Search NASA⌕ Search

SEARCH · Search NASA

Results for “isotopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Improved Nondestructive Isotopic Analysis with Practical Microcalorimeter Gamma Spectrometers

Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuclear facilities and analytical laboratories. With approximately ten times better energy resolution than high-purity germanium detectors, these instruments can overcome important uncertainty limits. Microcalorimeter gamma spectroscopy is intended to provide nondestructive isotopic analysis capabilities with sufficient precision and accuracy to reduce the need for sampling, chemical separations, and mass spectrometry to meet safeguards and security goals. Key milestones were the development of the SOFIA instrument (Spectrometer Optimized for Facility Integrated Applications) and the SAPPY software (Spectral Analysis Program in PYthon). SOFIA is a compact instrument that combines advances in large multiplexed transition-edge sensor arrays with optimized cryogenic performance to overcome many practical limitations of previous systems. With a 256-pixel multiplexed detector array capable of 5,000 counts per second, measurement time can be comparable to high-purity germanium detectors. SAPPY was developed to determine isotopic ratios in data from SOFIA and other microcalorimeter instruments with an approach similar to the widely-used FRAM software. SAPPY provides a flexible framework with rigorous uncertainty analysis for both microcalorimeter and high purity germanium (HPGe) data, allowing direct comparison. Here, we present current results from the SOFIA instrument, preliminary isotopic analysis using SAPPY, and describe how the technology is being used to explore uncertainty limits of nondestructive isotopic characterization, inform safeguards models, and extract improved nuclear data including gamma-ray branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling Isotope Separation in Electrochemical Lithium Deposition

Naturally occurring Li consists of two stable isotopes, 6 Li with an abundance of about 7.5%, and 7 Li making up the remainder with 92.5%. The development of a 6 Li enrichment technique, in terms of technical reliability and environmental safety to reach 6 Li future requirements, represents a key step in the roadmap for nuclear fusion energy supply worldwide. This paper uses finite element analysis-based models to simulate electrochemical Li isotope separation, which is an attractive method in terms of simplicity, safety, and scalability. In the model, we quantitatively analyze how different electrochemical factors including thermodynamics, charge-transfer kinetics, and diffusivities affect the separation process (separation factor), together with cell parameters, such as cell length and current density. The maximum separation factor of 1.128 could be obtained with the cell under the optimal thermodynamic, kinetic, and diffusive conditions, which is among the highest separation factors ever reported. Furthermore, these results will assist in designing the actual isotope separation setup with large separation factor and appropriate timing for sample collection.

07 ISOTOPE AND RADIATION SOURCES↗

The oxygen stable isotope composition of CRM 125-A UO 2 standard reference material

While there is a clear need for standardized reference materials for analytical calibrations and for inter-laboratory comparisons, there are not currently any for the oxygen stable isotopic composition of uranium oxides. In this paper we summarize the results from four laboratories by seven different methods of oxygen stable isotope analyses using fluorination techniques of CRM 125-A UO 2 Standard Reference Material. We synthesize these data and methods to arrive at a consensus oxygen stable isotope composition for CRM 125-A $δ$ 18 O = -9.63‰ (±0.29‰) VSMOW. We discuss methodological differences between analytical approaches, including furnace vs laser heating, fluorination using BrF 5 or ClF 3 , as well as calibration strategies. We highlight the potential effects of calibration scale compression from single-point calibrations using reference material with $δ$ 18 O values having a large relative difference from the sample being analyzed. We demonstrate how calibration scale compression can yield differences in calibrated $δ$ 18 O values up to ~2‰ for samples with ~20‰ difference from a single reference material, if the calibration slope of different analytical systems differs by 0.1. In conclusion, we suggest the use of liquid water calibration standards sealed in silver capillary tubes for multi-point calibrations of fluorination analysis systems.

