Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical clock”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

A Generic High Bandwidth Data Acquisition Card for Physics Experiments

In high energy physics and nuclear physics experiments particularly the ones based on particle accelerator, the data rate from the detector is usually in the order of Terabytes per second. This high throughput data from detector front-end electronics need to be transmitted to the back-end computing farm for high level event selection and building. A Data Acquisition (DAQ) system with features of high-density, scalable, easily upgradeable is crucial to simplify the readout architecture of whole experiment. This paper will introduce the design of a generic high bandwidth PCIe card which can be used as the important input output card in a scalable DAQ system. It can factorize front-end electronics from data handling, and reduce amount of custom hardware in favor of scalable detectorindependent commercial hardware and software. Besides the 48 channels of bidirectional high speed fiber optical links with frontends, it also supports to synchronize with the experiment timing system, and to fanout the clock and trigger information with a fixed latency to the front-end electronics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Anticipated uncertainty budgets of PRARETIME and T2L2 techniques as applied to ExTRAS

The Experiment on Timing Ranging and Atmospheric Soundings, ExTRAS, was conceived jointly by the European Space Agency, ESA, and the Russian Space Agency, RSA. It is also designated the 'Hydrogen-maser in Space/Meteor-3M project'. The launch of the satellite is scheduled for early 1997. The package, to be flown on board a Russian meteorological satellite includes ultra-stable frequency and time sources, namely two active and auto-tuned hydrogen masers. Communication between the on-board hydrogen masers and the ground station clocks is effected by means of a microwave link using the modified version for time transfer of the Precise Range And Range-rate Equipment, PRARETIME, technique, and an optical link which uses the Time Transfer by Laser Link, T2L2, method. Both the PRARETIME and T2L2 techniques operate in a two-directional mode, which makes it possible to carry out accurate transmissions without precise knowledge of the satellite and station positions. Due to the exceptional quality of the on-board clocks and to the high performance of the communication techniques with the satellite, satellite clock monitoring and ground clocks synchronization are anticipated to be performed with uncertainties below 0.5 ns (1 sigma). Uncertainty budgets and related comments are presented.

Thomas, Claudine↗

A compact ultranarrow high-power laser system for experiments with 578 nm ytterbium clock transition

In this paper, we present the realization of a compact, high-power laser system able to excite the ytterbium clock transition at 578 nm. Starting from an external-cavity laser based on a quantum dot chip at 1156 nm with an intra-cavity electro-optic modulator, we were able to obtain up to 60 mW of visible light at 578 nm via frequency doubling. The laser is locked with a 500 kHz bandwidth to an ultra-low-expansion glass cavity stabilized at its zero coefficient of thermal expansion temperature through an original thermal insulation and correction system. This laser allowed the observation of the clock transition in fermionic {sup 173}Y b with a <50 Hz linewidth over 5 min, limited only by a residual frequency drift of some 0.1 Hz/s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Asynchronous Data Communication Via Fiber Optics

Transmitter and receiver devised for asynchronous digital communication via optical fiber at rates above 100 Mb/s. Transmitter converts parallel data to serial for high-speed transmission; receiver recovers clock signal and converts data back to parallel. No phase-lock loops used. New receiver design avoids over-sampling altogether. Local sampling oscillator operating nominally at clock frequency generates N clock signals of equally spaced phase, used to clock incoming data into N separate shift registers.

Bergman, Larry A.↗

Molecules Functionalized with Cycling Centers for Quantum Information Science

The ability for a single molecule to produce enough laser-induced fluorescence to control and detect its quantum state is known as optical cycling. This property has been used to great effect in atoms, where the relatively small number of states promotes their ability to repeatedly fluoresce, for applications such as laser cooling, precision measurement, atomic clocks, and quantum information processing. The extension of this capability to molecular species, however, has been difficult, primarily due to their propensity to become vibrationally excited during illumination. This project brought together experts from atomic physics, physical chemistry, and computational quantum chemistry to develop means to create molecules capable of optical cycling. In particular, this program sought to produce an optical cycling center (OCC), a quantum functional group capable of chemical attachment to a wide variety of molecular hosts while retaining (and thereby furnishing to its host) the ability to optically cycle. Following our team’s theoretical identification of promising species, including alkaline-earth phenoxides, we then created these species and in many cases confirmed their optical cycle closure. We now not only know of the existence of a handful of large, molecular species that can be deployed for applications in quantum technologies and measurement, but have improved our knowledge of the molecular mechanisms leading to this discovery, which will enable generalization in the future. The extension of these ideas for informed chemical design of cycling molecules with bespoke properties is now being pursued by multiple groups.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Cs vapor cell coated with octadecyltrichlorosilane using coherent population trapping spectroscopy

