1,005 records · Page 17

Dynamic Analysis of the STARC-ABL Propulsion System

In the pursuit of Electrified Aircraft Propulsion (EAP), much of the attention is on the development of hybrid electric concept vehicles and their propulsion systems from a steady state performance perspective. While it is steady-state performance that largely determines the efficiency of civil air transports, engine operability and transient performance define constraints for the steady state design that impact efficiency and system viability. Neglecting dynamics and control technologies can result in an over-designed, sub optimal propulsion system or a concept that is not feasible. Thus, dynamic system studies were conducted on the propulsion system of the conceptual aircraft design known as the Single-aisle Turboelectric AiRCraft with Aft Boundary Layer propulsor (STARC-ABL). This paper describes the development of a controller to verify the baseline concept's feasibility from an operability perspective. Further, studies were conducted to identify excessive stability margin in the baseline design that could be traded for potential benefits in efficiency through an engine re design. This study revealed the potential to reduce the high pressure compressor (HPC) stall margin by 3%. Finally, a study was conducted to investigate the potential benefit of adding energy storage to the STARC-ABL concept that further improves operability and enables more gains in engine efficiency and performance. The energy storage provided an additional 0.5% stall margin can be removed from the HPC.

hybrid electric propulsion

Hazard and risk analysis framework for nuclear power plant–based integrated energy systems

Employing integrated energy systems (IESs) with nuclear power plants (NPPs) can improve NPP utilization by leveraging dedicated thermal and electric power delivery, but it may also increase operational safety risks. This paper presents a framework to identify and quantify hazards and risks for such IESs. The framework combines accidentology to review past industrial accidents with failure modes and effects analysis (FMEA) to identify potential future incidents. Hydrogen explosion and toxic chemical release hazards are of particular concern. Explosion consequences are quantified using the Bauwens-Dorofeev (Bauwens) and trinitrotoluene equivalent mass (TNT-EM) methods, while chemical release consequences are computed using the Gaussian atmospheric dispersion method. Operational disturbances from direct electrical and thermal integration that may affect NPP safety are modeled using probabilistic risk analysis (PRA). Hazards and risks are then evaluated for regulatory compliance. The framework is applied to IESs comprising pressurized or boiling water reactors supplying three levels of thermal and electrical power to industrial customers. Case studies include high-temperature steam electrolysis hydrogen plants of varying capacities and a synthetic fuel production plant. Sensitivity analysis examines piping component failures in the PRA model as a precursor to cost estimation for thermal extraction line design. Additionally, Fussel-Vessely (FV) and risk increase importance (RII) measures identify risk-informed design improvements for the thermal extraction system. FMEA highlights hazards such as loss of offsite power, prompt loss of electrical load, loss of thermal output, and immediate steam diversion, in addition to hydrogen explosions and toxic chemical releases. Both Bauwens and TNT-EM methods suggest maintaining several hundred meters of separation between the NPP and hydrogen facility to mitigate explosion risks. PRA results show a maximum initiating event frequency increase of 1.15% and an overall risk increase of 0.28%. Importance measure analysis identifies upstream pipe leak isolation components as critical. Evaluating the results against safety regulations, it is concluded that hazards and risks can be managed to comply with regulations through risk-informed thermal and electrical connection designs, component selection, maintenance programs, and safe separation distances between NPPs and integrated industrial facilities.

08 - HYDROGEN

Formal Functional Test Designs with a Test Representation Language

The application of the category-partition method to the test design phase of hardware, software, or system test development is discussed. The method provides a formal framework for reducing the total number of possible test cases to a minimum logical subset for effective testing. An automatic tool and a formal language were developed to implement the method and produce the specification of test cases.

