Search NASA⌕ Search

SEARCH · Search NASA

Results for “multimode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Multimodal spectroscopy of order parameter distributions

We present a multimodal spectroscopic paradigm that enables independent measurement of charge and spin degrees of freedom (DOF) in strongly correlated materials. This spin-based technique probes symmetry-specific Hamiltonian parameters by analyzing how the time delay between applied pulses (τ) affects the response. We demonstrate ways in which charge DOF that couple through the quadrupolar interaction (inversion symmetric) can be independently measured even in the presence of large magnetic noise (inversion asymmetric). The method quantifies both the strength of the interactions and their distribution (noise). We provide protocols to directly and independently measure the distribution of interaction strengths, even when the average value of the interaction is zero. By independently measuring distributions of different forms of disorder, this methodology can elucidate which microscopic symmetry drives a phase transition. Here, we discuss potential applications to study complex phase transitions in strongly interacting quantum materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Neural network based analysis of multimodal bond distributions using extended x-ray absorption fine structure spectra

Knowledge of the local coordination environment around atomic species in functional materials is critical for understanding their mechanisms of operation. Heterogeneous mixtures of metal complexes are ubiquitous in catalysts, ionic liquids, molten salts, biological enzymes, and geochemical systems, among many others. Extracting information from ensemble-average measurements about the structural and compositional descriptors of each type of coordination complex comprising the mixture is not generally possible, especially when they possess multimodal bond-length distributions. Here, we developed a method that enables the mapping of an x-ray absorption spectrum on the radial distribution function describing the average environment of the metal ions. The supervised neural network based method utilizes an objective training set, for which the choice of the local structural motifs is completely agnostic to the theoretically expected structure and dynamics of the modeled system. The method was validated using first-principles modeling of structural dynamics of nickel complexation in molten salts, and it applies to a large class of heterogeneous systems, including those studied under in situ and operando conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multimodal synchrotron x-ray diffraction across the superconducting transition of Sr 0.1 Bi 2 Se 3

Here, in the doped topological insulator Sr x Bi 2 ⁢Se 3 , a pronounced in-plane twofold symmetry is observed in electronic properties below the superconducting transition temperature T c ~ 3 K, despite the threefold symmetry of the observed $R\overline{3}m$ space group. The axis of twofold symmetry is nominally pinned to one of three rotationally equivalent crystallographic directions and crystallographic strain has been proposed to be the origin of this pinning. We carried out multimodal synchrotron diffraction and resistivity measurements down to and in magnetic fields up to 45 kG on a single crystal of to probe the effect of superconductivity on the crystallographic distortion. Our results indicate that there is no in-plane crystallographic distortion at the level of 1 x 10 -5 associated with the superconducting transition. These results further support the model that the large twofold in-plane anisotropy of superconducting properties of Sr x Bi 2 ⁢Se 3 is not structural in origin, but electronic, namely, it is caused by a nematic superconducting order parameter of E u symmetry.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multimode Jahn-Teller effect in bulk systems: A case of the N V 0 center in diamond

Here, the multimode Jahn-Teller (JT) effect in a bulk system of a neutral nitrogen-vacancy (NV 0 ) center in diamond is investigated via first-principles density-functional-theory calculations and the intrinsic distortion path (IDP) method. The adiabatic potential energy surface of the electronic ground state of the NV 0 center is calculated based on the local spin-density approximation. Our calculations confirm the presence of the dynamic Jahn-Teller effect in the ground 2 E state of the NV 0 center. Within the harmonic approximation, the IDP method provides the reactive path of JT distortion from unstable high-symmetry geometry to stable low-symmetry energy minimum geometry, and it describes the active normal modes participating in the distortion. We find that there is more than one vibrational mode contributing to the distortion, and their contributions change along the IDP. Several vibrational modes with large contributions to JT distortion, especially those modes close to 44 meV, are clearly observed as the phonon sideband in photoluminescence spectra in a series of experiments, indicating that the dynamic Jahn-Teller effect plays an important role in the optical transition of the NV 0 center.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multimodal fission from self-consistent calculations

