Search NASA⌕ Search

SEARCH · Search NASA

Results for “microscopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Development of a scanning transmission x-ray microscope for the beamline P04 at PETRA III DESY

We present a scanning transmission x-ray microscope (STXM) built on top of our existing modular platform for high resolution imaging experiments. This platform consists of up to three separate vacuum chambers and custom designed piezo stages. These piezo stages are able to move precisely in x-, y- and z-direction, this makes it possible to adjust the components for different imaging modes. During recent experiments the endstation was operated mainly as a transmission x-ray microscope (TXM) [1, 2].

43 PARTICLE ACCELERATORS↗

Catalytic enhancement in the performance of the microscopic two-stroke heat engine

Here we consider a model of heat engine operating in the microscopic regime: the two-stroke engine. It produces work and exchanges heat in two discrete strokes that are separated in time. The working body of the engine consists of two d-level systems initialized in thermal states at two distinct temperatures. Additionally, an auxiliary nonequilibrium system called catalyst may be incorporated with the working body of the engine, provided the state of the catalyst remains unchanged after the completion of a thermodynamic cycle. This ensures that the work produced by the engine arises solely from the temperature difference. Upon establishing the rigorous thermodynamic framework, we characterize twofold improvement stemming from the inclusion of a catalyst. Firstly, we prove that in the noncatalytic scenario, the optimal efficiency of the two-stroke heat engine with a working body composed of two-level systems is given by the Otto efficiency, which can be surpassed by incorporating a catalyst with the working body. Secondly, we show that incorporating a catalyst allows the engine to operate in frequency and temperature regimes that are not accessible for noncatalytic two-stroke engines. We conclude with a general conjecture about the advantage brought by a catalyst: including the catalyst with the working body always allows to improve efficiency over the noncatalytic scenario for any microscopic two-stroke heat engines. We prove this conjecture for two-stroke engines where the working body is composed of two d-level systems initialized in thermal states at two distinct temperatures, as long as the final joint state leading to optimal efficiency in the noncatalytic scenario is not a product state, or at least one of the d-level system is not thermal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Emulation of anamorphic imaging on the SHARP extreme ultraviolet mask microscope

The SHARP high-numerical aperture actinic reticle review project is a synchrotron-based, extreme ultraviolet (EUV) microscope dedicated to photomask research. SHARP emulates the illumination and imaging conditions of current EUV lithography scanners and those several generations into the future. An anamorphic imaging optic with increased mask-side numerical aperture (NA) in the horizontal and increased demagnification in the vertical direction has been proposed in this paper to overcome limitations of current multilayer coatings and extend EUV lithography beyond 0.33 NA. Zoneplate lenses with an anamorphic 4×/8× NA of 0.55 are fabricated and installed in the SHARP microscope to emulate anamorphic imaging. SHARP’s Fourier synthesis illuminator with a range of angles exceeding the collected solid angle of the newly designed elliptical zoneplates can produce arbitrary angular source spectra matched to anamorphic imaging. A target with anamorphic dense features down to 50-nm critical dimension is fabricated using 40 nm of nickel as the absorber. In a demonstration experiment, anamorphic imaging at 0.55 4×/8× NA and 6 deg central ray angle (CRA) is compared with conventional imaging at 0.5 4× NA and 8 deg CRA. A significant contrast loss in horizontal features is observed in the conventional images. Finally, the anamorphic images show the same image quality in the horizontal and vertical directions.

36 MATERIALS SCIENCE↗

Four-frequency polarizing microscope for recording plasma images in the wavelength range 0.4-1.1 {mu}m

The optical scheme and design of a four-frequency polarizing microscope intended for simultaneous recording of plasma images in the wavelength range 0.4-1.1 {mu}m with the spatial resolution 12 {mu}m in the entire spectral range are described. The effectiveness of such a microscope in studies of plasmas produced on interaction of laser radiation with a target is demonstrated. The plasma images are obtained at the frequencies {omega}{sub 0}, (3/2){omega}{sub 0}, 2{omega}{sub 0}, and (5/2){omega}{sub 0}, where {omega}{sub 0} corresponds to the frequency of heating radiation. The transformation coefficient that characterizes the efficiency of conversion of heating radiation into the 2{omega}{sub 0}, (3/2){omega}{sub 0}, and (5/2){omega}{sub 0} harmonics generated in the plasma is determined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Response function and optimum configuration of semiconductor backscattered-electron detectors for scanning electron microscopes

A new highly efficient design for semiconductor detectors of intermediate-energy electrons (1-50 keV) for application in scanning electron microscopes is proposed. Calculations of the response function of advanced detectors and control experiments show that the efficiency of the developed devices increases on average twofold, which is a significant positive factor in the operation of modern electron microscopes in the mode of low currents and at low primary electron energies.

