Search NASA⌕ Search

SEARCH · Search NASA

Results for “net present value”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Commercial, industrial, and institutional discount rate estimation for efficiency standards analysis: Sector-level data 1998–2022

Underlying each of the U.S. Department of Energy’s (DOE’s) federal appliance and equipment energy conservation standards are a set of complex analyses of the projected costs and benefits of regulation. Any new or amended standard must be designed to achieve significant additional energy conservation, provided that it is technologically feasible and economically justified (42 U.S.C. 6295(o)(2)(A)). DOE determines economic justification based on whether the benefits exceed the burdens, considering a variety of factors, including the economic impact of the standard on consumers of the product and the savings in lifetime operating cost compared to any increase in price or maintenance expenses (42 U.S.C. 6295(o)(2)(B)). As part of this determination, DOE conducts a life-cycle cost (LCC) analysis, which models the combined impact of appliance first cost and operating cost changes on a representative commercial building sample to identify the fraction of customers achieving LCC savings or incurring net cost at the considered efficiency levels. Thus, the commercial discount rate value(s) used to calculate the present value of energy cost savings within the LCC model implicitly plays a role in estimating the economic impact of potential standard levels. This report provides an in-depth discussion of the commercial discount rate estimation process. It is an update to previous reports on estimating commercial discount rates from firm-level and sector-level financial data (e.g., Fujita, 2021, 2016). Major topics covered in this report include the following: -Discount rate estimation methods and rationale -Data sources used and data limitations -Discount rate distributions for use in standards analysis -Discount rate estimation methods and distributions specific to the small business subgroup analysis A version of this analysis was most recently released in 2022. Going forward, this report will be updated as data allow and analyses necessitate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial, industrial, and institutional discount rate estimation for efficiency standards analysis: Sector-level data 1998–2023

Underlying each of the U.S. Department of Energy’s (DOE’s) federal appliance and equipment energy conservation standards are a set of complex analyses of the projected costs and benefits of regulation. Any new or amended standard must be designed to achieve significant additional energy conservation, provided that it is technologically feasible and economically justified (42 U.S.C. 6295(o)(2)(A)). DOE determines economic justification based on whether the benefits exceed the burdens, considering a variety of factors, including the economic impact of the standard on consumers of the product and the savings in lifetime operating cost compared to any increase in price or maintenance expenses (42 U.S.C. 6295(o)(2)(B)). As part of this determination, DOE conducts a life-cycle cost (LCC) analysis, which models the combined impact of appliance first cost and operating cost changes on a representative commercial building sample to identify the fraction of customers achieving LCC savings or incurring net cost at the considered efficiency levels. Thus, the commercial discount rate value(s) used to calculate the present value of energy cost savings within the LCC model implicitly plays a role in estimating the economic impact of potential standard levels. This report provides an in-depth discussion of the commercial discount rate estimation process relying on the Capital Asset Pricing Model (CAPM) to estimate a business’ cost of equity, and by adding a risk adjustment factor to the risk-free rate associated with long-term U.S. Treasury bonds to estimate their cost of debt. It is an update to previous reports on estimating commercial discount rates from firm-level and sector-level financial data (e.g., Fujita, 2021, 2016). Major topics covered in this report include the following: • Discount rate estimation methods and rationale • Data sources used and data limitations • Discount rate distributions for use in standards analysis • Discount rate estimation methods and distributions specific to the small business subgroup analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiation exchange for a system with partially transmitting wall

An approach is presented for applying the net radiation method developed by Siegel and Howell (1972) and Sparrow and Cess (1966) to systems involving opaque and partially transmitting walls. The results obtained from the basic equations for various values of plate emissivities and temperatures are presented in graphs. Attention is given to the window temperature relative to the temperature of the hot wall and the heat transferred relative to that transferred without the window.

