Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear forensic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

The oxygen stable isotope composition of CRM 125-A UO 2 standard reference material

While there is a clear need for standardized reference materials for analytical calibrations and for inter-laboratory comparisons, there are not currently any for the oxygen stable isotopic composition of uranium oxides. In this paper we summarize the results from four laboratories by seven different methods of oxygen stable isotope analyses using fluorination techniques of CRM 125-A UO 2 Standard Reference Material. We synthesize these data and methods to arrive at a consensus oxygen stable isotope composition for CRM 125-A $δ$ 18 O = -9.63‰ (±0.29‰) VSMOW. We discuss methodological differences between analytical approaches, including furnace vs laser heating, fluorination using BrF 5 or ClF 3 , as well as calibration strategies. We highlight the potential effects of calibration scale compression from single-point calibrations using reference material with $δ$ 18 O values having a large relative difference from the sample being analyzed. We demonstrate how calibration scale compression can yield differences in calibrated $δ$ 18 O values up to ~2‰ for samples with ~20‰ difference from a single reference material, if the calibration slope of different analytical systems differs by 0.1. In conclusion, we suggest the use of liquid water calibration standards sealed in silver capillary tubes for multi-point calibrations of fluorination analysis systems.

07 ISOTOPE AND RADIATION SOURCES↗

Improving microstructures segmentation via pretraining with synthetic data

Image analysis of material microstructures through microscopy is an integral capability in the field of materials science. The topological and chemical information obtained through microscopy allow us to draw vital connections between material microstructures, properties, and processing. While scanning electron microscopy (SEM) is able to yield a considerable wealth of information interpretable by the intuition of experts, there has been considerable interest in using machine learning, convolutional neural networks (CNNs) in particular, for such image analysis task. Training CNNs for an image analysis task requires a large annotated dataset. However, in many materials science applications, obtaining a large annotated dataset is cost and labor intensive. In this work, we study the use of synthetic data to enlarge the available annotated experimental data of uranium oxide. We utilize a modified Potts model to simulate uranium oxide particles with morphologies similar to those observed experimentally. We then leverage an image-to-image translation model to synthesize the simulated particles as if they are acquired with SEM. Through this process, we obtain pairs of particle images and their corresponding SEM representations, which corresponds to pairs of annotations and images. Unlike previous works, we leverage synthetic data for pretraining a CNN model prior, and finetune that model further with experimental data. We experimentally demonstrate that using synthetic data as incremental learning process benefits the overall performance compared to training a model on combined synthetic and experimental data.

36 MATERIALS SCIENCE↗

Optical vibrational spectroscopic signatures of ammonium diuranate process parameters

Ammonium diuranate (ADU) is commonly encountered in the nuclear fuel cycle; however, previous investigations have shown that ADU is a complex mixture of distinct compounds. Moreover, production parameters are known to heavily influence the composition of the resulting ADU. Here, we examine four samples of ADU prepared at Oak Ridge National Laboratory (ORNL), and one sample of ADU made at Pacific Northwest National Laboratory (PNNL), with the goal of further characterizing and elucidating the effect of processing parameters such as stir rate, strike direction, and temperature on material composition. Process parameters during ADU precipitation at ORNL and PNNL were well documented, and we relate process variables to optical vibrational spectroscopic signatures observed using Raman and infrared (IR) spectroscopy. In addition, powder X-ray diffraction (PXRD) reveals differences in the solid-phase composition of ADU precipitates, but we find that the primary phase is similar to the uranyl oxyhydroxyhydrate mineral metaschoepite. Despite the significant phase contributions of a metaschoepite-like phase, spectroscopic evidence of both nitrate and ammonium are observed for all samples. To gain a more holistic understanding of spectroscopic features of process parameters in ADU, principal component analysis (PCA) is employed and results in observable signatures that relate to the stir rate used during synthesis. These results provide further information about the process-dependence of ADU precipitate composition.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Morphological and chemical characteristics of oxide scales formed on δ-Phase plutonium metal alloys I: 3.5 at% ga

Focused ion-beam scanning electron microscopy (FIB-SEM) and three-dimensional (3D) microscopy were applied to characterize the subsurface morphological features of oxide scales formed on an ~3.5 at.% Ga plutonium (Pu) metal alloy. Using the FIB-SEM technique, a number of morphological features formed in the interior of the oxide scale from Pu metal's environmental exposure were observed and identified. Here, Auger electron spectroscopy (AES) was utilized to characterize the cross-sectional composition and chemistry of the oxide scale. The oxide scale formed during inert storage and operational environments has a characteristic internal scale structure that includes a relatively dense oxide layer with some lateral and transverse cracking. Generally, after subsequent exposure to dry air environment, the oxide scale retained most of the original structural and chemical characteristics. However, after aging in a moist air environment, while the oxide scale was found to maintain the chemical characteristics of the source oxide, the scale was found to be on average thinner and without the previously observed internal microcracking, likely the result of spallation of the source scale during exposure to the new environment.

