Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical interference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Anomalous neutron nuclear-magnetic interference spectroscopy

The electron–phonon interaction plays a critical role in materials’ electrical, thermal, optical, and superconducting properties. However, measuring the phonon mode-resolved electron–phonon interaction has been challenging. Here we propose neutron-scattering-based Anomalous Neutron nUclear-Magnetic Interference Spectroscopy (ANUBIS), where the co-existence of neutron nuclear scattering and magnetic scattering leads to anomalous dynamical structure factor under the presence of the electron–phonon interaction. Such anomalous structure factor is linear in electron–phonon coupling constant at the phonon wavevector, and is directly proportional to the momentum and energy-resolved dielectric function. The experimental configuration can be achieved using existing polarized inelastic neutron scattering setup, and an order-of-magnitude estimate shows the viability to observe the anomalous scattering signal is around to 10 –4 to 10 –3 relative to phonon scattering, which is examined through the preliminary experiments and achievable at emerging neutron facilities. As a result, our proposal offers an alternative neutron-based metrology to probe the crucial electronic properties.

Electron-phonon interactions↗

Status Update on the Development of Transducers and Bonding Techniques for Enabling Acoustic Measurements of Damage in Microreactor Components

This report provides an overview of potential sensors and sensor-bonding techniques to enable the online acoustic interrogation of microreactor components and enhance structural health monitoring capabilities. The report focuses primarily on optical fiber–based acoustic sensors and describes initial experimental progress toward the deployment of these sensors for microreactor applications. The general approach is to monitor the resonant frequencies of microreactor components and search for evidence of structural defects that could indicate imminent failure. If properly identified, then the components could be repaired during the next reactor outage to prevent costly unplanned shutdowns. The ability to monitor the structural health of components could also reduce the need for time-consuming visual inspections and reduce staffing to improve microreactor economic viability. Increased sensor density is also one of the first steps to moving toward eventual semiautonomous operation. The expected microreactor conditions in which acoustic sensors must survive are characterized, including temperatures, neutron fluences, thermomechanical strains, and vibrational frequencies. Optical fiber–based acoustic sensors are identified as an attractive candidate for acoustic monitoring because of their high accuracy, immunity to electromagnetic interference, and resiliency in high-temperature, high-radiation environments. Optical fiber–based intrinsic sensors, such as type-II fiber-Bragg gratings and Fabry-Pérot Cavities (FPCs), are particularly attractive for a microreactor environment because of their high temperature stability, and FPCs also enable higher frequency interrogation with a lower sensitivity to radiation-induced drift. This report describes multiple interrogation systems, but the best interrogation system for a given situation will depend on the specific microreactor application, including the desired acoustic vibrational amplitudes, modes, and resonant frequencies. Initial experiments included fabricating three FPCs, tack-welding these FPCs to stainless-steel pipes or rods and performing room-temperature acoustic sensing tests to capture the vibrational frequency content. Peaks were identified in the measured frequency spectra and compared with the theoretical fundamental frequencies obtained from Euler-Bernoulli beam theory. Two of the three FPCs measured vibrational frequencies that generally matched those obtained from theory. Future work will include similar testing on pipes or other microreactor components with intentional flaws to evaluate the ability to determine changes in resonant frequencies. Finally, these tests will be repeated at high temperatures, potentially with an applied thermomechanical stress, to include environmental conditions similar to those for a microreactor application.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SeaWiFS Postlaunch Technical Report Series: The SeaWiFS Transfer Radiometer (SXR) - Volume 1