We report the realization and characterization using coherent population trapping (CPT) spectroscopy of an octadecyltrichlorosilane (OTS)-coated centimeter-scale Cs vapor cell. The dual-structure of the resonance lineshape, with presence of a narrow structure line at the top of a Doppler-broadened structure, is clearly observed. The linewidth of the narrow resonance is compared to the linewidth of an evacuated Cs cell and of a buffer gas Cs cell of similar size. The Cs-OTS adsorption energy is measured to be (0.42 ± 0.03) eV, leading to a clock frequency shift rate of 2.7 × 10{sup −9}/K in fractional unit. A hyperfine population lifetime, T{sub 1}, and a microwave coherence lifetime, T{sub 2}, of 1.6 and 0.5 ms are reported, corresponding to about 37 and 12 useful bounces, respectively. Atomic-motion induced Ramsey narrowing of dark resonances is observed in Cs-OTS cells by reducing the optical beam diameter. Ramsey CPT fringes are detected using a pulsed CPT interrogation scheme. Potential applications of the Cs-OTS cell to the development of a vapor cell atomic clock are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of trapped-ion heating on generalised Ramsey methods for suppressing frequency shifts caused by a probe field in atomic clocks

Based on a simple one-dimensional model, we consider the effect of trapped-ion heating on the efficiency of generalised Ramsey methods for the probe-induced frequency shift suppression in optical frequency standards based on single ultracold ions. It is shown that ion heating reduces the efficiency of all previously proposed one-loop generalised Ramsey methods, leading in all cases to the appearance of a linear dependence of the reference frequency shift on the residual field frequency shift. Two versions of the most heating stable generalised Ramsey schemes, for which the proportionality coefficient in this dependence is minimal, are demonstrated. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Final report on LDRD project : narrow-linewidth VCSELs for atomic microsystems.

Vertical-cavity surface-emitting lasers (VCSELs) are well suited for emerging photonic microsystems due to their low power consumption, ease of integration with other optical components, and single frequency operation. However, the typical VCSEL linewidth of 100 MHz is approximately ten times wider than the natural linewidth of atoms used in atomic beam clocks and trapped atom research, which degrades or completely destroys performance in those systems. This report documents our efforts to reduce VCSEL linewidths below 10 MHz to meet the needs of advanced sub-Doppler atomic microsystems, such as cold-atom traps. We have investigated two complementary approaches to reduce VCSEL linewidth: (A) increasing the laser-cavity quality factor, and (B) decreasing the linewidth enhancement factor (alpha) of the optical gain medium. We have developed two new VCSEL devices that achieved increased cavity quality factors: (1) all-semiconductor extended-cavity VCSELs, and (2) micro-external-cavity surface-emitting lasers (MECSELs). These new VCSEL devices have demonstrated linewidths below 10 MHz, and linewidths below 1 MHz seem feasible with further optimization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A sub-picosecond digital clock monitoring system

We describe a low-cost system designed to monitor wander in digital clocks with a precision of ≤ 1 ps. With this system we have shown that it is possible to track phase variations at the sub-picosecond level by adding noise to a reference clock. As in many cases where a clock is part of a complex distribution network small changes in temperature and other effects can lead to small changes in the clock's phase. As a further demonstration of the system, we have used it to measure the phase changes induced in optical signals in fibers.