07 ISOTOPE AND RADIATION SOURCES↗

Endogenous Production and Vibrational Analysis of Heavy-Isotope-Labeled Peptides from Cyanobacteria

Stable isotope labeling is an extremely useful tool for characterizing the structure, tracing the metabolism, and imaging the distribution of natural products in living organisms using mass-sensitive measurement techniques. In this study, a cyanobacterium was cultured in 15 N/ 13 C-enriched media to endogenously produce labeled, bioactive oligopeptides. The extent of heavy isotope incorporation in these peptides was determined with LC–MS, while the overall extent of heavy isotope incorporation in whole cells was studied with nanoSIMS and AFM-IR. Up to 98 % heavy isotope incorporation was observed in labeled cells. Three of the most abundant peptides, microcystin-LR (MCLR), cyanopeptolin-A (CYPA), and aerucyclamide-A (ACAA), were isolated and further studied with Raman and FTIR spectroscopies and DFT calculations. This revealed several IR and Raman active vibrations associated with functional groups not common in ribosomal peptides, like diene, ester, thiazole, thiazoline, and oxazoline groups, which could be suitable for future vibrational imaging studies. More broadly, this study outlines a simple and relatively inexpensive method for producing heavy-labeled natural products. Finally, manipulating the bacterial culture conditions by the addition of specific types and amounts of heavy-labeled nutrients provides an efficient means of producing heavy-labeled natural products for mass-sensitive imaging studies.

60 APPLIED LIFE SCIENCES↗

Implications of Underground Nuclear Explosion Cavity Evolution for Radioxenon Isotopic Composition

Abstract Isotopic ratios of radioxenons sampled in the atmosphere or subsurface can be used to verify the occurrence of an underground nuclear explosion (UNE). Differences in the half-lives of radioactive xenon precursors and their decay-chain networks produce different time-dependent concentration profiles of xenon isotopes allowing isotopic ratios to be used for tracking UNE histories including estimating the time of detonation. In this study, we explore the potential effects of post-detonation cavity processes: precipitation of iodine precursors, gas seepage, and prompt venting on radioxenon isotopic evolution which influences UNE histories. Simplified analytical models and closed-form solutions yielding a potentially idealized radioactive decay/ingrowth chain in a closed and well-mixed system typically have limited application by not including the partitioning of the radionuclide inventory between a gas phase and rock melt created by the detonation and by ignoring gas transport from the cavity to host rock or ground surface. In reality, either subsurface transport or prompt release that is principally responsible for gas signatures violates the closed-system (or batch-mode) assumption. A closed-form solution representing time-dependent source-term activities is extended by considering the cavity partitioning process, slow seepage, and/or prompt release of gases from the cavity and applied to realistic systems.

Sun, Yunwei (ORCID:0000000194801439)↗

Isotopic signatures as tools to reconstruct the primordial architecture of the Solar System

The significant reorganization of the early Solar System due to giant planet migration has hampered our understanding of where planetary bodies formed. Previously employed proxies for reconstructing the primordial planetary architecture, such as water content or oxidation state, are complicated by post-accretionary processes. Furthermore we investigate basaltic achondrites for their nucleosynthetic isotope signatures in the elements neodymium (Nd) and zirconium (Zr) and show that they are—similar to previously investigated chondritic meteorites—characterized by a relative deficit in isotopes produced by the s-process of nucleosynthesis. Importantly, these data are well correlated with nucleosynthetic signatures observed in other elements, demonstrating that s-process matter was heterogeneously distributed throughout the early Solar System. By comparing these isotopic signatures with potential proxies for Solar System reconstruction and computer modeling, we here argue that this isotopic heterogeneity in bulk meteoritic materials is linked to the original heliocentric distance of formation. Such scaling of nucleosynthetic signatures with heliocentric distance could permit reconstruction of the primordial architecture of the Solar System by ‘cosmolocating’ the accretion orbits of meteoritic parent bodies as a function of incorporated s-process matter.

