Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

A source of experimental underestimation of aerosol bolus deposition

We examined the measurement error in inhaled and exhaled aerosol concentration resulting from the bolus delivery system when small volumes of monodisperse aerosols are inspired to different lung depths. A laser photometer that illuminated approximately 75% of the breathing path cross section recorded low inhaled bolus half-widths (42 ml) and negative deposition values for shallow bolus inhalation when the inhalation path of a 60-ml aerosol was straight and unobstructed. We attributed these results to incomplete mixing of the inhaled aerosol bolus over the breathing path cross section, on the basis of simultaneous recordings of the photometer with a particle-counter sampling from either the center or the edge of the breathing path. Inserting a 90 degrees bend into the inhaled bolus path increased the photometer measurement of inhaled bolus half-width to 57 ml and yielded positive deposition values. Dispersion, which is predominantly affected by exhaled bolus half-width, was not significantly altered by the 90 degrees bend. We conclude that aerosol bolus-delivery systems should ensure adequate mixing of the inhaled bolus to avoid error in measurement of bolus deposition.

Non-NASA Center↗

Contextual subspace variational quantum eigensolver calculation of the dissociation curve of molecular nitrogen on a superconducting quantum computer

Abstract We present an experimental demonstration of the Contextual Subspace Variational Quantum Eigensolver on superconducting hardware. Calculating the potential energy curve of molecular nitrogen proves challenging for many conventional quantum chemistry techniques, since static correlation dominates in the dissociation limit. Our quantum simulations retain good agreement with the Full Configuration Interaction energy, outperforming all benchmarked single-reference wavefunction techniques in capturing the bond-breaking appropriately. Moreover, our methodology is competitive with multiconfigurational approaches but at a saving of quantum resource, meaning larger active spaces can be treated for a fixed qubit allowance. To achieve this result, we deploy an error mitigation/suppression strategy comprised of Dynamical Decoupling, Measurement-Error Mitigation and Zero-Noise Extrapolation. Circuit parallelization also provides passive noise-averaging and improves the effective shot yield to reduce the measurement overhead. Furthermore, we introduce a modified adaptive ansatz construction algorithm that incorporates hardware awareness into our variational circuits, minimizing the transpilation cost for the target qubit topology.

Physics↗

Accuracy of earth albedo estimates from wide-angle radiation measurements

The instantaneous resolution and accuracy that can be expected from two inversion techniques to be used in the Earth Radiation Budget Experiment (ERBE) are examined. It is shown that measurement errors are magnified by the numerical filter and that this magnification is a function of the magnitude of the inversion factor. By using singular value decomposition, these magnitudes can be reduced to improve the estimates. A simulation of the estimation process using an albedo field derived from scanning radiometer data shows that retaining 6 of the 13 singular values gives the best results. If there are no bidirectional model errors the medium-field-of-view data give the best estimates. However, when bidirectional model errors are considered, the wide-field-of-view measurements give better estimates since they are less sensitive to these errors.

Green, R. N.↗

A curved edge diffraction-utilized displacement sensor for spindle metrology

This paper presents a new dimensional metrological sensing principle for a curved surface based on curved edge diffraction. Spindle error measurement technology utilizes a cylindrical or spherical target artifact attached to the spindle with non-contact sensors, typically a capacitive sensor (CS) or an eddy current sensor, pointed at the artifact. However, these sensors are designed for flat surface measurement. Therefore, measuring a target with a curved surface causes error. This is due to electric fields behaving differently between a flat and curved surface than between two flat surfaces. In this study, a laser is positioned incident to the cylindrical surface of the spindle, and a photodetector collects the total field produced by the diffraction around the target surface. The proposed sensor was compared with a CS within a range of 500 μm. The discrepancy between the proposed sensor and CS was 0.017% of the full range. Its sensing performance showed a resolution of 14 nm and a drift of less than 10 nm for 7 min of operation. This sensor was also used to measure dynamic characteristics of the spindle system (natural frequency 181.8 Hz, damping ratio 0.042) and spindle runout (22.0 μm at 2000 rpm). The combined standard uncertainty was estimated as 85.9 nm under current experiment conditions. It is anticipated that this measurement technique allows for in situ health monitoring of a precision spindle system in an accurate, convenient, and low cost manner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving multiwell petrophysical interpretation from well logs via machine learning and statistical models

