Search NASA⌕ Search

SEARCH · Search NASA

Results for “oxygenated functionalities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Functional Performance of an Enabling Atmosphere Revitalization Subsystem Architecture for Deep Space Exploration Missions

A subsystem architecture derived from the International Space Station's (ISS) Atmosphere Revitalization Subsystem (ARS) has been functionally demonstrated. This ISS-derived architecture features re-arranged unit operations for trace contaminant control and carbon dioxide removal functions, a methane purification component as a precursor to enhance resource recovery over ISS capability, operational modifications to a water electrolysis-based oxygen generation assembly, and an alternative major atmospheric constituent monitoring concept. Results from this functional demonstration are summarized and compared to the performance observed during ground-based testing conducted on an ISS-like subsystem architecture. Considerations for further subsystem architecture and process technology development are discussed.

Perry, Jay L.↗

The kinetic chemistry of dense interstellar clouds

A model of the time-dependent chemistry of dense interstellar clouds is formulated to study the dominant chemical processes in carbon and oxygen isotope fractionation, the formation of nitrogen-containing molecules, and the evolution of product molecules as a function of cloud density and temperature. The abundances of the dominant isotopes of the carbon- and oxygen-bearing molecules are calculated. The chemical abundances are found to be quite sensitive to electron concentration since the electron concentration determines the ratio of H3(+) to He(+), and the electron density is strongly influenced by the metals abundance. For typical metal abundances and for H2 cloud density not less than 10,000 molecules/cu cm, nearly all carbon exists as CO at late cloud ages. At high cloud density, many aspects of the chemistry are strongly time dependent. Finally, model calculations agree well with abundances deduced from observations of molecular line emission in cold dense clouds.

Graedel, T. E.↗

Breathing metabolic simulator

The development of a breathing metabolic simulator (BMS) is reported. This BMS simulates all of the breathing and metabolic parameters required for complete evaluation and test of life support and resuscitation equipment. It is also useful for calibrating and validating mechanical and gaseous pulmonary function test procedures. Breathing rate, breathing depth, breath velocity contour, oxygen uptake, and carbon dioxide release are all variable over wide ranges simulating conditions from sleep to hard work with respiratory exchange ratios covering the range from hypoventilation. In addition, all of these parameters are remotely controllable to facilitate use of the device in hostile or remote environments. The exhaled breath is also maintained at body temperature and a high humidity. The simulation is accurate to the extent of having a variable functional residual capacity independent of other parameters.

Bartlett, R. G.↗

Improved pulmonary function in working divers breathing nitrox at shallow depths

INTRODUCTION: There is limited data about the long-term pulmonary effects of nitrox use in divers at shallow depths. This study examined changes in pulmonary function in a cohort of working divers breathing a 46% oxygen enriched mixture while diving at depths less than 12 m. METHODS: A total of 43 working divers from the Neutral Buoyancy Laboratory (NBL), NASA-Johnson Space Center completed a questionnaire providing information on diving history prior to NBL employment, diving history outside the NBL since employment, and smoking history. Cumulative dive hours were obtained from the NBL dive-time database. Medical records were reviewed to obtain the diver's height, weight, and pulmonary function measurements from initial pre-dive, first year and third year annual medical examinations. RESULTS: The initial forced vital capacity (FVC) and forced expiratory volume in 1 s (FEV1) were greater than predicted, 104% and 102%, respectively. After 3 yr of diving at the NBL, both the FVC and FEV1 showed a significant (p < 0.01) increase of 6.3% and 5.5%, respectively. There were no significant changes in peak expiratory flow (PEF), forced mid-expiratory flow rate (FEF(25-75%)), and forced expiratory flow rates at 25%, 50%, and 75% of FVC expired (FEF25%, FEF50%, FEF75%). Cumulative NBL dive hours was the only contributing variable found to be significantly associated with both FVC and FEV1 at 1 and 3 yr. CONCLUSIONS: NBL divers initially belong to a select group with larger than predicted lung volumes. Regular diving with nitrox at shallow depths over a 3-yr period did not impair pulmonary function. Improvements in FVC and FEV1 were primarily due to a training effect.