58 GEOSCIENCES↗

Faraday detector uranium isotope ratio measurement: Insights from solution- and laser ablation-based sampling methodologies on the Neoma MC-ICP-MS

In this study we utilize an all-faraday cup detector configuration on the Neoma MC-ICP-MS to perform uranium isotope ratio determinations from certified reference materials and a nuclear fuel precursor material via solution and laser ablation based sampling methodologies. The goal in performing these measurements is primarily to demonstrate that the all-faraday cup method can produce highly precise and accurate isotope ratios even at relatively low signal intensity levels while also developing a preliminary understanding of how the complex interplay between different amplifier resistor levels (e.g. 10 11 vs 10 13 Ω) and integration times impacts the precision and accuracy of different types of measurements. Our results show that the faraday cups with 1013 Ω resistors in their amplifier feedback loops can be used to produce accurate and relatively precise isotope ratios for ion beams down to ~5 K cps. However, at the lower end of the signal intensities observed in this study, longer integration times are necessary to mitigate the impact of ion beam instability that can occur during laser ablation based sampling. Despite this potential limitation, the all-faraday cup method is highly versatile as exemplified by the analysis of a collection of uranium reference materials with highly variable uranium isotopic compositions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Isotopic dependence of the frequency of optical vibrations in molybdenum monohydride

We show that it is currently known that three hydrides – PdH x , MoH x , and TiH x – exhibit an inverse isotope effect in superconductivity. Namely, the phase with a heavier hydrogen isotope, deuterium, has a higher critical temperature. Hydrides and deuterides of palladium have intensively been studied both experimentally and theoretically, but the origin of the isotope effect has not been established with certainty. The commonly accepted explanation is that the effect is likely to be due to the strong anharmonicity of the optical hydrogen vibrations, which was considered to be responsible for the large deviation of the ratio of the fundamental optical frequencies ω H /ω D = 1.51 from the harmonic value $\sqrt{2}$ ≈ 1.41. In the present paper, powder samples of MoH 1.1(1) and MoD 1.07(3) were synthesized under a hydrogen / deuterium pressure of several gigapascals and studied by inelastic neutron scattering (INS) at ambient pressure and T = 10 K. The INS study demonstrated that optical vibrations of H atoms in MoH 1.1 and D atoms in MoD 1.07 are harmonic and the ratio of fundamental optical frequencies ω H /ω D = 1.44 is close to the harmonic value $\sqrt{2}$ ≈ 1.41. This shows that anharmonicity is not a necessary condition for the presence of the inverse isotope effect. The MoD 1.07 sample was additionally studied by neutron diffraction (ND) at ambient pressure and T = 100 K. In agreement with previous ND results for MoH 1.2 , the ND study of MoD 1.07 showed that deuterium atoms occupied almost all octahedral interstitial sites in its hexagonal close-packed metal lattice and formed a NiAs-type crystal structure with the composition close to MoD. The overstoichiometric composition MoD 1.07 of the deuteride is likely to result from a small fraction D/Mo ~ 0.07 of deuterium atoms partially occupying the tetrahedral interstices.

36 MATERIALS SCIENCE↗

Shape evolution in neutron-rich Rh isotopes: First measurement of negative-parity isomers in 117,119 Rh

The β-delayed γ-ray spectroscopy of neutron-rich 117,119 Rh isotopes has been investigated at the Radioactive Isotope Beam Factory of RIKEN. The 1/2 − isomers in 117,119 Rh have been identified for the first time. The systematics of energy differences between the 9/2 + and 1/2 − states have been extended up to N = 74, which shows a tendency to first increase with the neutron number N, then reach a maximum at N ≈ 68, and subsequently decrease. Self-consistent triaxial relativistic Hartree-Bogoliubov (TRHB) calculations highlight the crucial role of triaxial deformation, particularly in the positive-parity states, in driving the observed evolution of energy differences. A shape transition from axially symmetric to triaxial and back to symmetric deformation is suggested along the Rh isotopic chain. These findings provide new insights into the structure of neutron-rich nuclei in the A ∼ 110 region and motivate further studies of exotic isotopes in this region to explore the interplay between triaxiality and shell evolution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Method for Rapid and Precise Triple Oxygen Isotope Measurements via High-Temperature Conversion to CO Followed by Nickel-Catalyzed CO to CO 2 Conversion and Laser Spectroscopy