36 MATERIALS SCIENCE↗

Morphological and chemical characteristics of oxide scales formed on δ-phase plutonium metal alloys II: 2.0 at% Ga

The focused ion-beam scanning electron microscopy (FIB-SEM) and three-dimensional (3D) microscopy were applied to characterize the subsurface morphological features of oxide scales formed on an ~2.0 at. % Ga plutonium (Pu) metal alloy. Using the FIB-SEM technique, a number of morphological features formed in the interior of the oxide scale from Pu metal’s environmental exposure were observed and identified. Auger electron spectroscopy (AES) was utilized to characterize the cross-sectional composition and chemistry of the oxide scale. The oxide scale formed during inert storage and operational environments was found to be highly variable in thickness and morphology, presenting some regions with a thin (<400 nm), dense oxide layer and others with a thick (>2 µm) scale with substantial lateral cracking. After subsequent exposure to dry air environment, the oxide scale became thicker (~4 µm) and slightly more porous. The changes following aging in a moist air environment were observed to be more severe, with the formation of a highly porous internal structure containing significant lateral and transverse cracking. In comparison to the scale formed on an ~3.5 at. % Ga-Pu metal alloy, the oxide morphology of the lower gallium alloy investigated here exhibited greater variation in thickness and a noteworthy dependence on the presence of water vapor, particularly in terms of the internal porosity formed during growth of the oxide.

36 MATERIALS SCIENCE↗

Molybdenum and Tungsten isotope compositions of UO 2 fuel pellets: Implications for isotopically enriched taggants

The addition of isotopically enriched taggants to material at the front end of the nuclear fuel cycle could be a powerful tool used to assist law enforcement authorities should material outside of regulatory control be found. Two potential candidates for this purpose are molybdenum (Mo) and tungsten (W) as both elements have five or more stable isotopes and are trace elements contained within nuclear fuel. So there is a concern that Mo and W could undergo isotope fractionation during processes like uranium enrichment and to date, it is unknown if nuclear fuels have natural Mo and W isotope compositions. If Mo and W isotopic variability is present in nuclear fuels, this would hinder the use of these elements as isotopic taggants because it would be difficult to discern the original taggant isotope composition with high confidence. Therefore, a set of 16 low enriched uranium (LEU) fuel pellets from US commercial producers was analyzed using multi collector-inductively coupled plasma mass spectrometry (MC-ICPMS) to determine Mo and W isotope compositions (i.e., 94 Mo/ 92 Mo, 95 Mo/ 92 Mo, 96 Mo/ 92 Mo, 97 Mo/ 92 Mo, 98 Mo/ 92 Mo, 183 W/ 182 W, 184 W/ 182 W, and 186 W/ 182 W). Relative to terrestrial standards, LEU fuel pellets have variable Mo and W isotope compositions, thereby complicating the use of these elements as isotopically enriched taggants. As such, this work demonstrates that the isotope composition of any potential taggant must be well characterized in the base nuclear fuel prior to any taggant addition. Furthermore, these results suggest that Mo and W are not ideal candidates for isotopically enriched taggants.

58 GEOSCIENCES↗

Probing the thermal decomposition of plutonium (III) oxalate with IR and Raman spectroscopy, X-ray diffraction, and electron microscopy

The thermal decomposition of Pu(III) oxalate was analyzed by Raman microspectroscopy, infrared spectroscopy, scanning electron microscopy, and powder X-ray diffraction. These data show that crystalline Pu 2 (C 2 O 4 ) 3 •9H 2 O progressively loses water and oxalate ligands as it is heated, which leads to a decrease in long-range lattice ordering, though minimal changes are observed in gross crystalline morphology. The onset of PuO 2 formation was observed between 200 - 250 °C. Thermal decomposition of oxalate ligands leads to the formation of CO 2 and plutonium oxalate-carbonate moieties, which had not been observed in previously published thermogravimetric measurements of Pu(III) oxalate. Formation of plutonium oxalate-carbonate moieties is believed to be associated with a change in the plutonium oxidation state from 3+ to 4+, which occurs prior to PuO 2 formation. The data provided herein demonstrate the rich spectroscopic nature of a rather underexplored, and technologically relevant, plutonium system. Ideally these results will further future investigations into the Pu(III) oxalate system both experimentally and computationally.