J M Hops

SAM Code Enhancements for Fission Product Tracking of Noble Gases and Metals in MSRs

This report documents fiscal year 2026 enhancements to the System Analysis Module (SAM) for modeling fission product transport in liquid-fueled molten salt reactors (MSRs). The work advances three principal areas: noble gas transport, noble metal deposition, and user interface improvements. The noble gas transport capability integrates drift-flux gas transport, Henry’s law two-film interphase mass transfer with pressure-based nucleation suppression, Knudsen-regime pore diffusion into porous graphite with a conjugate salt-graphite interface constraint, built-in material properties, five Sherwood-number mass transfer correlations including three derived from high-fidelity NekRS simulations, and xenon-135 reactivity feedback through SAM’s point-kinetics model. This work also presents a comprehensive verification test suite, including new analytically verified cases for pressure-dependent onset of interphase gas transfer in a stagnant vertical pipe, a postulated FLiBe-graphite Xe extraction permeator, a gravity riser with a fission-product source, and a descending pipe with gas redissolution driven by hydrostatic pressure. A machine learning framework for bubble rise velocity prediction in molten salt systems is developed and benchmarked on molten-salt and diverse aqueous bubble datasets. The best-performing fine-tuned transfer-learning networks achieve an 82% reduction in RMSE relative to the Clift correlation, and is implemented directly in SAM. The noble metal transport capability is developed, including a liquid-wall deposition model and a gas-surface flotation mechanism that transfers insoluble particles entrained by sparging gas to wetted structures. Verification tests and demonstration cases cover the surface deposition, flotation efflux, and flotation shedding. Finally, a new [SpeciesTransport] input structure replaces positional global vectors with selfcontained, order-independent, named species blocks, simplifies the specification of multiphase species and decay chains, and remains fully compatible with existing SAM input files. Together, these developments improve the physical fidelity, verification basis, and usability of SAM for system-level analyses of fissionproduct behavior in MSRs.

Mui, Travis (ORCID:0000000303736470)

Automated scanning probe microscopy of combinatorial ferroelectric libraries: Gaussian-process-guided exploration and noise-aware experiment planning

Combinatorial materials libraries provide an efficient route for mapping composition–property relationships, but their broader impact depends on rapid, quantitative, and functionally relevant characterization. Scanning Probe Microscopy (SPM), including piezoresponse force microscopy (PFM), offers significant potential for quantitative, functionally relevant combi-library readouts. Here, we implement a fully automated SPM workflow for ferroelectric combinatorial libraries and benchmark Gaussian-process-based Bayesian optimization strategies for autonomous experiment planning. The workflow integrates automated probe motion, contact optimization, imaging, and dual amplitude resonance tracking-PFM spectroscopy, and uses scalarized spectroscopic observables to guide subsequent measurements. Stage motion, probe engagement, in-contact tuning, imaging, spectroscopy, and the choice of the next measurement location all proceed without human input. We demonstrate the approach on Sm-doped BiFeO 3 and Zn x Mg 1−x O libraries. By comparing vanilla Bayesian optimization with a measured-noise variant, we show that explicit treatment of local reproducibility can improve modeling of composition-dependent response when the measured variance is physically meaningful, but can also reduce robustness when variability is dominated by outliers or topographic artifacts. Furthermore, these results establish automated SPM as a bridge between combinatorial synthesis and quantitative functional characterization.

Liu, Yu [University of Tennessee, Knoxville, TN (U

Model Correlation and Thermal Analysis of xEMU Boot at Lunar South Pole Temperatures

The National Aeronautics and Space Administration (NASA) Artemis program plans to send astronauts to the lunar south pole, a region of the moon that is colder than previous lunar missions and low earth orbit operations. The spacesuit boots that will be used on these missions will be directly impacted by these extremely cold temperatures (down to ~50 K). To assess the performance of the Exploration Extravehicular Mobility Unit (xEMU) lunar boot in these extreme temperatures, the boot was tested at the Jet Propulsion Lab (JPL) in the Cryogenic Ice Transfer, Acquisition Development, and Excavation Laboratory (CITADEL) thermal vacuum (TVAC) chamber. This data was used to correlate thermal models to predict operational performance of the boots on the lunar south pole. This paper documents the data analysis, thermal boot model correlation, and operational predictions conducted using data from the xEMU TVAC test. Data from the test series was used to determine expected thermal conductances within the boot and between the boot and environment. These conductances were used to correlate a Thermal Desktop model of the xEMU boot across 10 different test points which varied external temperature, internal boot ventilation flowrate, and contact pressure. The correlated model was then used to predict operational performance in the lunar south pole. While the predictions indicate promising evidence for performance of the boots at the 100K test point, there is still substantial uncertainty in performance, particularly at the 48K test point. The results of this test series and model correlation stress the importance of improved testing for characterizing the expected thermal resistance between the outside of the boot and the lunar surface.