36 MATERIALS SCIENCE↗

Europa Luminescence Microscope

The Europa Luminescence Microscope (ELM) is an automated fluorescence and dark-field mi-croscope designed to meet key objectives defined in the NASA Europa Lander Study Report, includ-ing the identification and characterization of morphological biosignatures. ELM’s heritage stems from a 2U cubesat fluorescence microscope, the Fluorescence Analysis for In-situ Research (FLAIR) im-ager, designed and built at NASA Ames Research Center, for the autonomous study of microbial bi-ology in low Earth orbit. For the ELM implementation, a sample is autonomously manipulated with a microfluidic system using in-line filter sets to capture successively smaller particles on 10, 1.0, and 0.1 µm pore-size filters for imaging. For darkfield imaging, ELM uses ultraviolet and visible light to image organic and inorganic structures with submicron resolution. The ability to detect structural and chemical biosignatures as small as 0.2 µm in size is achieved by imaging native fluorescence and us-ing fluorescence microscopy stains to identify key molecular and structural indicators of microbial life (proteins, lipids, nucleic acids). To excite fluorescence, ELM uses LEDs with wavelengths centered near 265, 370, 470, and 530 nm and five emission bands. The use of multiple excitation and emission wavelengths for native fluorescence imaging not only enables the detection of different molecular species, but also their rough classification. Excitation at 265 nm allows for the detection of smaller polyaromatic hydrocarbons (PAHs; 1-5 rings), aromatic amino acids, and proteins with little to no interference from mineral fluorescence, given proper emission band selection. 370 and 470 nm light excites increasingly larger PAH structures (e.g., coronene) and larger aromatic biomolecules that may be present (e.g., protective pigments). Similarly, inorganic fluorescence can be characterized and sep-arated from organic fluorescence, allowing the recognition and in some cases classification, of miner-als and other abiotic particles. ELM is based upon work supported by the NASA COLDTech and ICEE-2 programs.

Microscope↗

Toward the fabrication of a 5 μm resolution Wolter microscope for the National Ignition Facility

Advancements in computer-controlled polishing, metrology, and replication have led to a x-ray mirror fabrication process that is capable of producing high-resolution Wolter microscopes. The mirror is a nickel-cobalt replicated full-shell mirror that was electroformed from a finely figured and polished mandrel. This mandrel was designed and fabricated for a 8 m source-to-detector distance microscope, with 10× magnification. A computer controlled polishing process corrected the low-frequency mandrel figure to < 2.0 nm RMS error. The mandrel design was optimized to reduce shell distortions that occur mainly < 20 mm from the shell ends. This design, in combination with improved replication tooling design and refined bath parameters informed by a detailed COMSOL model, have led to reductions in replication errors in the mirror shell. X-ray tests performed on a pair of mirror shells replicated from the mandrel have demonstrated < 10 μm FWHM source plane imaging resolution. Here we discuss the development process, highlight results from metrology and x-ray testing, and define a path for achieving 5 μm FWHM resolution.

Grazing Incidence, Wolter Microscope, X-ray Optics↗

Quantitative imaging of graphene impedance with the near-field scanning microwave microscope.

Graphene has emerged as a promising material for high speed nano-electronics due to the relatively high carrier mobility that can be achieved. To further investigate electronic transport in graphene and reveal its potential for microwave applications, we employed a near-field scanning microwave microscope with the probe formed by an electrically open end of a 4 GHz half-lambda parallel-strip transmission line resonator. Because of the balanced probe geometry, our microscope allows for truly localized quantitative characterization of various bulk and low-dimensional materials, with the response region defined by the one micron spacing between the two metallic strips at the probe tip. The single- and few-layer graphene flakes were fabricated by a mechanical cleavage method on 300-nm-thick silicon dioxide grown on low resistivity Si wafer. The flake thickness was determined using both AFM and Raman microscopies. We observe clear correlation between the near-field microwave and far-field optical images of graphene produced by the probe resonant frequency shift and thickness-defined color gradation, respectively. We show that the microwave response of graphene flakes is determined by the local sheet impedance, which is found to be predominantly active. Furthermore, we apply a quantitative electrodynamic model relating the probe resonant frequency shift to 2D conductivity of single- and few-layer graphene. From fitting a model to the experimental data we evaluate graphene sheet resistance as a function of thickness. Near-field scanning microwave microscopy can simultaneously image location, geometry, thickness, and distribution of electrical properties of graphene without a need for device fabrication. The approach may be useful for design of graphene-based microwave transistors, quality control of large area graphene sheets, or investigation of chemical and electrical doping effects on graphene transport properties. We acknowledge support from the DOE Center for Integrated Nanotechnologies user support program (grant No.U2008A061), from the NASA NM Space Grant Consortium program, and from the LANL-NMT MOU program supported by UCDRD.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Use of Microscopes and Telescopes in IR Imaging

