Search NASA⌕ Search

SEARCH · Search NASA

Results for “payback”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Preliminary Energy Costs and Savings Estimates: 2018 IECC Residential Requirements

This report provides preliminary estimates of the incremental costs and savings associated with the residential provisions of the 2018 International Energy Conservation Code (IECC). The analysis is provided to the U.S. Department of Energy (DOE) to help quantify the costs and savings impacts of the latest published edition of the IECC, the 2018 IECC. The incremental cost of building to the 2018 IECC, relative to the 2015 IECC, ranges from $\$398$ to $\$1,071$ depending on the climate zone, and payback periods range from 0 (immediate) to 1.8 years, depending on the climate zone.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Why Regional and Long-Haul Trucks are Primed for Electrification Now

Zero emission freight trucks are needed to both improve public health and reduce global greenhouse gas emissions but at the same time are generally believed to be uneconomical. However, recent dramatic declines in battery prices and improvement in their energy density have created opportunities for battery-electric trucking today that were seldom anticipated just a few years ago. At the current global average battery pack price of $135 per kilowatt-hour (kWh) (realizable when procured at scale), a Class 8 electric truck with 375-mile range and operated 300 miles per day when compared to a diesel truck offers about 13% lower total cost of ownership (TCO) per mile, about 3-year payback and net present savings of about US $200,000 over a 15-year lifetime. This is achieved with only a 3% reduction in payload capacity. Even this small penalty can be reversed cost-effectively through light-weighting, in any case, only matters for a small fraction of trucks which regularly utilize their maximum payload. Electric trucks appear poised to also meet the performance demands for a large share of regional and long-haul trucking today. The estimated average distance traveled between 30- minute driver breaks is 150 miles and 190 miles for regional-haul and long-haul trucks respectively in the US. Thirty minutes of charging using 500 kW or mega-Watt scale fastchargers would add sufficient range without impairing operations and economics of freight movement. However, as with almost any clean technology, higher upfront capital costs of both vehicles and charging infrastructure are major barriers when electric trucking is in its infancy. Without strong policy support, coordinated investments in both vehicle manufacturing and fuel infrastructure will not be forthcoming on the scale needed to harness the true potential of battery electric trucks.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Colorado Residential Retrofit Energy District (CoRRED) Phase I: Final Modeling Results

Electrification of buildings and transportation coupled with increased deployment of distributed energy resources (DERs) has been identified as a key step toward meeting emissions reduction goals across the U.S. Examples of pilot projects that feature innovative, 'smart' electric neighborhoods are largely focused on new construction projects, but there is a need to address the millions of existing homes so that they too may accommodate cleaner yet variable energy production in ways that benefit both the utility grid and the homes' residents. The Colorado Residential Retrofit Energy District (CoRRED) project used building and grid co-simulation tools to model an advanced energy district demonstration in an existing residential neighborhood in Denver, Colorado, and explored how existing building and utility infrastructures can be enhanced with combinations of traditional energy-efficiency retrofit measures and integration of solar panels and other DER technologies to provide better affordability and reliability. We analyzed which packages of DERs most reliably enable demand flexibility in response to a time-of-use (TOU) rate. Our results clearly indicate that incorporating DERs into efficient electrification produces much bigger utility bill savings on an annual basis than efficient electrification without DERs. While electrifying a neighborhood will increase the maximum load, batteries and solar panels can reduce load during peak hours so that the community can be a net producer during peak periods. A remaining challenge is to overcome first cost barriers to implementing energy-efficiency and DER technologies, as modest utility bill savings require long payback periods that are not practical for most homeowners.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Preliminary Pilot-scale Study and Techno-economic Analysis of Chemical Heat Pump with Conventional Nuclear Reactors

