Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiplexer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

InP-Based Ridge Waveguide Lasers for Wavelength Division Multiplexing Applications

Wavelength division multiplexed (WDM) systems place stringent requirements on the absolute wavelength and wavelength spacing of the elements in laser arrays. Ridge waveguides (RW) show excellent potential for practical implementation due to their simple fabrication with relaxed fabrication tolerances, high reliability and good performancce. An analysis of the fabrication tolerances for RW and buried heterostructure (BH) devices is performed, showing the advantages offered by the ridge design.

wavelength↗

Large-Scale Magnetic Microcalorimeter: Modeling and Multiplexing

We will present performance predictions for a large-scale magnetic microcalorimeter detector array intended for a potential future X-ray astrophysics mission. The focal plane comprises three distinct array designs, necessitating over 100,000 pixels to meet the scientific objectives. Our presentation will describe the results of numerical modeling aimed at estimating the energy resolution and detector responses for each array. Additionally, we will discuss the application of microwave multiplexing technology for the comprehensive readout of the entire sensor array.

x-ray↗

Wireless Frequency‐Multiplexed Acoustic Array‐Based Acoustofluidics

Abstract Acoustofluidics has shown great potential in enabling on‐chip technologies for driving liquid flows and manipulating particles and cells for engineering, chemical, and biomedical applications. To introduce on‐demand liquid sample processing and micro/nano‐object manipulation functions to wearable and embeddable electronics, wireless acoustofluidic chips are highly desired. This paper presents wireless acoustofluidic chips to generate acoustic waves carrying sufficient energy and achieve key acoustofluidic functions, including arranging particles and cells, generating fluid streaming, and enriching in‐droplet particles. To enable these functions, the wireless acoustofluidic chips leverage mechanisms, including inductive coupling‐based wireless power transfer (WPT), frequency multiplexing‐based control of multiple acoustic waves, and the resultant acoustic radiation and drag forces. For validation, the wirelessly generated acoustic waves are measured using laser vibrometry when different materials (e.g., bone, tissue, and hand) are inserted between the WPT transmitter and receiver. Moreover, the wireless acoustofluidic chips successfully arrange nanoparticles into different patterns, align cells into parallel pearl chains, generate streaming, and enrich in‐droplet microparticles. This research is anticipated to facilitate the development of embeddable wireless on‐chip flow generators, wearable sensors with liquid sample processing functions, and implantable devices with flow generation and acoustic stimulation abilities for engineering, veterinary, and biomedical applications.

Li, Jiali↗

Multiplex growth rate phenotyping of synthetic mutants in selection to engineer glucose and xylose co‐utilization in Escherichia coli

ABSTRACT Engineering the simultaneous consumption of glucose and xylose sugars is critical to enable the sustainable production of biofuels from lignocellulosic biomass. In most major industrial microorganisms glucose completely inhibits the uptake of xylose, limiting efficient sugar mixture conversion. In E . coli removal of the major glucose transporter PTS allows for glucose and xylose co‐consumption but only after prolonged adaptation, which is an effective process but hard to control and prone to co‐evolving undesired traits. Here we synthetically engineer mutants to target sugar co‐consumption properties; we subject a PTS − mutant to a short adaptive step and subsequently either delete or overexpress key genes previously suggested to affect sugar consumption. Screening the co‐consumption properties of these mutants individually is very laborious. We show we can evaluate sugar co‐consumption properties in parallel by culturing the mutants in selection and applying a novel approach that computes mutant growth rates in selection using chromosomal barcode counts obtained from Next‐Generation Sequencing. We validate this multiplex growth rate phenotyping approach with individual mutant pure cultures, identify new instances of mutants cross‐feeding on metabolic byproducts, and, importantly, find that the rates of glucose and xylose co‐consumption can be tuned by altering glucokinase expression in our PTS − background. Biotechnol. Bioeng. 2017;114: 885–893. © 2016 Wiley Periodicals, Inc.