Well-log interpretation estimates in situ rock properties along well trajectory, such as porosity, water saturation, and permeability, to support reserve-volume estimation, production forecasts, and decision making in reservoir development. However, due to measurement errors, variability of well logs caused by multiple measurement vendors, different borehole tools, and nonuniform drilling/borehole conditions, estimations of rock properties with original well logs without proper preprocessing may not be accurate, especially in the context of multiwell estimation. Well-log normalization techniques such as two-point scaling and mean-variance normalization are commonly used to improve the robustness of multiwell rock-property estimation. However, these techniques do not consider the correlation between well logs and require subjective knowledge for their effective implementation. To reduce uncertainties and processing time associated with multiwell rock-property estimation from well logs, we develop discriminative adversarial (DA) and linear constraint models for well-log normalization and rock-property estimation. The DA neural network model developed for well-log normalization and interpretation can perform linear and nonlinear well-log normalization while considering the joint distribution of each well log and rock properties. However, the linear constraint model uses an ensemble of predictions from linear models to constrain well-log normalization and rock-property estimation. We also develop a divergence-based type well identification method to select type (training) wells for a test well based on the statistical similarity of associated well-log distributions instead of the interwell distance. We apply the DA model to perform well-log normalization and prediction of permeability for the Seminole San Andres Unit carbonate reservoir. Compared with the permeability predicted with the classical machine learning model without well-log normalization and models with two-point scaling normalization, the DA model yields the most accurate permeability prediction by decreasing the mean-squared error of permeability prediction by 20%–50%.

Geochemistry & Geophysics↗

Single-Shot Decoding of Good Quantum LDPC Codes

Abstract Quantum Tanner codes constitute a family of quantum low-density parity-check codes with good parameters, i.e., constant encoding rate and relative distance. In this article, we prove that quantum Tanner codes also facilitate single-shot quantum error correction (QEC) of adversarial noise, where one measurement round (consisting of constant-weight parity checks) suffices to perform reliable QEC even in the presence of measurement errors. We establish this result for both the sequential and parallel decoding algorithms introduced by Leverrier and Zémor. Furthermore, we show that in order to suppress errors over multiple repeated rounds of QEC, it suffices to run the parallel decoding algorithm for constant time in each round. Combined with good code parameters, the resulting constant-time overhead of QEC and robustness to (possibly time-correlated) adversarial noise make quantum Tanner codes alluring from the perspective of quantum fault-tolerant protocols.

97 MATHEMATICS AND COMPUTING↗

Off-line tracking of series parameters in distribution systems using AMI data

Electric distribution systems have historically lacked measurement points, and equipment is often operated to its failure point, resulting in customer outages. The widespread deployment of sensors at the distribution level is enabling observability. This paper presents an off-line parameter value tracking procedure that takes advantage of the increasing number of measurement devices being deployed at the distribution level to estimate changes in series impedance parameter values over time. The tracking of parameter values enables non-diurnal and non-seasonal change to be flagged for investigation. The presented method uses an unbalanced Distribution System State Estimation (DSSE) and a measurement residual-based parameter estimation procedure. Measurement residuals from multiple measurement snapshots are combined in order to increase the effective local redundancy and improve the robustness of the calculations in the presence of measurement noise. Data from devices on the primary distribution system and from customer meters, via an AMI system, form the input data set. Results of simulations on the IEEE 13-Node Test Feeder are presented to illustrate the proposed approach applied to changes in series impedance parameters. A 5% change in series resistance elements can be detected in the presence of 2% measurement error when combining less than 1 day of measurement snapshots into a single estimate.