Hussain, N. A.↗

Learning fuzzy information in a hybrid connectionist, symbolic model

An instance-based learning system is presented. SC-net is a fuzzy hybrid connectionist, symbolic learning system. It remembers some examples and makes groups of examples into exemplars. All real-valued attributes are represented as fuzzy sets. The network representation and learning method is described. To illustrate this approach to learning in fuzzy domains, an example of segmenting magnetic resonance images of the brain is discussed. Clearly, the boundaries between human tissues are ill-defined or fuzzy. Example fuzzy rules for recognition are generated. Segmentations are presented that provide results that radiologists find useful.

Romaniuk, Steve G.↗

Kinetic model-based group contribution method for derived cetane number prediction of oxygenated fuel components and blends

A four-step autoignition model was used to derive an expression for the ignition delay (ID) measured in ignition quality testers (IQT) with the derived cetane number (DCN) determined from this ID using the ASTM D6890 standard correlation. The model predicts DCN for individual compounds and blends as a function of each compound's global initiation and net chain branching rate constants. Expressions for these values were determined assuming they could be related to the functional groups present in each compound. Measurement data for 125 compounds and 94 binary and ternary blends (including oxygenates: alcohols, aldehydes, esters, ethers, and ketones), from literature and from measurements performed in our lab, were used to obtain the dependence of the measured ignition delay on each functional group. The new kinetic model-based group contribution method was able to predict the ignition delay of both pure compounds and blends, with an average DCN error of 4.4 (19%) and 2.8 (11%), respectively. Here, the blend model was also used to develop an ID mixing rule by incorporating existing IQT ignition delay data for each compound. Use of the mixing rule gave an average DCN error of 3.6 (16%) for blends. Both the blend model and mixing rule were found to be superior compared to standard linear by volume fraction or mole fraction mixing rules commonly used to estimate the DCN of mixtures.

42 ENGINEERING↗

Handbook of the Radiation Regime of the Arctic Basin: Results from the Drift Stations

This Handbook summarizes the radiation data from the Soviet 'North Pole' drifting research stations operated in the Arctic from 1950 to 1991. The Handbook contains reduced mean monthly values of the fluxes of solar radiation for solar elevations up to 35 deg at 5 deg intervals, monthly totals of the net radiation and its constituents, and mean monthly values of the albedo of the sea-ice surfaces. The Handbook presents information of interest to specialists studying the physics of the atmosphere, climatology, geography, and related disciplines.

Mishin, A. A.↗

Simple Autoignition Model for the Derived Cetane Number of Oxygenated Compounds and Fuel Blends

A simple four-step autoignition model was used to derive an expression for the ignition delay and derived cetane number (DCN) measured by ignition quality testers (IQT) for oxygenated compounds and blends as a function of each compound’s global initiation and net chain branching rate constants. Expressions for these values were determined assuming they could be related to the functional groups present in a given compound. Measurements for 124 compounds and 94 binary and ternary blends, gathered from the literature and performed at UW-Madison, were used to obtain the explicit dependence of the measured ignition delay on each functional group. The new model was able to successfully describe the ignition behavior of both the compounds and blends, with an average DCN error of 5.0 (22%) and 3.5 (15%), respectively. Additionally, the blend model could naturally be modified into a mixing rule by incorporating existing IQT ignition delay data for each compound. Use of the mixing rule was found to offer improvements over the full prediction, with an average DCN error of 3.2 (14%).

09 BIOMASS FUELS↗

Simple Autoignition Model for the Derived Cetane Number of Oxygenated Compounds and Fuel Blends

A four-step autoignition model was used to derive an expression for the ignition delay and derived cetane number (DCN) measured by ignition quality testers (IQT) for oxygenated compounds and blends as a function of each compound’s global initiation and net chain branching rate constants. Expressions for these values were determined assuming they could be related to the functional groups present in a compound. Measurements for 124 compounds and 94 binary and ternary blends, gathered from the literature and performed at UW-Madison, were used to obtain the dependence of the measured ignition delay on each functional group. The new model was able to describe the ignition behavior of both the compounds and blends, with an average DCN error of 5.0 (22%) and 3.5 (15%), respectively. Additionally, the blend model was transformed into a mixing rule by incorporating existing IQT ignition delay data for each compound. Use of the mixing rule was found to offer improvements over the full prediction, with an average DCN error of 3.2 (14%).