Non-programmatic↗

Mars in situ propellants: Carbon monoxide and oxygen ignition experiments

Carbon monoxide and oxygen were tested in a standard spark-torch igniter to identify the ignition characteristics of this potential Mars in situ propellant combination. The ignition profiles were determined as functions of mixture ratio, amount of hydrogen added to the carbon monoxide, and oxygen inlet temperature. The experiments indicated that the carbon monoxide and oxygen combination must have small amounts of hydrogen present to initiate reaction. Once the reaction was started, the combustion continued without the presence of hydrogen. A mixture ratio range was identified where ignition occurred, and this range varied with the oxygen inlet temperature.

Linne, Diane L.↗

Mars in situ propellants - Carbon monoxide and oxygen ignition experiments

Carbon monoxide and oxygen were tested in a standard spark-torch igniter to identify the ignition characteristics of this potential Mars in situ propellant combination. The ignition profiles were determined as functions of mixture ratio, amount of hydrogen added to the carbon monoxide, and oxygen inlet temperature. The experiments indicated that the carbon monoxide and oxygen combination must have small amounts of hydrogen present to initiate reaction. Once the reaction was started, the combustion continued without the presence of hydrogen. A mixture ratio range was identified where ignition occurred, and this range varied with the oxygen inlet temperature.

Linne, Diane L.↗

On the energy deposition of photoelectrons in the atmosphere of Venus

Vertical components of photoelectron fluxes in the atmosphere of Venus are computed by solving an appropriate form of the Boltzmann equation in the cases where there is no flux of either photoelectrons or solar-wind particles across the ionopause and where photoelectrons are free to escape from the atmosphere. It is assumed that Venus has no magnetic field and that the atmosphere is composed of carbon dioxide, atomic oxygen, and helium. The results are plotted as a function of altitude for several energies in the range from 100 eV to a cutoff of the order of 1 eV. Heating rates for the two upper boundary conditions and the case of no spatial transport are determined which show that transport effects dominate at altitudes greater than about 200 km. Electron temperatures are calculated for the adopted model atmosphere and ionosphere by solving the pertinent conservation equation, and excitation rates are computed for the CO Cameron band as well as the CO2(+) A and B bands.

Mccormick, P. T.↗

Spatial electron density and electric field strength measurements in microwave cavity experiments

Measurements of electron density and electric field strength have been made in an argon plasma contained in a resonant microwave cavity at 2.45 GHz. Spatial measurements of electron density, n sub e, are correlated with fluorescence observations of the discharge. Measurements of n sub e were made with Stark broadening and compared with n sub 3 calculated from measured plasma conductivity. Additional measurements of n sub 3 as a function of pressure and in mixtures of argon and oxygen are presented for pressures from 10 Torr to 1 atm. Measurements in flowing gases and in static systems are presented. In addition, limitations of these measurements are identified.

Peters, M.↗

The next generation microwave sounder for weather satellites

Microwave sounders are multichannel microwave radiometers for measuring atmospheric temperature (or humidity) profiles. These devices are also known as microwave spectrometers because a sounder typically has a number of channels measuring the spectral shape of an absorption line. Each channel of the sounder responds essentially to a given layer of the atmosphere. The characteristics of currently employed microwave sounders on satellites are briefly examined, and new features expected in connection with the introduction of the next generation sounders are discussed. There will probably be an increase in the number of oxygen channels with the objective to extend the weighting function height coverage into the stratosphere and to improve the temperature retrieval accuracy. Other features are to be related to better surface resolution, auxiliary channels, and water vapor sounding.

Shiue, J. C.↗

Spatial electron density and electric field strength measurements in microwave cavity experiments

Measurements of electron density and electric field strength have been made in an argon plasma contained in a resonant microwave cavity at 2.45 GHz. Spatial measurements of electron density, n sub e, are correlated with fluorescence observations of the discharge. Measurements of n sub e were made with Stark broadening and compared with n sub e calculated from measured plasma conductivity. Additional measurements of n sub e as a function of pressure and in mixtures of argon and oxygen are presented for pressures from 10 Torr to 1 atm. Measurements in flowing gases and in static systems are presented. In addition, limitations of these measurements are identified.