Williams, Tess L.↗

Fault-tolerant grid frequency measurement algorithm during transients

Many critical electric grid operations rely on accurate grid frequency measurements. Unfortunately, the measurement accuracy can be easily undermined by power system transient faults. During a power system transient fault, the power grid voltages and currents are usually highly distorted by high-frequency components. What is worse, the power grid signals could have discontinuity during some system transient faults such as phase angle jump, and the discontinuity could result in large measurement errors to state-of-the-art grid measurement algorithms. In this study, a fault-tolerant grid frequency measurement algorithm during transients is proposed. The new algorithm consists of two stages. The first stage is a transient detector, and it can detect the occurrence of system transient faults instantaneously. The second stage is the intelligent frequency estimator, and it will adapt its measurements according to the transient detector. The performance of the algorithm is evaluated under different steady-state and transient conditions. Both dependability and security of the fault-tolerant algorithm are assessed by using PSCAD simulation data and IEEE Standard test data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The impact of data density and data error on the evolution of mesoscale forecast error

The effects of data density and data errors on the accuracy of mesoscale weather forecasts were assessed by simulations of a period in February 1979 when a snowstorm occurred along the U.S. eastern seaboard. The simulations were initiated every 12 hr and the growth of the rms error was tracked as a function of time and varying data densities. A uniform grid of instrumentation separation and perfect boundary conditions were assumed for all the simulations. A bias error representation was defined to account for systematic measurement errors. A brief summary of features of the somewhat complex storm is provided, together with the parameters of the 11 different simulations with high, medium and low data densities. The accuracy of the forecasts were proportional to the data density, although the error decreased for all the simulations over a 24 hr period. The density of the vertical data had a significant impact on the accuracy of the forecast, whereas the horizontal data density did not. Finally, pathways by which errors were transferred among variables were identified.

Warner, T. T.↗

Single pulse vibrational Raman scattering by a broadband KrF excimer laser in a hydrogen-air flame

Spontaneous vibrational Raman scattering (VRS) is produced by a broadband excimer laser at 248 nm (KrF) in a H2-air flame, and VRS spectra are recorded for lean, stoichiometric, and rich flames. Except at very lean flame conditions, laser-induced fluorescence (LIF) processes interfere with VRS Stokes lines from H2, H2O, and O2. No interference is found for the N2 Stokes and N2 anti-Stokes lines. In a stoichiometric H2/air flame, single-pulse measurements of N2 concentration and temperature (by the VRS Stokes to anti-Stokes ratio) have a relative standard deviation of 7.7 and 10 percent, respectively. These single pulse measurement errors compare well with photon statistics calculations using measured Raman cross sections.

Pitz, Robert W.↗

Prelaunch performance of the NASA altimeter for the TOPEX/POSEIDON project

Validation of in-orbit performance has demonstrated the ability of satellite radar altimetry to measure mesoscale absolute dynamic sea surface topography and to measure the variation in the general circulation on the largest spatial scales. Measurements of basin scale mean circulation, however, have been corrupted by system inaccuracies. The TOPEX/POSEIDON radar altimeter satellite applies recent advances in remote sensing instrumentation to reduce long wavelength measurement errors to dramatically lower levels. The TOPEX altimeter measures the range to the ocean surface with 2-cm precision and accuracy through the use of both Ku- and C-band radars, a high pulse repetition frequency, an agile tracker, and absolute internal height calibration. Dual pulse bandwidths for both frequencies make it possible to quickly acquire the surface and begin tracking after crossing the land/ocean boundary. This paper presents the altimeter requirements and the elements of the altimeter design that have resulted in meeting these requirements. Prelaunch test data, based on the use of a Radar Altimeter System Evaluator to simulate the backscatter from the ocean surface, are presented to demonstrate that the TOPEX altimeter will meet these requirements and provide the data necessary to the understanding of basin scale mean circulation.

Marth, Paul C.↗

AMSD Figure Certification Plan

The method planned for the surface figure error measurement of the AMSDs at the XRCF will be discussed. Alignment, surface figure measurement, gravity effects, vibration & temperature environment effects, total error analysis, and data output will be discussed.

Reardon, Pat↗

Standards for Evaluating Radiosonde Measurements

Radiosonde measurement errors occur for various reasons: calibration, mishandling of sensors, poor software, radiation, etc. It is important that these errors be found and corrected, or at the least, corrections determined that might be sensibly applied. Radiation errors apparently are the most serious since the lack of radiative equilibrium between the thermistor and its surrounding environment can not be corrected for just a single thermistor without serious intervention. However, errors may be determined using the Accurate Temperature Measuring (ATM) radiosonde. The ATM radiosonde development was initiated in the mid-1980's using three thermistors; five thermistors are presently incorporated in the ATM radiosonde. Test flights at different locations indicated that the radiative effect on the thermistor varies because of the different environment of each location and, can be corrected. When comparisons between different thermistors (radiosondes) are required the ATM is a valuable tool. Investigation of relative humidity measurements is an ongoing issue because of large discrepancies in observed data. The first chilled mirror (SNOW WHITE) radiosonde was flown from Wallops Flight Facility in 1997. Tests and analyses show the chilled mirror radiosonde present very acceptable data up to the altitude of the tropopause and in some measurements, to 100 hPA. Improvement and better interpretation of the measurements are important. Discussion concentrates on new aspects of the ATM radiosonde application and the utility of the chilled mirror radiosonde.

