Search NASA⌕ Search

SEARCH · Search NASA

Results for “photon counting detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

The High Resolution Imaging Instrument for HEAO-B

The High Resolution Imaging Instrument for the HEAO-B X-ray Telescope satellite is designed to reproduce images of celestial X-ray sources in the range of 0.2 to 4.0 keV. It provides both imaging and temporal data. The basic detector is a two-stage microchannel plate with a crossed-grid charge detector. Preamplifiers, detector bias supplies, and some processing circuits are colocated with the detector. The remaining electronic circuits are located in a remote central electronic assembly. The processing system is designed for single-photon processing. The imaging data rate is limited to 100 data points per second. Non-imaging total-field count rate is acquired with a maximum dead time of 14 microseconds per event.

Kubierschky, K.↗

High-Rydberg Xenon Submillimeter-Wave Detector

Proposed detector for infrared and submillimeter-wavelength radiation uses excited xenon atoms as Rydberg sensors instead of customary beams of sodium, potassium, or cesium. Chemically inert xenon easily stored in pressurized containers, whereas beams of dangerously reactive alkali metals must be generated in cumbersome, unreliable ovens. Xenon-based detector potential for infrared astronomy and for Earth-orbiter detection of terrestrial radiation sources. Xenon atoms excited to high energy states in two stages. Doubly excited atoms sensitive to photons in submillimeter wavelength range, further excited by these photons, then ionized and counted.

Chutjian, Ara↗

A rare gas optics-free absolute photon flux and energy analyzer to provide absolute photoionization rates of inflowing interstellar neutrals

A prototype spectrometer has been developed for space applications requiring long term absolute EUV photon flux measurements. The energy spectrum of the incoming photons is transformed directly into an electron energy spectrum by taking advantage of the photoelectric effect in one of several rare gases at low pressures. Using an electron energy spectrometer, followed by an electron multiplier detector, pulses due to individual electrons are counted. The overall efficiency of this process can be made essentially independent of gain drifts in the signal path, and the secular degradation of optical components which is often a problem in other techniques is avoided. A very important feature of this approach is its freedom from the problem of overlapping spectral orders that plagues grating EUV spectrometers. An instrument with these features has not been flown before, but is essential to further advances in our understanding of solar EUV flux dynamics, and the coupled dynamics of terrestrial and planetary atmospheres. The detailed characteristics of this optics-free spectrometer are presented in the publications section.

Judge, Darrell L.↗

A rare gas optics-free absolute photon flux and energy analyzer for solar and planetary observations

We have developed a prototype spectrometer for space applications requiring long term absolute EUV photon flux measurements. In this recently developed spectrometer, the energy spectrum of the incoming photons is transformed directly into an electron energy spectrum by taking advantage of the photoelectric effect in one of several rare gases at low pressures. Using an electron energy spectrometer, followed by an electron multiplier detector, pulses due to individual electrons are counted. The overall efficiency of this process can be made essentially independent of gain drifts in the signal path, and the secular degradation of optical components which is often a problem in other techniques is avoided. A very important feature of this approach is its freedom from the problem of overlapping spectral orders that plagues grating EUV spectrometers. An instrument with these features has not been flown before, but is essential to further advances in our understanding of solar EUV flux dynamics, and the coupled dynamics of terrestrial and planetary atmospheres. The detailed characteristics of this optics-free spectrometer are presented in the publications section.

Judge, Darrell L.↗

Search for gamma ray bursts with coincident balloon flights

A search was conducted for cosmic gamma ray bursts of small size and of sufficient frequency of occurrence to be detected during a one day observation program. Two similar detectors, successfully balloon-borne from launch sites in South Dakota and Texas, achieved about 20 hours of simultaneous operation at several millibars atmospheric depth, with continuous separation of over 1,500 km. Fluctuations of the counting rates of less than 150 keV photons with temporal structures from microseconds to several minutes were compared in order to detect coincident or associated responses from the two instruments. No coincident gamma-ray burst events were detected. The resulting integral size spectrum of small bursts, from this and from all other searches, remains a spectrum of upper limits, consistent with an extrapolation of the size spectrum of the largest known bursts, fitting a power low of index -1.5.

Cline, T. L.↗

A study of the temporal and spectral characteristics of gamma ray bursts

Gamma-ray burst data obtained from the ISEE-3 Gamma Ray Burst Spectrometer and the Solar Maximum Mission's Hard X-ray Burst Spectrometer (HXRBS) were analyzed to yield information on burst temporal and spectral characteristics. A Monte Carlo approach was used to simulate the HXRBS response to candidate spectral models. At energies above about 100 keV, the spectra are well fit by exponential forms. At lower energies, 30 keV to 60 keV, depressions below the model continua are apparent in some bursts. The depressions are not instrumental or data-reduction artifacts. The event selection criterion of the ISEE-3 experiment is based on the time to accumulate a present number of photons rather than the photon count per unit time and is consequently independent of event duration for a given burst intensity, unlike most conventional systems. As a result, a significantly greater percentage of fast, narrow events have been detected. The ratio of count rates from two ISEE-3 detectors indicates that bursts with durations or approx. one second have much softer spectra than longer bursts.

