Search NASA⌕ Search

SEARCH · Search NASA

Results for “non-invasive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Spectroscopic Chemical Analysis Methods and Apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted along with photoluminescence spectroscopy (i.e. fluorescence and/or phosphorescence spectroscopy) to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

Remote Sensing of Solar-Induced Chlorophyll Fluorescence (SIF) in Vegetation: 50 Years of Progress

Remote sensing of solar-induced chlorophyll fluorescence (SIF) is a rapidly advancing front in terrestrial vegetation science, with emerging capability in space-based methodologies and diverse application prospects. Although remote sensing of SIF – especially from space – is seen as a contemporary new specialty for terrestrial plants, it is founded upon a multi-decadal history of research, applications, and sensor developments in active and passive sensing of chlorophyll fluorescence. Current technical capabilities allow SIF to be measured across a range of biological, spatial, and temporal scales. As an optical signal, SIF may be assessed remotely using highly-resolved spectral sensors and state-of-the-art algorithms to distinguish the emission from reflected and/or scattered ambient light. Because the red to far-red SIF emission is detectable non-invasively, it may be sampled repeatedly to acquire spatio-temporally explicit information about photosynthetic light responses and steady-state behaviour in vegetation. Progress in this field is accelerating with innovative sensor developments, retrieval methods, and modelling advances. This review distills the historical and current developments spanning the last several decades. It highlights SIF heritage and complementarity within the broader field of fluorescence science, the maturation of physiological and radiative transfer modelling, SIF signal retrieval strategies, techniques for field and airborne sensing, advances in satellite-based systems, and applications of these capabilities in evaluation of photosynthesis and stress effects. Progress, challenges, and future directions are considered for this unique avenue of remote sensing.

Review↗

Noninvasive Breath Analysis Using NASA E-Nose Technology for Health Assessment

Clinical breath analysis is based on the fact that many important metabolites and biomarker molecules are present at detectable levels in exhaled breath, and many of these molecules correlate with human disease or correlate with physiological states that could lead to a decline in health. Presented is a technology that utilizes an array of chemical sensors combined with humidity, temperature and pressure for real time breath analysis to correlate the chemical information in the breath with the state and functioning of different human organs. For example, a marker for pulmonary inflammation processes of the lower respiratory tract, e.g. asthma, is the increase of the nitrogen oxide (NO) concentration in breath. Other volatile biomarkers may correlate with infectious process, metabolic conditions and inflammatory diseases, such as traumatic brain injury (TBI). This technology is also called "electronic nose" (E-Nose) in the sense that the device can mimic human nose to smell odors using a pattern recognition technique to analyze the sensor array data. Breath sampling is non-invasive and can be analyzed in real-time.

Li, Jing↗

Psychophysiological Monitoring of Aerospace Crew State

As next-generation space exploration missions necessitate increasingly autonomous systems, there is a critical need to better detect and anticipate crewmember interactions with these systems. The success of present and future autonomous technology in exploration spaceflight is ultimately dependent upon safe and efficient interaction with the human operator. Optimal interaction is particularly important for surface missions during highly coordinated extravehicular activity (EVA), which consists of high physical and cognitive demands with limited ground support. Crew functional state may be affected by a number of variables including workload, stress, and motivation. Real-time assessments of crew state that do not require a crewmember’s time and attention to complete will be especially important to assess operational performance and behavioral health during flight. In response to the need for objective, passive assessment of crew state, the aim of this work is to develop an accurate and precise prediction model of human functional state for surface EVA using multi-modal psychophysiological sensing. The psychophysiological monitoring approach relies on extracting a set of features from physiological signals and using these features to classify an operator’s cognitive state. This work aims to compile a non-invasive sensor suite to collect physiological data in real-time. Training data during cognitive and more complex functional tasks will be used to develop a classifier to discriminate high and low cognitive workload crew states. The classifier will then be tested in an operationally relevant EVA simulation to predict cognitive workload over time. Once a crew state is determined, further research into specific countermeasures, such as decision support systems, would be necessary to optimize the automation and improve crew state and operational performance.