Witkowski, Dustin↗

Partitioning Stakeholders for the Economic Valuation of Ecosystem Services: Examples of a Mangrove System

Although the importance of ecosystem services provided by natural forests, especially mangroves, is well known, the destruction of these environments is still ubiquitous and therefore protection measures are urgently needed. The present study compares the current approach of economic valuation of ecosystem services to a proposed one, using a study case of a mangrove system as an example. We suggest that a cost-benefit analysis for economically valuing environmental services should be performed with three additional modifications consisting of (i) a categorization of local stakeholders as demanders of particular ecosystem services, (ii) acknowledgement of the government as one of these demander groups, and (iii) the inclusion of opportunity costs in the valuation. The application of this approach to the mangrove area in the east portion of Great Abaco Island, the Bahamas, reveals that not only the ecosystem services received differ between demander groups, but the monetary benefits and costs are also specific to each of these groups. We show that the economic valuation of the ecosystem should be differentiated for each category, instead of being calculated as a net ‘societal value’ as it is currently. Applying this categorization of demanders enables a better understanding of the cost and benefit structure of the protection of a natural area. The present paper aims to facilitate discussions regarding benefit and cost sharing related to the protection of natural areas.

54 ENVIRONMENTAL SCIENCES↗

FINAL TECHNICAL AND ECONOMIC FEASIBILITY STUDY ON THE APPLICATION OF A HEAT INTEGRATED POST-COMBUSTION CO2 CAPTURE SYSTEM WITH HITACHI ADVANCED SOLVENT INTO EXISTING COAL-FIRED POWER PLANT