xEMU

Model Correlation and Thermal Analysis of xEMU Boot at Lunar South Pole Temperatures

The National Aeronautics and Space Administration (NASA) Artemis program plans to send astronauts to the lunar south pole, a region of the moon that is colder than previous lunar missions and low earth orbit operations. The spacesuit boots that will be used on these missions will be directly impacted by these extremely cold temperatures (down to ~50 K). To assess the performance of the Exploration Extravehicular Mobility Unit (xEMU) lunar boot in these extreme temperatures, the boot was tested at the Jet Propulsion Lab (JPL) in the Cryogenic Ice Transfer, Acquisition Development, and Excavation Laboratory (CITADEL) thermal vacuum (TVAC) chamber. This data was used to correlate thermal models to predict operational performance of the boots on the lunar south pole. This paper documents the data analysis, thermal boot model correlation, and operational predictions conducted using data from the xEMU TVAC test. Data from the test series was used to determine expected thermal conductances within the boot and between the boot and environment. These conductances were used to correlate a Thermal Desktop model of the xEMU boot across 10 different test points which varied external temperature, internal boot ventilation flowrate, and contact pressure. The correlated model was then used to predict operational performance in the lunar south pole. While the predictions indicate promising evidence for performance of the boots at the 100K test point, there is still substantial uncertainty in performance, particularly at the 48K test point. The results of this test series and model correlation stress the importance of improved testing for characterizing the expected thermal resistance between the outside of the boot and the lunar surface.

thermal analysis

High-Fidelity Building Emulator for Integrated Comfort and Energy Analysis using EnergyPlus and Radiance

The growing need for smart, energy-efficient, and occupant-centric buildings has created a demand for advanced control systems that can optimize building operations to balance energy savings, demand flexibility, and comfort. However, current building energy simulation tools, such as EnergyPlus, have limitations that hinder the development and evaluation of these complex control systems. To address this challenge, we introduce a high-fidelity building emulator that dynamically couples EnergyPlus with Radiance for enhanced daylight modeling. The introduced workflow allows researchers and practitioners to rapidly develop and evaluate innovative control solutions. An example study looking at a south-facing office zone revealed up to 67% deviation in predicted light levels, which can significantly impact building assessment.

Yu, Tammie

Boundary Layer Analysis of Shock Tube Flows

Shock tubes offer a controlled environment to reproduce kinetic and radiative phenomena characteristic of atmospheric entry flows under ground-test conditions. The boundary layer developing behind the incident shock wave determines the available test time, influences particle residence times important for similarity scaling, and can affect radiative energy transport. In this study, we couple a quasi-1D space marcher with the compressible boundary-layer equations to numerically compute the post-shock flow in a shock frame of reference for various test gas mixtures representative of different planetary atmospheres. The solvers are individually verified against CFD simulations and analytical correlations available in the literature. Coupled solutions are computed for a finite-rate chemistry in the boundary layer and a non-catalytic isothermal wall. Results yield refined estimates of the maximum separation distance, as well as insights into concentration profiles of relevant species within the boundary layer.

Andrea Fagnani

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Battery Study for the Shuttle Orbiter EAPU Upgrade

The use of Electric Auxiliary Power Unit (EAPU) in commercial, and military aviation, and in commercial electric automobiles, is reviewed. The specifications of the battery to be used in the space shuttle are reviewed, and the possible vendors discussed. The testing activity and the reliability and the safety features are presented.