Wusk, Grace C.↗

Temporal Changes in Astronauts’ Muscle and Cardiorespiratory Physiology Pre-, In-, and Post-Spaceflight

NASA’s vision for future exploration missions depends on the ability to protect astronauts’ health and safety for performance of Extravehicular Activity (EVA), and to allow astronauts to safely egress from vehicles in a variety of landing scenarios (e.g. water landing upon return to Earth and undefined planetary/lunar landings). Prolonged exposure to spaceflight results in diminished tolerance to prolonged physical activity, decreased cardiac and sensorimotor function, and loss of bone mineral density, muscle mass, and muscle strength. For over 50 years exercise has been the primary countermeasure against these physiologic decrements during spaceflight, and while the resulting protection is adequate for ISS missions (i.e., Soyuz landing, microgravity EVAs), there is little information regarding time-course changes in muscle and aerobic performance. As spaceflight progresses towards longer exploration missions and vehicles with less robust exercise capabilities compared to ISS, countermeasures will need to be combined and optimized to protect crew health and performance across all organ systems over the course of exploration missions up to 3 years in duration. This will require a more detailed understanding of the dynamic effects of spaceflight on human performance. Thus, the focus of this study is quantifying decrements in physical performance over different mission durations, and to provide detailed information on the physiological rational for “why” and “when” observed changes in performance occur. The research proposed will temporally profile changes in astronauts’ cardiorespiratory fitness, muscle mass, strength, and endurance over spaceflight missions of 2 months, 6 months, and up to 1 year in duration. Additionally, an extrapolation model will provide predictions for changes associated with exploration missions 2-3 years in duration. To accomplish these objectives astronauts will be asked to participate in pre, in, post-flight measurement of muscle performance, muscle size, cardiorespiratory fitness and submaximal performance capabilities, as well as non-invasive assessment of cerebral and muscle oxygenation and perfusion (Table 1). Additionally, ambulatory and in-flight exercise, nutrition, and sleep will be monitored using a variety of commercial technologies and in-flight assessment tools. Significance: Our detailed testing protocol will provide valuable information for describing how and when spaceflight-induced muscle and aerobic based adaptations occur over the course of spaceflight missions up to and beyond 1 year. This information will be vital in the assessment as to whether humans can be physically ready for deep space exploration such as Mars missions with current technology, or if additional mitigation strategies are necessary.

Downs, M. E.↗

BioLEAD: BioLogical Exploration via Autonomous Detection – Using Dielectric Spectroscopy to Monitor Biological Changes in Response to Deep Space Radiation

Leveraging the bio-fluidic hardware developed for BioSentinel, we propose a new payload for autonomous missions: BioLEAD – BioLogical Exploration via Autonomous Detection. With NASA's renewed focus to continue human exploration of the Moon (Artemis Program), the BioLEAD payload aims to investigate the effects of the lunar environment on biology, whether onboard a lunar lander, the Lunar Gateway, or as a free-flying CubeSat orbiting the Moon. In place of an optical detection system, BioLEAD will employ a miniaturized, non-invasive dielectric spectroscopy sensor to enable real-time monitoring of biological activity. The sensor operates by relating capacitance measurements to the dielectric properties of the cell, such as cell morphology, doubling time, and cell cycle stage. The implementation of this new sensor technology will address limitations of the optical measurement system used on BioSentinel. It will also advance the use of autonomous bioanalytical microsystems and reveal new information regarding biological responses to the Moon’s radiation environment. Most importantly, BioLEAD’s technology will be adaptable for a wide array of future missions.