The energy economy is continually evolving, particularly in terms of primary energy sources, their conversions to useful forms such as electricity and heat, and their utilization in different sectors, in response to socio-political factors. Because nuclear source is clean and non-carbon-emitting energy source, it is crucial to consider its role in the evolution of the energy economy. A pilot-scale study was conducted for Chemical Heat Pump (ChHP) system at three different scales (25-, 100-, and 1000-kW thermal outputs) using steady state thermal model. To establish the viability of selling heat rather than electricity alone, techno-economic analysis was undertaken for advanced Small Modular Reactor (SMR), and SMR paired with varied thermal output ChHP systems was referred to as the nuclear hybrid energy system (NHES) in this study. Using the U.S. Energy Information Administration statistics, pricing for electricity and natural gas were anticipated for U.S. regions (California, Northwest, Midwest, Southwest, New England, and PJM). Based on thermal output from ChHP, advanced SMR with 100 MWth and four alternative NHES scenarios were explored, namely 50-, 10-, 5-, and 1-MWth. Net present value, payback period, discounted cash flow return, and levelized cost of energy were evaluated for all scenarios. Based on the economic analysis, selling heat to high-temperature industrial processes is more profitable compared to selling electricity only. Higher carbon taxes showed significant improvement in economic parameters for NHESs. Providing heat to high-temperature industries could be beneficial, helping to reduce the greenhouse gas emissions by slashing the fossil fuel consumption.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improving the Economic Viability of Biological Utilization of Coal Power Plant CO 2 by Improved Algae Productivity and Integration with Wastewater Treatment

The overall goal of this project was to improve the cost-effectiveness of systems using algae to capture and beneficially utilize CO 2 from the flue gas of coal-fired power plants. Algal biomass cultivation is an attractive alternative for carbon capture and utilization because it can uptake more CO 2 per land area than any other photosynthetic crop. Also, the resulting biomass can be used to make valuable large-market commodity products, such as biofuels and animal feed. However, the use of algal carbon capture has been limited by several factors including: (1) high costs for growing algae (>$\$1,300$/ton), (2) large land requirements for algae cultivation, and (3) environmental concerns about the large amount of water and nutrient inputs needed for growing algae. This project has taken direct aim at resolving these key limitations and demonstrated several viable approaches to improve the economic and environmental feasibility of algal carbon capture. In particular, this project demonstrated a significant increase in average annual algal productivity from baseline values of 8 g/m 2 -day to above 20 g/m 2 -day. This supports a much lower projected cost of algae production (<$\$500$/ton) and reduces land requirements by more than 50%. Additionally, this project confirmed the ability to grow multiple algae species with wastewater nutrients, which facilitates the potential for substantial new revenue streams for algae cultivation based on tipping fees for nutrient laden wastewater. This study highlighted that there is more potential value in wastewater nutrient treatment credits than in the primary commodity products made from algae. The use of wastewater inputs also mitigates the concerns associated with the large amount of water needed for growing algae. The algal biomass grown for this project using wastewater and simulated flue gas inputs were characterized for potential use as an animal feed ingredient. The algae had a protein content in the range of 35-40%, which is between some common commodity animal feed products— distiller’s grains (~25-30% protein) and soybean meal (45-50% protein). In-vitro digestion tests using cattle rumen fluids, showed that this algae biomass was best suited for use as “bypass protein”, which is digested in the animal intestine. Based on the protein content and amino acid profile of the algae grown in this study, it was estimated to have market value in the range of $\$190$-$\$280$/ton. There is potential for higher value feed products if the algae content of omega-3 fatty acids or antioxidants is accounted for. This project also did small scale demonstration of forward osmosis algae dewatering and nanofiltration of hydrothermal liquefaction aqueous products, which were shown to improve the cost and energy balance for producing algal products. When all the improvements demonstrated in this study were included in techno-economic analysis, it showed there was a viable pathway to profitable algal CO 2 utilization with a payback period in the range of six to ten years.

01 COAL, LIGNITE, AND PEAT↗

Case Study: NREL Campus Chilled Water Storage Potential: Benchmark Datasets Development and Applications, Task 4 - Use Case Demonstration