The SeaWiFS Transfer Radiometer (SXR) was built for the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Project as part of an Interagency Agreement with the National Aeronautics and Space Administration (NASA). The SXR is a multichannel radiometer designed to verify and compare measurements of spectral radiance at six discrete wavelengths in the visible and near infrared for various calibration sources in the SeaWiFS Project. In addition, the SXR is used to compare these sources to standards of spectral radiance maintained at the National Institute of Standards and Technology (NIST). The SXR was designed, built, and thoroughly characterized in the Optical Technology Division at NIST. A unique optical design provides six independent optical paths, each equipped with a temperature stabilized interference filter and silicon photodiode. A separate beam path through the input lens is used to visually align the SXR. The entrance windows for each channel overlap at the source, with each channel sampling a unique solid angle within the field of view of the SXR; this allows for simultaneous sampling of all channels. The combined standard relative uncertainty of spectral radiance measurements with the SXR is estimated to be between 0.6% and 1.3%. This report describes the design and construction of the SXR in detail, and gives the results of the optical characterization and calibrations done at NIST. The SXR has been used for several intercomparisons which include several SeaWiFS Intercalibration Round-Robin Experiments (SIRREXs); those done at the Marine Optical Buoy (MOBY) laboratories in Honolulu, Hawaii; at the NEC Corporation in Yokohama, Japan; and Orbital Sciences Corporation (OSC) in Germantown, Maryland. Thorough optical characterization and calibration of the SXR was essential to the successful application of the radiometer for these measurements.

Johnson, B. Carol↗

SeaWiFS Postlaunch Technical Report Series: The SeaWiFS Transfer Radiometer (SXR) - Volume 1

The SeaWiFS Transfer Radiometer (SXR) was built for the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Project as part of an Interagency Agreement with the National Aeronautics and Space Administration (NASA). The SXR is a multichannel radiometer designed to verify and compare measurements of spectral radiance at six discrete wavelengths in the visible and near infrared for various calibration sources in the SeaWiFS Project. In addition, the SXR is used to compare these sources to standards of spectral radiance maintained at the National Institute of Standards and Technology (NIST). The SXR was designed, built, and thoroughly characterized in the Optical Technology Division at NIST. A unique optical design provides six independent optical paths, each equipped with a temperature stabilized interference filter and silicon photodiode. A separate beam path through the input lens is used to visually align the SXR. The entrance windows for each channel overlap at the source, with each channel sampling a unique solid angle within the field of view of the SXR; this allows for simultaneous sampling of all channels. The combined standard relative uncertainty of spectral radiance measurements with the SXR is estimated to be between 0.6% and 1.3%. This report describes the design and construction of the SXR in detail, and gives the results of the optical characterization and calibrations done at NIST. The SXR has been used for several intercomparisons which include several SeaWiFS Intercalibration Round-Robin Experiments (SIRREXs); those done at the Marine Optical Buoy (MOBY) laboratories in Honolulu, Hawaii; at the NEC Corporation in Yokohama, Japan; and Orbital Sciences Corporation (OSC) in Germantown, Maryland. Thorough optical characterization and calibration of the SXR was essential to the successful application of the radiometer for these measurements.

Hooker, Stanford B.↗

Fiber-Optic Bolometer and Calorimeter Arrays for Magnetically Confined Plasmas Final Technical Report

Exhaust control is critical for sustained and safe operation of magnetic confinement fusion (MCF), which requires bolometers to measure the radiations converted from the exhaust power. Traditional bolometers are based on a radiation absorber and a resistive temperature sensor and their performance is greatly compromised by the strong electromagnetic interference (EMI). Previously, we have demonstrated a fiber-optic bolometer that has the promise to overcome the challenges related to the strong EMI in the MCF environment. However, it shows relatively large noise that limits its usefulness in MCF applications. In this project, we reduced the noise by more than 20 times through novel sensor design and signal demodulation. The availability of such bolometers will help to better understand and control the exhaust control strategies in MCF. The original project duration was three years. Because the PI moved to another institution on 1/1/2018, the project was closed after four months and a new grant was awarded to the PI in his new institution to continue the work.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sequence Detection for PPM Optical Communication With ISI

A method of sequence detection has been proposed to mitigate the effects of inter-slot interference and inter-symbol interference (both denoted ISI) in the reception of M-ary pulse-position modulation (PPM) optical signals. The method would make it possible to reduce the error rate for a given slot duration, to use a shorter slot duration (and, hence, to communicate at a higher rate) without exceeding a given error rate, or to use a lower-bandwidth (and, hence, less-expensive) receiver to receive a signal of a given slot width without exceeding a given error rate. In M-ary PPM, a symbol period is divided into M time slots, each of duration T(sub s), and a symbol consists of a binary sequence ones and zeros represented by pulses or the absence of pulses, respectively, in the time slots. At the transmitter, the bit stream is used to modulate a laser, the output of which is constant (either full power or zero power, representing 1 or 0, respectively) during each time slot. However, the signal becomes attenuated (signal photons are lost) in propagation from the transmitter to the receiver and noise enters at the receiver, complicating the problem of determining the timing of the symbol periods and slots and identifying the symbols.