A wide selection of lenses is very useful to the thermographer working in a research environment, where applications can vary from week to week. Both wide angle and telephoto infrared lenses are widely used alternatives to the standard lenses typically supplied by IR camera manufacturers. However, in some extreme applications the need arises for additional image magnification. In these cases, the thermographer must rely on an IR microscope for close-up work with a field of view on the order of 1.3 to 15.8 mm, or a telescope for working at a distance on the order of meters or kilometers. The advantages of using an IR microscope and reflecting telescope will be discussed, as well as the challenges and characteristics of using these instruments.

99 GENERAL AND MISCELLANEOUS↗

Pulsed Power for a Dynamic Transmission Electron Microscope

Lawrence Livermore National Laboratory (LLNL) has converted a commercial 200kV transmission electron microscope (TEM) into an ultrafast, nanoscale diagnostic tool for material science studies. The resulting Dynamic Transmission Electron Microscope (DTEM) has provided a unique tool for the study of material phase transitions, reaction front analyses, and other studies in the fields of chemistry, materials science, and biology. The TEM's thermionic electron emission source was replaced with a fast photocathode and a laser beam path was provided for ultraviolet surface illumination. The resulting photoelectron beam gives downstream images of 2 and 20 ns exposure times at 100 and 10 nm spatial resolution. A separate laser, used as a pump pulse, is used to heat, ignite, or shock samples while the photocathode electron pulses, carefully time-synchronized with the pump, function as probe in fast transient studies. The device functions in both imaging and diffraction modes. A laser upgrade is underway to make arbitrary cathode pulse trains of variable pulse width of 10-1000 ns. Along with a fast e-beam deflection scheme, a 'movie mode' capability will be added to this unique diagnostic tool. This talk will review conventional electron microscopy and its limitations, discuss the development and capabilities of DTEM, in particularly addressing the prime and pulsed power considerations in the design and fabrication of the DTEM, and conclude with the presentation of a deflector and solid-state pulser design for Movie-Mode DTEM.

42 ENGINEERING↗

Metasurface‐Based Mueller Matrix Microscope

In conventional optical microscopes, image contrast of objects mainly results from the differences in light intensity and/or color. Muller matrix optical microscopes (MMMs), on the other hand, can provide significantly enhanced image contrast and rich information about objects by analyzing their interactions with polarized light. However, state-of-the-art MMMs are fundamentally limited by bulky and slow polarization state generators and analyzers. Here, the study demonstrates a metasurface-based MMM, i.e., Meta-MMM, which is equipped with a chip-integrated, single-shot metasurface polarization state analyzer (Meta-PSA). The Meta-MMM is featured with high-speed measurement (≈2s per Muller matrix (MM) image), superior operation stability, dual-color operation, and high measurement accuracy (measurement error 1–2%) for MM imaging. The Meta-MMM is applied to nanostructure characterization, surface morphology analysis, and discovering birefringent structures in honeybee wings. As a result, the Meta-MMMs hold the promise to revolutionize various applications from biological imaging, medical diagnosis, and material characterization to industry inspection and space exploration.

36 MATERIALS SCIENCE↗

A Platform for Atomic Fabrication and In Situ Synthesis in a Scanning Transmission Electron Microscope

Here, the engineering of quantum materials requires the development of tools able to address various synthesis and characterization challenges. These include the establishment and refinement of growth methods, material manipulation, and defect engineering. Atomic-scale modification will be a key enabling factor for engineering quantum materials where desired phenomena are critically determined by atomic structures. Successful use of scanning transmission electron microscopes (STEMs) for atomic scale material manipulation has opened the door for a transformed view of what can be accomplished using electron-beam-based strategies. However, serious obstacles exist on the pathway from possibility to practical reality. One such obstacle is the in situ delivery of atomized material in the STEM to the region of interest for further fabrication processes. Here, progress on this front is presented with a view toward performing synthesis (deposition and growth) processes in a scanning transmission electron microscope in combination with top-down control over the reaction region. An in situ thermal deposition platform is presented, tested, and deposition and growth processes are demonstrated. In particular, it is shown that isolated Sn atoms can be evaporated from a filament and caught on the nearby sample, demonstrating atomized material delivery. This platform is envisioned to facilitate real-time atomic resolution imaging of growth processes and open new pathways toward atomic fabrication.

