology to impute load information utilizing observable data. Additionally, a multi-fidelity neural network is utilized to construct the DRL training environment, chosen for its efficient data utilization and enhanced robustness to data uncertainty. The feasibility and effectiveness of the proposed algorithm are assessed by considering DRL testing across varying degrees of observable load information and diverse training environments on a realistic power system.

14 SOLAR ENERGY↗

Automatic voltage regulation application for PV inverters in low-voltage distribution grids – A digital twin approach

This paper proposes a hierarchical coordinated control strategy for PV inverters to keep voltages in low-voltage (LV) distribution grids within specified limits. The top layer of the proposed architecture consists of the designed automatic voltage regulation (AVR) application, which has access to voltage measurements and grid parameters from the LV distribution grid, both current and historical. The AVR application solves a constrained optimization problem, which provides a set of local control set-points that bring the voltage across the grid within bounds. The middle layer consists of a local Volt/VAR controller, which is adjusted by the AVR app, while the bottom layer is the inner-loop controller of the PV inverter. The proposed method not only improves the voltage quality in the grid but also manages the reactive power outputs of PV inverters efficiently. Further, a digital twin of the cyber-physical system has also been employed that interacts with the control system to ensure its appropriate operation. The effectiveness of the proposed methodology is demonstrated on a representative low-voltage feeder located in Denmark.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive critic design-based reinforcement learning approach in controlling virtual inertia-based grid-connected inverters

In this report, an adaptive critic design (ACD) approach is proposed to control the phase and voltage of a grid-connected virtual synchronous generator (VSG). The penetration of fast responding inertia-less power converters significantly affect the stability of the power system, especially weak systems such as micro grids. The concept of virtual inertia addresses this concern by virtually emulating the behavior of a synchronous generator. However, the conventional VSG is designed based on two conditions: (i) fixed operating point and (ii) inductive grid connections. The performance of VSGs in low-voltage semi-resistive microgrids is far from optimal. To overcome the aforementioned concerns, a heuristic dynamic programing (HDP) approach is proposed to optimally control grid-connected VSGs. The neural-network-based inherence of the HDP enables the proposed technique to adapt to any impedance angle. The HDP controller includes two subnetworks: (i) the action network that controls the system optimally and (ii) the critic network, which evaluates the effectiveness of the action network. The simulation and experimental results are provided to evaluate the effectiveness of the proposed technique. As shown, the HDP-based approach illustrates a better performance in comparison with the conventional PI-based VSG in various operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Attention Enabled Multi-Agent DRL for Decentralized Volt-VAR Control of Active Distribution System Using PV Inverters and SVCs

This paper proposes attention enabled multi-agent deep reinforcement learning (MADRL) framework for active distribution network decentralized Volt-VAR control. Using the unsupervised clustering, the whole distribution system can be decomposed into several sub-networks according to the voltage and reactive power sensitivity relationships. Then, the distributed control problem of each sub-network is modeled as Markov games and solved by the improved MADRL algorithm, where each sub-network is modeled as an adaptive agent. An attention mechanism is developed to help each agent focus on specific information that is mostly related to the reward. All agents are centrally trained offline to learn the optimal coordinated Volt-VAR control strategy and executed in a decentralized manner to make online decisions with only local information. Compared with other distributed control approaches, the proposed method can effectively deal with uncertainties, achieve fast decision makings, and significantly reduce the communication requirements. Comparison results with model-based and other data-driven methods on IEEE 33-bus and 123-bus systems demonstrate the benefits of the proposed approach.

distribution network↗

Phase Shift Control of a Three-Phase Inverter for Balanced Secondary Currents in Misaligned Three-Phase Inductive Power Transfer Systems

This paper presents a strategy for generating fundamental reference voltage commands for a double-sided LCC tuned three-phase wireless power transfer (WPT) system to achieve balanced output currents when the receiver and transmitter are not perfectly aligned. Formulas for translating the normalized fundamental current commands into phase-shift commands for two of the phase legs in a two-level three-phase inverter are derived. The methodology is validated through circuit simulations performed using coupler models derived from finite-element simulations. Simulation results for a 1.5 k W system design are included, which indicate near perfect correction of imbalance in the secondary currents for a typical misalignment case.

Pries, Jason↗