This report contains the results of a techno-economic assessment (TEA) conducted of a heat integrated post-combustion CO2 capture process with Hitachi advanced solvent for retrofit into an existing coal-fired power plant (but treated as greenfield plant on cost analysis). The process has been developed by the University of Kentucky Center for Applied Energy (UK CAER). EPRI was chiefly responsible for this analysis, with significant input from WorleyParsons, Hitachi Power Systems America (Hitachi) and UK CAER. The project also involves the design, fabrication, installation, testing, and analyses of a slipstream facility located at L&GE-KU’s E.W. Brown Generating Station to demonstrate the UK CAER carbon capture system that could utilize heat integration with the main power plant. The design, start-up, and baseline of the pilot system was performed with a generic 30 wt% MEA solvent to obtain data for direct comparison with the DOE/NETL Reference Case followed by testing Hitachi’s proprietary solvent H3-1. In this techno-economic analysis, two cases utilizing the UK CAER process are compared, using different approach temperatures and solvent, against the DOE/NETL Reference Case (Case 10). The results are shown comparing the energy demand for post-combustion CO2 capture and the net higher heating value (HHV) efficiency of the power plant integrated with the post-combustion capture (PCC) plant. A levelized cost of electricity (LCOE) assessment was performed showing the costs of the options presented in the study. The key factors contributing to the reduction of LCOE were identified as CO2 partial pressure increase at the flue gas inlet, thermal integration of the process, and performance of the Hitachi H3-1 solvent. Recent UK CAER process pilot-scale testing data and process simualtion data showed that the packing heights of absorber and stripper columns were significantly oversized in the prelimanary TEA (Task 2 of this project) and thus updated in this final TEA for the H3-1 case only. In addition, the solvent make-up cost for H3-1 was updated based on lattest test results. Finally, a heat integration with the main power plant was applied in this final TEA to increase overall energy effciency for both the MEA and H3-1 cases. Additonal reductions in capital and operational costs are expected but not taken into account here. Shorter columns result in reduced pressure drops, smaller blower head and pump hydraulic head requirements. An increase in overall energy efficiency resuls in a decreased size of the power plant, the CCS and a reduced parasitic steam requirement to the CCS. The net efficiency of the UK CAER integrated PC power plant with CO2 capture changes from 26.2% for the Reference Case 10 plant in 2010 revised DOE/NETL baseline report to 27.6% for the MEA options considered, and 29.1% for the options utilizing the Hitachi advanced solvent. The UK CAER Process + Hitachi case also produces an extra 30.9 MW of generation compared to the UK CAER Process + MEA case and total 60.9 MW more than DOE Case 10. LCOE ($/MWh) values are $172.08/MWh for the MEA option and $157.65/MWh for the Hitachi H3-1 solvent cases considered in comparison to $189.59/MWh in January 2012 dollar for the Reference Case 10. The UK CAER CCS process with MEA case lowers energy consumption for CO2 capture to 1340 Btu/lb-CO2 captured as compared to 1540 Btu/lb-CO2 in the Reference Case 10. The UK CAER CCS process with H3-1 case further lowers energy consumption for CO2 capture to 973 Btu/lb-CO2 captured, for an advantage of 36.8% less energy consumption than Case 10. The study also shows 38.1% less heat rejection associated with the carbon capture system from 3398 MBtu/hr (Case 10) to 2104 MBtu/hr for the UK CAER + MEA system. Heat rejection is reduced to 2464 MBtu/hr in the UK CAER + H3-1 case, for a 27.5 % decrease compared to Case 10. Modeling outputs show that in the UK CAER process, the cooling water that is 2-5°C cooler than conventional cooling tower water can be achieved for ambient conditions common to the midwest and other regions. The results from the techno-economic assessment show that the proposed technology can be investigated further as a viable alternative to conventional CO2 capture technology. The evaluation also shows the effect of the critical parameters on the LCOE, with the main variables being the approach temperature and CO2 partial pressure increase at the flue gas inlet. A summary of the key advantages of the UK CAER Process + H3-1 case for LCOE and other economic factors compared to the DOE Case 10 is as follows: • A lower variable operating cost by $1.56/MWh ($1.08MWh less than the UK CAER Process + MEA Case), a 11.7% reduction compared to the DOE Case 10 • A lower COE by $25.32MWh ($13.94/MWh lower than the UK CAER Process + MEA Case), a 16.9% reduction compared to the DOE Case 10 • A lower LCOE by $31.94/MWh ($17.51/MWh lower than the UK CAER Process + MEA Case), a 16.9% reduction compared to the DOE Case 10 • A lower cost of CO2 captured by $18.65/tonne CO2 ($9.44/tonne CO2 lower than the UK CAER Process + MEA Case), a 30.4% reduction compared to the DOE Case 10 • A lower cost of CO2 avoided by $34.95/tonne CO2 ($18.53 tonne CO2 lower than the UK CAER Process + MEA Case), a 38.7% reduction compared to the DOE Case 10

Bhown, Abhoyjit S.↗

Dosimetric evaluation of new approaches in GRID therapy using nonconventional radiation sources