Moision, Bruce↗

Properties of R136a as derived from its optical light distribution

Short exposure 4 m prime focus plates taken with interference filters centered on blue continuum 4765 A, He II 4686 line, red continuum 6485 A, and H-alpha line have been used to study the light distribution within R136a. R136a contains a bright component and several fainter components superposed on an extended background. The brightest component, unresolved under sub-arcsec seeing condition, contributes about 37 percent of the total light from a 3 in. diameter aperture. Combining the optical and UV information, it is found that this brightest component R136a1 may be a single star with a mass of approximately 750 solar masses with a brightness of six HD 93129A or 20 O3 V stars, or it could be a cluster of such stars. In either case, R136a1 supplies no more than one-half of the ionization of the 30 Doradus nebula.

Chu, Y.-H.↗

Optical Tweezer Assembly and Calibration

An Optical Tweezer, as the name implies, is a useful tool for precision manipulation of micro and nano scale objects. Using the principle of electromagnetic radiation pressure, an optical tweezer employs a tightly focused laser beam to trap and position objects of various shapes and sizes. These devices can trap micrometer and nanometer sized objects. An exciting possibility for optical tweezers is its future potential to manipulate and assemble micro and nano sized sensors. A typical optical tweezer makes use of the following components: laser, mirrors, lenses, a high quality microscope, stage, Charge Coupled Device (CCD) camera, TV monitor and Position Sensitive Detectors (PSDs). The laser wavelength employed is typically in the visible or infrared spectrum. The laser beam is directed via mirrors and lenses into the microscope. It is then tightly focused by a high magnification, high numerical aperture microscope objective into the sample slide, which is mounted on a translating stage. The sample slide contains a sealed, small volume of fluid that the objects are suspended in. The most common objects trapped by optical tweezers are dielectric spheres. When trapped, a sphere will literally snap into and center itself in the laser beam. The PSD s are mounted in such a way to receive the backscatter after the beam has passed through the trap. PSD s used with the Differential Interference Contrast (DIC) technique provide highly precise data. Most optical tweezers employ lasers with power levels ranging from 10 to 100 miliwatts. Typical forces exerted on trapped objects are in the pico-newton range. When PSDs are employed, object movement can be resolved on a nanometer scale in a time range of milliseconds. Such accuracy, however, can only by utilized by calibrating the optical tweezer. Fortunately, an optical tweezer can be modeled accurately as a simple spring. This allows Hook s Law to be used. My goal this summer at NASA Glenn Research Center is the assembly and calibration of an optical tweezer setup in the Instrumentation and Controls Division (5520). I am utilizing a custom LabVIEW Virtual Instrument program for data collection and microscope stage control. Helping me in my assignment are the following people: Mentor Susan Wrbanek (5520), Dr. Baha Jassemnejad (UCO) and Technicians Ken Weiland (7650) and James Williams (7650). Without their help, my task would not be possible.

Collins, Timothy M.↗

Robust Quantum Control via Multipath Interference for Thousandfold Phase Amplification in a Resonant Atom Interferometer

We introduce a novel technique for enhancing the robustness of light-pulse atom interferometers against the pulse infidelities that typically limit their sensitivities. The technique uses quantum optimal control to favorably harness the multipath interference of the stray trajectories produced by imperfect atom-optics operations. We apply this method to a resonant atom interferometer and achieve thousandfold phase amplification, representing a 50-fold improvement over the performance observed without optimized control. Moreover, we find that spurious interference can arise from the interplay of spontaneous emission and many-pulse sequences and demonstrate optimization strategies to mitigate this effect. Given the ubiquity of spontaneous emission in quantum systems, these results may be valuable for improving the performance of a diverse array of quantum sensors. We anticipate our findings will significantly benefit the performance of matter-wave interferometers for a variety of applications, including dark matter, dark energy, and gravitational wave detection.