Biosensor↗

Application of a First-Principles Anomalous Transport Model for Electrons to Multiple Hall Thrusters and Operating Conditions

We have developed a physics-based model based on a pseudo-particle description of the electron cyclotron drift instability. A key improvement of the model with respect to previous work is that linear theory is not applied in the event of wave saturation and deviations of electrons or ions from a Maxwellian distribution function. In the acceleration region, the anomalous collision frequency is computed as the minimum value necessary to prevent the electron drift velocity from exceeding the thermal velocity. A functional based on the electron equilibration time is defined to control the transition from high to low resistivity regions. The model was previously applied to a single Hall thruster at its nominal operating condition, showing promising results that captured accurately the location of the thruster’s acceleration region. In this paper, we extend the use of this firstprinciples models to two additional thrusters, also considering multiple operating conditions for each of them. Numerical results are compared to experimental measurements obtained with non-invasive laser induced fluorescence. In general, the agreement between experiments and simulations is good. The model is able to predict the location of the acceleration region for all cases. We observe however that fine details, such as changes in the plasma potential gradient within the acceleration regions, are not captured. The model is also insensitive to changes in the magnetic field strength while experiments show that small shifts in location (of less than 5% of the acceleration channel length) occur. We plan to address the weaknesses of our method with the help of physical insight gained from kinetic simulations of the acceleration region.

Chaplin, Vernon H.↗

Indirect Magnetic Measurements on the Aerodynamic Heating Facility (AHF)

The arc jet complex at NASA Ames Research Center (ARC) investigates various thermal protection systems (TPS) and their performance in high enthalpy flow environments to improve heat shields used in atmospheric entry. The arc jet operates by inducing an arc between two electrodes and passing the heated gas through a supersonic nozzle. The arc plasma is typically a partially ionized air mixture at low temperature (< 2 eV) but operates for long periods of time (up to 30 min) at high power (< 60 MW). However, simulations using the in-house ARC Heater Simulator (ARCHeS) code predict that the arc is still unstable to MHD instabilities, primarily the kink instability, which limit the operational envelope of the facility [1]. Consequently, it is important to better characterize these instabilities to improve facility stability and extend operational ranges. Due to the high enthalpy and long timescales (i.e., minutes) arc diagnostics must be non-invasive (i.e., optical or magnetic). This work will cover the development of tri-axial magnetic hall sensors for arc jet instabilities and subsequent 3D characterization of arc motion. The latest results describing the kink instability amplitude, frequency and wavelength will be presented and represent the first measurements of this instability in a NASA arc jet facility. References: [1] Meurisse, J. (2018). 3D Unsteady Model of Arc Heater Plasma Flow Using the ARC Heater Simulator (ARCHeS), APS Gaseous Electronics Conference, 2018: APS.

Sebastian Vicente Colom↗

Method Development for In-situ Detection of Latent Herpesvirus DNA from Saliva using Nanopore Sequencing

Research toward latent herpesvirus reactivation has been intensively addressed through Space Shuttle and International Space Station (ISS) investigations. This work has provided the understanding that persistent reactivation of herpesviruses from asymptomatic crew can be detected through viral shedding in saliva, urine, and blood. Occasionally, viral reactivation from the latency stage can pose a threat to crew health (clinical manifestation) before, during, and after flight missions. Furthermore, previous work detailing correlations with immunity indicate that monitoring viral reactivation could be implemented to assess potential immune dysfunction. While in-flight monitoring is desirable, there is no well-established procedure or method for real-time evaluations, and research to date has relied on postflight, ground-based analysis. The development of portable molecular technologies like the miniPCR™ (miniPCR Bio) thermal cycler and the MinION™ sequencer (Oxford Nanopore Technologies) have confirmed that real-time monitoring is possible in extreme and low resource environments. These devices, combined with simple sample preparation methods, have been used to demonstrate bacterial identification onboard the ISS, as well as rapid viral detection in remote locations on Earth. The work here builds upon previous molecular advancements onboard the ISS toward the development and validation of a spaceflight-compatible method for viral detection from crew samples. Several herpesviruses can be detected in saliva, which provides a non-invasive means to collect samples for monitoring. While the basis for this method lies in previous spaceflight investigations, key points for method optimization include DNA extraction from saliva, viral primer selection, and bioinformatic processes for data analysis. To increase viral yield, numerous DNA extraction methods have been evaluated and will be discussed in detail. For initial development and testing, varicella-zoster virus (VZV) is being targeted though open reading frame 51 and 63 (ORF51, ORF63), as the replication origin-binding protein is highly expressed during latency. Optimization of the thermal cycling parameters has resulted in the ability to test the entire process. The full method has been tested with both viral VZV DNA standards and saliva spiked with varying concentrations of VZV. Viral sequence data were mapped to the reference sequence using minimap2. Prior to mapping, DNA sequencing reads were filtered for length and quality, barcodes were removed, and alignment identity calculated. Following further assessments, statistics were compared across multiple sequencing experiments and are being used to determine the success of the protocols. Forward work will include the incorporation of herpes simplex virus 1 (HSV-1) and Epstein-Barr virus (EBV) primers as well as the validation of results to the terrestrial qPCR standard assay. Upon full validation of the developed method, saliva will be collected from 20 healthy subjects and spiked with viral DNA. These samples will be split and assayed with the MinION and standard qPCR assay.