47 OTHER INSTRUMENTATION↗

Astigmatism-free 3D optical tweezer control for rapid atom rearrangement

Reconfigurable neutral-atom arrays are a promising platform for quantum computing, quantum simulation, and quantum metrology, but atom transport using frequency-chirped acousto-optic deflectors (AODs) is limited by chirp-induced acoustic lensing and trajectory distortion. We address these limitations using a three-dimensional acousto-optic deflector lens (3D-AODL), a design predicted to reduce long-range transport times by more than a factor of two. We further introduce fading-Shepard waveforms that circumvent finite AOD bandwidth, enabling sustained axial displacement. We demonstrate unrestricted three-dimensional optical-tweezer motion over a 200 μm × 200 μm × 136 μm volume with velocities exceeding 4.2 m/s. Arbitrary three-dimensional control of optical-tweezer trajectories enables rapid atom rearrangement and dynamical engineering of optical potentials in tweezer arrays and optical lattices. This capability advances quantum control and atom manipulation in neutral-atom quantum processors by enabling faster rearrangement, higher clock rates, and scalable sorting in complex geometries.

Lu, Yue-Hui [University of California, Berkeley, C↗

Phase-lock-loop application for fiber optic receiver

Phase-locked loop circuits are frequently employed in communication systems. In recent years, digital phase-locked loop circuits were utilized in optical communications systems. In an optical transceiver system, the digital phase-locked loop circuit is connected to the output of the receiver to extract a clock signal from the received coded data (NRZ, Bi-Phase, or Manchester). The clock signal is then used to reconstruct or recover the original data from the coded data. A theoretical approach to the design of a digital phase-locked loop circuit operation at 1 and 50 MHz is described. Hardware implementation of a breadboard design to function at 1 MHz and a printed-circuit board designed to function at 50 MHz were assembled using emitter coupled logic (ECL) to verify experimentally the theoretical design.

Ruggles, Stephen L.↗

Word timing recovery in direct detection optical PPM communication systems with avalanche photodiodes using a phase lock loop

A technique for word timing recovery in a direct-detection optical PPM communication system is described. It tracks on back-to-back pulse pairs in the received random PPM data sequences with the use of a phase locked loop. The experimental system consisted of an 833-nm AlGaAs laser diode transmitter and a silicon avalanche photodiode photodetector, and it used Q = 4 PPM signaling at source data rate 25 Mb/s. The mathematical model developed to describe system performance is shown to be in good agreement with the experimental measurements. Use of this recovered PPM word clock with a slot clock recovery system caused no measurable penalty in receiver sensitivity. The completely self-synchronized receiver was capable of acquiring and maintaining both slot and word synchronizations for input optical signal levels as low as 20 average detected photons per information bit. The receiver achieved a bit error probability of 10 to the -6th at less than 60 average detected photons per information bit.

Sun, Xiaoli↗

Suppressing Loss of Ions in an Atomic Clock

An improvement has been made in the design of a compact, highly stable mercury- ion clock to suppress a loss of ions as they are transferred between the quadrupole and higher multipole ion traps. Such clocks are being developed for use aboard spacecraft for navigation and planetary radio science. The modification is also applicable to ion clocks operating on Earth: indeed, the success of the modification has been demonstrated in construction and operation of a terrestrial breadboard prototype of the compact, highly stable mercury-ion clock. Selected aspects of the breadboard prototype at different stages of development were described in previous NASA Tech Briefs articles. The following background information is reviewed from previous articles: In this clock as in some prior ion clocks, mercury ions are shuttled between two ion traps, one a 16- pole linear radio-frequency trap, while the other is a quadrupole radio-frequency trap. In the quadrupole trap, ions are tightly confined and optical state selection from a 202Hg lamp is carried out. In the 16-pole trap, the ions are more loosely confined and atomic transitions are interrogated by use of a microwave beam at approximately 40.507 GHz. The trapping of ions effectively eliminates the frequency pulling that would otherwise be caused by collisions between clock atoms and the wall of a gas cell. The shuttling of the ions between the two traps enables separation of the state-selection process from the clock microwave-resonance process, so that each of these processes can be optimized independently of the other. This is similar to the operation of an atomic beam clock, except that with ions the beam can be halted and reversed as ions are shuttled back and forth between the two traps. When the two traps are driven at the same radio frequency, the strength of confinement can be reduced near the junction between the two traps, depending upon the relative phase of the RF voltage used to operate each of the two traps, and can cause loss of ions during each transit between the traps and thereby cause loss of the 40.507-GHz ion-clock resonance signal. The essence of the modification is to drive the two traps at different frequencies typically between 1.5 and 2 MHz for the quadrupole trap and a frequency a few hundred kHz higher for the 16- pole trap. A frequency difference of a few hundred kHz ensures that the ion motion caused by the trapping electric fields is small relative to the diameter of the traps. Unlike in the case in which both traps are driven at the same frequency, the trapping electric fields near the junction are not zero at all times; instead, the regions of low electric field near the junction open and close at the difference frequency. An additional benefit of making the 16-pole trap operate at higher frequency is that the strength or depth of the multipole trap can be increased independent of the quadrupole ion trap.