Groot, Joost↗

Development of a Massive, Highly Multiplexible, Phonon-Mediated Particle Detector Using Kinetic Inductance Detectors

Here, we present a status update on the development of a phonon-mediated particle detector using kinetic inductance detector (KID). The design is intended for \(\mathscr {O}(1)\) kg substrate, using \(\mathscr {O}(10^{2})\) KIDs on a single readout line, to image the athermal phonon distribution at < 1 mm position resolution and \(\mathscr {O}(10)\) eV energy resolution. The design specification is set by the need to improve position reconstruction fidelity while maintaining low energy threshold for future rare-event searches such as for low-mass dark matter. Furthermore, we report on the design, which shows negligible crosstalk and > 95% inductor current uniformity, using the coplanar waveguide feedline, ground shield, and a new class of KIDs with symmetric coplanar stripline (sCPS) inductor. The multiplexing is designed upon the frequency-geometry relation we develop for the sCPS KIDs. We introduce the fabrications of the Nb RF assessment prototypes and the high phonon collection efficiency Al–Nb devices. We achieve \(\lesssim \) 0.07% frequency displacement on a 80-KID RF assessment prototype, and the result indicates that we may place more than 180 resonances in our 0.4 GHz readout band with minimal frequency misordering. The coupling quality factors are \(\sim \) 10 \(^{5}\) as designed. Finally, we update our work in progress in fabricating the \(\mathscr {O}(10^{2})\) KID, bi-material, \(\mathscr {O}(1)\) kg detectors, and the expected position and energy resolutions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Signatures of Thermal and Electrical Crosstalk in a Microwave Multiplexed Hard X-ray Transition Edge Sensor Array

We investigate the crosstalk between Transition-Edge Sensor (TES) pixels in a 24-pixel hard X-ray spectrometer array fabricated at the Advanced Photon Source, Argonne National Laboratory. Analysis shows thermal cross talk, possibly associated with insufficient thermalization, and rare but larger in magnitude electrical crosstalk between specific perpetrator-victim pixel combinations, potentially due to defects in the bias wiring or microwave multiplexing circuit. We use a method based on group-triggering and averaging to isolate the crosstalk response despite only having access to X-ray photon illumination uniform across the entire array. This allows us to identify thermal and electrical crosstalk between pixel pairs in repeated measurements to the level of 1 part in 1000 or better. In the array under study, the magnitude of observed crosstalk is small but comparable to the resolving power of this pixel design (E/Delta E similar to\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$E/\Delta {}E \sim$$\end{document} 1000 at 20 keV) and so potentially responsible for a degradation in energy resolution of the array at high incident photon rates. Having proven the methods to identify and quantify crosstalk in our setup, we can now consider mitigations.

Triamkitsawat, Panthita↗

Suppression of four-wave mixing in a 22 × 10 Gbps dense wavelength division multiplexed system by linearly chirped fiber Bragg gratings

A scheme comprising two linearly chirped fiber Bragg gratings (LCFBGs) is proposed to suppress four-wave mixing (FWM) effects in a 22×10 Gbps dense wavelength division multiplexed (DWDM) system employing dispersion shifted fiber with 0.2 nm channel spacing. The FWM reduction in our proposed scheme has been studied by varying the input signal power per channel from − 2 to + 10 dBm. The parameters of LCFBGs are optimized to obtain a maximum quality factor for all 22 channels. The proposed method is effective even at high input power (10 dBm) and provides a simple, cost effective way to improve the transmission performance in DWDM system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Minimum shift keying based protection mode capable wavelength division multiplexed passive optical network optical overlay system

We explored the functioning of an optical overlay of multicast and unicast data streams on a survival wavelength division multiplexed passive optical network using intensity and minimum shift keying modulation for both single and multiuser. In optical line terminal, using a sinusoidal clock, optical subcarriers are generated not only to carry the multicast and unicast data streams simultaneously but also in case of fiber failure, protection mode is enabled to carry the data streams smoothly. Here, 10 Gbps downstream multicast in normal mode and unicast signals both in normal and protection mode are transmitted error-free through 30 km dispersion shifted fiber. In both the cases 10 Gbps upstream signal is modulated and sent back to the optical line terminal. For single user nearly similar power penalty is witnessed for downstream unicast as well as re-modulated upstream data in both the conditions and also when multicast data is disabled. The power penalties between single and multiuser for both the modes are found to be approximately 0.06, 0.42 and 0.7 dB for unicast MSK, multicast and upstream respectively.

