Search NASA⌕ Search

SEARCH · Search NASA

Results for “meter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

The magnetic matrix time interval meter

A time interval meter is being developed which allows the recording of a number of event times with high resolution over a relatively long period of time.

Merrill, S. K.↗

Direct-reading inductance meter

Meter indicates from 30 nH to 3 micro H. Reference inductor of 15 micro H is made by winding 50 turns of Number 26 Formvar wire on Micrometal type 50-2 (or equivalent) core. Circuit eliminates requirement for complex instrument compensation prior to taking coil inductance measurement and thus is as easy to operate as common ohmmeter.

Kolbly, R. B.↗

Data system for multiplexed water-current meters

Flow rates at 32 flood plain locations are measured simultaneously by single digital logic unit with high noise immunity. Water flowing through pygmy current meters rotates element that closes electrical contact once every resolution, so flow rate is measured by counting number of closures in time interval.

Ramsey, C. R.↗

Design, fabrication and acoustic tests of a 36 inch (0.914 meter) statorless turbotip fan

The LF336/E is a 36 inch (0.914 meter) diameter fan designed to operate in a rotor-alone configuration. Design features required for modification of the existing LF336/A rotor-stator fan into the LF336/E statorless fan configuration are discussed. Tests of the statorless fan identified an aerodynamic performance deficiency due to inaccurate accounting of the fan exit swirl during the aerodynamic design. This performance deficiency, related to fan exit static pressure levels, produced about a 20 percent thrust loss. A study was then conducted for further evaluation of the fan exit flow fields typical of statorless fan systems. This study showed that through proper selection of fan design variables such as pressure ratio, radius ratio, and swirl distributions, performance of a statorless fan configuration could be improved with levels of thrust approaching the conventional rotor-stator fan system. Acoustic measurements were taken for the statorless fan system at both GE and NASA, and when compared to other lift fan systems, showed noise levels comparable to the quietest lift fan configuration which included rotor-stator spacing and acoustic treatment. The statorless fan system was also used to determine effects of rotor leading edge serrations on noise generations. A cascade test program identified the serration geometry based on minimum pressure losses, wake turbulence levels and noise generations.

Smith, E. G.↗

Feasibility of a 30-meter space based laser transmitter

A study was made of the application of large expandable mirror structures in future space missions to establish the feasibility and define the potential of high power laser systems for such applications as propulsion and power transmission. Application of these concepts requires a 30-meter diameter, diffraction limited mirror for transmission of the laser energy. Three concepts for the transmitter are presented. These concepts include consideration of continuous as well as segmented mirror surfaces and the major stow-deployment categories of inflatable, variable geometry and assembled-in-space structures. The mirror surface for each concept would be actively monitored and controlled to maintain diffraction limited performance at 10.6 microns during operation. The proposed mirror configurations are based on existing aerospace state-of-the-art technology. The assembled-in-space concept appears to be the most feasible, at this time.

Berggren, R. R.↗

Acoustic and aerodynamic performance of a 1.83-meter (6-ft) diameter 1.25-pressure-ratio fan (QF-8)

A 1.25-pressure-ratio 1.83-meter (6-ft) tip diameter experimental fan stage with characteristics suitable for engine application on STOL aircraft was tested for acoustic and aerodynamic performance. The design incorporated proven features for low noise, including absence of inlet guide vanes, low rotor blade tip speed, low aerodynamic blade loading, and long axial spacing between the rotor and stator blade rows. The fan was operated with five exhaust nozzle areas. The stage noise levels generally increased with a decrease in nozzle area. Separation of the acoustic one-third octave results into broadband and pure-tone components showed the broadband noise to be greater than the corresponding pure-tone components. The sideline perceived noise was highest in the rear quadrants. The acoustic results of QF-8 were compared with those of two similar STOL application fans in the test series. The QF-8 had somewhat higher relative noise levels than those of the other two fans. The aerodynamic results of QF-8 and the other two fans were compared with corresponding results from 50.8-cm (20-in.) diam scale models of these fans and design values. Although the results for the full-scale and scale models of the other two fans were in reasonable agreement for each design, the full-scale fan QF-8 results showed poor performance compared with corresponding model results and design expectations. Facility effects of the full-scale fan QF-8 installation were considered in analyzing this discrepancy.