The Benchmark Datasets Development and Applications project is a three-year collaboration between the National Renewable Energy Laboratory (NREL), Oak Ridge National Laboratory, Pacific Northwest National Laboratory, and Lawrence Berkeley National Laboratory. The project seeks to collect and curate high-resolution, well-calibrated time series of building operational and indoor/outdoor environmental data, which are crucial to understanding and optimizing building energy efficiency performance and demand flexibility capabilities as well as benchmarking energy algorithms. Project outcomes include approximately twelve high-fidelity building datasets, enhanced data representation tools, and four case studies to illustrate example applications. The goal of these case studies is to define and execute analyses that demonstrate how one or more datasets collected through this project can address a data gap or challenge historically faced by building stakeholders. This technical paper summarizes the findings of one of these case studies, in which we studied the operational efficiencies of the central cooling system at NREL. We looked at three years of data from the three chillers in the Field Test Laboratory Building (FTLB), from 2019 to 2021, to compare equipment operation and demand throughout the time period. Our analysis indicates that all three chillers are operating at or below the optimal loading conditions for most of the operation time, and thus there was no efficiency drop due to loading of the chillers at full capacity. Our recommendation is that no chiller capacity increase is needed; instead, the central plant could benefit from adopting advanced control logics for optimal sequencing of chillers during part load operations. Analysis of adding chilled water thermal storage to the central plant indicated 34% savings in demand cost and 24.5% savings in total cost (energy consumption and demand charge cost). The payback period is estimated to be 11-22 years with an assumed TES cost of $\$$100-$200 per ton. This case study shows how a selected dataset is used to solve a practical building problem - learning the operational status of its components, analyzing the effectiveness of a proposed new technique, and aiding decision-making for the building operations and maintenance team.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Demonstration of a Fuel-Efficient, Class 8 Tractor & Trailer Engine System (SuperTruck II)

Navistar presents the SuperTruck II (ST II) Final Report to the Unites States Department of Energy (US DOE), which covers the five Budget Periods (BPs) from 10-1-2016 through 6-30-2022. For ST II, Navistar built on the achievements of the SuperTruck I (ST I) Program as a catalyst to continue critical research, design and development, testing, and operations to reach the ambitious goals of the ST II project. This approach allowed Navistar to continue contributing to the essential needs of our nation for safe, efficient, and cost-effective delivery of goods and services, as we reduced negative environmental effects and improved operational productivity. This document contains information specified in DOE F 4600.2, Final Scientific/Technical Report DOE F 241.3, B. SCIENTIFIC/TECHNICAL REPORTS, explaining how we met and exceeded program requirements. Throughout this Final Report, Navistar extracted information from documents prepared during the project that represent our management, design and development, building, and testing efforts to meet and exceed SuperTruck II project goals. Navistar followed Plan requirements to achieve / exceed Project Objectives: a) >100% improvement in vehicle freight efficiency (FE) (on ton-MPG basis) relative to 2009 baseline with stretch goal of 140% improvement [actual: 170%); b) >55% engine brake thermal efficiency (BTE) demonstrated in operational engine at a 65-mph cruise point on a dynamometer – ≥31% increase from 2009 baseline [actual: 55.20% of combined BTE) ; and c) development and implementation of commercially cost effective technologies (in terms of a simple payback). Technology selection / development path focused on developing technologies applicable for production within 3-year approach, while ensuring technology readiness and cost of ownership for end users. The Program was organized into five budget periods: Requirements / Technology Assessment and Initial Hardware Testing; Technology Development and Concept Readiness Demonstration; Technology Finalization and Validation Tractor / Trailer Fabrication, Integration and Commissioning Demonstration; and Fuel Economy (FE) and Brake Thermal Efficiency (BTE) and Program Completion. Leadership was provided by DOE, with tasks performed by laboratories (Argonne National Laboratory, Lawrence Livermore National Laboratory); partners at Bosch, TPI, Dana, and J.B. Hunt; , and support from University of Michigan and Clemson University. Navistar lead this team with Principal Investigator / Contracting Officer; Project Manager (PM); Vehicle, Engine, and Aftertreatment Engineers; Finance Manager, Technical Program Leads, and Legal/IP; and other key personnel. Work also included personnel in risk management; funding / budget / finance. Work involved analysis, development, testing, and down selection of individual/system engine, aftertreatment, and vehicle technologies, with integration of selected technologies into a prototype vehicle for demonstration of fuel-efficiency gain. Work also included component/integrated system level development of truck and trailer aerodynamics, base engine efficiency, advanced aftertreatment, combustion efficiency, waste heat recovery, hybrid powertrain, reduced rolling resistance, weight reduction, idle reduction, and driver feedback. As ST II progressed, Navistar performed computer-based modeling / simulations of technologies focused on the primary operational areas: Engine, Aftertreatment, and Vehicle. During the ST II Program, the COVID Virus outbreak unexpectedly challenged by the effects of, which affected staffing, scheduling, design, supplies, availability of materials, production procedures, and testing. The DOE responded by extending the program by three quarters to ensure that project tasks were completed for this vital project. Focus continued on analyzing, developing, testing, and down selecting individual-/system-level engine and vehicle technologies for integration of the final selected technologies into a prototype vehicle that would demonstrate fuel-efficiency gains made possible through these technologies. This included component/integrated system-level development of truck and trailer aerodynamics, base engine efficiency, advanced aftertreatment, combustion efficiency, waste heat recovery, solar power, distributed and intelligent vehicle power, hybrid powertrain, reduced rolling resistance, weight reduction, idle reduction, and driver feedback. Throughout the program, function, reliability, and performance at all levels were ensured through testing. Proof of this approach was demonstrated in multiple, on-road demonstrations: Scenario A (Flatland) Fuel Economy, Scenario B (Hilly) Fuel Economy, and City Cycle Tests. Other benefits derived from ST II included new/improved products, publications, patents, and next-step capabilities related to electric/hydrogen vehicles and autonomous driving.