36 MATERIALS SCIENCE↗

Optical vibrational spectroscopic signatures related to U 3 O 8 production processes

Uranium ore concentrates are materials found early within the nuclear fuel cycle and contain high concentrations of uranium in an easily transported form, making the concentrates a likely target for illegal diversion. These concentrates are typically converted to U 3 O 8 for further processing and, therefore, may lose specific physicochemical characteristics in determining the materials’ source and processing history. In this work, we explore the Raman spectra of eight oxide samples produced from various uranium ore concentrates and processing pathways to examine the presence of spectroscopic signatures relating to each sample's process history. Samples produced from amine extraction and dialkylphosphoric acid extraction processes show unique characteristics due to high concentrations of α-UO 3 , whereas samples calcinated from metallic diuranates do not form pure α-U 3 O 8 because of metallic ion inclusions. Pure α-U 3 O 8 oxide samples are obtained through calcination of ammonium diuranate, ammonium uranyl carbonate, and metastudtite intermediates. The Raman spectra of these oxide samples show close agreement with pristine α-U 3 O 8 spectra. However, deviations from the pristine spectra are observed in the 300–460 cm -1 spectral range. In conclusion, these deviations are unique identifying signatures that were likely created by lasting effects from the process history. Spectral center of mass calculations indicate grouping of samples based on processing history.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Speciation mapping of the oxidation layer on aged uranium dioxide using scanning transmission x-ray spectromicroscopy

In this study, UO 2 was aged in humid air and prepared as a thin section using a focused ion beam (FIB) instrument. The specimen was measured using synchrotron radiation spectromicroscopy techniques at the Beamline 11.0.2 STXM end station of the Advanced Light Source (ALS). Non-negative matrix factorization (NMF) methods were used to identify and map three component x-ray absorption near-edge structure (XANES) spectra in the oxygen K-edge data, revealing a surface layer of U 4 O 9 with a thickness of 206 ± 21 nm, and the bulk of the sample remaining as UO 2 . Uranium N 4,5 -edge XANES spectromicroscopy supports these results. The diffusion-controlled parabolic rate constant for UO 2 oxidation to U 4 O 9 was calculated from the observed layer thickness and compared to literature values. Complementary transmission electron microscopy (TEM) was used to image the sample and identify the phases present in various regions, confirming the STXM results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

U-Pu and Ba-Cs isotopic measurements on Trinitite by laser ablation sampling on the Neoma MC-ICP-MS

In this study we present the results of combined U-Pu and Ba-Cs isotope measurements obtained by laser ablation (LA) sampling of two glassy debris fragments (‘Trinitite’) from the world's first atomic bomb detonation conducted in New Mexico on July 16, 1945. Our primary goal in conducting these measurements was to understand whether examination of the U-Pu and Ba-Cs systematics by direct sampling (e.g. without any chemical separation or purification prior to isotope ratio measurement) could yield meaningful information that would differentiate the Trinitite fragments from glassy material lacking a nuclear fission signature. These measurements were conducted on a ThermoFisher Scientific Neoma multi collector – inductively coupled plasma – mass spectrometer (MC-ICP-MS), which is a relatively new MC-ICP-MS platform, so we also examine the behavior of these isotope systems in standards sampled in solution and via LA. Unsurprisingly, the measurements made on purified solutions of the U, Pu, and Ba isotopic standards produce high precision isotope ratios. Furthermore, this extends to the U-Pu measurements made by LA sampling, with the expected degradation in precision and accuracy related to matrix effects and signal intensity fluctuation. However, the Ba-Cs data acquired by LA is of low precision across all of the matrices examined and bears evidence of complex mass fractionation that will require further investigation to resolve. In total, our results indicate that the observed U-Pu isotope data are of sufficient quality to accurately constrain the U and Pu isotopic composition of glass containing sub-ppm levels of these elements which in turn could be used to differentiate glass containing anthropogenic fission products from natural glass whereas the Ba-Cs LA data cannot be used for this purpose until further methodological refinement is performed.

