Search NASA⌕ Search

SEARCH · Search NASA

Results for “neutron techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Hydrogen density mapping in biomolecular crystals through dynamic nuclear polarization

Many fundamental biological processes, including those in photosynthetic reaction centers and enzyme active sites, involve charge and energy transfer, bond cleavage, protonation and hydrogen bonding. Because H atoms play such central roles in these reactions, accurately determining their positions is essential. Yet, conventional X-ray crystallography primarily resolves the heavy atoms in biological structures and provides limited insight into hydrogen, even at atomic resolution. Neutron macromolecular crystallography (NMC) overcomes this limitation by offering exceptional sensitivity to hydrogen and deuterium. Here, we present a theoretical framework for the development of dynamic nuclear polarization NMC (DNP-NMC) techniques, which exploit the alignment of neutron and proton nuclear spins to enhance and tune the hydrogen signal contribution. The DNP-NMC approach advances the resolution of H atoms within biomolecular crystals, whether bound to protein residues or present in solvent. The method establishes key relationships for the coherent structure factor of polarized neutron scattering from hydrogenous matter. It theoretically achieves full accuracy in phase reconstruction and offers a path to improve neutron structure determination, achieving accuracies exceeding ≳80% by incorporating titration states. Using a variant of the hybrid input/output phase-retrieval algorithm, it allows recovery of the hydrogen density with ≳90% phase accuracy. In conclusion, we further discuss sources of experimental uncertainty for the upcoming DNP-enabled, quasi-Laue IMAGINE-X experiment at Oak Ridge National Laboratory's High Flux Isotope Reactor.

dynamic nuclear polarization↗

Cryotrapping peroxide in the active site of human mitochondrial manganese superoxide dismutase crystals for neutron diffraction

Structurally identifying the enzymatic intermediates of redox proteins has been elusive due to difficulty in resolving the H atoms involved in catalysis and the susceptibility of ligand complexes to photoreduction from X-rays. Cryotrapping ligands for neutron protein crystallography combines two powerful tools that offer the advantage of directly identifying hydrogen positions in redox-enzyme intermediates without radiolytic perturbation of metal-containing active sites. However, translating cryogenic techniques from X-ray to neutron crystallography is not straightforward due to the large crystal volumes and long data-collection times. Here, methods have been developed to visualize the evasive peroxo complex of manganese superoxide dismutase (MnSOD) so that all atoms, including H atoms, could be visualized. The subsequent cryocooling and ligand-trapping methods resulted in neutron data collection to 2.30 Å resolution. The P 6 1 22 crystal form of MnSOD is challenging because it has some of the largest unit-cell dimensions ( a = b = 77.8, c = 236.8 Å) ever studied using high-resolution cryo-neutron crystallography. The resulting neutron diffraction data permitted the visualization of a dioxygen species bound to the MnSOD active-site metal that was indicative of successful cryotrapping.

59 BASIC BIOLOGICAL SCIENCES↗

Neutron Characterization of 3D Printed Gas Turbine Alloy With Internal Cooling Structure

The objective of this research work is to investigate the residual strains induced by the presence of a exit hole and internal hollow geometry present in a 3D printed IN718 similar to that seen in a gas turbine blade. The specimens were manufactured with an internal hollow structure that ended with an exit hole, and fabricated by direct metal laser sintering additive manufacturing technique. Using this technique, metal powder was melted by a laser source and rapidly cooled to form the part layer by layer. Rapid heating and cooling generate large thermal gradients and residual stresses in the 3D printed material. To be aligned with industry standards, specimens were heat-treated to relieve most of the residual stresses as well as to investigate whether IN718 still preserved a nonhomogeneous stress state after the thermal treatment. Roughness and microstructure analysis was performed to understand the heat-treated sample properties. To investigate the volumetric residual strain, the neutron diffraction technique was used with a definite neutron wavelength. Bragg’s law was used to determine lattice spacing. Interplanar lattice spacing and stress-free state lattice spacings were measured to calculate the strains. Residual strains were measured in the x and y direction to understand the impact of the presence of a exit hole and internal hollow geometry. The results of volumetric residual strain in the x and y directions showed no significant variations in the distribution of the strain due to the presence of a hollow structure as well as the exit hole. Overall, no significant stress concentration was observed in the heat treated sample. Sample geometry, instrumentation for neutron diffraction, and material properties are discussed in detail in this paper.