Zukouski, Russ↗

Hybrid Heavy Duty Diesel Powertrain for Off-Road Applications (Final Technical/Scientific Report)

In this program, a heavy-duty hybrid powersystem, consisting of a 30% downsized diesel engine and a front-end accessory drive (FEAD) incorporating a high-speed flywheel (HSFW) energy storage system, a mechanical-drive turbocharger (SuperTurbo), and motor-generator units (MGU) was developed and demonstrated. The high efficiency core 13L engine coupled with the hybrid elements was physically validated across various off-road machine and transient work cycles with the ultimate goal of demonstrating 17% efficiency improvement with equivalent transient response as the 18L diesel engine this concept powersystem would replace. The project culminated in a physical demonstration of the high-efficiency powersystem in a high-capability test cell with the engine, all the hybrid devices, controls, and required performance and emissions measurements. Based on the combination of physical validation and rigorous system simulation, the following program conclusions may be drawn: (1) The developed hybrid H2D2 powersystem demonstrated a range of efficiency improvement of 10.5 - 25.6%, with a midpoint of 17.9%; (2) Transient load response on; (3) The HSFW system was validated to achieve peak assisting of 110kW at 12,000 Nm/sec ramp rates; (4) The powersystem was validated to be capable of meeting U.S. EPA Tier 4 Final off-road emissions through transient NRTC testing; (5) A Total Cost of Ownership (TCO) analysis and found that the core 13L engine would pay back immediately (adoption of start/stop would pay back in less than one year, and the full hybrid system payback was three years.)

33 ADVANCED PROPULSION SYSTEMS↗

Scalable, Dual-Mode Occupancy Sensing for Commercial Venues

The ability to establish accurate occupancy is a key enabler for improved energy efficiency in human-occupied indoor spaces. The accurate counts can be used to adjust, in real-time, air exchange, heating, and cooling, to closely match the environmental needs of the occupants rather than to use a single setting based on maximum room occupancy. This project focuses on the use of overhead fisheye cameras and artificial intelligence (AI) algorithms as the technology to realize accurate people counting in large commercial spaces. We developed Computational Occupancy Sensing SYstem ("COSSY''), which supports large-scale deployment (thousands of square feet) and straightforward installation (using conventional power over ethernet), while providing high accuracy and low cost. COSSY has been validated at Boston University and by a third party, demonstrating people-counting accuracy of at least 89.5% in large spaces (2,000 sqft). A cost/benefit analysis performed for Boston commercial market indicates that a full payback of COSSY deployment costs due to energy savings would occur within 3-6 months from installation. Applications of COSSY reach far beyond saving energy. The precise people counting in real time could also be useful for emergency response (e.g., fire), in spatial analytics (e.g., office space management) and in some health applications (e.g., social distance assessment during pandemics).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Volvo Pathway to Cost-Effective Commercialized Freight Efficiency (SuperTruck 2)

Volvo’s SuperTruck 2 (ST2) built on the success of the SuperTruck 1 (ST1) project, with the objective to research, develop, and demonstrate a Class 8 long-haul tractor-trailer concept truck designed with an integrated approach to maximize freight efficiency and achieve the following goals: - Greater than 100% improvement in vehicle freight efficiency (FE) on a ton-mile-per-gallon basis, with a stretch goal of 120% improvement relative to a 2009 baseline. - Greater than or equal to 55% engine brake thermal efficiency (BTE) demonstrated in an operational engine at a 65-mph cruise point on a dynamometer. - Develop technologies that are commercially cost effective in terms of a simple payback. This cooperative agreement with the US Department of Energy (DOE) had a total project cost of $40,000,000 with a 50% cost share, or $20,000,000, paid by the DOE. This project was awarded to Volvo Technology of America, LLC, who was the prime recipient and project lead. Metalsa, Michelin, Wabash, Bergstrom, University of Michigan, Oak Ridge National Laboratory, Johnson Matthey, Knight Transportation, Wegmans, and Motivo were partners / sub-recipients in this project.

