Search NASA⌕ Search

SEARCH · Search NASA

Results for “low noise amplifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Investigation into the Origin of the RF Phase Noise for the LISA Laser Transmitter

The Laser Interferometer Space Antenna (LISA) mission is a collaborative consortium led by the European Space Agency (ESA)in cooperation with the National Aeronautics and Space Administration (NASA). LISA’s goal is to capture gravitational wave events, such as spacetime distortions caused by massive orbiting bodies. Multiple low noise, single frequency master oscillator power amplifier (MOPA) lasers with a polarization-maintaining Yb-fiber amplifier will serve as the light sources for the LISA observatory. The NASA Goddard Space Flight Center (GSFC)is currently developing the laser transmitters for this project. The LISA lasers will carry radio frequency (RF)sidebands for exchanging reference RF clock information between spacecrafts. Excess phase noise, especially carrier-sideband differential phase noise added to the modulation side band by the phase modulator and the fiber amplifier, becomes a concern. In the gravitational wave frequency ranges, leading sources of this RF “differential” phase noise can be both intrinsic and extrinsic. Examples of intrinsic sources include thermal load on the active fiber, thermo-mechanical induced birefringence, and nonlinearities in the various passive and active fibers. Extrinsic sources can include external temperature fluctuations and infrasonic mechanical strain or vibrations. These noise spectra usually include both white and pink (1/f) thermal noise contributions. This work investigates the physical origins and impact of these sources of RF phase noise, and their characteristic spectra and management will be discussed.

Laser Interferometer Space Antenna↗

Fast Single-Quantum Measurement with a Multi-Amplifier Sensing Charge-Coupled Device

A novel readout architecture that uses multiple non-destructive floating-gate amplifiers to achieve sub-electron readout noise in a thick, fully-depleted silicon detector is presented. This Multi-Amplifier Sensing Charge-Coupled Device (MAS-CCD) can perform multiple independent charge measurements with each amplifier; measurements with multiple amplifiers can then be combined to further reduce the readout noise. The readout speed of this detector scales roughly linearly with the number of amplifiers without requiring segmentation of the active area. The performance of this detector is demonstrated, emphasizing the ability to resolve individual quanta and the ability to combine measurements across amplifiers to reduce readout noise. The unprecedented low noise and fast readout of the MAS-CCD make it a unique technology for astronomical observations, quantum imaging, and low-energy interacting particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual-polarization 8.45 GHz traveling-wave maser

An 8.5 GHz dual-channel, dual-polarization traveling-wave maser (TWM) amplifier was installed in the XKR solar system radar cone at DSS 14. The TWM is based on the Blk IIA 8.45 GHz maser structure, with two of the four maser stages being used for each channel, and each maser half then followed by a high-performance GaAs FET amplifier to achieve the desired net gain. A shortened low-noise input waveguide and an orthogonal-mode junction which is cooled to 4.5 K feeds each amplifier chain. The rotation of an external polarizer permits the polarization of each channel to be defined as either linear or circular. A circular waveguide switch was also developed to provide for noise calibration and to protect the maser from incident transmitter power.

Quinn, R. B.↗

Comparison of the sensitivity of 236 U measurements in environmental samples by MC-ICP-MS and ATONA based high precision U TIMS measurements

The ATONA project is focused upon exploring the improvements in uranium isotope ratio measurements by thermal ionization mass spectrometry (TIMS) provided by a new, capacitor-based, amplifier technology. These “ATONA” Faraday amplifiers (Isotopx Ltd, UK) promise accurate, low-noise measurements of very small signals (< 1 femto-amp) in a traditional Faraday cup, which was only previously possible using an ion counter. This report outlines a series of experiments that were performed to assess the performance of the system in samples that test our rapid analysis procedures, and then compare the results against other mass spectrometry techniques currently available for environmental analyses. The following major goals were achieved: (1) illustrated the importance of 236 U measurements for the screening and analysis of environmental samples; (2) improved sensitivity for 236 U, and then identified 236 U in the 4350B standard at ultra-trace levels (3) Provided comparison of the 236 U sensitivity to multi-collector inductively coupled mass spectrometry techniques (4) Illustrated high TRL for the ATONA based measurement technique. This completes the reporting requirements for task 4 in the project LCP and highlights the utility of the system to make highly sensitive 236 U measurements in programmatically relevant sample matrices and at relevant uranium concentrations.