When multiple fission modes coexist in a given nucleus, distinct fragment yield distributions appear. Multimodal fission has been observed in a number of fissioning nuclei spanning the nuclear chart, and this phenomenon is expected to affect the nuclear abundances synthesized during the rapid neutron-capture process (𝑟-process). In this study, we generalize the previously proposed hybrid model for fission-fragment yield distributions to predict competing fission modes and estimate the resulting yield distributions. Here, our framework allows for a comprehensive large-scale calculation of fission-fragment yields suited for 𝑟-process nuclear network studies. Nuclear density functional theory is employed to obtain the potential energy and collective inertia tensor on a multidimensional collective space defined by mass multipole moments. Fission pathways and their relative probabilities are determined using the nudged elastic band method. Based on this information, mass and charge fission yields are predicted using the recently developed hybrid model. Fission properties of fermium isotopes are calculated in the axial quadrupole-octupole collective space for three energy density functionals (EDFs). Disagreement between the EDFs appears when multiple fission modes are present. Within our framework, the UNEDF⁢1 HFB EDF agrees best with experimental data. Calculations in the axial quadrupole-octupole-hexadecapole collective space improve the agreement with the experiment for SkM*. We also discuss the sensitivity of fission predictions on the choice of EDF for several superheavy nuclei. Fission-fragment yield predictions for nuclei with multiple fission modes are sensitive to the underlying EDF. For large-scale calculations in which a minimal number of collective coordinates is considered, UNEDF⁢1 HFB provides the best description of experimental data, though the sensitivity motivates robust quantification of the uncertainties of the theoretical model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Transition from wall modes to multimodality in liquid gallium magnetoconvection

Coupled laboratory-numerical experiments of Rayleigh-Bénard convection in liquid gallium subject to a vertical magnetic field are presented. The experiments are carried out in two cylindrical containers with diameter-to-height aspect ratio Γ = 1.0 and 2.0 at varying thermal forcing (Rayleigh numbers 10 5 ≲ Ra ≲ 10 8 ) and magnetic field strength (Chandrasekhar numbers 0 ≲ Ch ≲ 3 × 10 5 ). Laboratory measurements and numerical simulations confirm that magnetoconvection in our finite cylindrical tanks onsets via nondrifting wall-attached modes, in good agreement with asymptotic predictions for a semi-infinite domain. With increasing supercriticality, the experimental and numerical thermal measurements and the numerical velocity data reveal transitions between wall mode states with different azimuthal mode numbers and between wall-dominated convection to wall and interior multimodality. These transitions are also reflected in the heat transfer data, which combined with previous studies connect onset to supercritical turbulent behaviors in liquid metal magnetoconvection over a large parameter space. The gross heat transfer behaviors between magnetoconvection and rotating convection in liquid metals are compared and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multimode One-Way Waveguides of Large Chern Numbers

Current experimental realizations of the quantum anomalous Hall phase in both electronic and photonic systems have been limited to a Chern number of one. In photonics, this corresponds to a single-mode one-way edge waveguide. We predict quantum anomalous Hall phases in photonic crystals with large Chern numbers of 2, 3, and 4. These new topological phases were found by simultaneously gapping multiple Dirac and quadratic points. We demonstrate a continuously tunable power splitter as a possible application of multimode one-way waveguides. All our findings are readily realizable at microwave frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of a Multimode Plasma Response and its Relationship to Density Pumpout and Edge-Localized Mode Suppression

We show density pumpout and edge-localized mode (ELM) suppression by applied n = 2 magnetic fields in low-collisionality DIII-D plasmas to be correlated with the magnitude of the plasma response driven on the high-field side (HFS) of the magnetic axis but not the low-field side (LFS) midplane. These distinct responses are a direct measurement of a multimodal magnetic plasma response, with each structure preferentially excited by a different n = 2 applied spectrum and preferentially detected on the LFS or HFS. Ideal and resistive magneto-hydrodynamic (MHD) calculations find that the LFS measurement is primarily sensitive to the excitation of stable kink modes, while the HFS measurement is primarily sensitive to resonant currents (whether fully shielding or partially penetrated). Finally, the resonant currents are themselves strongly modified by kink excitation, with the optimal applied field pitch for pumpout and ELM suppression significantly differing from equilibrium field alignment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determination of Multimode Motional Quantum States in a Trapped Ion System

Trapped atomic ions are a versatile platform for studying interactions between spins and bosons by coupling the internal states of the ions to their motion. Measurement of complex motional states with multiple modes is challenging, because all motional state populations can only be measured indirectly through the spin state of ions. Here we present a general method to determine the Fock state distributions and to reconstruct the density matrix of an arbitrary multimode motional state. Further, we experimentally verify the method using different entangled states of multiple radial modes in a five-ion chain. This method can be extended to any system with Jaynes-Cummings-type interactions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Multimodal hard X-ray nanoprobe techniques for operando investigations of photovoltaic devices