33 ADVANCED PROPULSION SYSTEMS↗

LA100 Equity Strategies. Chapter 6: Universal Access to Safe and Comfortable Home Temperatures

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. This chapter focuses on housing weatherization and cooling technologies as means to increase access to safe and comfortable home temperatures. Lack of cooling access and use can have severe health impacts on building occupants during heat waves. Specifically, NREL developed and used a residential building stock model to simulate the energy use of 50,000 dwellings representing the diversity of housing types, appliances, climate zones, and household incomes across Los Angeles. We compared a baseline scenario with seven upgrade scenarios. Five scenarios cooled the entire household and featured cooling systems at varying efficiency levels with various improvements to the envelope, roof, and shading, and two scenarios cooled a single room in a household with no prior cooling using either a room air-conditioning or a heat pump system. For each scenario, we evaluated impacts on utility bills, payback periods, and changes in energy burdens, as well as ability to achieve safe and comfortable temperatures. We also examined the effects of building types (multifamily vs. single-family) on indoor air temperatures. Based on the results of modeling, analysis, and community guidance, we identified six short-term and two long-term strategies for improving access to building envelope upgrades and cooling strategies that could save lives and maintain safe home temperatures for Los Angeles' low-income households during heat waves. Research was guided by input from the community engagement process, and associated equity strategies are presented in alignment with that guidance.

air conditioning↗

New Two-Cylinder Prototype Demonstration and Concept Design of a Next Generation Class 3-6 Opposed Piston Engine (Final Report)

The objective of the project is to research, develop, and test an Opposed Piston (OP) engine prototype capable of ≥10% fuel economy improvement over a 2015 baseline diesel engine while meeting prevailing emissions standards and include a cost analysis of the proposed technologies that validates an operating cost payback of less than 2 years. Results: In direct comparison with the baseline Isuzu model, the OP engine exhibited a noteworthy average fuel economy improvement exceeding 12% across five distinct driving cycles, including the Interstate cycle, Congested interstate cycle, GM-city cycle, HWFET cycle, and FTP cycle, with Interstate cycle benefited the most.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Photovoltaic and Behind-the-Meter Battery Storage: Advanced Smart Inverter Controls and Field Demonstration

Electric utilities have little visibility of the electrical distribution system, and consequently, limited diagnostic capabilities. The distribution grid was designed for a unidirectional power flow, where energy is supplied by few large centralized power plants; however, this is set to change to meet California’s aggressive decarbonization goals. The large-scale deployment of distributed renewable generation, such as photovoltaics (PV), can have many negative effects on an unprepared grid. As illustrated in the California “duck curve,” PV generation modifies load profiles during the day, which causes steep ramping in the evening. This effect indicates the need to revise the electrical grid’s design and operation. This project sought to (a) create a centralized resource in California to test and validate distribution technology controls with industry standard PV, storage, and high-fidelity sensors, (b) support strategic and operational decisions for new grid architectures by providing simulation models, (c) promote new ways to control clusters of PV smart inverters, in accordance with California Rule 21, and (d) innovate, develop, and field test a predictive controller to maximize economic profit for the customer while supporting the grid. The controller was built using the state-of-the-art model predictive control methodology to optimally control behind-the-meter PV and battery storage. In consideration of the duck curve, the controller optimally controls the battery dispatch by charging during excess generation periods and discharging during the critical afternoon demand hours. The controller was evaluated in annual simulations and revealed the potential cost-effectiveness of behind-the-meter battery storage. The simulations showed that the annual electricity bill could be reduced by as much as 35 percent, with a payback period of the investment in battery storage in about 6 years – significantly shorter than the manufacturer’s 10-year warranty. All developed simulation models, the grid event library, and the MPC controller are open-source and available online.

