Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear spectral function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Atomic data and spectral line intensities for Ca IX

Electron impact collision strengths, energy levels, oscillator strengths, and spontaneous radiative decay rates are calculated for Ca IX. We include in the calculations the 33 lowest configurations in the n=3,4, and 5 complexes, corresponding to 283 fine-structure levels in the 3l3l{sup ′}, 3l4l{sup ″}, and 3l5l{sup ‴} configurations, where l,l{sup ′}=s,p,d, l{sup ″}=s,p,d,f and l{sup ‴}=s,p,d,f,g. Collision strengths are calculated at five incident energies for all transitions: 5.8, 13.6, 24.2, 38.6, and 57.9 Ry above the threshold of each transition. An additional energy, very close to the transition threshold, has been added, whose value is between 0.0055 Ry and 0.23 Ry depending on the levels involved. Calculations have been carried out using the Flexible Atomic Code and the distorted wave approximation. Excitation rate coefficients are calculated as a function of electron temperature by assuming a Maxwellian electron velocity distribution. Using the excitation rate coefficients and the radiative transition rates calculated in the present work, statistical equilibrium equations for level populations are solved at electron densities covering the range of 10{sup 8}–10{sup 14} cm{sup −3} and at an electron temperature of logT{sub e}(K)=5.8, corresponding to the maximum abundance of Ca IX. Spectral line intensities are calculated, and their diagnostic relevance is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Linearity for Ca2+-Doped CeBr3 Scintillating Materials

The Remote Sensing Laboratory (RSL) developed an aliovalently calcium-doped cerium tribromide (CeBr3:Ca2+) crystal with 3.2% resolution. RSL completed a crystal assessment, and Sandia National Laboratories calculated the predictive performance and physical characteristics using proven density functional theory (DFT) formalism. Results are reported for the work done to map the detector performance, characteristics, calcium doping concentration, and crystal strength. Preliminary scintillation measurements for this aliovalently calcium-doped CeBr3 scintillator exhibit a slight blue shift in fluorescence emission at 371 nm excitation for CeBr3. The structural, electronic, and optical properties of CeBr3 crystals were investigated using DFT within generalized gradient approximation. The calculated lattice parameters are in good agreement with the experimental data. The energy band structures and density of states were obtained. The optical properties of CeBr3, including the dielectric function, were calculated. Specifically, we report excellent linearity with the aliovalently calcium-doped CeBr3 crystal. Proportionality of light yield is one area of performance in which Ce-doped and Ce-based lanthanide halides excel. Maintaining proportionality is key to producing a strong, high-performance scintillator. Relative light yield proportionality was measured for both doped and undoped samples of CeBr3 to ensure no loss in performance was incurred during doping. The light output and proportionality, however, appear to be similar to CeBr3. There was a reduced yield at low energy. Relative light yield proportionality measurements suggest that dopants do not significantly affect proportionality at higher energies. RSL completed additional testing and evaluation of the new crystal and assessed benchmark spectroscopy measurements. Results, which present energy resolution as a function of energy, are summarized. Typical spectroscopy results using a 137Cs radiation source are shown for our crystallite. We obtain 4.5% for the packaged crystallite. More spectra are presented for 241Am, 60Co, 228Th, and background to exemplify CeBr3:Ca2+ over a broader energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The development and applications of multidimensional biomolecular spectroscopy illustrated by photosynthetic light harvesting

The parallel and synergistic developments of atomic resolution structural information, new spectroscopic methods, their underpinning formalism, and the application of sophisticated theoretical methods have led to a step function change in our understanding of photosynthetic light harvesting, the process by which photosynthetic organisms collect solar energy and supply it to their reaction centers to initiate the chemistry of photosynthesis. The new spectroscopic methods, in particular multidimensional spectroscopies, have enabled a transition from recording rates of processes to focusing on mechanism. We discuss two ultrafast spectroscopies – two-dimensional electronic spectroscopy and two-dimensional electronic-vibrational spectroscopy – and illustrate their development through the lens of photosynthetic light harvesting. Both spectroscopies provide enhanced spectral resolution and, in different ways, reveal pathways of energy flow and coherent oscillations which relate to the quantum mechanical mixing of, for example, electronic excitations (excitons) and nuclear motions. The new types of information present in these spectra provoked the application of sophisticated quantum dynamical theories to describe the temporal evolution of the spectra and provide new questions for experimental investigation. While multidimensional spectroscopies have applications in many other areas of science, we feel that the investigation of photosynthetic light harvesting has had the largest influence on the development of spectroscopic and theoretical methods for the study of quantum dynamics in biology, hence the focus of this review. We conclude with key questions for the next decade of this review.