Triple oxygen isotopic compositions ( 16 O, 17 O, 18 O) have conventionally been measured via isotope ratio mass spectrometry using O 2 as an analyte. Conversion of sample oxygen to O 2 typically utilizes fluorination chemistry or catalytic equilibration between CO 2 and O 2 . Recently, laser spectroscopy has become a viable alternative for triple oxygen isotope (Δ' 17 O) measurements due to its ease and rapid throughput. Laser spectrometers are currently available for Δ' 17 O analysis of either H 2 O or CO 2 as the analyte gas. So far, these instruments have been used to measure Δ' 17 O of water, carbonate (CO 2 liberated by acid digestion), and atmospheric CO 2 samples. Here, we present a new method for high-precision Δ' 17 O analysis of CO 2 via tunable infrared laser direct absorption spectroscopy that is compatible with a wider range of geochemically important materials. This approach involves converting sample oxygen to CO 2 in two steps. First, the sample oxygen is liberated and reduced to CO by high-temperature conversion at 1450 °C in the presence of excess elemental carbon. Then, CO is catalytically converted to CO 2 over hot nickel at 350 °C. The conversion process is rapid (10 to 30 min) and quantitative. Spectroscopic Δ' 17 O analysis of the resulting CO 2 takes approximately 45 min. By measuring several oxygen isotope standards, we demonstrate that the method is precise (1σ = 12 per meg for procedural replicates) and accurate (within 11 per meg of previously reported values). The method can be applied to most pyrolytic materials where quantitative oxygen conversion is attainable, such as sulfate, phosphate, nitrate, and oxide minerals, water, and organic molecules.

Ellis, Nicholas M. [University of California, Berk↗

Marine Boundary Layer Decoupling and the Stable Isotopic Composition of Water Vapor

Decoupling of the subcloud layer in stratocumulus-topped marine boundary layers (STMBL) influences low-cloud cover by limiting the supply of water vapor from the surface. However, the relative importance of mixing between surface fluxes and other reservoirs of water vapor as a function of the degree of decoupling is poorly understood. Water vapor transport within the STMBL and its response to decoupling is explored using surface measurements of water vapor isotopic composition that were obtained from Graciosa Island, Azores, during the summer and fall of 2018. The data show an inverse relationship between the decoupling metric, Δq, and the degree of drying from an isotopically depleted water vapor source. The isotopic data require some degree of drying with an isotopically depleted source for coupled conditions, and likely require a small amount of mixing even for strongly decoupled conditions. The data are consistent with mixing between purely local reservoirs of water vapor, subjected to a small amount of condensation and fractionation, and do not require the invocation of large-scale transport of water vapor aloft or additional cloud-formation effects aloft.

54 ENVIRONMENTAL SCIENCES↗

National‐Scale Assessment of Total Gaseous Mercury Isotopes Across the United States

Abstract With the 2011 promulgation of the Mercury and Air Toxics Standards by the U.S. Environmental Protection Agency, and the successful negotiation by the United Nations Environment Program of the Minamata Convention, emissions of mercury (Hg) have declined in the United States. While the declines in atmospheric Hg concentrations in North America are encouraging, linking the declines to changing domestic and global source portfolios remains challenging. To address these research gaps, the U.S. Geological Survey initiated the first national‐scale effort to establish a baseline of total gaseous mercury stable isotope values at 31 sites distributed across the United States. Results indicated that unique Hg sources, such as Hg evasion from an elemental Hg contaminated site or free tropospheric intrusions in high altitude sites, were distinguishable from background atmospheric values. Minor gradients were observed across the nation, with regions of heavy industrial activity demonstrating lower δ 202 Hg, but no consistent changes in other isotopes such as Δ 199 Hg and Δ 200 Hg were observed. Furthermore, δ 202 Hg was impacted by foliar uptake and senescence but trends varied between forested regions in the northeastern and midwestern United States. These data demonstrate regional emission sources and other environmental variables can impact total gaseous Hg (TGM) isotope values, highlighting the need to characterize atmospheric Hg isotopes over larger geographical areas to evaluate changes related to national and international Hg regulations.