Schmidlin, F. J.↗

Comparison of fluence-rate determination techniques for the Advanced Test Reactor-Critical Facility

A technique using small, enriched uranium-aluminum alloy monitors to measure fission rates in fuel plate assembly reactors was developed at the Idaho National Laboratory Radiation Measurements Laboratory in support of Advanced Test Reactor Critical (ATR-C) Facility irradiations. Previous measurements were performed to determine the correlation between the beta-particle activity and the fission rate in the U-Al monitors following irradiation. The American Society for Testing and Materials (ASTM) has established a standard practice E704 for determining neutron fluence rate by radioactivation of depleted uranium by measuring the concentration of fission-products in irradiated uranium monitors. Rather than measuring the beta-particle decay from fission-products, the decay rate of fission-products is determined by gamma-ray spectroscopy. The feasibility of using a method adapted from the ASTM standard practice E704 was investigated for ATR-C irradiations and compared to the present method by analyzing a subset of 21 monitor wires using both methods. The resulting calculated fission rates agreed with an average standard deviation of 7.45%, within the average combined measurement error of 9.05%. Practical considerations such as expected fluence-rates, sample activity, and counting-time were compared between the two methods and the sources of error for each method were investigated. Quality assurance measurements utilizing the modified ASTM standard method are recommended for future test irradiation, but gross-beta-particle counting remains the most practical solution for ATR-C fluence-rate determination.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimal wavefront control for adaptive segmented mirrors

A ground-based astronomical telescope with a segmented primary mirror will suffer image-degrading wavefront aberrations from at least two sources: (1) atmospheric turbulence and (2) segment misalignment or figure errors of the mirror itself. This paper describes the derivation of a mirror control feedback matrix that assumes the presence of both types of aberration and is optimum in the sense that it minimizes the mean-squared residual wavefront error. Assumptions of the statistical nature of the wavefront measurement errors, atmospheric phase aberrations, and segment misalignment errors are made in the process of derivation. Examples of the degree of correlation are presented for three different types of wavefront measurement data and compared to results of simple corrections.

Downie, John D.↗

High-Resolution Measurement of Soil Thermal Properties and Moisture Content Using a Novel Heated Fiber Optics Approach

Hydrological parameters are scale dependent. Efficient monitoring techniques capable of measuring hydrological parameters, such as soil moisture content (θ), over a wide range of spatial scales are essential for understanding the complexity of water and energy movement across the landscape. Techniques to measure θ over spatial scales in the range from centimeters to thousands of meters, however, are sorely lacking. Recent improvements in the distributed temperature sensing (DTS) technology supported the development of novel techniques to fill that gap. However, improvements in the accuracy and applicability of DTS techniques are still needed. This study investigates the possibility of improving the accuracy of the fiber optics dual-probe heat-pulse (FO-DPHP) DTS technique by using a new design to maintain the spacing between the FO-DPHP probes and by introducing a novel data interpretation approach. The accuracy of the novel FO-DPHP design was tested at different θ in a sand column experiment. The FO-DPHP measurements obtained using traditional and novel data interpretation approaches were compared against independent measurements from several calibrated soil water content (EC5) sensors. Monte-Carlo analyses were also performed to assess the impact of DTS measurement errors on the accuracy achieved using the data interpretation approaches. The novel design and data interpretation approach allowed for accurate measurements of soil thermal properties and θ without the need to perform a hard-to-achieve soil-specific calibration. Measured θ had mean errors and standard deviations <0.03 and <0.01 m 3 m -3 , respectively, for moisture conditions ranging from dry to near saturation. The standard deviation in the measured heat capacity was <0.01 MJ m -3 K -1 .

42 ENGINEERING↗