Search NASA⌕ Search

SEARCH · Search NASA

Results for “planner”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

A Risk-Averse Approach for Distribution Grid Expansion Planning

Recent episodes of natural disasters have challenged the resilience of power grids. Adequate distribution grid planning that properly captures the risk aversion of the utility system planner is a key factor to increase the flexibility of distribution networks to circumvent these events. In this paper, we propose a methodology to determine the optimal portfolio of investments in lines and storage devices in order to minimize a convex combination between expected value and CVaR of operational costs, including energy not served, while taking into account the multistage nature of the energy storage management within this context. While the expected value of energy not served has been traditionally employed to tackle routine failures, we also minimize the CVaR of energy not served to address high-impact, low-probability (HILP) events. We illustrate the performance of the proposed methodology with a 54-Bus system test case.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simple Diesel Train Fuel Consumption Model for Real-Time Train Applications

This paper introduces a simple diesel train energy consumption model that calculates the instantaneous energy consumption using vehicle operational input variables, including the instantaneous speed, acceleration, and roadway grade, which can be easily obtained from global positioning system (GPS) loggers. The model was tested against real-world data and produced an error of -1.33% for all data and errors ranging from -12.4% to +8.0% for energy consumption of four train datasets amounting to a total of 5854 km trips. The study also validated the proposed model with separate data that were collected between Valencia and Cuenca, Spain, which had a total length of 198 km and found that the model was accurate, yielding a relative error of -1.55% for the total energy consumption. These results show that the proposed model can be used by train operators, transportation planners, policy makers, and environmental engineers to evaluate the energy consumption effects of train operational projects and train simulation within intermodal transportation planning tools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Proposed Algorithm for Placement and Sizing of Generation and Storage Stations in Urban Environments

The placement of generation and storage stations (GSSs) in distribution grids has been extensively investigated. Most traditional methods are applicable to rural or homogeneous environments and do not account for external restrictions on generation placement in urban or semi-urban environments. In this article, we propose a method for generation placement considering externality constraints. New utility-scale generation in distribution grids potentially occupies footprint and interferes in areas with existing infrastructure with architectural, historical, or touristic value. Urban environments are often regulated by municipal legislation. The placement of utility-scale generation in urban landscapes is economically and physically restricted by such externalities, and existing methods for generation placement in distribution grids based on technical optimization fail to account for this important nuance. The proposed algorithm flexibly adapts to changes in government energy policies and priorities. The selection of the type of generation suitable for the power grid is left to the preference of external high-level stakeholders, such as urban planners, industry development leaders, and energy policymakers. The proposed algorithm is a unique tool for determining the placement and sizing of generation in realistic conditions in distribution grids; it is adaptable to urban externalities and sensitive to stakeholder preferences.

generation and storage station placement↗

A Comparative Study of Machine Learning Algorithms for Industry-Specific Freight Generation Model

According to Bureau of Transportation Statistics, the U.S. transportation system handled 14,329 million ton-miles of freight per day in 2020. Understanding the generation of these freight shipments is crucial for transportation researchers, planners, and policymakers to design and plan for a more efficient and connected freight transportation system. Traditionally, the freight generation modeling has been based on Ordinary Least Square (OLS) regression, although more advanced Machine Learning (ML) algorithms have been evaluated and proven to have excellent performance in various transportation applications in recent years. Furthermore, one modeling approach applied for one industry might not always be applicable for another as their freight generation logics can be quite different. The objective of this study is to apply and evaluate alternative ML algorithms in the estimation of freight generation for each of 45 industry types. Seven alternative ML algorithms, along with the base OLS regression, were evaluated and compared. In addition, the study considered different combinations of variables in both the original and logarithmic form as well as hyperparameters of those ML algorithms in the model selection for each industry type. The results showed statistically significant improvements in the root mean square error reduction by the alternative ML algorithms over the OLS for over 80% of cases. The study suggests utilizing the alternative ML algorithms can reduce the root mean square error by about 30%, depending on industry types.