47 OTHER INSTRUMENTATION↗

Coupled-Resonator-Induced Transparency

We demonstrate that a cancellation of absorption occurs on resonance for two (or any even number of) coupled optical resonators, due to mode splitting and classical destructive interference, particularly when the resonator finesse is large and the loss in the resonator furthest from the excitation waveguide is small. The linewidth and group velocity of a collection of such coupled-resonator structures may be decreased by using larger resonators of equal size, using larger resonators of unequal size where the optical path length of the larger resonator is an integer multiple of that of the smaller one, or by using a larger number of resonators per structure. We explore the analogy between these effects and electromagnetically induced transparency in an atomic system.

Smith, David D.↗

Light Confinement in Twisted Single-Layer 2D+ Moiré Photonic Crystals and Bilayer Moiré Photonic Crystals

Twisted photonic crystals are photonic analogs of twisted monolayer materials such as graphene and their optical property studies are still in their infancy. This paper reports optical properties of twisted single-layer 2D+ moiré photonic crystals where there is a weak modulation in z direction, and bilayer moiré-overlapping-moiré photonic crystals. In weak-coupling bilayer moiré-overlapping-moiré photonic crystals, the light source is less localized with an increasing twist angle, similar to the results reported by the Harvard research group in References 37 and 38 on twisted bilayer photonic crystals, although there is a gradient pattern in the former case. In a strong-coupling case, however, the light source is tightly localized in AA-stacked region in bilayer PhCs with a large twist angle. For single-layer 2D+ moiré photonic crystals, the light source in Ex polarization can be localized and forms resonance modes when the single-layer 2D+ moiré photonic crystal is integrated on a glass substrate. This study leads to a potential application of 2D+ moiré photonic crystal in future on-chip optoelectronic integration.

36 MATERIALS SCIENCE↗

Research plan for the development of optical fiber pressure sensors for nuclear applications

Fiber optic pressure sensors are desirable for nuclear applications because they are low mass/small size, immune to electromagnetic interference, high sensitivity, and have multiplexing and multimodal measurement capabilities. Much research and development has been conducted on developing fiber optic based sensors and they are now considered a class of standard instrumentation in many industries. Specifically, for pressure sensing, a wide range of fiber based sensors have been developed for various pressure ranges and environments. This vast body of research will be leveraged for the development of pressure sensors for nuclear applications. Four pressure measurement scenarios were considered which would benefit from a fiber optic based pressure sensor. These scenarios include pressure measurement in the fuel rod plenum, coolant pressure during LOCA testing, advanced coolant (helium, sodium, molten salt) pressure for flow loop operation, and high pressures resulting for direct fuel-coolant interaction. Each scenario has unique pressure, temperature, and material requirements for the sensor. From a survey of commercially available sensors and a literature review; it has been determined that an extrinsic Fabry-Perot interferometer approach is the most appropriate for the various measurement requirements. The experience and knowledge base for Fabry-Perot interferometers can be leveraged since they are the most common fiber optic based pressure sensors available commercially and found in literature. These pressure sensors rely on the interference of light in a gas filled cavity, which minimizes the impact of radiation induced attenuation and compaction on the measurement, compared to intrinsic sensing techniques. The measurement range of these sensors is based on the stiffness of the diaphragm that deflects under pressure. This allows for a suite of fiber based sensors to be developed by interchanging this diaphragm for the requirements of each application. Key material and design considerations have been identified for the development of a Fabry-Perot interferometry pressure measurement for nuclear applications. These include high temperature bonding between the glass fiber optic and metal housing, identifying diaphragm materials & geometry, and minimizing cross sensitivity to temperature or implementing compensation techniques found in literature. Overcoming these challenges will develop a pathway for a fiber optic based pressure sensor for nuclear applications, and additionally can be leveraged for other sensing application based on Fabry-Perot interferometers, such as temperature, strain (creep & deformation), vibration, and index of refraction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Real time pre-detection dynamic range compression