59 BASIC BIOLOGICAL SCIENCES↗

Nature of lattice distortions in the cubic double perovskite Ba 2 NaOsO 6

In this paper, we present detailed calculations of the electric field gradient (EFG) using a point charge approximation in ${\mathrm{Ba}}_{2}{\mathrm{NaOsO}}_{6}$, a Mott insulator with strong spin-orbit interaction. Recent $^{23}\mathrm{Na}$ nuclear magnetic resonance (NMR) measurements found that the onset of local point symmetry breaking, likely caused by the formation of quadrupolar order [Chen, Pereira, and Balents, Phys. Rev. B 82, 174440 (2010)], precedes the formation of long range magnetic order in this compound [Lu et al., Nat. Commun. 8, 14407 (2017); Liu et al., Physica B 536, 863 (2018)]. An extension of the static $^{23}\mathrm{Na}$ NMR measurements as a function of the orientation of a 15 T applied magnetic field at 8 K in the magnetically ordered phase is reported. Broken local cubic symmetry induces a nonspherical electronic charge distribution around the Na site and thus finite EFG, affecting the NMR spectral shape. We combine the spectral analysis as a function of the orientation of the magnetic field with calculations of the EFG to determine the exact microscopic nature of the lattice distortions present in low temperature phases of this material. Finally, we establish that orthorhombic distortions, constrained along the cubic axes of the perovskite reference unit cell, of oxygen octahedra surrounding Na nuclei are present in the magnetic phase. Other common types of distortions often observed in oxide structures are considered as well.

36 MATERIALS SCIENCE↗

SPATIALLY RESOLVED STAR FORMATION HISTORY ALONG THE DISK OF M82 USING MULTI-BAND PHOTOMETRIC DATA

We present results on the star formation history and extinction in the disk of M82 over spatial scales of 10'' ({approx}180 pc). Multi-band photometric data covering the far-ultraviolet to the near-infrared bands were fitted to a grid of synthetic spectral energy distributions. We obtained distribution functions of age and extinction for each of the 117 apertures analyzed, taking into account observational errors through Monte Carlo simulations. These distribution functions were fitted with Gaussian functions to obtain the mean ages and extinctions together with their errors. The zones analyzed include the high surface brightness complexes defined by O'Connell and Mangano. We found that these complexes share the same star formation history and extinction as the field stellar populations in the disk. There is an indication that the stellar populations are marginally older at the outer disk (450 Myr at {approx}3 kpc) as compared to the inner disk (100 Myr at 0.5 kpc). For the nuclear region (radius less than 500 pc), we obtained an age of less than 10 Myr. The results obtained in this work are consistent with the idea that the 0.5-3 kpc part of the disk of M82 formed around 90% of the stellar mass in a star-forming episode that started around 450 Myr ago and lasted for about 350 Myr. We found that field stars are the major contributors to the flux over the spatial scales analyzed in this study, with the stellar cluster contribution being 7% in the nucleus and 0.7% in the disk.

79 ASTRONOMY AND ASTROPHYSICS↗

A semi-supervised learning method to produce explainable radioisotope proportion estimates for NaI-based synthetic and measured gamma spectra

Quantifying the radioactive sources present in gamma spectra is an ever-present and growing national security mission and a time-consuming process for human analysts. While machine learning models exist that are trained to estimate radioisotope proportions in gamma spectra, few address the eventual need to provide explanatory outputs beyond the estimation task. In this work, we develop two machine learning models for a NaI detector measurements: one to perform the estimation task, and the other to characterize the first model’s ability to provide reasonable estimates. To ensure the first model exhibits a behavior that can be characterized by the second model, the first model is trained using a custom, semi-supervised loss function which constrains proportion estimates to be explainable in terms of a spectral reconstruction. The second auxiliary model is an out-of-distribution detection function (a type of meta-model) leveraging the proportion estimates of the first model to identify when a spectrum is sufficiently unique from the training domain and thus is out-of-scope for the model. In demonstrating the efficacy of this approach, we encourage the use of meta-models to better explain ML outputs used in radiation detection and increase trust.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time Series Evaluation of Radiation Portal Monitor Data for Point Source Detection