36 MATERIALS SCIENCE↗

Trace double-component gas sensor in photoacoustic spectroscopy based on frequency division multiplexing

In this paper, we demonstrated a trace double-component gas detection system based on frequency division multiplexing using two-way distributed feedback laser diode (DFB-LD) as the excitation laser source. In the frequency response range of photoacoustic spectroscopy (PAS) cell, this detection system could detect the second harmonics of different frequencies f{sub 0} and f{sub 1}, which were excited by the gas absorption using the two wavelengths of DFB-LD at modulation frequencies f{sub 0}/2 and f{sub 1}/2. Unlike previous double-component gas sensor, these two DFB-LDs connected into the both ends of PAS cell without optical fiber coupler could effectively improve the excited light intensity and simplify the system structure. This feature allowed the trace detection of double-component gas of mixed-methane (CH{sub 4}) and water (H{sub 2}O) vapor with a low detection limits 11.055 ppm and 885 ppb, respectively. Additionally, the linear responses to the gas concentration were achieved 0.9986 and 0.9997, and it exhibited potentially as an effective detection system for complex gas component.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhancing capacity of optical links using polarization multiplexing

5G mobile networks targets wireless connection capacity up to 10 Gb/s. For this purpose, we propose a method to considerably increase capacity. In this paper first, we show how to compensate the effects of polarization mode dispersion (PMD) in systems with double polarizations where PMD in such systems could cause fluctuations in optical transmission due to crosstalk and cross phase modulation. Second, we show how to enhance system capacity benefiting from polarization multiplexing (POL-MUX) technique which can provide double bandwidth efficiency. Based on the simulation results, we have achieved optimum system performance and we were able to reduce the PMD effect using pre- and post-compensation. We also have improved the POL-MUX technique using coherent detection in case of 16/64 QAM modulations. The results were achieved by implementing polarization controllers, polarization beam combiners and splitters, as well as polarization phase shifters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Profiling of bioactive lipids in different dendritic cell subsets using an improved multiplex quantitative LC-MS/MS method

Highlights: • We improved a LC-MS/MS method to measure many mediators simultaneously. • Conventional DCs produce inflammatory lipids (leukotrienes) preferentially. • RA-DCs produce PGI{sub 2}, PGE{sub 2}, and TXA{sub 2} preferentially. Lipids are an energy source and key components of the cell membrane; however, they are also bioactive mediators of physiological and pathophysiological phenomena. Quantification of bioactive lipids is not easy because they have diverse chemical properties and are present in trace amounts. Here, we improved a multiplex method of quantifying bioactive lipids, thereby enabling measurement of 90 compounds simultaneously. We then used this system to quantify bioactive lipids produced by two subsets of dendritic cells (DCs): all-trans retinoic acid-treated DCs (RA-DCs) (a type of tolerogenic DC (tDC)) and conventional DCs (cDCs). We found that cDCs produced inflammatory lipid mediators such as leukotrienes, whereas RA-DCs produced anti-inflammatory lipid mediators such as prostaglandin I{sub 2}. Consistent with this, cDCs expressed larger amounts of mRNA encoding 5-lipoxygenase and LTA{sub 4} hydrolase (both responsible for leukotriene biosynthesis) and RA-DCs produced larger amounts of mRNA encoding prostaglandin I{sub 2} synthase. Taken together, the results suggest that the method is useful for clarifying the roles of bioactive lipids during immune responses.

60 APPLIED LIFE SCIENCES↗

Prediction of Response to Preoperative Chemoradiotherapy in Rectal Cancer by Multiplex Kinase Activity Profiling

Purpose: Tumor response of rectal cancer to preoperative chemoradiotherapy (CRT) varies considerably. In experimental tumor models and clinical radiotherapy, activity of particular subsets of kinase signaling pathways seems to predict radiation response. This study aimed to determine whether tumor kinase activity profiles might predict tumor response to preoperative CRT in locally advanced rectal cancer (LARC). Methods and Materials: Sixty-seven LARC patients were treated with a CRT regimen consisting of radiotherapy, fluorouracil, and, where possible, oxaliplatin. Pretreatment tumor biopsy specimens were analyzed using microarrays with kinase substrates, and the resulting substrate phosphorylation patterns were correlated with tumor response to preoperative treatment as assessed by histomorphologic tumor regression grade (TRG). A predictive model for TRG scores from phosphosubstrate signatures was obtained by partial-least-squares discriminant analysis. Prediction performance was evaluated by leave-one-out cross-validation and use of an independent test set. Results: In the patient population, 73% and 15% were scored as good responders (TRG 1-2) or intermediate responders (TRG 3), whereas 12% were assessed as poor responders (TRG 4-5). In a subset of 7 poor responders and 12 good responders, treatment outcome was correctly predicted for 95%. Application of the prediction model on the remaining patient samples resulted in correct prediction for 85%. Phosphosubstrate signatures generated by poor-responding tumors indicated high kinase activity, which was inhibited by the kinase inhibitor sunitinib, and several discriminating phosphosubstrates represented proteins derived from signaling pathways implicated in radioresistance. Conclusions: Multiplex kinase activity profiling may identify functional biomarkers predictive of tumor response to preoperative CRT in LARC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte–Carlo ray-tracing studies of multiplexed prismatic graphite analyzers for the cold-neutron triple-axis spectrometer at the High Flux Isotope Reactor