97 MATHEMATICS AND COMPUTING↗

A system of shared autonomous vehicles for Chicago: Understanding the effects of geofencing the service

With autonomous vehicles (AVs) still in the testing phase, researchers and planners must resort to simulation techniques to explore possible futures regarding shared and automated mobility. An agent-based discrete-event transport simulator, POLARIS, is used in this study to simulate travel in the 20-county Chicago region with a shared AV (SAV) mobility option. Using this framework, the effect of an SAV fleet on system performance when constrained to serve within geofences is studied under four distinct scenarios: service restricted to the city, to the city plus suburban core, to the core plus exurban areas, and to the entire region — along with the choice of dynamic ridesharing (DRS) versus solo travel in an SAV. Results indicate that service areas need a balanced mix of trip generators and attractors, and an SAV fleet’s empty VMT (eVMT) can be noticeably reduced through suitable geofencing and DRS. Geofences can also help lower response times, reduce systemwide VMT across all modes, and ensure uniform access to SAVs. DRS is most useful in lowering VMT and %eVMT that arises from sprawled land development, but with insufficient demand to share rides, savings from the use of geofences is higher. Geofences targeting neighborhoods with high trip density bring about low response times and %eVMT, but fleet sizes in these regions need to be designed for uniformly low response times throughout a large region, as opposed to maximizing vehicle use in a 24-hour day.

33 ADVANCED PROPULSION SYSTEMS↗

Datasets for Widespread Residential Space Heating Electrification in Texas

In this experiment, we explore long term patterns in electricity demand driven by the dual effects of full electrification of space heating in Texas (by adoption of electric heat pumps), and climate change. We use a predictive model of electricity demand, climate projections, and an open source nodal power system (DC Optimal Power Flow) model of the Electric Reliability Council of Texas (ERCOT) system. Heat pumps are a more energy efficient way of providing space heating and cooling in homes. We attempt to exhaustively investigate the impacts of full residential space heating electrification by adoption of heat pumps for the segment of Texas households that currently rely on fossil fuels (about 40%), while simultaneously incorporating climate change meteorological variables. We explore a range of scenarios of heat pump efficiency and climate uncertainty over a long period of future years (2020-2099). In total, the simulation experiment generates 1,280 simulation years of hourly data. We report and analyze results in form of impacts on residential load, total load, peak load, seasonality of peaking, and reliability measured by occurrence and frequency of loss of load events. While the experiment is for ERCOT, the insights and approach can be applied to other regions. The results from the analysis can inform system planners on a range of potential capacity requirements/ reliability implications and/or risks of full space heating electrification via the adoption of electric heat pumps, given the uncertainty in the scenarios/ climate futures. The dataset includes model output for residential, non residential and total load, and the results from the GO ERCOT model runs for 4 RCP Scenarios (RCP 4.5 Cooler, RCP 4.5 Hotter, RCP 8.5 Cooler, RCP 8.5 Hotter), 4 Heating electrification Scenarios (Base , Standard Efficiency HP, High Efficiency HP, Ultra-High Efficiency HP) over 80 years (2020-2099). The metrological variables at BA scale were weighted weighted using population projections consistent with the SSP3 scenario.

Climate Change↗

Navigating Epistemic Uncertainty in the Management of Flash Droughts

Abstract: Flash droughts, characterized by their rapid onset, sharply contrast with the typically gradual development of traditional droughts. These events are triggered by a combination of low rainfall and high evaporation rates, driven by elevated temperatures, making them particularly challenging to predict and prepare for. As a relatively new concept, flash drought is not well understood, which introduces significant epistemic uncertainties regarding their nature and detection methods. This under-detection hinders planners' ability to effectively manage these events. Despite these uncertainties, flash droughts can have significant impacts, raising the question: how can decision-makers prepare for such events given the current knowledge gaps? To address this, we propose a methodological framework aimed at enhancing flash drought preparedness by guiding the selection of appropriate indicators based on their detection capabilities and the decision-makers' level of risk aversion. Our approach involves evaluating six different flash drought indicators and analyzing the level of agreement among them. Additionally, we consider the decision-makers' risk aversion, distinguishing between those who require consensus across all methods (risk-takers) and those who act based on a single method's indication (risk-averse). The insights gained from this study offer a pathway towards more informed decision-making processes regarding flash droughts, potentially mitigating their adverse effects through better preparedness and response strategies.

climate resilience↗

Strategic Pathways for Indigenous Resilient and Innovative Transportation

This presentation details the results of the project, titled Strategic Pathways for Indigenous Resilient and Innovative Transportation. The project culminated in a guidebook for Tribes interested in pursuing public EV charging infrastructure. The guidebook is designed to serve Tribal planners, Tribal departments of transportation, environmental offices, Tribal enterprises, Tribal utility authorities, Tribal leadership, and any other interested parties. The conference presentation will provide details on the engagement conducted during the project to inform the project publications. The presentation will also discuss Tribal sovereignty-related considerations for EV charging infrastructure topics including O&M and working with the electric utility.