Compared with conventional laboratory-scale X-ray techniques, synchrotron based X-rays with higher brilliance and higher coherence allow for the investigation of various material properties with high spatial resolution. The microscopic behaviours of materials can be examined using the Hard X-ray Nanoprobe beamline (I14) at Diamond Light Source, which provides a 50 nm focused beam and has been successfully employed to identify nanoscale optoelectronic features in energy-harvesting materials such as halide perovskites that exhibit local heterogeneity. We have developed X-ray beam-induced current (XBIC) measurement capability at I14 to address the growing demand for operando analysis in energy-harvesting research. Here, we demonstrate that X-ray fluorescence (XRF)/XBIC multimodal measurements are feasible at I14 and apply these newly implemented techniques to study perovskite solar cells with various additive concentrations to understand the effect of the additive on nanoscale optoelectronic performance. This expanded operando characterization capability offers the possibility of monitoring nanometre-scale compositional variations and corresponding optoelectronic features of actual solar cell configurations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-energy synchrotron X-ray multimodal computed tomography: enabling multiscale materials characterization at NSLS-II

We report the commissioning of a multimodal computed tomography experimental setup at the 28-ID-2 (XPD) beamline of the National Synchrotron Light Source II. This high-energy (>60 keV) resource features a tunable X-ray beam size ranging from several millimetres to a few micrometres and enables comprehensive characterization of high-Z materials—an essential capability for nuclear and advanced materials research. It provides four complementary computed tomography modalities: X-ray absorption, X-ray fluorescence, X-ray diffraction, and pair distribution function tomography. A case study using a custom-made heterogeneous sample demonstrates these abilities to simultaneously capture atomic, elemental, and morphological information. This unique combination of imaging, structural, and chemical sensitive methods provides a holistic approach to study complex materials with amorphous and crystalline systems across multiple length scales.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simple model for spatial coherence of light at the output of a multimode fiber

A model for the spatial coherence function of a partially coherent light produced at the output of a step-index multimode fiber excited with a spatially coherent broadband source is developed. The field is reflected as a sum of coherent and partially coherent parts, the former being a fully developed speckle and the latter is described by a “Jinc” degree of coherence and uniform intensity over the core of the fiber. The model correctly incorporates all available experimental data, including global degree of coherence, and is intuitive and simple.

42 ENGINEERING↗

Exploring Capability of Multimodal Foundation Model for Image-based Fault Detection of Photovoltaic Modules

Multimodal Foundation Model (MFM), like ChatGPT and Gemini, have emerged as powerful tools for their exceptional natural language processing capabilities and their emerging potential in image analysis. This paper investigates the application of MFMs for photovoltaic (PV) fault detection through image analysis, focusing on ChatGPT 4.0 and Gemini 1.5 Pro. Three types of PV images and the corresponding common PV faults are detected: bird droppings using visible images, cell cracks via electroluminescence (EL) images, and hotspots using infrared (IR) images. Among the two models, Gemini 1.5 Pro demonstrated superior performance, achieving near-perfect results with an average F1 score of 0.97, consistently outperforming ChatGPT 4.0 in accuracy and reliability. Unlike traditional machine learning (ML) models, MFMs can operate in a zero shot manner that does not require additional training by the user, and the input images are not limited by size, angle, scope, or PV technology. The strong adaptability and user-friendliness make MFM a promising tool for analyzing PV images and advancing health monitoring for PV modules.

Li, Baojie↗

4D XCAT phantom for multimodality imaging research

Purpose: The authors develop the 4D extended cardiac-torso (XCAT) phantom for multimodality imaging research. Methods: Highly detailed whole-body anatomies for the adult male and female were defined in the XCAT using nonuniform rational B-spline (NURBS) and subdivision surfaces based on segmentation of the Visible Male and Female anatomical datasets from the National Library of Medicine as well as patient datasets. Using the flexibility of these surfaces, the Visible Human anatomies were transformed to match body measurements and organ volumes for a 50th percentile (height and weight) male and female. The desired body measurements for the models were obtained using the PEOPLESIZE program that contains anthropometric dimensions categorized from 1st to the 99th percentile for US adults. The desired organ volumes were determined from ICRP Publication 89 [ICRP, ''Basic anatomical and physiological data for use in radiological protection: reference values,'' ICRP Publication 89 (International Commission on Radiological Protection, New York, NY, 2002)]. The male and female anatomies serve as standard templates upon which anatomical variations may be modeled in the XCAT through user-defined parameters. Parametrized models for the cardiac and respiratory motions were also incorporated into the XCAT based on high-resolution cardiac- and respiratory-gated multislice CT data. To demonstrate the usefulness of the phantom, the authors show example simulation studies in PET, SPECT, and CT using publicly available simulation packages. Results: As demonstrated in the pilot studies, the 4D XCAT (which includes thousands of anatomical structures) can produce realistic imaging data when combined with accurate models of the imaging process. With the flexibility of the NURBS surface primitives, any number of different anatomies, cardiac or respiratory motions or patterns, and spatial resolutions can be simulated to perform imaging research. Conclusions: With the ability to produce realistic, predictive 3D and 4D imaging data from populations of normal and abnormal patients under various imaging parameters, the authors conclude that the XCAT provides an important tool in imaging research to evaluate and improve imaging devices and techniques. In the field of x-ray CT, the phantom may also provide the necessary foundation with which to optimize clinical CT applications in terms of image quality versus radiation dose, an area of research that is becoming more significant with the growing use of CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A multimodality vascular imaging phantom of an abdominal aortic aneurysm with a visible thrombus