07 ISOTOPE AND RADIATION SOURCES↗

Noise temperature and noise figure concepts: DC to light

The Deep Space Network is investigating the use of higher operational frequencies for improved performance. Noise temperature and noise figure concepts are used to describe the noise performance of these receiving systems. It is proposed to modify present noise temperature definitions for linear amplifiers so they will be valid over the range (hf/kT) 1 (hf/kT). This is important for systems operating at high frequencies and low noise temperatures, or systems requiring very accurate calibrations. The suggested definitions are such that for an ideal amplifier, T sub e = (hg/k) = T sub q and F = 1. These definitions revert to the present definition for (hf/kT) 1. Noise temperature calibrations are illustrated with a detailed example. These concepts are applied to system signal-to-noise analysis. The fundamental limit to a receiving system sensitivity is determined by the thermal noise of the source and the quantum noise limit of the receiver. The sensitivity of a receiving system consisting of an ideal linear amplifier with a 2.7 K source, degrades significantly at higher frequencies.

Stelzried, C. T.↗

Enhancement of High-Speed Infrared Array Electronics (Center Director's Discretionary Fund)

A state-of-the-art infrared detector was to be used as the sensor in a new spectrometer-camera for astronomical observations. The sensitivity of the detector required the use of low-noise, high-speed electronics in the system design. The key component in the electronic system was the pre-amplifier that amplified the low voltage signal coming from the detector. The system was designed based on the selection of the amplifier and that was driven by the maximum noise level, which would yield the desired sensitivity for the telescope system.

Sutherland, W. T.↗

Communications Transceivers for Venus Surface Missions

The high temperature of the surface of Venus poses many difficulties. Previous Venus landers have only operated for short durations before succumbing to the heat. NASA Glenn Research Center conducted a study on communications for long duration Venus surface missions. I report the findings in this presentation. Current technology allows production of communications transceivers that can operate on the surface of Venus, at temperatures above 450 C and pressures of over 90 atmospheres. While these transceivers would have to be relatively simple, without much of the advanced signal processing often used in modern transceivers, since current and near future integrated circuits cannot operate at such high temperatures, the transceivers will be able to meet the requirements of proposed Venus Surface mission. The communication bands of interest are High Frequency or Very High Frequency (HFNHF) for communication between Venus surface and airborne probes (including surface to surface and air to air), and Ultra High Frequency (UHF) to Microwave bands for communication to orbiters. For HFNHF, transceivers could use existing vacuum tube technology. The packaging of the vacuum tubes may need modification, but the internal operating structure already operates at high temperatures. Using metal vacuum structures instead of glass, allows operation at high pressure. Wide bandgap transistors and diodes may be able to replace some of the thermionic components. VHF communications would be useful for line-of- sight operations, while HF would be useful for short-wave type communications using the Venusian ionosphere. UHF and microwave communications use magnetically focused thermionic devices, such as traveling wave tubes (TWTs), magnetron (M-type) amplifiers, and klystrons for high power amplifiers, and backward wave oscillators (BWOs) and reflex klystrons for oscillators. Permanent magnets are already in use in industry that can operate at 500 C. These magnets could focus electron beam tubes on the surface of Venus. While microwave windows will need to be designed for the high pressure, diamond windows have already been demonstrated, so high-pressure microwave windows can be designed and built. Thus, all of these devices could be useful for Venus surface missions. Current electronic power conditioners to supply the high voltages used in these microwave devices cannot operate at high temperatures, but earlier electronic power conditioners that used vacuum tubes can be modified to work at high temperature. Evaluating the various devices in this study, the M-type traveling wave tube (where a traveling wave structure is used in a crossed-field device, similar to the Amplitron used on the Apollo missions) stood out for the high power amplifier since it requires a single high voltage, simplifying the power supply design. Since the receiver amplifier is a low power amplifier, the loss of efficiency in linear beam devices without a depressed collector (and thus needing a single high voltage) is not important; a low noise TWT is a possible solution. Before solid-state microwave amplifiers were available, such TWTs were built with a 1-2 dB noise figure. A microwave triode or transistor made from a wide bandgap material may be preferable, if available. Much of the development work needed for Venusian communication devices will need to focus on the packaging of the devices, and their connections, but the technology is available to build transceivers that can operate on the surface of Venus indefinitely.

Force, Dale A.↗

Phase-Noise and Amplitude-Noise Measurement of Low-Power Signals

Measuring the phase fluctuation between a pair of low-power microwave signals, the signals must be amplified before detection. In such cases the phase noise of the amplifier pair is the main cause of 1/f background noise of the instrument. this article proposes a scheme that makes amplification possible while rejecting the close in 1/f (flicker) noise of the two amplifiers. Noise rejection, which relies upon the understanding of the amplifier noise mechanism does not require averaging. Therefore, our scheme can also be the detector of a closed loop noise reduction system. the first prototype, compared to a traditional saturated mixer system under the same condition, show a 24 dB noise reduction of the 1/f region.