Tate, Michael T.↗

Isotope engineering for spin defects in van der Waals materials

Abstract Spin defects in van der Waals materials offer a promising platform for advancing quantum technologies. Here, we propose and demonstrate a powerful technique based on isotope engineering of host materials to significantly enhance the coherence properties of embedded spin defects. Focusing on the recently-discovered negatively charged boron vacancy center ($${{{{{{{{\rm{V}}}}}}}}}_{{{{{{{{\rm{B}}}}}}}}}^{-}$$ V B − ) in hexagonal boron nitride (hBN), we grow isotopically purified h 10 B 15 N crystals. Compared to$${{{{{{{{\rm{V}}}}}}}}}_{{{{{{{{\rm{B}}}}}}}}}^{-}$$ V B − in hBN with the natural distribution of isotopes, we observe substantially narrower and less crowded$${{{{{{{{\rm{V}}}}}}}}}_{{{{{{{{\rm{B}}}}}}}}}^{-}$$ V B − spin transitions as well as extended coherence timeT 2 and relaxation timeT 1 . For quantum sensing,$${{{{{{{{\rm{V}}}}}}}}}_{{{{{{{{\rm{B}}}}}}}}}^{-}$$ V B − centers in our h 10 B 15 N samples exhibit a factor of 4 (2) enhancement in DC (AC) magnetic field sensitivity. For additional quantum resources, the individual addressability of the$${{{{{{{{\rm{V}}}}}}}}}_{{{{{{{{\rm{B}}}}}}}}}^{-}$$ V B − hyperfine levels enables the dynamical polarization and coherent control of the three nearest-neighbor 15 N nuclear spins. Our results demonstrate the power of isotope engineering for enhancing the properties of quantum spin defects in hBN, and can be readily extended to improving spin qubits in a broad family of van der Waals materials.

Science & Technology - Other Topics↗

Isotope-dependent Tafel analysis probes proton transfer kinetics during electrocatalytic water splitting

Proton transfer plays an important role in both hydrogen and oxygen evolution reactions during electrocatalytic water splitting to produce green hydrogen. However, directly adapting the conventional proton/deuterium kinetic isotope effect to study proton transfer in heterogeneous electrocatalytic processes is challenging. Here we propose using the shift in the Tafel slope between protic and deuteric electrolytes, or the Tafel slope isotope effect, as an effective probe of proton transfer characteristics. Comparison of the Tafel slope isotope effect for diverse hydrogen and oxygen evolution reaction electrocatalysts in different pH environments reveals that proton transfer is both pH and structure dependent. Using ruthenium oxide as an example, we show that local structure modification can change the rate-determining step from an electrochemical, concerted proton–electron transfer step to a chemical step and improve the oxygen evolution activity in acid. The isotope-dependent Tafel analysis will facilitate a better understanding of the proton transfer behaviours during electrocatalytic processes and provide guidance for designing efficient electrocatalysts.

Chemistry↗

Measurement and microscopic description of odd–even staggering of charge radii of exotic copper isotopes

Nuclear charge radii globally scale with atomic mass number A as A 1/3 , and isotopes with an odd number of neutrons are usually slightly smaller in size than their even-neutron neighbours. This odd–even staggering, ubiquitous throughout the nuclear landscape1, varies with the number of protons and neutrons, and poses a substantial challenge for nuclear theory. Here, we report measurements of the charge radii of short-lived copper isotopes up to the very exotic 78 Cu (with proton number Z = 29 and neutron number N = 49), produced at only 20 ions s –1 , using the collinear resonance ionization spectroscopy method at the Isotope Mass Separator On-Line Device facility (ISOLDE) at CERN. We observe an unexpected reduction in the odd–even staggering for isotopes approaching the N = 50 shell gap. To describe the data, we applied models based on nuclear density functional theory and A-body valence-space in-medium similarity renormalization group theory. Through these comparisons, we demonstrate a relation between the global behaviour of charge radii and the saturation density of nuclear matter, and show that the local charge radii variations, which reflect the many-body polarization effects, naturally emerge from A-body calculations fitted to properties of A ≤ 4 nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Harvesting krypton isotopes from the off-gas of an irradiated water target to generate 76Br and 77Br