Ba-Cs↗

A new method for quantifying 64 Cu in nuclear debris samples

Quantifying 64 Cu in post-detonation nuclear debris samples can provide important diagnostic information regarding the structural materials used within a nuclear device. However, this task is challenging due to the weak gamma emissions associated with the decay of 64 Cu, its short half-life (12.701 h), and the presence of interfering fission product radioisotopes. Large quantities of debris sample are generally needed to accurately quantify 64 Cu, which can be problematic in sample-limited scenarios where other radiometric analyses are required. Herein, we present a new method for the separation of 64 Cu from solutions of mixed fission products and demonstrate the quantification of its activity through use of gas-flow proportional beta counting. Here, the new method was validated through a series of rigorous tests and was shown to improve the detection limit of 64 Cu by over two orders of magnitude, from 2.5 × 10 6 to 1.3 × 10 4 atoms/sample for 100 min measurements.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Rapid analysis of 237 Np and Pu isotopes in unseparated sample matrices using ICP-MS/MS

Inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) is an emerging technique for measuring actinide isotopes when assessing pre- and post- detonation nuclear material. In this study, ICP-MS/MS was investigated for direct Np and Pu quantitation in unseparated, dissolved bulk soil matrices. To achieve this, purified nitric oxide (NO) was investigated for the reactivity of Th, Np, U, Pu, Am, and Cm. Purifying NO prior to the collision reaction cell (CRC) results in increased sensitivity and allows for higher gas flows to be utilized for the removal of interferences. Here, the interference from uranium hydrides was mitigated to less than 3.85 x 10 -11 . This method was demonstrated on standard reference materials which were measured for 237 Np and 238,239,240 Pu in dilute sample digestions. The 238 Pu measurement was validated by spiking into a standard reference material and was accurately measured with an excess of 85000 of 238 U.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impact of Controlled Storage Conditions on the Hydrolysis and Surface Morphology of Amorphous-UO 3

The hydration and morphological effects of amorphous (A)-UO 3 following storage under varying temperature and relative humidity have been investigated. This study provides valuable insight into U-oxide speciation following aging, the U-oxide quantitative morphological data set, and, overall, the characterization of nuclear material provenance. A-UO 3 was synthesized via the washed uranyl peroxide synthetic route and aged based on a 3-factor circumscribed central composite design of experiment. Target aging times include 2.57, 7.00, 14.0, 21.0, and 25.4 days, temperatures of 5.51, 15.0, 30.0, 45.0, and 54.5 °C, and relative humidities of 14.2, 30.0, 55.0, 80.0, and 95.8% were examined. Following aging, crystallographic changes were quantified via powder X-ray diffraction and an internal standard Rietveld refinement method was used to confirm the hydration of A-UO 3 to crystalline schoepite phases. The particle morphology from scanning electron microscopy images was quantified using both the Morphological Analysis of MAterials software and machine learning. Results from the machine learning were processed via agglomerative hierarchical clustering analysis to distinguish trends in morphological attributes from the aging study. Significantly hydrated samples were found to have a much larger, plate-like morphology in comparison to the unaged controls. Predictive modeling via a response surface methodology determined that while aging time, temperature, and relative humidity all have a quantifiable effect on A-UO 3 crystallographic and morphological changes, relative humidity has the most significant impact.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The interplay between laser focusing conditions, expansion dynamics, ablation mechanisms, and emission intensity in ultrafast laser-produced plasmas

The interplay between ultrafast laser focusing conditions, emission intensity, expansion dynamics, and ablation mechanisms is critical to the detection of light isotopes relevant to nuclear energy, forensics, and geochemistry applications. Here, we study deuterium (2Hα) emission in plasmas generated from femtosecond laser ablation of a Zircaloy-4 target with a deuterium concentration of ≈37 at. %. Changes in emission intensity, plume morphology, crater dimensions, and surface modifications were investigated for varying focusing lens positions, where the laser was focused behind, at, and in front of the target. Spatially resolved optical emission spectroscopy and spectrally integrated plasma imaging were performed to investigate emission spectral features and plume morphology. Laser ablation crater dimensions and morphology were analyzed via optical profilometry and scanning electron microscopy. The 2Hα emission intensity showed significant reduction at the geometrical focal point or when the focal point is in front of the target. For all laser spot sizes, a two-component plume was observed but with different temporal histories. At the best focal point, the plume was spherical. When the laser was focused behind the target, the plume was elongated and propagated to farther distances than for the best focal position. In contrast, when the laser was focused in front of the target, filaments were generated in the beam path, and filament-plasma coupling occurred. By focusing the laser behind the target, the amount of material removal in the laser ablation process can be significantly reduced while still generating a plasma with a sufficient 2Hα emission signal for analysis.

Kautz, Elizabeth J. (ORCID:0000000263389223)↗