A modern cold triple-axis spectrometer to study quantum condensed matter systems is planned for the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. Here, we describe the conceptual principles and design of a secondary spectrometer using a multiplexed, prismatic analyzer system relying on graphite crystals and inspired by the successful implementation of the Continuous Angle Multiple Energy Analysis (CAMEA) spectrometers at the Paul Scherrer Institute. This project is currently known as MANTA for Multi-Analyzer Neutron Triple-Axis. Here, we report Monte-Carlo ray-tracing simulations on a simple but realistic sample scattering kernel to further illustrate the prismatic analyzer concept’s workings, calibration, and performance. Then, we introduce a new statistical analysis approach based on the prismatic analyzer concept to improve the number of final energies measured on the spectrometer. We also study possible evolutions in the CAMEA design relevant for MANTA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and development of a probe-based multiplexed multi-species absorption spectroscopy sensor for characterizing transient gas-parameter distributions in the intake systems of I.C. engines

We designed and developed a 4-probe multiplexed multi-species absorption spectroscopy sensor system for gas property measurements on the intake side of commercial multi-cylinder internal-combustion (I.C.) engines; the resulting cycle- and cylinder-resolved concentration, temperature and pressure measurements are applicable for assessing spatial and temporal variations in the recirculated exhaust gas (EGR) distribution at various locations along the intake gas path, which in turn is relevant to assessing cylinder charge uniformity, control strategies, and CFD models. Furthermore, the diagnostic is based on absorption spectroscopy and includes an H 2 O absorption system (utilizing a 1.39 m distributed feedback (DFB) diode laser) for measuring gas temperature, pressure, and H 2 O concentration, and a CO 2 absorption system (utilizing a 2.7 m DFB laser) for measuring CO 2 concentration. The various lasers, optical components and detectors were housed in an instrument box, and the 1.39- m and 2.7- m lasers were guided to and from the engine-mounted probes via optical fibers and hollow waveguides, respectively. The 5kHz measurement bandwidth allows for near-crank angle resolved measurements, with a resolution of 1.2 crank angle degrees at 1000 RPM. Our use of compact stainless steel measurement probes enables simultaneous multi-point measurements at various locations on the engine with minimal changes to the base engine hardware; in addition to resolving large-scale spatial variations via simultaneous multi-probe measurements, local spatial gradients can be resolved by translating individual probes. Along with details of various sensor design features and performance, we also demonstrate validation of the spectral parameters of the associated CO 2 absorption transitions using both a multi-pass heated cell and the sensor probes.

33 ADVANCED PROPULSION SYSTEMS↗

A quantitative multiplex nuclease protection assay reveals immunotoxicity gene expression profiles in the rabbit model for vaginal drug safety evaluation