Otzinger, Burton

Thermal Analysis on Large Format Lithium-Ion Batteries in Thermal Runaway

Lithium-ion (Li-ion) batteries can deliver electrical power across a large range of applications, and large format versions of these batteries are common in aerospace for their low mass and energy dense properties. Li-ion cells usage has increased as they are more power dense than fuel cells and have overall higher performance over lead-acid/NiCd batteries. However, Li-ion cells can experience Thermal Runaway (TR) via electro-chemical, mechanical, or thermal abuse. TR is a phenomenon where the stored energy in a cell is rapidly released along with vented gases and other effluents. A cell is generally determined to be in TR if its internal heat generation has surpassed its ability to dissipate that heat. If a Li-ion cell enters TR, propagation within the battery may occur. Propagation is the chain reaction that can occur to nearby cells due to a cell that has entered TR initially. Understanding a battery’s susceptiveness to propagation is necessary to evaluate risks associated with TR phenomenon. To determine if a battery is designed in a sufficient manner to prevent battery propagation if single cell TR occurs, testing and thermal analysis of the battery must be conducted. The presentation for TFAWS 2026 will cover considerations for battery TR thermal analysis, such as: testing methods, influences on the cells, failure mechanisms, and TR parameters. This presentation will include a walkthrough of an example battery TR thermal analysis, and the results thereof.

Lithium Ion Batteries

Systems Engineering and Analysis in Support of a US Federal Staging Facility for UNF

The US Department of Energy Office of Nuclear Energy (DOE-NE) Office of Spent Fuel and High-Level Waste Disposition is examining a set of system options and conducting supporting analyses to inform the development of an integrated waste management system, which may include one or more federal staging facilities (FSFs) for used nuclear fuel (UNF ) sited using a collaborative siting process. This paper focuses on the ongoing activities in two systems engineering and analysis work areas: (1) data and tools development, validation, and maintenance and (2) systems engineering execution. Within the first work area, the STANDARDS 5.0 UNF data and analysis tool, formerly known as UNF-ST&DARDS, is being developed as a foundational resource to assist in the management of UNF data. It has the key capability to model UNF throughout the entire back end of the fuel cycle. STANDARDS also includes several compatible analysis tools for the time-dependent characterization of UNF and related systems by interfacing with the SCALE code system for nuclear analysis and COBRA-SFS for thermal analysis. Also, within the data and tools area is the Next Generation System Analysis Model (NGSAM), which is an agent-based simulation software tool expressly designed to be capable of modeling the waste management system, including the transportation of UNF to and from a FSF. NGSAM has been developed to enable informed decision-making by providing the capability to analyze various potential system options for the management of UNF and high-level radioactive waste. Finally, in the systems engineering execution area, the team has begun to apply a disciplined systems engineering approach at the system level along with supporting analysis to guide the development of the FSF project requirements (including associated transportation infrastructure). Systems engineering principles and practices and their adaptation/application to design and development activities will ensure that the waste management system is effectively implemented as work proceeds. Other activities include investigating the implications of changes in various assumptions and parameters related to waste management systems, such as UNF acceptance rates, receipt logic, facility capacities and capabilities, use of standardized canisters, and different assumed facility operation start dates. Keywords: federal staging facility (FSF), used nuclear fuel (UNF), integrated waste management (IWM) system, Next Generation System Analysis Model (NGSAM), STANDARDS, systems engineering

Joseph, Robert

Swamp Works Regolith Compaction Technologies

While the level of compaction below the lunar surface increases quickly after only a few cm of depth, in many cases during a construction mission there will be a need to excavate and transport regolith to a new location for cut-and-fill or horizontal construction of structures such as berms. In these cases to achieve high levels of bulk density, compaction must be per-formed. Additionally, in some cases surface technologies such as systems that sinter/melt the surface may desire the maximum possible compaction at the sur-face to improve melting/heating performance and the final material strength properties. Kennedy Space Center’s (KSC) Swamp Works has developed two means of compaction, lunar and mar-tian compaction. Planetary Autonomous Compaction Technology (PACT) which is part of the Multifunction End Effector for Regolith Compaction Acquisition and Transfer (MEERCAT) robotic arm end effector system’s capabilities and the Site Preparation Tooling for Operations on Mobility Platforms (STOMP) vibratory roller compactor. PACT on MEERCAT has been demonstrated to a TRL 5 and STOMP to a TRL 4 in ambient testing. The results of PACT on MEERCAT and STOMP testing will be shared with results for various simulants including BP-1, ICN-LHT-1G (aka CSM-LHT-1G), RDW-LHT-1GH (a simulant developed for the Mason Tipping Point to match characteristics of ICN-LHT-1G), and Exolith LHS-1E. This will also include discussions on methods used to verify relative density before and after compaction and means to verify density effects below depth. To calculate relative density, maximum and minimum densities for simulants were taken from literature and additional lab testing (publication in work).