Peters, M.↗

NASA's approach to flight confidence

NASA's confidence in the flight readiness of aerospace hardware and software is achieved by a thorough integration of safety activities into every program facet, from concept through the mission. This involves technical and administrative personnel, organizations that specify requirements, design, manufacturing, test and the operators. Reviews by inhouse and external specialists form an integral part of the assurance process. Examples of safety issues and their resolution for some power and propulsion functions are given (lithium cells, autoignition/fretting in high pressure oxygen environments, ignition sources from auxiliary power unit, and low thrust rocket engines). Finally, some comments on NASA's integrated safety activities and the Aerospace Safety Advisory Panel's role in the NASA review and assessment process all of which provides added confidence in achieving a high level of mission safety and success.

Roth, G. L.↗

Oxygen interaction with space-power materials

Data from the space shuttle flights have established that many materials experience relatively rapid degradation when exposed to the low Earth orbit ambient atmosphere, which is predominately atomic oxygen. While much was learned from samples flown on the shuttle, laboratory simulations of the shuttle environment are necessary for a detailed understanding of the various interactions which contribute to the observed degradations. These laboratory experiments are particularly important for predicting the deterioration to be expected for materials aboard orbiting power systems, which will be exposed for long periods of time and could have components operating at very high temperatures. By using a mass spectrometer to synchronously detect molecules emitted from the surface as a result of amplitude modulated oxygen ion bombardment, quantum yields were obtained as a function of ion energy. A technique was developed to obtain preliminary yield data by slowly scanning the mass setting of the mass spectrometer; measurements were extended down to zero modulation frequency; yield data was obtained for the insulating materials (Nomex, Kevlar, and Teflon) used in the construction of electrodynamic tethers; a heated sample holder was constructed to investigate the effect of sample temperature on quantum yields; and the instrumentation was developed to observe the mass spectrometer signal as a function of time during and following bombardment of the sample by a brief (approximately 1 millisecond) pulse of ions.

Eck, T. G.↗

Detonability of hydrocarbon fuels in air

Studies were conducted of the detonation of gas-phase mixtures of n-hexane and JP-4, with oxidizers as varied as air and pure oxygen, measuring detonation velocities and cell sizes as a function of stoichiometry and diluent concentration. The induction length of a one-dimensional Zeldovich-von Neumann-Doering detonation was calculated on the basis of a theoretical model that employed the reaction kinetics of the hydrocarbon fuels used. Critical energy and critical tube diameter are compared for a relative measure of the heavy hydrocarbon fuels studied; detonation sensitivity appears to increase slightly with increasing carbon number.

Beeson, H. D.↗

Laser Rayleigh and Raman Diagnostics for Small Hydrogen/oxygen Rockets

Localized velocity, temperature, and species concentration measurements in rocket flow fields are needed to evaluate predictive computational fluid dynamics (CFD) codes and identify causes of poor rocket performance. Velocity, temperature, and total number density information have been successfully extracted from spectrally resolved Rayleigh scattering in the plume of small hydrogen/oxygen rockets. Light from a narrow band laser is scattered from the moving molecules with a Doppler shifted frequency. Two components of the velocity can be extracted by observing the scattered light from two directions. Thermal broadening of the scattered light provides a measure of the temperature, while the integrated scattering intensity is proportional to the number density. Spontaneous Raman scattering has been used to measure temperature and species concentration in similar plumes. Light from a dye laser is scattered by molecules in the rocket plume. Raman spectra scattered from major species are resolved by observing the inelastically scattered light with linear array mounted to a spectrometer. Temperature and oxygen concentrations have been extracted by fitting a model function to the measured Raman spectrum. Results of measurements on small rockets mounted inside a high altitude chamber using both diagnostic techniques are reported.

Degroot, Wilhelmus A.↗

Hydrogen partitioning and transport in titanium aluminides

This report gives the final summary of the research work perfomed from March 1, 1990 to August 28, 1993. Brief descriptions of the research findings are given on the surface variation of Ti-14Al-21Nb as a function of temperature under ultrahigh vacuum conditions; titanium aluminides: surface composition effects as a function of temperature; Auger electron intensity variation in oxygen-charged silver; and segregation of sulfur on a titanium surface studied by Auger electron spectroscopy. Each description details one or more of the attached corresponding figures. Published journal documents are provided as appendices to give further detail.

Han, Kwang S.↗