The time series of data from a Radiation Portal Monitor (RPM) system are evaluated for the presence of point sources by isolating the contribution of anomalous radiation. Energy-windowed background spectra taken from the RPM are compared with the observed spectra at each time step during a vehicle drive-through. The total signal is turned into a spectral distance index using this method. This provides a time series with reduced systematic fluctuations due to background attenuation by the vehicle, and allows for point source detection by time-series analyses. The anomalous time series is reanalyzed by using a wavelet filter function of similar size to the expected source profile. A number of real drive-through data sets taken at a U.S. port of entry are analyzed in this way. A set of isotopes are injected into the data set, and the resultant benign and injected data sets are analyzed with gross-counting, spectral-ratio, and time-based algorithms. Spectral and time methods together offer a significant increase to detection performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Why the US Needs an Enduring Plutonium Critical Assembly

Jezebel (operated from 1954-1977) has been the primary experiment for fast 239 Pu nuclear data validation for the last 70 years. Validation has included not only k eff , but also spectral indicies, Rossi-α, reactivity coefficients, and neutron leakage spectra. While this has been incredibly valuable to the community, there are three major issues. The first issue is that documentation on many of these experiments were lacking, leading to large uncertainties or (even worse) incorrect assumptions. The second issue is that while there have been many advances in research, there is no way to test those new advances today. The last issue is that since the assembly only operated for 23 years (and at time when 30 other critical assemblies were operating at the same facility and nuclear weapons testing was occurring), there were limited opportunities to observe how any system parameters changed as a function of time. Note that this work is not suggesting that a "Jezebel re placement" used for a limited experiment campaign would have great value. A new enduring (100 year target) plutonium (Pu) assembly with simple geometry and low uncertainties, however, would be extremely valuable. Such a capability would have a transformative impact on many research areas including nuclear data validation, analytical methods validation, dosimetry, reactor kinetics, and materials. The need for a new plutonium assembly is not new: it has been in the DOE Nuclear Criticality Safety Program (NCSP) Mission and Vision for over 10 years and was also the top priority established at the 2022 National Criticality Experiments Research Center (NCERC) Futures meeting. This work will discuss how such a new capability would help ensure that the US retains international leadership in plutonium research. Last, a brief overview of Lilith, a project aimed to design a new enduring plutonium assembly for operation at the NCERC will be given.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dynamics of modulated beams in spectral domain

General formalism for describing dynamics of modulated beams along linear beamlines is developed. We describe modulated beams with spectral distribution function which represents Fourier transform of the conventional beam distribution function in the 6-dimensional phase space. The introduced spectral distribution function is localized in some region of the spectral domain for nearly monochromatic modulations. It can be characterized with a small number of typical parameters such as the lowest order moments of the spectral distribution. We study evolution of the modulated beams in linear beamlines and find that characteristic spectral parameters transform linearly. The developed approach significantly simplifies analysis of various schemes proposed for seeding X-ray free electron lasers. We use this approach to study several recently proposed schemes and find the bandwidth of the output bunching in each case.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-frequency analysis of non-stationary fusion plasma signals using an improved Hilbert-Huang transform

An improved Hilbert-Huang transform method is developed to the time-frequency analysis of non-stationary signals in tokamak plasmas. Maximal overlap discrete wavelet packet transform rather than wavelet packet transform is proposed as a preprocessor to decompose a signal into various narrow-band components. Then, a correlation coefficient based selection method is utilized to eliminate the irrelevant intrinsic mode functions obtained from empirical mode decomposition of those narrow-band components. Subsequently, a time varying vector autoregressive moving average model instead of Hilbert spectral analysis is performed to compute the Hilbert spectrum, i.e., a three-dimensional time-frequency distribution of the signal. The feasibility and effectiveness of the improved Hilbert-Huang transform method is demonstrated by analyzing a non-stationary simulated signal and actual experimental signals in fusion plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BROADBAND, TIME-DEPENDENT, SPECTROSCOPY OF THE BRIGHTEST BURSTS OBSERVED BY BATSE LAD AND EGRET TASC