redwire

Process-level cost analysis of hybrid manufacturing pathways for aerospace structural components

Hybrid manufacturing is a promising route for producing complex aerospace components, yet systematic cost benchmarking across multiple additive-subtractive pathways remains limited. This study presents a comprehensive process-based cost analysis of seven hybrid manufacturing routes, including laser powder bed fusion (L-PBF), powder- and wire-directed energy deposition (DED), wire arc additive manufacturing (WAAM), additive friction stir deposition (AFSD), metal binder jetting (MBJ), and agility forging, followed by scanning and finish machining. Parametric cost models incorporating direct material, labor, and energy costs were developed. L-PBF results are discussed in detail for a pickle fork component and directly compared with commercial pricing. Across all hybrid routes, labor emerged as the dominant cost driver, contributing more than 70% of total manufacturing cost in some cases. AFSD exhibited the lowest cost for aluminum components, with MBJ being its 316 L stainless steel counterpart, after accounting for geometric scaling. Benchmarking against industrial quotes suggests that hybrid manufacturing can achieve cost levels comparable to those of commercial services, although labor-intensive processes exhibit greater deviation. The analysis highlights automation of material handling, setup, and supervision as key opportunities for improving economic competitiveness. Overall, the proposed framework provides a quantitative basis for evaluating and optimizing hybrid manufacturing pathways for aerospace applications.

Baruah, Sweta [ORNL] (ORCID:0009000174256207)

End-To-End Decentralized Transmission Line Protection in IBR-Dominated Weak Grids Using Interpretable Data-Driven Methods

Traditional transmission line protection relies on predictable synchronous-based fault signatures, which frequently fail under the non-standard, current-limited fault characteristics of Inverter-Based Resources (IBRs). This study investigates how to achieve secure, communication-free fault isolation in IBR-dominated weak grids without relying on opaque, computationally heavy "black-box" machine learning algorithms. To address this, we propose a novel, standalone, and inherently interpretable data-driven protection framework. Unlike centralized methods requiring multi-terminal communication, this decentralized approach relies solely on local measurements using a hierarchical linear-kernel Support Vector Machine (SVM). The methodology decomposes the protection task into four sequential stages that mimic traditional protection elements: fault detection and fault direction identification, fault type classification, zone classification, and location estimation. This multi-stage architecture allows for specialized feature engineering at each stage, combining high computational efficiency with logic traceability. The framework's end-to-end performance was validated via C-code and PSCAD/EMTDC co-simulation, utilizing a real-world utility network and an OEM black-box IBR model. The proposed relay achieves 97.2% overall accuracy and provides a reliable trip decision within a 2.5-cycle window. The results confirm 100% accuracy in fundamental fault detection, reliable zone selectivity across low to moderate fault resistances, and robust security against non-fault transients, proving its immediate viability for integration into commercial numerical relays.

24 POWER TRANSMISSION AND DISTRIBUTION

Analysis of Surface and Bulk Behavior in Ni-Pd Alloys

The most salient features of the surface structure and bulk behavior of Ni-Pd alloys have been studied using the BFS method for alloys. Large-scale atomistic simulations were performed to investigate surface segregation profiles as a function of temperature, crystal face, and composition. Pd enrichment of the first layer was observed in (111) and (100) surfaces, and enrichment of the top two layers occurred for (110) surfaces. In all cases, the segregation profile shows alternate planes enriched and depleted in Pd. In addition, the phase structure of bulk Ni-Pd alloys as a function of temperature and composition was studied. A weak ordering tendency was observed at low temperatures, which helps explain the compositional oscillations in the segregation profiles. Finally, based on atom-by-atom static energy calculations, a comprehensive explanation for the observed surface and bulk features will be presented in terms of competing chemical and strain energy effects.

Ordering