Purpose: Spatial fractionation of the dose has proven to be a promising approach to increase the tolerance of healthy tissue, which is the main limitation of radiotherapy. A good example of that is GRID therapy, which has been successfully used in the management of large tumors with low toxicity. The aim of this work is to explore new avenues using nonconventional sources: GRID therapy by using kilovoltage (synchrotron) x-rays, the use of very high-energy electrons, and proton GRID therapy. They share in common the use of the smallest possible grid sizes in order to exploit the dose–volume effects. Methods: Monte Carlo simulations (PENELOPE/PENEASY and GEANT4/GATE codes) were used as a method to study dose distributions resulting from irradiations in different configurations of the three proposed techniques. As figure of merit, percentage (peak and valley) depth dose curves, penumbras, and central peak-to-valley dose ratios (PVDR) were evaluated. As shown in previous biological experiments, high PVDR values are requested for healthy tissue sparing. A superior tumor control may benefit from a lower PVDR. Results: High PVDR values were obtained in the healthy tissue for the three cases studied. When low energy photons are used, the treatment of deep-seated tumors can still be performed with submillimetric grid sizes. Superior PVDR values were reached with the other two approaches in the first centimeters along the beam path. The use of protons has the advantage of delivering a uniform dose distribution in the tumor, while healthy tissue benefits from the spatial fractionation of the dose. In the three evaluated techniques, there is a net reduction in penumbra with respect to radiosurgery. Conclusions: The high PVDR values in the healthy tissue and the use of small grid sizes in the three presented approaches might constitute a promising alternative to treat tumors with such spatially fractionated radiotherapy techniques. The dosimetric results presented here support the interest of performing radiobiology experiments in order to evaluate these new avenues.

07 ISOTOPE AND RADIATION SOURCES↗

Performance seeking controls

A performance logic algorithm (PSL) was developed to optimize the performance of propulsion systems for component and sensor degradations by monitoring the performance of the engine system and minimizing thrust specific fuel consumption (TSFC) while retaining a constant engine net thrust. Engine constraints such as surge margin, speed, pressure, and temperature are observed. The PSL algorithm was applied to the quiet, clean, short haul experimental engine. Engine control set points were modified for component degradations in order to restore the nominal net thrust. Results show convergence to the optimum value can be obtained within 60 to 90 seconds, which makes the program acceptable to on line operation with present state of the art minicomputers. Tests indicate that in most cases the PSL algorithm offers some improvement in thrust specific fuel consumption over the manual throttle.

Seldner, K.↗

Smooth Phase Interpolated Keying

Smooth phase interpolated keying (SPIK) is an improved method of computing smooth phase-modulation waveforms for radio communication systems that convey digital information. SPIK is applicable to a variety of phase-shift-keying (PSK) modulation schemes, including quaternary PSK (QPSK), octonary PSK (8PSK), and 16PSK. In comparison with a related prior method, SPIK offers advantages of better performance and less complexity of implementation. In a PSK scheme, the underlying information waveform that one seeks to convey consists of discrete rectangular steps, but the spectral width of such a waveform is excessive for practical radio communication. Therefore, the problem is to smooth the step phase waveform in such a manner as to maintain power and bandwidth efficiency without incurring an unacceptably large error rate and without introducing undesired variations in the amplitude of the affected radio signal. Although the ideal constellation of PSK phasor points does not cause amplitude variations, filtering of the modulation waveform (in which, typically, a rectangular pulse is converted to a square-root raised cosine pulse) causes amplitude fluctuations. If a power-efficient nonlinear amplifier is used in the radio communication system, the fluctuating-amplitude signal can undergo significant spectral regrowth, thus compromising the bandwidth efficiency of the system. In the related prior method, one seeks to solve the problem in a procedure that comprises two major steps: phase-value generation and phase interpolation. SPIK follows the two-step approach of the related prior method, but the details of the steps are different. In the phase-value-generation step, the phase values of symbols in the PSK constellation are determined by a phase function that is said to be maximally smooth and that is chosen to minimize the spectral spread of the modulated signal. In this step, the constellation is divided into two groups by assigning, to information symbols, phase values that result in equal numbers of clockwise and counter-clockwise phase rotations for equally likely symbols. The purpose served by assigning phase values in this way is to prevent unnecessary generation of spectral lines and prevent net shifts of the carrier signal. In the phase-interpolation step, the smooth phase values are interpolated over a number, n, of consecutive symbols (including the present symbol) by means of an unconventional spline curve fit.