Prestage, John↗

Selective laser pumping of magnetic sublevels in the hyperfine structure of the cesium atom

The evolution of the populations of the magnetic sublevels of the cesium atom ({sup 133}Cs isotope) in resonant laser fields with linear polarization is analyzed using the equations for the density matrix. Analytic expressions are derived for stationary populations resulting from laser-induced optical transitions on the hyperfine structure components F{sub g} = 3 ↔ F{sub e} = 2, 3 and F{sub f} = 4 ↔ F{sub e} = 3, 4 of lines D{sub 1} (6{sup 2}S{sub 1/2} → 6{sup 2}P{sub 1/2}) and D{sub 2} (6{sup 2}S{sub 1/2} → 6{sup 2}P{sub 3/2}) depending on the initial values of the populations. The numerical solution of the evolution equations gives the characteristic times of stabilization of the steady regime as functions of laser field intensities and detuning from optical resonance. We determine the sequences of optical transitions increasing (by more than an order of magnitude) the population of the lower sublevel 6{sup 2}S{sub 1/2}F{sub g} = 3 M = 0 of the “clock” microwave transition F{sub g} = 3 M = 0 ↔ F{sub f} = 4 M = 0 in the cesium frequency standard, which increases the signal intensity in the recording system by the same proportion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Note: Optical receiver system for 152-channel magnetoencephalography

An optical receiver system composing 13 serial data restore/synchronizer modules and a single module combiner converted optical 32-bit serial data into 32-bit synchronous parallel data for a computer to acquire 152-channel magnetoencephalography (MEG) signals. A serial data restore/synchronizer module identified 32-bit channel-voltage bits from 48-bit streaming serial data, and then consecutively reproduced 13 times of 32-bit serial data, acting in a synchronous clock. After selecting a single among 13 reproduced data in each module, a module combiner converted it into 32-bit parallel data, which were carried to 32-port digital input board in a computer. When the receiver system together with optical transmitters were applied to 152-channel superconducting quantum interference device sensors, this MEG system maintained a field noise level of 3 fT/√Hz @ 100 Hz at a sample rate of 1 kSample/s per channel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compensation of residual amplitude modulation fluctuations in an optoelectronic system for laser radiation frequency stabilisation

Fluctuations of residual amplitude modulation in a scheme of laser frequency stabilisation by a Fabry – Perot cavity reduce the frequency stability of the laser systems intended for interrogating clock transitions of atoms and ions. The dependences of the residual amplitude modulation on a temperature of the waveguide-based electro-optical modulator used for modulating the radiation phase and on polarisation of the radiation are measured. The parameters are found, at which the influence of the residual amplitude modulation on the frequency stability is minimal. A system for active compensation is created, which reduces the contribution of fluctuations of residual amplitude modulation to the instability down to 2.1 × 10{sup −16}, which makes it possible to reach the thermal noise limit of a silicon cryogenic cavity. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Vanadium spin qubits as telecom quantum emitters in silicon carbide

Solid-state quantum emitters with spin registers are promising platforms for quantum communication, yet few emit in the narrow telecom band necessary for low-loss fiber networks. Here, we create and isolate near-surface single vanadium dopants in silicon carbide (SiC) with stable and narrow emission in the O band, with brightness allowing cavity-free detection in a wafer-scale material. In vanadium ensembles, we characterize the complex d 1 orbital physics in all five available sites in 4H-SiC and 6H-SiC. The optical transitions are sensitive to mass shifts from local silicon and carbon isotopes, enabling optically resolved nuclear spin registers. Optically detected magnetic resonance in the ground and excited orbital states reveals a variety of hyperfine interactions with the vanadium nuclear spin and clock transitions for quantum memories. Last, we demonstrate coherent quantum control of the spin state. These results provide a path for telecom emitters in the solid state for quantum applications.

74 ATOMIC AND MOLECULAR PHYSICS↗