Hang N Nguyen↗

Space-Cent: Studying the Physiological and Anatomical Effects of Centrifugation and Head Down Tilt: 2021 Update

BACKGROUND The objective of this study was to evaluate the cerebral and ocular physiological and anatomical effects of head-down tilt bedrest (HDBR) with and without daily artificial gravity (AG) in healthy subjects to provide novel insights into possible countermeasures for the Spaceflight Associated Neuro-ocular Syndrome (SANS). Previous long-term studies using the spaceflight analog of strict 6° HDBR for 30 days revealed changes in ocular structure, including optic disc edema. The effects of an AG countermeasure using intermittent centrifugation to restore upright hydrostatic gradients and reduce the ocular and brain anatomical effects has not been explored. METHODS The effects of 60-day exposure to simulated microgravity (6° HDBR) on the cerebral, ocular and vestibular systems with and without the intervention of daily 30 minute exposure to AG (short-arm centrifugation) was evaluated in 24 healthy subjects. Non-invasive measurements of cerebral blood flow, intracranial blood volume (near infrared spectroscopy, NIRS), cerebral and ocular structure (MRI and optical coherence tomography), internal jugular vein area (ultrasound), lateral ventricular volumes (MRI), intraocular pressure, and sensorimotor/vestibular (i.e. balance and coordination) systems were made during various time-points during the bedrest study. Additional measures with ultrasound and NIRS were made during centrifugation. RESULTS The study began in Spring 2019 and all 24 subjects completed the testing by end of 2019. Data analysis continues. We report the following updated results for 2021. MRI showed significant decreases in carotid artery flow, increases in brain and CSF volumes, and aqueductal flow velocities in all subjects in HDT compared to baseline supine, but no effects of the short duration AG. All groups showed increased posterior globe flattening during bedrest compared to baseline, without protection from AG. As previously reported we observed chorioretinal folds for the first time in a bedrest analog, as well as optic disc edema, with no protection from the short-term AG. Data from the study is now being transmitted to the NASA LSDA which will allow for future research. CONCLUSIONS The 6 degree HDBR analog produced significant changes in the anatomical and physiological functions of the brain and eye in healthy subjects. Daily 30 minute exposure to AG with short-arm centrifugation had significant transient effects on physiology of the cerebrovascular system, but was not sufficient to prevent the anatomical effects of HDBR on the brain and eye.

E M Bershad↗

Magnetic Measurements of Arc Instabilities in Segmented Arc Heater Column

The Aerodynamic Heating Facility (AHF) at NASA Ames Research Center (ARC) generates high enthalpy, supersonic flow environments for ground testing of NASAheat shield materials. This arc jet heater operates by passing a DC arc (<3200A,<2500V) through a gas column (~10cm diameter, 2m length) and ejecting the heatedgas through a supersonic nozzle into a test chamber. The arc plasma is a partially ionized air mixture at low temperature (< 2eV) but needs to be stable for long test times (up to 30min) at high power (< 20MW). Currently, the operational envelope of the facility is limited by arc instabilities including the kink instability. Consequently, it is of interest to characterize these instabilities to better understand facility limits and inform methods to extend stable operational ranges. Due to the high enthalpy and long timescales (i.e., minutes) diagnostics must be non-invasive. This work will cover the development of two sets of magnetic sensors: differential B-dot sensors and tri-axial magnetic hall sensors and will describe initial measurements of arc motion usingthese sensors.