Borah, Deva K.↗

Toward “optimal” integration of terrestrial biosphere models

Multimodel ensembles (MME) are commonplace in Earth system modeling. Here we perform MME integration using a 10-member ensemble of terrestrial biosphere models (TBMs) from the Multiscale synthesis and Terrestrial Model Intercomparison Project (MsTMIP). We contrast optimal (skill based for present-day carbon cycling) versus naive (one model-one vote) integration. MsTMIP optimal and naive mean land sink strength estimates (-1.16 versus -1.15 Pg C per annum respectively) are statistically indistinguishable. This holds also for grid cell values and extends to gross uptake, biomass, and net ecosystem productivity. TBM skill is similarly indistinguishable. The added complexity of skill-based integration does not materially change MME values. This suggests that carbon metabolism has predictability limits and/or that all models and references are misspecified. Finally, resolving this issue requires addressing specific uncertainty types (initial conditions, structure, and references) and a change in model development paradigms currently dominant in the TBM community.

54 ENVIRONMENTAL SCIENCES↗

Quantifying three dimensional reconnection in fragmented current layers

There is growing evidence that when magnetic reconnection occurs in high Lundquist number plasmas such as in the Solar Corona or the Earth's Magnetosphere it does so within a fragmented, rather than a smooth current layer. Within the extent of these fragmented current regions, the associated magnetic flux transfer and energy release occur simultaneously in many different places. This investigation focusses on how best to quantify the rate at which reconnection occurs in such layers. An analytical theory is developed which describes the manner in which new connections form within fragmented current layers in the absence of magnetic nulls. It is shown that the collective rate at which new connections form can be characterized by two measures; a total rate which measures the true rate at which new connections are formed and a net rate which measures the net change of connection associated with the largest value of the integral of E{sub ||} through all of the non-ideal regions. Two simple analytical models are presented which demonstrate how each should be applied and what they quantify.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel low-thermal-budget approach for the co-production of ethylene and hydrogen via the electrochemical non-oxidative deprotonation of ethane

Here, the oversupply of ethane, a major component of natural gas liquids, has stimulated the wide applications of ethylene since the shale gas revolution. However, ethylene production is energy-intensive and represents the most energy-consuming single process in the chemical industry. In this communication, we report, for the first time, a novel low-thermal-budget process for the co-production of ethylene and pure hydrogen using a proton-conducting electrochemical deprotonation cell. At a constant current density of 1 A cm –2 , corresponding to a hydrogen production rate of 0.448 mol cm –2 per day, and 400 °C, a close to 100% ethylene selectivity was achieved under an electrochemical overpotential of 140 mV. Compared to an industrial ethane steam cracker, the electrochemical deprotonation process can achieve a 65% saving in process energy and reduce the carbon footprint by as much as 72% or even more if renewable electricity and heat are used. If the heating value of produced hydrogen is taken into account, the electrochemical deprotonation process actually has a net gain in processing energy. The electrochemical deprotonation process at reduced temperatures in the present study provides a disruptive approach for petrochemical manufacturing, shifting the paradigm from thermal chemical practice to a clean energy regime.

04 OIL SHALES AND TAR SANDS↗

Advanced ion thruster research

A series of experiments conducted on a ring cusp magnetic field ion thruster; in which the anode, cathode and discharge chamber backplate were moved relative to the magnetic cusp; are described. Optimum locations for the anode, cathode and backplate which yield the lowest energy cost per plasma ion and highest extracted ion fraction are identified. The results are discussed in terms of simple physical models. The results of preliminary experiments into the operation of hollow cathodes on nitrogen and xenon over a large pressure range (0.1 to 100 Torr) are presented. They show that the cathode discharge transfers from the cathode insert to the exterior edge of the orifice plate as the interelectrode pressure is increased. Experimental evidence showing that a new ion extractor grid concept can be used to stabilize the plasma sheath at the screen grid is presented. This concept, identified by the term constrained sheath optics, is shown to hold ion beamlet divergence and impingement characteristics to stable values as the beamlet current and the net and total accelerating voltages are changed. The current status of a study of beamlet vectoring induced by displacing the accelerator and/or decelerator grids of a three grid ion extraction system relative to the screen grid is discussed.