Abstract A flowing-water target was irradiated with a 150 MeV/nucleon beam of 78 Kr at the National Superconducting Cyclotron Laboratory to produce 77 Kr and 76 Kr. Real-time gamma-imaging measurements revealed the mass transport of the krypton radioisotopes through the target-water processing, or “isotope harvesting”, system. The production rates were determined to be 2.7(1) × 10 –4 nuclei of 76 Kr and 1.18(6) × 10 –2 nuclei of 77 Kr formed per incident 78 Kr ion. Utilizing an off-gas processing line as part of the isotope harvesting system, a total of 7.2(1) MBq of 76 Kr and 19.1(6) MBq of 77 Kr were collected in cold traps. Through the decay, the daughter radionuclides 76 Br and 77 Br were generated and removed from the traps with an average efficiency of 77 ± 12%. Due to the differences in half-lives of 76 Kr and 77 Kr, it was possible to isolate a pure sample of 76 Br with 99.9% radionuclidic purity. The successful collection of krypton radioisotopes to generate 76 Br and 77 Br demonstrates the feasibility of gas-phase isotope harvesting from irradiated accelerator cooling-water. Larger-scale collections are planned for collecting by-product radionuclides from the Facility for Rare Isotope Beams.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A Short-Lived Isotope Counting System (SLICS) to measure reaction cross sections producing light, beta-decaying nuclei on OMEGA

A new activation detector optimized for short-lived isotopes was designed, installed, and tested on OMEGA. The Short-Lived Isotope Counting System (SLICS) can be positioned as close as 35 cm from the OMEGA target chamber center in a ten-inch-manipulator. Stable target samples can be mounted on the front end of the detector assembly to undergo triton-, deuteron-, or neutron-induced reactions that produce short-lived reaction products that beta decay. The emitted betas are detected in a phoswich configuration to eliminate the gamma background. The detector is optimized for isotopes with half-lives from 150 ms to 20 s, filling a gap in OMEGA’s current activation detectors for isotopes with half-lives >5 min. In a pilot study, SLICS achieved an efficiency of 24.5% ± 2.0% for counting 8Li, with a total of 505.8 ± 4.4 qualifying events. Using the existing triton laser-ion acceleration platform on OMEGA, this detector can be used to measure rarely studied tritium-induced reactions on light nuclei with an estimated uncertainty of 12%. As a result, the design of the detector and its performance during a first experiment employing deuterium as a surrogate will be discussed.

Beta spectrometry↗

Strong mutual increase in the efficiency of isotope-selective laser IR dissociation of molecules under nonequilibrium thermodynamic conditions of the compression shock under irradiation in a bimolecular mixture

We have revealed a strong (by a factor of 2 to 5) mutual increase in the yield of IR molecular dissociation (by the example of CF{sub 2}HCl and CF{sub 3}Br) and a significant (by a factor of 1.5 to 3) lowering of dissociation thresholds in the nonequilibrium thermodynamic conditions of compression shock in the irradiation of the molecules by resonance IR laser radiation in the bimolecular mixture in comparison with their individual irradiation. This opens up the possibility to perform efficient isotope-selective IR dissociation of molecules at lower excitation energy densities (Φ ⩽ 1.5 – 2.0 J cm{sup −2}) and thereby to improve the dissociation selectivity. This was demonstrated by the example of chlorine- and bromine-isotope selective dissociation of the specified molecules, which are characterised by quite small (less than 0.25 cm{sup −1}) isotope shifts in the IR vibrational absorption spectra excited by laser radiation. The enrichment coefficients K {sub enr}({sup 35}Cl / {sup 37}Cl) = 0.90 ± 0.05 in the residual CF{sub 2}HCl gas and K {sub enr}({sup 79}Br / {sup 81}Br) in the resultant Br{sub 2} product are obtained when the CF{sub 2}HCl : CF{sub 3}Br = 1 : 1 molecular mixture and CF{sub 3}Br molecules, respectively, are irradiated by the 9R(30) CO{sub 2} laser line (frequency, 1084.635 cm{sup −1}) at an energy density Φ ≈ 1.3 J cm{sup −2}. (laser isotope separation)

36 MATERIALS SCIENCE↗