Kink instability↗

Magnetic Measurements of Arc Instabilities in Segmented Arc Heater Column

The Aerodynamic Heating Facility (AHF) at NASA Ames Research Center (ARC) generates high enthalpy, supersonic flow environments for ground testing of NASAheat shield materials. This arc jet heater operates by passing a DC arc (<3200 A,<2500 V) through a gas column (~6 cm diameter, 2 m length) and ejecting the heated gas through a supersonic nozzle into a test chamber. The arc plasma is a partially ionized air mixture at low temperature (< 2 eV) but needs to be stable for long test times (up to 30 min) at high power (< 20 MW). Currently, the operational envelope of the facility is limited by arc instabilities including the kink instability. Consequently, it is of interest to characterize these instabilities to better understand facility limits and inform methods to extend stable operational ranges. Due to the high enthalpy and long timescales (i.e., minutes) diagnostics must be non-invasive. This work will cover the development of two sets of magnetic sensors: differential B-dot sensors and tri-axial magnetic hall sensors and will describe initial measurements of arc motion using these sensors.

Kink instability↗

Why Developing A Full-Sun UV Spectrograph Sounding Rocket Is Difficult but Necessary

For a conference focused on a 20-year perspective of where we have been and where we are going, this talk will highlight specifically why we need a sounding rocket to lead the way in obtaining high-resolution UV spectroscopy of our sun-as-a-star. The currently available data is either sparse or at a much lower resolution when compared with Hubble (HST) spectra of other stars. Because of this, we cannot say with certainty if our Sun’s variability is typical. This limitation is hindering our quest to place our Sun in it’s rightful place on our star-charts. Ultraviolet light is a key component in determining this. Elements such as Hydrogen and Iron have strong emission lines here, and from them we can determine many things about the star from which they originate. The width of these spectral features can tell us about the relative plasma activity on the surface of the star, the abundance of those elements, and of course the temperatures. This has of course been done with many instruments that have very narrow field of views and/or narrow bandwidths. The only way to directly compare our Sun’s UV ”fingerprint” with other stars is to take an image of it in the same manner by which HST does: as a point source object. Our team’s aim has been to develop a sounding rocket capable of doing just that. Along the way, the many challenges we face are producing many solutions. A unique take on the traditional Rowland circle spectrograph will allow us to cover a large range of UV spectra with minimal moving parts. A novel in-situ gain calibration technique will be used in order to maintain the high level of radiometric accuracy desired. Naturally, complications arise when one takes UV measurements as you are flying out of earth’s atmosphere and back into it. Though it may be minor, the absorbed UV spectra from the atmosphere will have to be accounted for. In preparing for this, we have stumbled across a way in which those ”telluric” absorption lines may prove useful for spectral calibration purposes. In addition, raw data from previous sounding rocket missions may have hidden within them useful information for the atmospheric-physics community. In this talk, we will highlight the unique calibration problems and solutions we have faced, and how those are of greater importance to the greater heliophysics and atmospheric communities. With these amazing developments at hand, the future of heliophysics instrumentation is looking bright. This material is based upon work supported by the NSF EPSCoR RII-Track-1.2a (Non-invasive plasma diagnostics for LTP) Cooperative Agreement OIA-1655280. Any opinions, findings, and conclusions or recommendations expressed in this material are those of the authors and do not necessarily reflect the views of the National Science Foundation.