Raju, Nandhini↗

New capability for indirect neutron capture measurements: The DICER instrument at LANSCE

The Device for Indirect Capture on Radionuclides (DICER) implements a new indirect technique for (n,γ) studies in which the neutron capture rate is determined from analysis of resonance neutron transmission data. The DICER instrument and associated radionuclide production at the Isotope Production Facility (IPF), both at the Los Alamos Neutron Science Center (LANSCE), as well radioactive sample fabrication, have been under development in the last few years. First measurements on a radioactive sample ( 88 Zr, t ½ =83.4 days), which was recently reported to have an extremely large thermal neutron capture cross section and resonance integral, are planned for the winter of 2021. A performance overview, brief details on the 88Zr fabrication and proof of good operation results will be presented.

47 OTHER INSTRUMENTATION↗

Synthesizing pseudo-Kossel lines from neutron transmission data. II. Validation with neutron diffraction data

A new method to recover the orientation matrix of a single crystal with a known unit cell by analyzing synthesized pseudo-Kossel lines from time-of-flight neutron transmission data has been outlined in a companion article [Dessieux et al. (2023). J. Appl. Cryst. 56, https://dx.doi.org/10.1107/S1600576723001346; referred to here as Article I]. In this work, validation of this new technique is presented by employing experimental neutron transmission and diffraction measurements performed on two copper single-crystal specimens. Time-of-flight spectra were recorded during rotation (ω) of the single crystals about a vertical axis perpendicular to the incident neutron beam. The λ–ω maps recorded in transmission are utilized to determine the crystal orientation with respect to the neutron beam, following the procedure presented in Article I. Further, to validate the indexing procedure, the crystal orientations are compared with those obtained via conventional methods using the diffraction data. The resulting pseudo-Kossel lines across the 2D detectors are also observed for the first time.

36 MATERIALS SCIENCE↗

Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap

The past two decades have yielded several new measurements and reanalysis of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the most precise lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magnetogravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. The new measurement gives a free neutron lifetime of $τ_n$ = 876.3(2.4) stat (0.8) syst . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiplicity counting using organic scintillators to distinguish neutron sources: An advanced teaching laboratory

In this advanced instructional laboratory, students explore complex detection systems and nondestructive assay techniques used in the field of nuclear physics. After setting up and calibrating a neutron detection system, students carry out timing and energy deposition analyses of radiation signals. Through the timing of prompt fission neutron signals, multiplicity counting is used to carry out a special nuclear material (SNM) nondestructive assay. Our experimental setup is comprised of eight trans-stilbene organic scintillation detectors in a well-counter configuration, and measurements are taken on a spontaneous fission source as well as two (α,n) sources. By comparing each source's measured multiplicity distribution, the resulting measurements of the (α,n) sources can be distinguished from that of the spontaneous fission source. Such comparisons prevent the spoofing, i.e., intentional imitation, of a fission source by an (α,n) neutron source. This instructional laboratory is designed for nuclear engineering and physics students interested in organic scintillators, neutron sources, and nonproliferation radiation measurement techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap

The past two decades have yielded several new measurements and reanalysis of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the most precise lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magneto-gravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. In this work, the new measurement gives a free neutron lifetime of $τ_n$ = 876.3(2.4) stat (0.8) syst . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

What Is the Limit of Quantification for the Minor Phase in Time-of-Flight Neutron Diffraction? A Case Study on Fe and Ni Powder Mixtures at VULCAN

A phase present in small quantities within materials may not simply serve as a secondary component; it can play a crucial role in determining the integrity, properties, and performance of the material. These minor but important phases usually draw attention in material design and processing for fundamental understanding as well as material quality control. Accurately quantifying a minor phase amid a majority phase, especially at extremely low fractions, remains a challenging task. Time-of-flight neutron diffraction, coupled with advanced pattern analysis techniques like Rietveld refinement, is a powerful tool for crystal structure identification and phase quantification. The deep penetrating capability of neutrons enables the detection and quantification of trace phases within materials. In this study, the quantification limits of time-of-flight neutron diffraction were explored using the VULCAN diffractometer at the Spallation Neutron Source, using Fe–Ni powder mixtures as a sample system. By comparing the refinement results to the known weighed values, it was determined that the reliable quantification of a minor Ni phase is achievable down to about 0.1 wt% while a Ni fraction as low as 0.02 wt% is difficult to trace. Effective control of the refinement parameters, especially the profile function parameters, are found to significantly influence the convergence of fittings and the accuracy of phase quantification.