33 ADVANCED PROPULSION SYSTEMS↗

Environmental Trade-Offs for a Process Utilizing Aerobic Respiration for Biological Conversion of Cellulosic Biomass-Derived Sugars to Hydrocarbons (Renewable Diesel Blendstock): Cooperative Research and Development Final Report, CRADA Number CRD-18-00765, Project 1

Phase II work is meant to develop an advanced understanding of how production of a renewable diesel blendstock from lignocellulosic biomass feedstocks via aerobic respiration at different production scales affects emissions of criteria pollutants and greenhouse gases (GHGs), local and regional air quality. The results could inform decisions by stakeholders (e.g., industry, community, air quality planners, investors) regarding relationships and tradeoffs between multiple environmental impacts and the challenges and opportunities for the design and deployment of a sustainable biofuel supply chain.

09 BIOMASS FUELS↗

Cybersecurity Risk Profiles for Distributed Energy Resource Management Systems

Managing the digitalization of increasingly diversity energy resources is a complex challenge for energy systems planners and managers. As the penetration of solar photovoltaics (PV) and other distributed renewable energy resources (DERs) expands, distributed energy resource management systems (DERMS) will play an increasingly important role in managing, monitoring, and controlling DERs as electric systems before more distributed, interconnected, and networked. However, the cybersecurity implications of DERMS deployments are not well understood today. A lack of understanding around the cybersecurity implications of DERMS deployments and variability in the security posture of DERMS vendors, owners, and operators could introduce new security risks to evolving electric power systems. This paper describes cybersecurity attack scenarios on DERMS, identifies related cybersecurity standards and guidelines, reviews the security features of state-of-the-art DERMS solutions, and offers cybersecurity guidance for DERMS vendors, owners, and operators to protect DERMS' unique capabilities. Standardizing cybersecurity requirements for DERMS could help improve the security of DERMS integrations and improve innovations that are more secure by design. The cybersecurity guidance found in this paper is intended to offer a unified approach and lay the foundation for future standardization of DERMS cybersecurity to reduce risk to the solar industry and other renewable energy stakeholders when integrating these technologies with electric power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Master Planning for Resilient Public Communities—Best Practices from U.S. Military Installations

Until recently, most planners at military installations addressed energy systems for new facilities on an individual facility basis without consideration of community-wide goals relevant to energy sources, renewables, storage, or future energy generation needs. Building retrofits of public buildings typically do not address energy needs beyond the minimum code requirements making it difficult, if not impossible, to achieve community-level targets on a building-by-building basis. Planning on the basis of cost and general reliability may also fail to deliver community-level resilience. For example, many building code requirements focus on hardening to specific threats, but in a multi-building community, only a few of these buildings may be mission-critical. Over the past two decades, the frequency and duration of regional power outages and water utility disruptions from weather, man-made events, and aging infrastructure have increased. Major disruptions of electric and thermal energy have degraded critical mission capabilities and caused significant economic impacts. In 2016, the U.S. Department of Defense issued guidance that each Service (Army, Navy, Air Force, Marines) complete comprehensive energy plans for the installations that consumed 75% of total building energy. Guidance was updated in 2017 to include metrics for energy resilience, and in some cases, water. This paper describes how community level quantitative and qualitative resilience analysis and metrics have been incorporated into community energy and water planning best practices for military installations in three geographically diverse locations. It is based on research performed under the International Energy Agency’s “Energy in Buildings and Communities Program Annex 73,” focusing on development of guidelines and tools that support the planning of Net Zero Energy Resilient Public Communities as well as research performed under the Department of Defense Environmental Security Technology Certification Program project EW18-D1- 5281, “Technologies Integration to Achieve Resilient, Low- Energy Military Installations.” The first case study reviews progress made on an energy and water planning study conducted at Fort Bliss, Texas. The second and third describes planning conducted at Fort Bragg, North Carolina and the Joint Region Marianas, Guam, respectively, under the updated guidance from 2017 regarding energy and water resilience. Analysis methods, key metrics, and key infrastructure and operational constraints are described, as well as technical, economic and business concepts used during the planning process.