Purpose: With the continuous development of new stent grafts and implantation techniques, it has now become technically feasible to treat abdominal aortic aneurysms (AAA) with challenging anatomy using endovascular repair with standard, fenestrated, or branched stent-grafts. In vitro experimentations are very useful to improve stent-graft design and conformability or imaging guidance for stent-graft delivery or follow-up. Vascular replicas also help to better understand the limitation of endovascular approaches in challenging anatomy and possibly improve surgical planning or training by practicing high risk clinical procedures in the laboratory to improve outcomes in the operating room. Most AAA phantoms available have a very basic anatomy, which is not representative of the clinical reality. This paper presents a method of fabrication of a realistic AAA phantom with a visible thrombus, as well as some mechanical properties characterizing such phantom. Methods: A realistic AAA geometry replica of a real patient anatomy taken from a multidetector computed tomography (CT) scan was manufactured. To demonstrate the multimodality imaging capability of this new phantom with a thrombus visible in magnetic resonance (MR) angiography, CT angiography (CTA), digital subtraction angiography (DSA), and ultrasound, image acquisitions with all these modalities were performed by using standard clinical protocols. Potential use of this phantom for stent deployment was also tested. A rheometer allowed defining hyperelastic and viscoelastic properties of phantom materials. Results: MR imaging measurements of SNR and CNR values on T1 and T2-weighted sequences and MR angiography indicated reasonable agreement with published values of AAA thrombus and abdominal components in vivo. X-ray absorption also lay within normal ranges of AAA patients and was representative of findings observed on CTA, fluoroscopy, and DSA. Ultrasound propagation speeds for developed materials were also in concordance with the literature for vascular and abdominal tissues. Conclusions: The mimicked abdominal tissues, AAA wall, and surrounding thrombus were developed to match imaging features of in vivo MR, CT, and ultrasound examinations. This phantom should be of value for image calibration, segmentation, and testing of endovascular devices for AAA endovascular repair.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A set of 4D pediatric XCAT reference phantoms for multimodality research

Purpose: The authors previously developed an adult population of 4D extended cardiac-torso (XCAT) phantoms for multimodality imaging research. In this work, the authors develop a reference set of 4D pediatric XCAT phantoms consisting of male and female anatomies at ages of newborn, 1, 5, 10, and 15 years. These models will serve as the foundation from which the authors will create a vast population of pediatric phantoms for optimizing pediatric CT imaging protocols. Methods: Each phantom was based on a unique set of CT data from a normal patient obtained from the Duke University database. The datasets were selected to best match the reference values for height and weight for the different ages and genders according to ICRP Publication 89. The major organs and structures were segmented from the CT data and used to create an initial pediatric model defined using nonuniform rational B-spline surfaces. The CT data covered the entire torso and part of the head. To complete the body, the authors manually added on the top of the head and the arms and legs using scaled versions of the XCAT adult models or additional models created from cadaver data. A multichannel large deformation diffeomorphic metric mapping algorithm was then used to calculate the transform from a template XCAT phantom (male or female 50th percentile adult) to the target pediatric model. The transform was applied to the template XCAT to fill in any unsegmented structures within the target phantom and to implement the 4D cardiac and respiratory models in the new anatomy. The masses of the organs in each phantom were matched to the reference values given in ICRP Publication 89. The new reference models were checked for anatomical accuracy via visual inspection. Results: The authors created a set of ten pediatric reference phantoms that have the same level of detail and functionality as the original XCAT phantom adults. Each consists of thousands of anatomical structures and includes parameterized models for the cardiac and respiratory motions. Based on patient data, the phantoms capture the anatomic variations of childhood, such as the development of bone in the skull, pelvis, and long bones, and the growth of the vertebrae and organs. The phantoms can be combined with existing simulation packages to generate realistic pediatric imaging data from different modalities. Conclusions: The development of patient-derived pediatric computational phantoms is useful in providing variable anatomies for simulation. Future work will expand this ten-phantom base to a host of pediatric phantoms representative of the public at large. This can provide a means to evaluate and improve pediatric imaging devices and to optimize CT protocols in terms of image quality and radiation dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-224: Multimodality Segmentation of Head and Neck Tumors