Norris, J.↗

Optimum testing of multiple hypotheses in quantum detection theory

The problem of specifying the optimum quantum detector in multiple hypotheses testing is considered for application to optical communications. The quantum digital detection problem is formulated as a linear programming problem on an infinite-dimensional space. A necessary and sufficient condition is derived by the application of a general duality theorem specifying the optimum detector in terms of a set of linear operator equations and inequalities. Existence of the optimum quantum detector is also established. The optimality of commuting detection operators is discussed in some examples. The structure and performance of the optimal receiver are derived for the quantum detection of narrow-band coherent orthogonal and simplex signals. It is shown that modal photon counting is asymptotically optimum in the limit of a large signaling alphabet and that the capacity goes to infinity in the absence of a bandwidth limitation.

Yuen, H. P.↗

HEAO 1 observations of high-energy X-rays from 3C273

The first detection of high energy (13 to 120 keV) X rays from the quasar 3C273, made by the HEAO 1 satellite, is reported. Observations were made with the 13 to 180 keV slat collimated detectors of the high energy X-ray and low energy gamma-ray (A4) experiment during December 1977-January 1978 and June-July 1978. Results are consistent with the previously observed X-ray flux variability on a scale of months. Photon count rates are presented for each of five energy bands and count rate and photon spectra for the June through July 1978 observations are derived. A comparison of the data obtained with that at lower X-ray energies and higher gamma-ray energies indicates that there is an overall spectral steepening from low to high energies and a possible break near 20 keV, which may be due to the gamma rays originating from a different region than that of the X rays.

Primini, F. A.↗

Soft X-ray photoemission with the SSX-100 spectrometer

Photoemission and SEXAFS experiments were conducted using a double crystal monochromator at the Stanford Synchrotron Radiation Laboratory. Photoelectrons were detected using a Surface Science Laboratories SSX-100 electron analyzer, which employs a magnetic/electrostatic lens, hemispherical geometry, and a two-dimensional position-sensitive detector. In the kinetic energy range of interest (1000-2000 eV), a significant improvement in count rate was observed over a single channel cylindrical mirror analyzer system. Ten second scans of the KLL silicon Auger peak manifold were recorded at a large number of photon energies for subsequent determination of SEXAFS spectra.

Hecht, M. H.↗

High-resolution pulse-counting array detectors for imaging and spectroscopy at ultraviolet wavelengths

The performance characteristics of multianode microchannel array (MAMA) detector systems which have formats as large as 256 x 1024 pixels and which have application to imaging and spectroscopy at UV wavelengths are evaluated. Sealed and open-structure MAMA detector tubes with opaque CsI photocathodes can determine the arrival time of the detected photon to an accuracy of 100 ns or better. Very large format MAMA detectors with CsI and Cs2Te photocathodes and active areas of 52 x 52 mm (2048 x 2048 pixels) will be used as the UV solar blind detectors for the NASA STIS.

Timothy, J. Gethyn↗

Qualification of A Transition Edge Sensor Based Anti-Coincidence Detector for A Probe Class Mission

The Line Emission Mapper (or LEM) is an X-ray probe class mission aimed to study the physics of galaxy formation, with a large field-of-view, high-resolution transition-edge sensor (TES) microcalorimeter. Because of the diffuse and faint nature of LEM’s targets, a high-fidelity anticoincidence detector (anti-co) is essential to reduce instrument background below the level of sky background. Lying directly behind the LEM sensor, the anti-co will detect ~3 counts per second per square centimeter from background galactic cosmic rays and the secondary particles they induce to detect and flag any events that could be confused with a science photon in the 0.3-2 keV signal band of LEM. Our design spans an active region 4-cm in diameter. It consists of 12 quasiparticle-trap-assisted electrothermal-feedback (QET) channels, each with 100 parallel TESes with common bias lines. The TES is a narrow strip of Mo/Au bilayer. We present fabrication processes that maintain the transition temperature (T c ) in Mo/Au bilayer structures across the active region. We further present a new design based on a a-Si/W TES layer that has previously achieved reasonable uniformity in lab testing.

x-ray↗

A rare gas optics-free absolute EUV photon spectrometer for solar system studies

We have developed a prototype spectrometer for space applications which require long term absolute EUV photon flux measurements. In this recently developed spectrometer, the energy spectrum of the incoming photons is transformed directly into an electron energy spectrum by taking advantage of the photoelectric effect in one of several rare gases at low pressures. Using an electron energy spectrometer operating at a few eV, and followed by an electron multiplying detector, pulses due to individual electrons are counted. The overall efficiency of this process is essentially independent of gain drifts in the signal path, and the secular degradation of optical components which is often a problem in other techniques is avoided.