Rietveld refinement↗

A Review of Basic Energy Reconstruction Techniques in Liquid Xenon and Argon Detectors for Dark Matter and Neutrino Physics Using NEST

Detectors based upon the noble elements, especially liquid xenon as well as liquid argon, as both single- and dual-phase types, require reconstruction of the energies of interacting particles, both in the field of direct detection of dark matter (weakly interacting massive particles WIMPs, axions, etc.) and in neutrino physics. Experimentalists, as well as theorists who reanalyze/reinterpret experimental data, have used a few different techniques over the past few decades. In this paper, we review techniques based on solely the primary scintillation channel, the ionization or secondary channel available at non-zero drift electric fields, and combined techniques that include a simple linear combination and weighted averages, with a brief discussion of the application of profile likelihood, maximum likelihood, and machine learning. Comparing results for electron recoils (beta and gamma interactions) and nuclear recoils (primarily from neutrons) from the Noble Element Simulation Technique (NEST) simulation to available data, we confirm that combining all available information generates higher-precision means, lower widths (energy resolution), and more symmetric shapes (approximately Gaussian) especially at keV-scale energies, with the symmetry even greater when thresholding is addressed. Near thresholds, bias from upward fluctuations matters. For MeV-GeV scales, if only one channel is utilized, an ionization-only-based energy scale outperforms scintillation; channel combination remains beneficial. We discuss here what major collaborations use.

argon↗

Nanoscopic lipid domains determined by microscopy and neutron scattering

Biological membranes are highly complex supramolecular assemblies, which play central roles in biology. However, their complexity makes them challenging to study their nanoscale structures. To overcome this challenge, model membranes assembled using reduced sets of membrane-associated biomolecules have been found to be both excellent and tractable proxies for biological membranes. Due to their relative simplicity, they have been studied using a range of biophysical characterization techniques. Here, in this review article, we will briefly detail the use of fluorescence and electron microscopies, and X-ray and neutron scattering techniques used over the past few decades to study the nanostructure of biological membranes.

59 BASIC BIOLOGICAL SCIENCES↗

Multi-scale investigation of heterogeneous swift heavy ion tracks in stannate pyrochlore

Er 2 Sn 2 O 7 pyrochlore was irradiated with swift heavy Au ions (2.2 GeV), and the induced structural modifications were systematically examined using complementary characterization techniques including transmission electron microscopy (TEM), X-ray diffraction (XRD), and neutron total scattering with pair distribution function (PDF) analysis. Each technique probes different aspects and length scales of the transformed material regions. TEM revealed a core–shell ion track structure—an amorphous core surrounded by a disordered, anion-deficient fluorite shell—which was confirmed by XRD. Neutron total scattering, with sensitivity to the oxygen sublattice, provided relative fractions of amorphous and disordered fluorite phases and confirmed the presence of a defective pyrochlore phase, which largely maintains its structural ordering but is clearly distinct from the pristine pyrochlore matrix. This defect-rich pyrochlore phase forms a halo extending radially beyond the well-characterized core–shell track morphology observed in electron micrographs. Despite their differing long-range periodicity, the short-range structures of the amorphous, disordered, and defective pyrochlore phases are all modeled well with a weberite-type configuration. Evolution of the phase fractions with increasing ion fluence was examined to ascertain the phase-to-phase pathways that occur during primary and secondary ion impact. Furthermore, this approach extends knowledge about the multi-scale response of stannate pyrochlores to swift heavy ion irradiation in the electronic energy loss regime and improves existing track-overlap models.

36 MATERIALS SCIENCE↗

Neutron generator based on intense lithium beam driver

We are proposing a compact neutron generator based on a Li beam driver. The proposed neutron generator comprises a laser ion source, a radio-frequency quadrupole linear accelerator (RFQ linac), a drift tube linac, and a target containing protons. In the generator, the lithium ion is used as a projectile instead of protons to utilize the kinematic focusing technique. The technique enables us to enhance the neutron flux without increasing the beam energy, which is important to develop a clean compact neutron generator. Moreover, the combination of a laser ion source and a RFQ linac with the direct plasma injection scheme will provide several tens of mA of a fully ionized lithium beam, which is much higher than that of conventional heavy ion sources comparable with proton drivers. Neutrons are generated by the nuclear reaction of the lithium ions and protons in the beam target. In this paper, we reported the current status of the development. For RFQ, we designed the RFQ rods to accelerate 40 mA of 7Li3+. We fabricated and installed the rods into a cavity, and, as a first test, accelerated 10 mA of C6+ successfully.