Purpose: Develop an algorithm that is able to automatically segment tumor volume in Head and Neck cancer by integrating information from CT, PET and MR imaging simultaneously. Methods: Twenty three patients that were recruited under an adaptive radiotherapy protocol had MR, CT and PET/CT scans within 2 months prior to start of radiotherapy. The patients had unresectable disease and were treated either with chemoradiotherapy or radiation therapy alone. Using the Velocity software, the PET/CT and MR (T1 weighted+contrast) scans were registered to the planning CT using deformable and rigid registration respectively. The PET and MR images were then resampled according to the registration to match the planning CT. The resampled images, together with the planning CT, were fed into a multi-channel segmentation algorithm, which is based on Gaussian mixture models and solved with the expectation-maximization algorithm and Markov random fields. A rectangular region of interest (ROI) was manually placed to identify the tumor area and facilitate the segmentation process. The auto-segmented tumor contours were compared with the gross tumor volume (GTV) manually defined by the physician. The volume difference and Dice similarity coefficient (DSC) between the manual and autosegmented GTV contours were calculated as the quantitative evaluation metrics. Results: The multimodality segmentation algorithm was applied to all 23 patients. The volumes of the auto-segmented GTV ranged from 18.4cc to 32.8cc. The average (range) volume difference between the manual and auto-segmented GTV was −42% (−32.8%–63.8%). The average DSC value was 0.62, ranging from 0.39 to 0.78. Conclusion: An algorithm for the automated definition of tumor volume using multiple imaging modalities simultaneously was successfully developed and implemented for Head and Neck cancer. This development along with more accurate registration algorithms can aid physicians in the efforts to interpret the multitude of imaging information available in radiotherapy today. This project was supported by a grant by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

A multimodality segmentation framework for automatic target delineation in head and neck radiotherapy

Purpose: To develop an automatic segmentation algorithm integrating imaging information from computed tomography (CT), positron emission tomography (PET), and magnetic resonance imaging (MRI) to delineate target volume in head and neck cancer radiotherapy. Methods: Eleven patients with unresectable disease at the tonsil or base of tongue who underwent MRI, CT, and PET/CT within two months before the start of radiotherapy or chemoradiotherapy were recruited for the study. For each patient, PET/CT and T1-weighted contrast MRI scans were first registered to the planning CT using deformable and rigid registration, respectively, to resample the PET and magnetic resonance (MR) images to the planning CT space. A binary mask was manually defined to identify the tumor area. The resampled PET and MR images, the planning CT image, and the binary mask were fed into the automatic segmentation algorithm for target delineation. The algorithm was based on a multichannel Gaussian mixture model and solved using an expectation–maximization algorithm with Markov random fields. To evaluate the algorithm, we compared the multichannel autosegmentation with an autosegmentation method using only PET images. The physician-defined gross tumor volume (GTV) was used as the “ground truth” for quantitative evaluation. Results: The median multichannel segmented GTV of the primary tumor was 15.7 cm{sup 3} (range, 6.6–44.3 cm{sup 3}), while the PET segmented GTV was 10.2 cm{sup 3} (range, 2.8–45.1 cm{sup 3}). The median physician-defined GTV was 22.1 cm{sup 3} (range, 4.2–38.4 cm{sup 3}). The median difference between the multichannel segmented and physician-defined GTVs was −10.7%, not showing a statistically significant difference (p-value = 0.43). However, the median difference between the PET segmented and physician-defined GTVs was −19.2%, showing a statistically significant difference (p-value =0.0037). The median Dice similarity coefficient between the multichannel segmented and physician-defined GTVs was 0.75 (range, 0.55–0.84), and the median sensitivity and positive predictive value between them were 0.76 and 0.81, respectively. Conclusions: The authors developed an automated multimodality segmentation algorithm for tumor volume delineation and validated this algorithm for head and neck cancer radiotherapy. The multichannel segmented GTV agreed well with the physician-defined GTV. The authors expect that their algorithm will improve the accuracy and consistency in target definition for radiotherapy.

60 APPLIED LIFE SCIENCES↗