phase noise↗

Toward Large Field-of-view X-ray Spectrometers with Magnetic Microcalorimeters

A future X-ray telescope mission like Lynx, a X-ray flagship mission concept, requires a large field of view, high energy resolution, and high spatial resolution. The Magnetic Microcalorimeter (MMC) detectors we are developing for such a mission feature a 5-arcminute field of view, approximately 100,000 pixels, each spanning 0.5–1 arcsecond. These detectors require the readout of 8,000 sensors. Three different array types have been designed to meet scientific goals, two of which utilize thermal multiplexing to reduce the number of readout channels in a scheme called “Hydra.” We are currently fabricating detectors on a recently completed buried wiring wafer with connections to every sensor. The sensors are read out using a microwave multiplexer (μMUX) with flux ramp modulation. A single μMUX can read out approximately 1,000 sensors with only two feed lines. We will report on the test of the first two-dimensional μMUX chip, consisting of 78 resonators. μMUX chips that pass screening will be directly bonded to MMC array chips using indium bump bonding. In parallel, we have tested a kinetic inductance traveling wave parametric amplifier (KI-TWPA) to amplify signals at low temperatures. The KI-TWPA exhibits extremely low internal noise, approaching the standard quantum limit. Since the energy resolution of an MMC is primarily limited by the readout system, the KI-TWPA is an ideal amplifier for MMCs with μMUX readout. We recently measured the readout noise of a μMUX with a KI-TWPA, demonstrating its capability for reading out MMC arrays. We present the design and fabrication of the latest MMC detectors, along with its readout performance.

Magntic Microcalorimeters↗

Multi-amplifier Sensing Charge-coupled Devices for Next Generation Spectroscopy

We present characterization results and performance of a prototype Multiple-Amplifier Sensing (MAS) silicon charge-coupled device (CCD) sensor with 16 channels potentially suitable for faint object astronomical spectroscopy and low-signal, photon-limited imaging. The MAS CCD is designed to reach sub-electron readout noise by repeatedly measuring charge through a line of amplifiers during the serial transfer shifts. Using synchronized readout electronics based on the Dark Energy Spectroscopic Instrument CCD controller, we report a read noise of 1.03 e$^{−}$ rms pix$^{−1}$ at a speed of 26 μs pix$^{−1}$ with a single-sample readout scheme where charge in a pixel is measured only once for each output stage. At these operating parameters, we find the amplifier-to-amplifier charge transfer efficiency (ACTE) to be >0.9995 at low counts for all amplifiers but one for which the ACTE is 0.997. This charge transfer efficiency falls above 50,000 electrons for the read-noise optimized voltage configuration we chose for the serial clocks and gates. The amplifier linearity across a broad dynamic range from ∼300 to 35,000 e$^{−}$ was also measured to be ±2.5%. We describe key operating parameters to optimize on these characteristics and describe the specific applications for which the MAS CCD may be a suitable detector candidate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved receiver noise calibration for ADMX axion search: 4.54 to 5.41 μeV

Axions are a well-motivated candidate for dark matter. The preeminent method to search for axion dark matter is known as the axion haloscope, which makes use of the conversion of axions to photons in a large magnetic field. Because of the weak coupling of axions to photons, however, the expected signal strength is exceptionally small. To increase signal strength, many haloscopes make use of resonant enhancement and high gain amplifiers, while also taking measures to keep receiver noise as low as possible such as the use of dilution refrigerators and ultra-low-noise electronics. In this paper, we derive the theoretical noise model based on the sources of noise found within a typical axion haloscope receiver chain, using the Axion Dark Matter eXperiment (ADMX) as a case study. We present examples of different noise calibration measurements at 1280 MHz taken during ADMX’s most recent data-taking run. These new results shed light on a previously unidentified interaction between the cavity and Josephson Parametric Amplifier as well as provide a better understanding of the systematic uncertainty on the system noise temperature used in the axion search analysis for this data-taking run. Finally, the consistency between the measurements and the detailed model provide suggestions for future improvements within ADMX and other axion haloscopes to reach a lower noise temperature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of the THS4302 and the Class V Radiation-Tolerant THS4304-SP Silicon Germanium Wideband Amplifiers at Extreme Temperatures

This report discusses the performance of silicon germanium, wideband gain amplifiers under extreme temperatures. The investigated devices include Texas Instruments THS4304-SP and THS4302 amplifiers. Both chips are manufactured using the BiCom3 process based on silicon germanium technology along with silicon-on-insulator (SOI) buried oxide layers. The THS4304-SP device was chosen because it is a Class V radiation-tolerant (150 kRad, TID silicon), voltage-feedback operational amplifier designed for use in high-speed analog signal applications and is very desirable for NASA missions. It operates with a single 5 V power supply [1]. It comes in a 10-pin ceramic flatpack package, and it provides balanced inputs, low offset voltage and offset current, and high common mode rejection ratio. The fixed-gain THS4302 chip, which comes in a 16-pin leadless package, offers high bandwidth, high slew rate, low noise, and low distortion [2]. Such features have made the amplifier useful in a number of applications such as wideband signal processing, wireless transceivers, intermediate frequency (IF) amplifier, analog-to-digital converter (ADC) preamplifier, digital-to-analog converter (DAC) output buffer, measurement instrumentation, and medical and industrial imaging.