The Energetic Gamma Ray Experiment Telescope (EGRET) calorimeter, Total Absorption Shower Counter (TASC), was triggered by the Burst And Transient Source Experiment (BATSE) and thus observed several bursts in the energy range of 1-200 MeV. The analysis of combined BATSE Large Area Detector and EGRET TASC data have been developed and discussed previously. Spectroscopy of GRB941017 based on this analysis uncovered an MeV component that would be hidden in the brightness of the synchrotron component in a time-integrated spectrum of the whole burst, while separation into shorter time intervals allowed a unique identification of a new component different from the synchrotron component. In this paper the spectral temporal evolution of the 68 brightest long BATSE bursts, in the broadest energy range yet reported, is studied using the analysis used for GRB941017. We consider the Band function to describe the spectra from keV to MeV energies. Only 21 of the 68 bursts showed MeV emission detectable by TASC. We observed three bursts that contained spectra with peak energy E {sub peak}>2 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Short-Range nuclear Correlations in light nuclei using the BeAGLE event generator

Nuclear dynamics at short distances among nucleons is one of the most outstanding phenomena in nuclear physics. Understanding the role of QCD in generating nuclear forces is important for uncovering the underlying physics of Short-Range Correlations (SRCs). In recent years, SRCs has been observed from light to heavy nuclei using fixed target experiments at Jefferson lab via high energy electron-nucleus scattering. In this talk, I will talk about the opportunity of studying SRCs using light nuclei with collider experiments, e.g., the Electron-Ion Collider (EIC). The experimental technique of studying the light nuclei can be based on exclusive processes with tagging final-state particles, in order to fully control the initial state of the target wavefunction. In particular, incoherent diffractive production of J/\psi J / ψ particle off deuteron will be presented. In addition, the spectral function in light nuclei has been recently modeled in the BeAGLE event generator, where the decay kinematics of the light nuclei and their influence on the very forward detector design at the EIC will be discussed.

Tu, Zhoudunming↗

Remote quantification of Cm(III) and HNO 3 by fluorescence spectroscopy and chemometrics

A unique approach to remotely quantify Cm(III) (0–100 µg mL −1 ) in HNO 3 (1–12 M) using steady-state laser fluorescence spectroscopy and multivariate regression models was developed. Photoluminescence is amenable to remote measurements using fiber-optic cables and is sensitive to numerous lanthanide and actinide species. In-line measurements can provide feedback to support complex processing in harsh environments (e.g., hot cells) to help guide and optimize radiochemical separations. In this work, Cm(III) spectra were acquired remotely in a glove box as a function of HNO 3 concentration to better understand spectral characteristics and evaluate the utility of multivariate regression models in this system. Furthermore, the Cm(III) fluorescence peak shape, width, position, and intensity changed significantly as a function of HNO 3 concentration, likely because of the displacement of emission quenching inner-sphere water molecules and complexation with nitrate ions. Despite significant covariance and nonlinearity in the data, a D-optimal design strategy successfully minimized training set sample size and was used to build effective partial least squares regression models for Cm(III) and HNO 3 concentrations without a priori knowledge of solution conditions. Chemometrics for modeling complex fluorescence spectra are promising and may find widespread applicability for online analysis in numerous chemical systems found in the nuclear field.

Actinide↗

Measuring the diffraction properties of an imaging quartz(211) crystal

A dual goniometer X-ray system was used to measure the reflectivity curve for a spherically bent quartz(211) crystal. An analysis of the dual goniometer instrument response function for the rocking curve width measurement was developed and tested against the actual measurements. The rocking curve was measured at 4510.8 eV using the Ti Kα1 characteristic spectral line. The crystal is the dispersion element for a high resolution spectrometer used for plasma studies. It was expected to have a very narrow rocking curve width. The analysis showed that we could measure the upper bound for the rocking curve width of the Qz(211) crystal. The upper bound was 58 μrad giving a lower bound for the instrument resolving power E/ΔE = 34 000. Greatly improved insight into the dual goniometer operation and its limitations was achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct solution of Minkowski-space Bethe-Salpeter equation in the massive Wick-Cutkosky model

Here in order to solve the Bethe-Salpeter equation (BSE) in the Minkowski space, we first introduce the Nakanishi integral representations of the Bethe-Salpeter amplitude and the Bethe-Salpeter wave function. We then derive the explicit integral equations for the corresponding spectral functions from the BSE for states of two scalar particles bound by a scalar-particle exchange interaction, where the propagators of constituents are allowed to be fully dressed. These integral equations are subsequently solved numerically in the variation of the Wick-Cutkosky model with massive exchange particles, where an algorithm of adaptive mash grid is proposed. The equations and algorithm we develop here serve as the foundation of Minkowski-space formulation of BSE for bound states of fermions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiation detector device for rejecting and excluding incomplete charge collection events