Wilbur, P. J.↗

Final Techno-Economic Analysis of 550 MWe Supercritical PC Power Plant CO 2 Capture with Linde-BASF Advanced PCC Technology

This topical report presents the techno-economic evaluation of a 550 MWe supercritical pulverized coal (PC) power plant utilizing Illinois No. 6 coal as fuel, integrated with 1) a previously presented (for a subcritical PC plant) Linde-BASF post-combustion CO 2 capture (PCC) plant incorporating BASF’s OASE® blue aqueous amine-based solvent (LB1) [Ref. 6] and 2) a new Linde-BASF PCC plant incorporating the same BASF OASE® blue solvent that features an advanced stripper interstage heater design (SIH) to optimize heat recovery in the PCC process. The process simulation and modeling for this report is performed using Aspen Plus V8.8. Technical information from the PCC plant is determined using BASF’s proprietary thermodynamic and process simulation models. The simulations developed and resulting cost estimates are first validated by reproducing the results of DOE/NETL Case 12 representing a 550 MWe supercritical PC-fired power plant with PCC incorporating a monoethanolamine (MEA) solvent as used in the DOE/NETL Case 12 reference [Ref. 2]. The results of the techno-economic assessment are shown comparing two specific options utilizing the BASF OASE® blue solvent technology (LB1 and SIH) to the DOE/NETL Case 12 reference. The results are shown comparing the energy demand for PCC, the incremental fuel requirement, and the net higher heating value (HHV) efficiency of the PC power plant integrated with the PCC plant. A comparison of the capital costs for each PCC plant configuration corresponding to a net 550 MWe power generation is also presented. Lastly, a cost of electricity (COE) and cost of CO 2 captured assessment is shown illustrating the substantial cost reductions achieved with the Linde-BASF PCC plant utilizing the advanced SIH configuration in combination with BASF’s OASE® blue solvent technology as compared to the DOE/NETL Case 12 reference. The key factors contributing to the reduction of COE and the cost of CO 2 captured, along with quantification of the magnitude of the reductions achieved by each of these factors, are also discussed. Additionally, a high-level techno-economic analysis of one more highly advanced Linde-BASF PCC configuration case (LB1-CREB) is also presented to demonstrate the significant impact of innovative PCC plant process design improvements on further reducing COE and cost of CO 2 captured for overall plant cost and performance comparison purposes. Overall, the net efficiency of the integrated 550 MWe supercritical PC power plant with CO 2 capture is increased from 28.4% with the DOE/NETL Case 12 reference to 30.9% with the Linde-BASF PCC plant previously presented utilizing the BASF OASE® blue solvent [Ref. 6], and is further increased to 31.4% using Linde-BASF PCC plant with BASF OASE® blue solvent and an advanced SIH configuration. The Linde-BASF PCC plant incorporating the BASF OASE® blue solvent also results in significantly lower overall capital costs, thereby reducing the COE and cost of CO 2 captured from $147.25/MWh and $56.49/MT CO 2 , respectively, for the reference DOE/NETL Case 12 plant, to $128.49/MWh and $41.85/MT CO 2 for process case LB1, respectively, and $126.65/MWh and $40.66/MT CO 2 for process case SIH, respectively. With additional innovative Linde-BASF PCC process configuration improvements, the COE and cost of CO2 captured can be further reduced to $125.51/MWh and $39.90/MT CO 2 for LB1-CREB. Most notably, the Linde-BASF process options presented here have already demonstrated the potential to lower the cost of CO2 captured below the DOE target of $40/MT CO 2 at the 550 MWe scale for second generation PCC technologies.

20 FOSSIL-FUELED POWER PLANTS↗