A real time, pre-detection optical dynamic range compression system uses a photorefractive crystal, such as BaTiO3 or LiNbO3, in which light induced scattering from crystal inhomogeneities of the optical input occurs as a nonlinear function of the input intensity. The greater the intensity, the faster random interference gratings are created to scatter the incident light. The unscattered portion of the optical signal is therefore reduced in dynamic range over time. The amount or range of dynamic range compression may be controlled by adjusting the time of application of the unscattered crystal output to the photodetector with regard to the time of application of the optical input to the crystal.

Liu, Hua-Kuang↗

Mitigation of Laser Beam Scintillation in Free-Space Optical Communication Systems Through Coherence-Reducing Optical Materials

Free-space optical communication systems (also known as lasercom systems) offer several performance advantages over traditional radio frequency communication systems. These advantages include increased data rates and reduced operating power and system weight. One serious limiting factor in a lasercom system is Optical turbulence in Earth's atmosphere. This turbulence breaks up the laser beam used to transmit the information into multiple segments that interfere with each other when the beam is focused onto the receiver. This interference pattern at the receiver changes with time causing fluctuations in the received optical intensity (scintillation). Scintillation leads to intermittent losses of the signal and an overall reduction in the lasercom system's performance. Since scintillation is a coherent effect, reducing the spatial and temporal coherence of the laser beam will reduce the scintillation. Transmitting a laser beam through certain materials is thought to reduce its coherence. Materials that were tested included: sapphire, BK7 glass, fused silica and others. The spatial and temporal coherence of the laser beam was determined by examining the interference patterns (fringes) it formed when interacting with various interferometers and etalons.

Renner, Christoffer J.↗

Analysis of Different Contributions into the Magnetooptical Signal of Magnetophotonic Crystal Type Three-Dimensional Structures

Interference of effects of different levels and magnitudes in producing a net magnetooptical response was considered for the first time in structures similar to magnetophotonic crystals at different wavelengths of the incident irradiation in regions far from plasmon resonances. Contributions of interference and diffraction phenomena in maxima of different orders in three-dimensional systems of the magnetophotonic crystal type were studied. Use of the integral response in the analysis of the magnetooptical effects was shown to lead to disappearing of the interference phenomena. The zero-order diffraction maximum reflects adequately the magnetic component of the magnetooptical response. Numerical estimates of the observed diffraction and interference effects are reported.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accelerated microwave-assisted synthesis and in situ X-ray scattering of tungsten-substituted vanadium dioxide (V 1-x W x O 2 )

Vanadium dioxide (VO 2 ) has been widely studied due to its metal-insulator phase transition at 68°C, below which it is a semiconducting monoclinic phase, P2 1 /c, and above it is a metallic tetragonal phase, P4 2 /mnm. Substituting vanadium with transition metals allows transition temperature tunability. An accelerated microwave-assisted synthesis for VO 2 and 5d tungsten substituted VO 2 presented herein decreased synthesis time by three orders of magnitude while maintaining phase purity, particle size, and transition character. Tungsten substitution amount was determined using inductively coupled plasma-optical emission spectroscopy. Differential scanning calorimetry, superconducting quantum interference device measurements, and in-situ heating and cooling experiments monitored through synchrotron x-ray diffraction (XRD) confirmed the transition temperature decreased with increased tungsten substitution. Scanning electron microscopy analyzed through the line-intercept method produced an average particle size of 3 – 5 μm. Average structure and local structure phase purity was determined through Rietveld analysis of synchrotron XRD and least-squares refinement of pair-distribution function data.

36 MATERIALS SCIENCE↗

Fiber-optic proximity sensor

Proximity sensor for mechanical hand of remote manipulator incorporates fiber optics to conduct signals between light source and light detector. Fiber optics are not prone to noise from electromagnetic interference and radio-frequency interference as are sensors using long electrical cables.

Bejczy, A. K.↗