36 MATERIALS SCIENCE↗

High-Resolution Momentum Imaging—From Stern’s Molecular Beam Method to the COLTRIMS Reaction Microscope [Book Chapter]

Multi-particle momentum imaging experiments are now capable of providing detailed information on the properties and the dynamics of quantum systems in Atomic, Molecular and Photon (AMO) physics. Historically, Otto Stern can be considered the pioneer of high-resolution momentum measurements of particles moving in a vacuum and he was the first to obtain sub-atomic unit (a.u.) momentum resolution (Schmidt-Böcking et al. in The precision limits in a single-event quantum measurement of electron momentum and position, these proceedings). A major contribution to modern experimental atomic and molecular physics was his so-called molecular beam method, which Stern developed and employed in his experiments. With this method he discovered several fundamental properties of atoms, molecules and nuclei. As corresponding particle detection techniques were lacking during his time, he was only able to observe the averaged footprints of large particle ensembles. Today it is routinely possible to measure the momenta of single particles, because of the tremendous progress in single particle detection and data acquisition electronics. A “state-of-the-art” COLTRIMS reaction microscope can measure, for example, the momenta of several particles ejected in the same quantum process in coincidence with sub-a.u. momentum resolution. Such setups can be used to visualize the dynamics of quantum reactions and image the entangled motion of electrons inside atoms and molecules. This review will briefly summarize Stern’s work and then present in longer detail the historic steps of the development of the COLTRIMS reaction microscope. Furthermore, some benchmark results are shown which initially paved the way for a broad acceptance of the COLTRIMS approach. Finally, a small selection of milestone work is presented which has been performed during the last two decades.

Jahnke, T.↗

Microscopic entropy of AdS3 black holes revisited

A bstract We revisit the microscopic description of AdS 3 black holes in light of recent progress on their higher dimensional analogues. The grand canonical partition function that follows from the AdS 3 /CFT 2 correspondence describes BPS and nearBPS black hole thermodynamics. We formulate an entropy extremization principle that accounts for both the black hole entropy and a constraint on its charges, in close analogy with asymptotically AdS black holes in higher dimensions. We are led to interpret supersymmetric black holes as ensembles of BPS microstates satisfying a charge constraint that is not respected by individual states. This interpretation provides a microscopic understanding of the hitherto mysterious charge constraints satisfied by all BPS black holes in AdS. We also develop thermodynamics and a nAttractor mechanism of AdS 3 black holes in the nearBPS regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Anti-Prostate Cancer Activity of 8-Hydroxyquinoline-2-Carboxaldehyde–Thiosemicarbazide Copper Complexes by Fluorescent Microscopic Imaging

Copper 8-hydroxyquinoline-2-carboxaldehyde–thiosemicarbazide (CuHQTS) and copper 8-hydroxyquinoline-2-carboxaldehyde–4,4-dimethyl-3-thiosemicarbazide (CuHQDMTS) are two copper thiosemicarbazone complexes with potent anticancer activity on cisplatin-resistant neuroblastoma cells. This study aimed to evaluate anti-prostate cancer activity of these two copper complexes in vitro. Both CuHQTS and CuHQDMTS inhibited proliferation of prostate cancer cells and showed cytotoxicity on prostate cancer cells carrying green fluorescent protein (GFP) by fluorescent microscopic imaging. The findings of this study demonstrated anti-prostate cancer activity of CuHQTS and CuHQDMTS and suggested that GFP-carrying prostate cancer cells might be used for testing anticancer activity of copper complexes by fluorescent microscopic imaging.

60 APPLIED LIFE SCIENCES↗

Entrainment in Superfluid Neutron-Star Crusts: Hydrodynamic Description and Microscopic Origin

In spite of the absence of viscous drag, the neutron superfluid permeating the inner crust of a neutron star cannot flow freely and is entrained by the nuclear lattice similarly to laboratory superfluid atomic gases in optical lattices. The role of entrainment on the neutron superfluid dynamics is reviewed. For this purpose, a minimal hydrodynamical model of superfluidity in neutron-star crusts is presented. This model relies on a fully 4-dimensionally covariant action principle. The equivalence of this formulation with the more traditional approach is demonstrated. In addition, the different treatments of entrainment in terms of dynamical effective masses or superfluid density are clarified. The nuclear energy density functional theory employed for the calculations of all the necessary microscopic inputs is also reviewed, focusing on superfluid properties. In particular, the microscopic origin of entrainment and the different methods to estimate its importance are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