Woodward, R. P.↗

Design, fabrication, and test of a graphite/epoxy metering truss

A graphite/epoxy metering truss as applied to the large space telescope was investigated. A full-scale truss was designed, fabricated and tested. Tests included static limit loadings, a modal survey and thermal-vacuum distortion evaluation. The most critical requirement was the demonstration of the dimensional stability provided by the graphite/epoxy truss concept. Crucial to the attainment of this objective was the ability to make very sophisticated thermal growth measurements which was provided by a seven beam laser interferometer. The design of the basic truss elements were tuned to provide the high degree of dimensional stability and stiffness required by the truss. The struts and spider assembly were fabricated with Fiberite's AS/934 and HMS/934 broadgoods. The rings utilized T300 graphite fabricate with the same materials. The predicted performance of the truss was developed using the NASTRAN program. These results showed conformance with the critical stiffness and thermal distortion requirements and correlated well with the test results.

Oken, S.↗

A precision six-meter deployable boom for the Mariner-Venus-Mercury 1973 magnetometer experiment

A unique deployable boom developed for accurately positioning magnetometers 6 meters (19.7 feet) from a spacecraft is described. Weight, mounting system, magnetic cleanliness, thermal dimensional stability, and natural frequency were critical constraints that were met. The boom was flown on Mariner 10 and deployed flawlessly. The design, development, and testing of the boom and optical alignment of the sensors are described. Design trades and problem solutions are discussed.

Burdick, H. F.↗

Five meter diameter conical furlable antenna

An investigation was made to demonstrate that a 5-meter-diameter, furlable, conical reflector antenna utilizing a line source feed can be fabricated utilizing composite materials and to prove that the antenna can function mechanically and electrically as prototype flight hardware. The design, analysis, and testing of the antenna are described. An RF efficiency of 55% at 8.5 GHz and a surface error of 0.64 mm rms were chosen as basic design requirements. Actual test measurements yielded an efficiency of 53% (49.77 dB gain) and a surface error of 0.61 mm rms. Atmospherically induced corrosion of the reflector mesh resulted in the RF performance degradation. An assessment of the antenna as compared to the current state of the art technology was made. This assessment included cost, surface accuracy and RF performance, structural and mechanical characteristics, and possible applications.

Fortenberry, J. W.↗

Meter-wavelength VLBI. II - The observations

Observations made during a series of meter-wavelength very-long-baseline (VLBI) experiments conducted during 1971-1973 are reported. A wide variety of objects was observed, including many extragalactic sources known to have compact components, several strong pulsars (especially the Crab nebula pulsar), and a selection of supernova remnants. The experiments are discussed in detail, and tests made to check the consistency of the results are described. The measured correlated flux densities are presented for each source as a function of interferometer baseline and observing frequency. An assessment is made of the measurement errors and of the possibility of confusion within the interferometer beam. The results show that all sources except the pulsars, which are known to have intrinsically small sizes, are resolved on the longest baseline. We also conclude that no supernova remnants except the Crab nebula and Cassiopeia A gave evidence of compact components.

Clark, T. A.↗

Pressure distribution on a 1- by 3-meter semispan wing at sweep angles from 0 deg to 40 deg in subsonic flow

A 1- by 3-meter semispan wing of taper ratio 1.0 with NACA 0012 airfoil section contours was tested in the Langley V/STOL tunnel to measure the pressure distribution at five sweep angles, 0 deg, 10 deg, 20 deg, 30 deg, and 40 deg, through an angle-of-attack range from -6 deg to 20 deg. The pressure data are presented as plots of pressure coefficients at each static-pressure tap location on the wing. Flow visualization wing-tuft photographs are also presented for a wing of 40 deg sweep. A comparison between theory and experiment using two inviscid theories and a viscous theory shows good agreement for pressure distributions, normal forces, and pitching moments for the wing at 0 deg sweep.