Daybell, M. D.↗

Fundamentals of Free-Space Optical Communications

Free-space optical communication systems potentially gain many dBs over RF systems. There is no upper limit on the theoretically achievable photon efficiency when the system is quantum-noise-limited: a) Intensity modulations plus photon counting can achieve arbitrarily high photon efficiency, but with sub-optimal spectral efficiency. b) Quantum-ideal number states can achieve the ultimate capacity in the limit of perfect transmissivity. Appropriate error correction codes are needed to communicate reliably near the capacity limits. Poisson-modeled noises, detector losses, and atmospheric effects must all be accounted for: a) Theoretical models are used to analyze performance degradations. b) Mitigation strategies derived from this analysis are applied to minimize these degradations.

deep space communications↗

The Ever Changing X-ray Sky: X-ray Transients Observed With BATSE

X-ray transients are typically sources in our own galaxy. They are called "transient" because they usually spend more time in quiescence than in outburst. These transients consist of a compact object and a "normal" star in a binary system. The compact objects in some of these systems are known to be neutron stars because they exhibit X-ray bursts or periodic pulsations, Other systems are believed to contain black holes based upon their outburst behavior and in some cases, optical measurements of their masses. The Burst and Transient Source Experiment (BATSE), one of 4 instruments on the Compton Gamma Ray Observatory, was an all-sky instrument sensitive to photons from about 20 keV to 2 MeV, designed primarily to detect gamma-ray bursts. Transient and persistent hard X-ray point sources were extracted from the data using the Earth occultation method to measure source intensities. In this method, the change in count rate in a BATSE detector was measured just before and just after a source location was occulted by the Earth. For long period pulsars (>1 second) Fourier transforms and epoch-folded searches were used to measure pulse frequency and pulsed flux. Using these methods, 3 black hole candidates and 6 X-ray pulsars were discovered with BATSE during its 9 years in orbit. BATSE provided unprecedented temporal coverage in the 20 keV - 2 MeV band, allowing detection of numerous new outbursts of X-ray transients. In this talk, I will describe the BATSE instrument, discuss methods we use to detect hard X-ray sources, and describe observations of X-ray transients.

Wilson-Hodge, Colleen A.↗

Eye-safe visible wavelength lidar

Recent technological advances on several fronts offer the possibility for relatively low-cost, eye-safe visible-wavelength lidar systems for autonomous aerosol/environmental monitoring applications. Improved silicon photodiodes and avalanche photodiodes that have become available offer high-quantum-efficiency detection at very low dark counts (10 to 1000 count/s) and can be used in a photon counting mode for signal plus background and dark current photoelectron count rates of megahertz. The essential requirements and features of a possible lidar system that capitalizes on technical advances on several fronts are outlined. A baseline lidar system is suggested for monitoring tropospheric and stratospheric aerosols. Sensitivity to wavelength, background radiation, detector characteristics, and other system parameters is discussed for several simulated data sets.

Cooley, T. W.↗

Multiple-Event, Single-Photon Counting Imaging Sensor

The single-photon counting imaging sensor is typically an array of silicon Geiger-mode avalanche photodiodes that are monolithically integrated with CMOS (complementary metal oxide semiconductor) readout, signal processing, and addressing circuits located in each pixel and the peripheral area of the chip. The major problem is its single-event method for photon count number registration. A single-event single-photon counting imaging array only allows registration of up to one photon count in each of its pixels during a frame time, i.e., the interval between two successive pixel reset operations. Since the frame time can t be too short, this will lead to very low dynamic range and make the sensor merely useful for very low flux environments. The second problem of the prior technique is a limited fill factor resulting from consumption of chip area by the monolithically integrated CMOS readout in pixels. The resulting low photon collection efficiency will substantially ruin any benefit gained from the very sensitive single-photon counting detection. The single-photon counting imaging sensor developed in this work has a novel multiple-event architecture, which allows each of its pixels to register as more than one million (or more) photon-counting events during a frame time. Because of a consequently boosted dynamic range, the imaging array of the invention is capable of performing single-photon counting under ultra-low light through high-flux environments. On the other hand, since the multiple-event architecture is implemented in a hybrid structure, back-illumination and close-to-unity fill factor can be realized, and maximized quantum efficiency can also be achieved in the detector array.

Zheng, Xinyu↗

The Earth Occultation Technique with the Burst and Transient Source Experiment

The Burst and Transient Source Experiment (BATSE) on the Compton Gamma Ray Observatory (CGRO) is successfully being used as an all-sky hard X-ray monitor. The experiment consists of a set of eight uncollimated detectors sensitive to photons in the 20 keV to 2 MeV range. Since CGRO orbits the Earth at an altitude of about 450 km, about 33% of the sky, as viewed with BATSE, is covered by the Earth at any given time. The entire sky is subject to Earth occultation for some portion of CGRO's 52 day precession period. When a source sets below or rises above the Earth's limb, atmospheric attenuation produces step-like features in the BATSE data. The observed change in count rate in several energy bands provides a measurement of the source intensity and spectrum without sophisticated background models. These occultation features are used to locate and monitor astrophysical sources with BATSE when the source signal can be separated from the detector background. Examples of step searches, spectra, light curves, and transform imaging are presented.

Wilson, C. A.↗