Model Predictive control↗

03.02.02.45: Energy Efficiency Improvement Approaches in Ice Related Processes

The primary objective of this project was to facilitate the dislocation of the interfacial ice layer by employing advanced materials and ultrasonic vibration to reduce ice adhesion strength. This work employed two technical approaches that were thoroughly investigated and previously reported. The effectiveness of these approaches, both individually and in combination, has been quantified, demonstrating notable energy savings. The projected payback period for these enhancements is approximately 2.2 years or less, contingent upon specific energy costs. Furthermore, these advancements hold significant promise for reducing carbon emissions across various equipment scales. This study particularly focused on the ultrasonic deicing technique for diverse structures, utilizing numerical simulations to evaluate performance and potential benefits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pueblo of Laguna Village Community Solar

The project was to install approximately 11.44 kilowatts (kW) rooftop solar photovoltaic (PV) system on the Mesita Village Community Center, an approximately 9.24 kW rooftop solar PV system on the Paguate Village Community Center, an approximately 21.56 kW rooftop solar PV system on the Paraje Village Community Center, and an approximately 11.00 kW rooftop solar PV system on the Seama Community Center, for a total of about 53.24 kW on four village community centers. The systems were expected to generate approximately 93,329 kWh annually. Installing solar PV systems on the four village community centers would have helped achieve the Pueblo of Laguna’s six energy objectives: community development (decreased utility bills, funds for other needs), economic development (training and participation in the renewable energy economy), energy reliability (future storage), community resilience (alternative sources), relationship to people and the natural world (reducing fossil fuel use), and energy sovereignty (Pueblo decision-making). Installing solar PV systems would have also met specific project goals to offset not less than 85% of each selected building’s annual electricity use, ranging from 87% to 103% of demand; save a minimum of 70% of the cost of utility bills per year for each building, ranging from 75% to 77% percent (including service charges); and would have had payback periods shorter than the estimated useful life of the project

14 SOLAR ENERGY↗

Optimizing Hydronic Heating for Comfort and Performance in Multifamily Housing

Inefficient control settings in multifamily boilers often lead to substantial energy and cost penalties. To address this, a Fault Detection and Diagnostic (FDD) tool was developed to automate data analysis and identify operational faults such as suboptimal outdoor temperature sensor placement, misconfigured outdoor air reset (OAR) curves, excess boiler cycling, and domestic hot water (DHW) setpoint errors. By comparing pre- and post-implementation periods and applying engineering models, the tool quantifies energy savings and reduces manual analysis time by over 90%. Testing on over 100 monitored sites and a targeted subset of 12 buildings showed an average 11% energy savings from remote optimization; further validation across 19 OAR curve changes confirmed the tool’s accuracy, predicting actual savings within ±5% for most cases. Simple payback can be under three years for many multifamily buildings, though rising hardware, labor, and fuel costs create uncertainties, and decarbonization goals increasingly shift focus to electrification. The FDD tool remains invaluable for optimizing existing boilers, enhancing future electrification measures, and adapting to new technologies by refining building load estimates. In doing so, it supports both near-term efficiency and long-term transitions to low-carbon alternatives, ensuring buildings achieve substantial cost and energy benefits throughout their system lifecycles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Powernet in Farms Project

Coordinating behind-the-meter (BTM) distributed energy resources (DERs) is critical to ensuring efficiency and reliability for consumers facing an increasingly variable grid supply. Outside of very controlled environments, however, such coordination of heterogeneous resources at scale has remained a challenge due to harsh field conditions, the lack of adequate communication infrastructure, and the difficulty of modeling the system. The intent of this research was to refine the Powernet system deployed in a California dairy farm to achieve the following objectives: a) validate the results of the previous deployment and b) validate new hypothesis about system performance based on the simulation of the new system. The new system design would reduce the overall system cost, and achieve a payback period of less than 3 years, demonstrating the feasibility of such system and its relevance for a segment not well known for technology advancements in power systems. The new proposed system was significantly cheaper than the original design, which would enable the solution to be cost effective and likely economically viable. However, due to significant delays in project start date which affected funding availability, overlap with prior scheduled mandatory military leave from key members of the project team, and customer drop-out, due to the significant delays, which could not be replaced in time, caused the project to be ended prior to completion.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermoelectric heat pump water heater priced for mass market deployment with 30% energy savings

This project, a Cooperative Research and Development Agreement (CRADA) partnership between A. O. Smith and Oak Ridge National Laboratory (ORNL), was initiated to develop a heat pump water heater (HPWH) based on thermoelectric (TE) heat pump technology capable of seeing widespread market adoption by having a one-year payback versus electric resistance options.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