Any vaginal product that alters the mucosal environment and impairs the immune barrier increases the risk of sexually transmitted infections, especially HIV infection, which thrives on mucosal damage and inflammation. The FDA-recommended rabbit vaginal irritation (RVI) model serves as a first line selection tool for vaginal products; however, for decades it has been limited to histopathology scoring, insufficient to select safe anti-HIV microbicides. In this study we incorporate to the RVI model a novel quantitative nuclease protection assay (qNPA) to quantify mRNA levels of 25 genes representing leukocyte differentiation markers, toll-like receptors (TLR), cytokines, chemokines, epithelial repair, microbicidal and vascular markers, by designing two multiplex arrays. Tissue sections were obtained from 36 rabbits (6 per treatment arm) after 14 daily applications of a placebo gel, saline, 4% nonoxynol-9 (N-9), and three combinations of the anti-HIV microbicides tenofovir (TFV) and UC781 in escalating concentrations (highest: 10% TFV + 2.5%UC781). Results showed that increased expression levels of toll-like receptor (TLR)-4, interleukin (IL)-1β, CXCL8, epithelial membrane protein (EMP)-1 (P < 0.05), and decreased levels of TLR2 (P < 0.05), TLR3 and bactericidal permeability increasing protein (BPI) (P < 0.001) were associated with cervicovaginal mucosal alteration (histopathology). Seven markers showed a significant linear trend predicting epithelial damage (up with CD4, IL-1β, CXCL8, CCL2, CCL21, EMP1 and down with BPI). Despite the low tissue damage RVI scores, the high-dose microbicide combination gel caused activation of HIV host cells (SLC and CD4) while N-9 caused proinflammatory gene upregulation (IL-8 and TLR4) suggesting a potential for increasing risk of HIV via different mechanisms depending on the chemical nature of the test product. - Highlights: • A transcriptome nuclease protection assay assessed microbicides for vaginal safety. • Biomarkers were correlated with histopathology in paraffin-embedded rabbit tissues. • Compounds differed by effects on putative pathways of increased risk of HIV. • Nonsoxynol-9 caused inflammatory tissue damage involving TLR4 and IL-8. • An antiretroviral combination stimulated immune cells evidenced by SLC and CD4.

60 APPLIED LIFE SCIENCES↗

Multiplexed Electrochemical Immunoassay of Phosphorylated Proteins Based on Enzyme-Functionalized Gold Nanorod Labels and Electric Field-Driven Acceleration

A multiplexed electrochemical immunoassay integrating enzyme amplification and electric field-driven strategy was developed for fast and sensitive quantification of phosphorylated p53 at Ser392 (phospho-p53 392), Ser15 (phospho-p53 15), Ser46 (phospho-p53 46) and total p53 simultaneously. The disposable sensor array has four spatially separated working electrodes and each of them is modified with different capture antibody, which enables simultaneous immunoassay to be conducted without cross-talk between adjacent electrodes. The enhanced sensitivity was achieved by multi-enzymes amplification strategy using gold nanorods (AuNRs) as nanocarrier for co-immobilization of horseradish peroxidase (HRP) and detection antibody (Ab2) at high ratio of HRP/Ab2, which produced an amplified electrocatalytic response by the reduction of HRP oxidized thionine in the presence of hydrogen peroxide. The immunoreaction processes were accelerated by applying +0.4 V for 3 min and then -0.2 V for 1.5 min, thus the whole sandwich immunoreactions could be completed in less than 5 min. The disposable immunosensor array shows excellent promise for clinical screening of phosphorylated proteins and convenient point-of-care diagnostics.

59 BASIC BIOLOGICAL SCIENCES↗

Internal Standard Triggered-Parallel Reaction Monitoring Mass Spectrometry Enables Multiplexed Quantification of Candidate Biomarkers in Plasma

Despite advances in proteomic technologies, clinical translation of plasma biomarkers remains low, partly due to a major bottleneck between the discovery of candidate biomarkers and costly clinical validation studies. Due to a dearth of multiplexable assays, generally only a few candidate biomarkers are tested, and the validation success rate is accordingly low. Previously, mass spectrometry-based approaches have been used to fill this gap but feature poor quantitative performance and were generally limited to hundreds of proteins. Here, we demonstrate the capability of an internal standard triggered-parallel reaction monitoring (IS-PRM) assay to greatly expand the numbers of candidates that can be tested with improved quantitative performance. The assay couples immunodepletion and fractionation with IS-PRM and was developed and implemented in human plasma to quantify 5176 peptides representing 1314 breast cancer biomarker candidates. Characterization of the IS-PRM assay demonstrated the precision (median % CV of 7.7%), linearity (median R 2 > 0.999 over 4 orders of magnitude), and sensitivity (median LLOQ < 1 fmol, approximately) to enable rank-ordering of candidate biomarkers for validation studies. Using three plasma pools from breast cancer patients and three control pools, 893 proteins were quantified, of which 162 candidate biomarkers were verified in at least one of the cancer pools and 22 were verified in all three cancer pools. The assay greatly expands capabilities for quantification of large numbers of proteins and is well suited for prioritization of viable candidate biomarkers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