NASA, UAH, MSU, Sounding Rocket, Aeronomy, Instrum↗

Recommended Practices in Laser-Induced Fluorescence (LIF) Diagnostics for Electric Propulsion

Laser-induced fluorescence (LIF) spectroscopy uses Doppler-shifted laser photons to excite a bound electron transition in an atom or ion, with subsequent fluorescence emission detected in order to measure the local velocity distribution function (VDF) and/or particle density. Due to its non-invasive nature, high spatial resolution, and acceptable difficulty of implementation, LIF has become a favored diagnostic for electric propulsion (EP) plasmas, particularly in the study of Hall thrusters. This paper presents recommended best practices for LIF measurements in electric thrusters, drawn from over three decades of implementation heritage in the EP community. Focusing on both single-photon LIF (typically used to measure VDFs) and two-photon LIF (TALIF, typically used to determine densities), the paper covers selection of atomic transitions to target, experimental setups, and interpretation of data. A number of special topics and advanced applications are discussed, including uncertainty analysis, techniques for high-speed measurements, and applications to a variety of propellants.

plasma plume↗

Machine-Protection System for the PIP-II Linear Accelerator: Architecture and Data Processing Schemes

PIP-II at Fermilab features a brand-new, 800 MeV leading-edge Linear Accelerator (Linac) that will enable the Fermilab complex to deliver more than a megawatt of beam power to the Long Base-line Neutrino Facility (LBNF), requiring a robust Machine Protection System (MPS) to prevent beam-induced damage to delicate cryomodules and vacuum components. Signals in various accelerator components, in both analog and digital format, are collected and processed to assest the operating conditions of the accelerator. In the situation a potential damage is foreseen, the beam permit signal will be drop. A critical element of this system is the fast Analog Machine Protection System, a high-bandwidth platform designed for real-time beam loss monitoring. The system utilizes a modular, FPGA-based architecture to digitize signals from beam-sensing devices, such as AC Current Transformers (ACCTs), non-invasive Ring Pickups (RPUs) and beam scrapers. To eliminate both high frequency as well as 60 Hz noise that might be picked up in the industrial environment, data processing schemes beyond regular digital filtering are planned and implemented.

Wu, Jinyuan [Fermilab] (ORCID:0000000344329521)↗

Acoustic sensing and autoencoder approach for abnormal gas detection in a spent nuclear fuel canister mock-up

Currently, spent nuclear fuel (SNF) from commercial nuclear power plants is stored in stainless-steel canisters for interim dry storage. To provide an inert environment, these canisters are backfilled with helium after vacuum drying. However, the helium environment may be contaminated during extended storage because of the material degradation. For example, the heavier fission gas xenon may be released from the fuel rods into the canister cavity should the fuel cladding be breached. Other gases such as air and water vapor may also be present as a result of leakage caused by chloride-induced stress corrosion cracking on the canister walls or by insufficient vacuum drying. Therefore, monitoring the gas composition can provide critical information about the health of SNF canisters. In this study, noninvasive testing was conducted on a 2/3-scaled SNF canister mock-up using acoustic sensing. Ultrasonic transducers were placed on the exterior surface of the canister to probe the gas composition. A dataset was collected by sealing the canister mock-up and introducing up to 1.53% argon or 1.29% air into the helium background gas. Three methods were used to detect changes in the gas composition: the time-of-flight (TOF) method, the differential method, and the autoencoder method. Results showed that the TOF method had sufficient resolution to detect abnormal gas concentrations of less than 1.0%. The differential method demonstrated a periodic in-phase and out-of-phase behavior between the benchmark (i.e., pure helium) and abnormal (i.e., with argon or air) state signals. The variational autoencoder (VAE) and the Wasserstein autoencoder (WAE) were trained on the benchmark data and were applied directly to the abnormal state data. It was found that both the unsupervised VAE and the WAE were able to distinguish the benchmark and abnormal states of the canister mock-up based on the reconstruction error.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Diffractive Optic Fluid Shear Stress Sensor

Light scattering off particles flowing through a two-slit inteference pattern can be used to measure the shear stress of the fluid. We have designed and fabricated a miniature diffractive optic sensor based on this principle.

fluid shear stress micro sensor non-invasive senso↗

Diffractive Optic Fluid Shear Stress Sensor

Light scattering off particles flowing through a two-slit interference pattern can be used to measure the shear stress of the fluid. We have designed and fabricated a miniature diffractive optic sensor based on this principle.

optics↗