A radiation detector device is provided that is capable of distinguishing between full charge collection (FCC) events and incomplete charge collection (ICC) events based upon a correlation value comparison algorithm that compares correlation values calculated for individually sensed radiation detection events with a calibrated FCC event correlation function. The calibrated FCC event correlation function serves as a reference curve utilized by a correlation value comparison algorithm to determine whether a sensed radiation detection event fits the profile of the FCC event correlation function within the noise tolerances of the radiation detector device. If the radiation detection event is determined to be an ICC event, then the spectrum for the ICC event is rejected and excluded from inclusion in the radiation detector device spectral analyses. The radiation detector device also can calculate a performance factor to determine the efficacy of distinguishing between FCC and ICC events.

36 MATERIALS SCIENCE↗

ENDF/B-VII.1 Neutron Cross Section Data Testing with Critical Assembly Benchmarks and Reactor Experiments

The ENDF/B-VII.1 library is the latest revision to the United States' Evaluated Nuclear Data File (ENDF). The ENDF library is currently in its seventh generation, with ENDF/B-VII.0 being released in 2006. This revision expands upon that library, including the addition of new evaluated files (was 393 neutron files previously, now 418 including replacement of elemental vanadium and zinc evaluations with isotopic evaluations) and extension or updating of many existing neutron data files. Complete details are provided in the companion paper [1]. This paper focuses on how accurately application libraries may be expected to perform in criticality calculations with these data. Continuous energy cross section libraries, suitable for use with the MCNP Monte Carlo transport code, have been generated and applied to a suite of nearly one thousand critical benchmark assemblies defined in the International Criticality Safety Benchmark Evaluation Project's International Handbook of Evaluated Criticality Safety Benchmark Experiments. This suite covers uranium and plutonium fuel systems in a variety of forms such as metallic, oxide or solution, and under a variety of spectral conditions, including unmoderated (i.e., bare), metal reflected and water or other light element reflected. Assembly eigenvalues that were accurately predicted with ENDF/B-VII.0 cross sections such as unmoderated and uranium reflected 235U and 239Pu assemblies, HEU solution systems and LEU oxide lattice systems that mimic commercial PWR configurations continue to be accurately calculated with ENDF/B-VII.1 cross sections, and deficiencies in predicted eigenvalues for assemblies containing selected materials, including titanium, manganese, cadmium and tungsten are greatly reduced. Improvements are also confirmed for selected actinide reaction rates such as 236U capture. Other deficiencies, such as the overprediction of Pu solution system critical eigenvalues and a decreasing trend in calculated eigenvalue for 233U fueled systems as a function of Above-Thermal Fission Fraction remain. The comprehensive nature of this critical benchmark suite and the generally accurate calculated eigenvalues obtained with ENDF/B-VII.1 neutron cross sections support the conclusion that this is the most accurate general purpose ENDF/B cross section library yet released to the technical community.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Online monitoring of solutions within microfluidic chips: simultaneous Raman and UV-Vis absorption spectroscopies

Microfluidics is an appealing analytical tool in the global effort to close the nuclear fuel cycle. Using a microfluidic chip permits analysis of greatly reduced sample volumes compared to what is necessary for traditional analytical methods. There is a commensurate reduction in disposal volume and cost. Development of spectroscopic methods practicable on the microscale are necessary to take advantage of the microchip configuration. This study uses simultaneously applied UV-vis and micro-Raman spectroscopies adapted to function on the microscale to analyze in situ both the Nd3+ (UV-vis active) and HNO3 (Raman active) concentrations in the same sample. An adjustable translation platform was designed to hold the micro-Raman probe above and perpendicular to the chip face, and the UV-vis probe in the plane of the chip. These complimentary spectral techniques when processed through multivariate PLS (Partial Least Squares) models gave an accurate picture of the widely varying solution concentrations as a function of time for each solution component. Solution matrix effects can drastically alter analyte signatures as measured by both UV-vis absorbance and Raman spectroscopy. PLS methods successfully modeled these spectral changes and accurately measured concentrations of components of interest within the microfluidic chip.

on-line monitoring, microfluidics, Raman, UV-vis↗