Patterson, Richard L.↗

32-GHz Wideband Maser Amplifier

High-gain, wideband, microwave amplifier based on ruby cooled by liquid helium. Features include low input equivalent noise temperature and 400-MHz bandwidth. Design basically extension of previous reflected-wave masers built for frequency range of 18 to 26 GHz. Maser amplifier includes eight stages connected in reflected-wave configuration. Particularly useful for detection of weak microwave signals in radio astronomy and communications.

Shell, J. S.↗

High-Performance Solid-State W-Band Power Amplifiers

The figure shows one of four solid-state power amplifiers, each capable of generating an output power greater than or equal to 240 mW over one of four overlapping frequency bands from 71 to 106 GHz. (The bands are 71 to 84, 80 to 92, 88 to 99, and 89 to 106 GHz.) The amplifiers are designed for optimum performance at a temperature of 130 K. These amplifiers were developed specifically for incorporation into frequency-multiplier chains in local oscillators in a low-noise, far-infrared receiving instrument to be launched into outer space to make astrophysical observations. The designs of these amplifiers may also be of interest to designers and manufacturers of terrestrial W-band communication and radar systems. Each amplifier includes a set of six high-electron-mobility transistor (HEMT) GaAs monolithic microwave integrated-circuit (MMIC) chips, microstrip cavities, and other components packaged in a housing made from A-40 silicon-aluminum alloy. This alloy was chosen because, for the original intended spacecraft application, it offers an acceptable compromise among the partially competing requirements for high thermal conductivity, low mass, and low thermal expansion. Problems that were solved in designing the amplifiers included designing connectors and packages to fit the available space; designing microstrip signal-power splitters and combiners; matching of impedances across the frequency bands; matching of the electrical characteristics of those chips installed in parallel power-combining arms; control and levelling of output power across the bands; and designing the MMICs, microstrips, and microstrip cavities to suppress tendencies toward oscillation in several modes, both inside and outside the desired frequency bands.

Gaier, Todd↗

Investigation of ASIC-based signal readout electronics for LEGEND-1000

LEGEND, the Large Enriched Germanium Experiment for Neutrinoless ββ Decay, is a ton-scale experimental program to search for neutrinoless double beta (0νββ) decay in the isotope 76 Ge with an unprecedented sensitivity. Building on the success of the low-background 76 Ge-based GERDA and Majorana Demonstrator experiments, the LEGEND collaboration is targeting a signal discovery sensitivity beyond 10 28 yr on the decay half-life with approximately 10 t∙yr of exposure. Signal readout electronics in close proximity to the detectors plays a major role in maximizing the experiment's discovery sensitivity by reducing electronic noise and improving pulse shape analysis capabilities for the rejection of backgrounds. However, the proximity also poses unique challenges for the radiopurity of the electronics. Application-specific integrated circuit (ASIC) technology allows the implementation of the entire charge sensitive amplifier (CSA) into a single low-mass chip while improving the electronic noise and reducing the power consumption. In this work, we investigated the properties and electronic performance of a commercially available ASIC CSA, the XGLab CUBE preamplifier, together with a p-type point contact high-purity germanium detector. We show that low noise levels and excellent energy resolutions can be obtained with this readout. Moreover, we demonstrate the viability of pulse shape discrimination techniques for reducing background events.

47 OTHER INSTRUMENTATION↗

Phased Array Radiometer Calibration Using a Radiated Noise Source

Electronic beam steering capability of phased array antenna systems offer significant advantages when used in real aperture imaging radiometers. The sensitivity of such systems is limited by the ability to accurately calibrate variations in the antenna circuit characteristics. Passive antenna systems, which require mechanical rotation to scan the beam, have stable characteristics and the noise figure of the antenna can be characterized with knowledge of its physical temperature [1],[2]. Phased array antenna systems provide the ability to electronically steer the beam in any desired direction. Such antennas make use of active components (amplifiers, phase shifters) to provide electronic scanning capability while maintaining a low antenna noise figure. The gain fluctuations in the active components can be significant, resulting in substantial calibration difficulties [3]. In this paper, we introduce two novel calibration techniques that provide an end-to-end calibration of a real-aperture, phased array radiometer system. Empirical data will be shown to illustrate the performance of both methods.

Srinivasan, Karthik↗