Ikeda, Shunsuke (ORCID:0000000339800577)↗

Detector Characterization for Accurate Monte Carlo Simulation and Neutron Energy-spectrum Unfolding

This report details the characterization of a deuterated scintillation detector for use in neutron spectroscopy via the spectrum unfolding technique. The active volume of the detector consists of a 3-in. diameter by 3 in. depth right circular cylinder that contains 337 cm3 of liquid scintillator EJ-315, deuterated benzene with a D:H ratio of 141:1. A deuterated scintillator is desirable for unfolding fast neutron energy spectra because the backscattering of neutrons from deuterium produces peaks in the pulse height response corresponding to the incident neutron energy. Spectrum unfolding requires the detector’s response to be accurately known for any input neutron energy. The characterization in this report supports using a simulated response matrix calibrated by the measured light output and convolved with the measured resolution to produce a response matrix without bringing the detector to a neutron beam facility for characterization. In particular, characterization measurements were performed that included calibration of the detector’s light output to recoil electrons from gamma sources, calibration of the detector’s resolution to recoil electrons, and calibration of the detector’s light output to recoil protons from a time-tagged neutron source and a monoenergetic 14.1 MeV neutron source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of residual stresses in isothermal friction stir welded 304L stainless steel plates

Friction stir welding was performed on 304L SS plates in order to heal simulated cracks created by electrical discharge machining. Two different tool temperatures (825 and 725 °C) were chosen for this study. Both neutron diffraction and X-ray diffraction techniques were employed to evaluate the residual stresses along two orthogonal reference directions, longitudinal (syy) and transverse (sxx). The former technique was also used to measure residual stresses at various depths. It was found that, at 1 mm depth from the top surface inside the stir zone (SZ), the longitudinal component was tensile in nature while the transverse component was compressive. The nature and magnitude of the residual stress fields, and the position of the peak residual stresses were found to vary with the weld depth. The SZ of the 725 °C weld exhibited higher peak stress than 825 °C weld mainly due to a lack of stress relief at the lower temperature.

Friction stir welding, Steel↗

Tensile Deformation of DED Graded IN718-René41 Superalloy at 650°C by in-situ Neutron Diffraction and Digital Image Correlation

A compositionally graded material comprised IN718 (718, γ'/γ" strengthened superalloy) and René41 (R41, a medium γ' strengthened superalloy) was fabricated using laser blown-powder directed energy deposition (DED/LB-M). Hot gas path components that require high and low temperature capabilities at different locations may benefit from such graded superalloy, potentially eliminating the use of welded or mechanically joined components and reducing cost. In the present work, microstructure and 650°C tensile behavior of 718-R41 graded superalloy in as-built and heat-treated states are investigated by Digital Image Correlation (DIC), in-situ neutron diffraction, coupled with conventional characterization techniques. The applied heat treatment generates static recrystallization and equiaxed grains in 718 rich compositions, while R41 rich compositions remain partially or un-recrystallized. Yield strengths of 718 and R41 sections in heat-treated state are comparable to wrought forms but the graded compositions show weakness. From neutron experiment, diffraction elastic constants and single crystal elastic constants are calculated, which show small difference between the as-built and heat-treated states and between the γ and γ' phases. Grain-level load transfer from the (220) grains to (200) grains is found to be composition dependent, and qualitatively agrees with DIC measured macroscopic yield strength. Within the (200) grains, the γ/γ' phases deform elastically until the γ phase yields and afterwards the γ' phase takes load from γ phase.

digital image correlation↗

Neutron-neutron quasifree scattering in neutron-deuteron breakup at 10 MeV

New measurements of the neutron-neutron quasifree scattering cross section in neutron-deuteron breakup at an incident neutron energy of 10.0 MeV are reported. The experiment setup was optimized to evaluate the technique for determining the integrated beam-target luminosity in neutron-neutron coincidence cross-section measurements in neutron-deuteron breakup. The measurements were carried out with a systematic uncertainty of ± 5.6%. Our data are in agreement with theoretical calculations performed using the CD-Bonn nucleon-nucleon potential in the Faddeev formalism. The measured integrated cross section over the quasifree peak is 20.5 ± 0.5(stat) ± 1.1 (sys) mb/sr 2 in comparison with the theory prediction of 20.1 mb/sr 2 . Overall, these results validate our technique for determining the beam-target luminosity in neutron-deuteron breakup measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Overview and Current Status of Neutron Imaging at Oak Ridge National Laboratory

Neutron imaging is a non-destructive technique used to study the internal structure and composition of a wide range of materials. At Oak Ridge National Laboratory (ORNL), there are two neutron imaging beamlines that provide complementary capabilities that serve a diverse community, from materials science and engineering to biomedical and plant sciences. This report provides an overview of the current ORNL imaging capabilities that support materials research for a broad user community.

Torres, James [ORNL] (ORCID:0000000289407610)↗