Yip, L. P.↗

Preliminary test results of the joint FAA-USAF-NASA runway research program. Part 1: Traction measurements of several runways under wet and dry conditions with a Boeing 727, a diagonal-braked vehicle, and a mu-meter

The stopping distance, brake application velocity, and time of brake application were measured for two modern jet transports, along with the NASA diagonal-braked vehicle and the British Mu-Meter on several runways, which when wetted, cover the range of slipperiness likely to be encountered in the United States. Tests were designed to determine if correlation between the aircraft and friction measuring vehicles exists. The test procedure, data reduction techniques, and preliminary test results obtained with the Boeing 727, the Douglas DC-9, and the ground vehicles are given. Time histories of the aircraft test run parameters are included.

Horne, W. B.↗

Direct reading inductance meter

A direct reading inductance meter comprised of a crystal oscillator and an LC tuned oscillator is presented. The oscillators function respectively to generate a reference frequency, f(r), and to generate an initial frequency, f(0), which when mixed produce a difference equal to zero. Upon connecting an inductor of small unknown value in the LC circuit to change its resonant frequency to f(x), a difference frequency (f(r)-f(x)) is produced that is very nearly a linear function of the inductance of the inductor. The difference frequency is measured and displayed on a linear scale in units of inductance.

Kolby, R. B.↗

Pressure distributions on a 1- by 3-meter semispan wing with a nonstreamwise tip in subsonic flow

Pressure distributions on a 1- by 3-meter semispan wing with a tip that is streamwise at 0 deg sweep are presented. The tip becomes nonstreamwise as the wing is swept. At 0 deg sweep angle, the semispan wing has a taper ratio of 1.0 and NACA 0012 airfoil section contours. The test was conducted in the Langley V/STOL tunnel at a freestream dynamic pressure of 2.46 kPa. Pressure distributions are presented for sweep angles of 10, 20, 30, and 40 with an angle of attack range from -6 deg to 20 deg. The data are presented without analysis or discussion.

Yip, L. P.↗

Design, fabrication, and test of a full-scale graphite/epoxy metering truss for the space telescope

This paper presents the work performed in a program sponsored by MSFC-NASA in which a full-scale graphite/epoxy metering truss was designed, fabricated and tested. The primary requirement was to provide a structure that was dimensionally stable in a transient temperature environment. Structural element characterization requiring measurements in the microstrain region are described along with resulting strength, stiffness and coefficient of thermal expansion data. The full-scale tests included static, dynamic and thermal-vacuum dimensional stability evaluations.

Oken, S.↗

Far-Infrared Photometry with an 0.4-Meter Liquid Helium Cooled Balloon-Borne Telescope

A 0.4-meter aperture, liquid helium cooled multichannel far-infrared balloon-borne telescope was constructed to survey the galactic plane. Nine new sources, above a 3-sigma confidence level of 1300 Jy, were identified. Although two-thirds of the scanned area was more than 10 degrees from the galactic plane, no sources were detected in that region; all nine fell within 10 degrees and eight of those within 4 degrees of the galactic equator. Correlations with visible, compact H lines associated with radio continuum and with sources displaying spectra steeply rising between 11 and 20 microns were noted, while stellar objects were not detected.

Jacobson, M. R.↗

X-band antenna gain and system noise temperature of 64-meter deep space stations

A set of measured data on the X-band performance of the three 64-meter deep space stations was obtained for use in future mission telecommunication design and predictions. The test configuration and measurement procedure is described. A method of modelling attenuation due to the atmosphere is given. Radio source brightness temperature and flux density are reviewed.

Benjauthrit, B.↗

Optical fiber waveguide sagnac interferometer. Phase 1: Multiturn one meter diameter, single mode

A rotating ring interferometer was constructed using a 100 meters of single mode optical fiber wound on a crystal cylinder. A 20 inch diameter fiber interferometer gyroscope was built and its sensitivity was evaluated. Major noise sources were identified and improvements for the next phase of development were determined. The accuracy of .01 of a fringe can be improved to .0001 by the removal of the noise source.

Vali, V.↗