Urban, Angela B.↗

Assessing Cost-Optimal Battery Energy and Solar-Plus-Storage Systems for Federal Customers: A Nationwide Assessment: Preprint

Prior research has identified that the financial viability of behind-the-meter battery energy storage systems is heavily dependent on technology cost, utility rate structure, energy consumption patterns, and co-deployment with synergistic technologies like solar photovoltaics (PV), among other factors. This study builds on existing research by comprehensively evaluating the economics of battery energy storage systems (BESS) and solar-plus-storage systems for a reference office building at 755 reference sites under 834 utility rates, and four storage capital cost scenarios. Results indicate that even with dramatic cost reductions, BESS is likely to be cost-effective only under utility rates that include demand charges, and possibly include time-of-use (TOU) pricing as well. Even under these utility rates, BESS systems provide marginal savings, and office building operators are unlikely to deploy the technology for cost savings alone. Solar-plus-storage systems provide more savings than BESS and allow for larger economic storage capacities. Solar-plus-storage provides compelling savings opportunities at baseline prices, and even at capital costs 25% higher than baseline. Solar-plus-storage is most effective where there are demand charges and energy pricing schemes include TOU pricing, or where electricity is expensive (at least $0.30/kWh). Our case studies illustrate that the presence of demand charges, even at similar energy costs, can be the deciding factor in BESS and solar-plus-storage viability. The findings and maps from this assessment may be of use to planners, building owners, and developers looking for potentially economic storage opportunities.

battery energy storage systems↗

Livewire Data Platform: A Catalog of Transportation and Mobility Data

A two-page fact sheet on the capabilities and core services of the Livewire Data Platform, a growing catalog of transportation and mobility-related data that empowers researchers and community planners to easily and securely share and preserve data that support projects and decision making.

47 OTHER INSTRUMENTATION↗

Livewire Data Platform: A Catalog of Transportation and Mobility Data

A two-page fact sheet on the capabilities and core services of the Livewire Data Platform, a growing catalog of transportation and mobility-related data that empowers researchers and community planners to easily and securely share and preserve data that support projects and decision making.

Livewire, EEMS, energy-efficient mobility systems,↗

RAVIS: Resource Forecast and Ramp Visualization for Situational Awareness of Variable Renewable Generation: Preprint

The Resource Forecast and Ramp Visualization for Situational Awareness (RAVIS) is an innovative, open-source tool for visualizing variable renewable resource forecasts and alerts for significant up- and down-ramps in renewable generation and the consequent system net load. The modular dashboard of RAVIS contains configurable panes for viewing probabilistic time-series forecasts, ramp event alerts on the look-ahead timeline, and spatially resolved resource sites, and forecasts. For comprehensive situational awareness, the tool can add additional data layers from simulation and independent system operator (ISO) market clearing data—including electric line utilization, nodal price, and available generation flexibility—in response to continuously updated renewable forecasts. This paper introduces the RAVIS technology suite employed to provide optimum visualization and flexible design characteristics. The paper also illustrates some use cases of the tool using site-specific solar power forecast data obtained from the IBM Watt-Sun forecasting platform for the California ISO and Midcontinent ISO footprints. The source code for RAVIS is public (https://github.com/ravis-nrel/ravis), and the intended users are forecasters, utility planners, ISO operators, and researchers.

41 EE - Solar Energy Technologies Office (EE-4S)↗

A Decision Support Framework for Grid-Aware Electric Bus Charge Scheduling

While there are many advantages to electric public transit vehicles, they also pose new challenges for fleet operators. One key challenge is defining a charge scheduling policy that minimizes operating costs and power grid disruptions while maintaining schedule adherence. An uncoordinated policy could result in some buses running out of charge before completing their trip, while a grid agnostic policy might incur higher energy costs or cause an adverse impact on the grid’s distribution system. We present a grid aware decision-theoretic framework for electric bus charge scheduling that accounts for energy price, grid load, and bus status. The framework connects environmental models for traffic (SUMO) and the electric grid (GridLAB-D) to a planner, which evaluates bus charging decisions with regard to their long-term effect on grid reliability and cost. The framework has been evaluated on a simulation of Richland, WA’s bus and grid network, and compared to greedy methods.

EV, machine leaning, EV-Grid, Transportation, Grid↗

State, Local, and Tribal Technical Support Services Agreement

This fact sheet summarizes the National Renewable Energy Laboratory’s (NREL’s) State, Local, and Tribal Technical Support Services Agreement contract mechanism. The service extends the benefits of national laboratory expertise to state and local energy project decision makers and planners charting the course to a clean energy future.

48 EE - Weatherization and Intergovernmental Progr↗

Long-Term Planning for the Tamil Nadu Power System

Increased deployment of wind and solar raises new questions for power system planners regarding the future mix of generation technologies, optimal siting of generation capacity, trade-offs between generation and transmission investments, and system flexibility needs. The National Renewable Energy Laboratory (NREL) is working with Tamil Nadu Generation and Distribution Company (TANGEDCO) to answer the following questions: How much—and what type—of generation and transmission investments are needed to serve future demand at least cost? How can variable resources such as wind and solar be considered in the planning process? What are the key drivers (e.g., policies, technology costs, fuel constraints) for investments?

Children's Investment Fund Foundation↗