Search NASA⌕ Search

SEARCH · Search NASA

Results for “protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

A harmonized protocol to assess the single-cell performance of proton exchange membrane water electrolyzers

The harmonization of testing protocols for proton exchange membrane (PEM) electrolyzers is essential for ensuring accurate and reliable performance assessments and accelerating the development of hydrogen production technologies. This protocol provides a structured approach to PEM electrolyzer setup and testing, incorporating key considerations for test station design and single-cell characterization techniques. Polarization curves and electrochemical impedance spectroscopy (EIS) are detailed, along with best practices from academic and industry research groups to enhance data accuracy and comparability. By addressing material variability and harmonizing testing methodologies, this framework enables more precise evaluations of membrane electrode assemblies and electrolyzer components. Harmonized protocols not only streamline development efforts but also foster collaboration across institutions, ultimately supporting the commercialization of hydrogen solutions through improved stack efficiency and durability.

08 HYDROGEN↗

A Blockchain and PKI-Based Secure Vehicle-to-Vehicle Energy-Trading Protocol

With the increasing awareness for sustainable future and green energy, the demand for electric vehicles (EVs) is growing rapidly, thus placing immense pressure on the energy grid. To alleviate this, local trading between EVs should be encouraged. In this paper, we propose a blockchain and public key infrastructure (PKI)-based secure vehicle-to-vehicle (V2V) energy-trading protocol. A permissioned blockchain utilizing the proof of authority (PoA) consensus and smart contracts is used to securely store data. Encrypted communication is ensured through transport layer security (TLS), with PKI managing the necessary digital certificates and keys. A multi-leader, multi-follower Stackelberg game-based trade algorithm is formulated to determine the optimal energy demands, supplies, and prices. Finally, we propose a detailed communication protocol that ties all the components together, enabling smooth interaction between them. Key findings, such as system behavior and performance, scalability of the trade algorithm and the blockchain, smart contract execution costs, etc., are presented through numerical results by implementing and simulating the protocol in various scenarios. This work not only enhances local energy trading among EVs, encouraging efficient energy usage and reducing burden on the power grid, but also paves a way for future research in sustainable energy management.

Stackelberg game↗

(abstract) Experimental Results From Internetworking Data Applications Over Various Wireless Networks Using a Single Flexible Error Control Protocol

This paper describes results from several wireless field trials in New Jersey, California, and Colorado, conducted jointly by researchers at Bellcore, JPL, and US West over the course of 1993 and 1994. During these trials, applications communicated over multiple wireless networks including satellite, low power PCS, high power cellular, packet data, and the wireline Public Switched Telecommunications Network (PSTN). Key goals included 1) designing data applications and an API suited to mobile users, 2) investigating internetworking issues, 3) characterizing wireless networks under various field conditions, and 4) comparing the performance of different protocol mechanisms over the diverse networks and applications. We describe experimental results for different protocol mechanisms and parameters, such as acknowledgment schemes and packet sizes. We show the need for powerful error control mechanisms such as selective acknowledgements and combining data from multiple transmissions. We highlight the possibility of a common protocol for all wireless networks, from micro-cellular PCS to satellite networks.

wireless networks field trials mobile users protoc↗

A network architecture for precision formation flying using the IEEE 802.11 MAC Protocol

Precision Formation Flying missions involve the tracking and maintenance of spacecraft in a desired geometric formation. The strong coupling of spacecraft in formation flying control requires inter-spacecraft communication to exchange information. In this paper, we present a network architecture that supports PFF control, from the initial random deployment phase to the final formation. We show that a suitable MAC layer for the application protocol is IEEE's 802.11 MAC protocol. IEEE 802.11 MAC has two modes of operations: DCF and PCF. We show that DCF is suitable for the initial deployment phase while switching to PCF when the spacecraft are in formation improves jitter and throughput. We also consider the effect of routing on protocol performance and suggest when it is profitable to turn off route discovery to achieve better network performance.

precision formation flying↗

Analysis of Proximity-1 Space Link Interleaved Time Synchronization (PITS) Protocol

To synchronize clocks between spacecraft in proximity, the Proximity-1 Space Link Interleaved Time Synchronization (PITS) Protocol has been proposed. PITS is based on the NTP Interleaved On-Wire Protocol and is capable of being adapted and integrated into CCSDS Proximity-1 Space Link Protocol with minimal modifications. In this work, we will discuss the correctness and liveness of PITS. Further, we analyze and evaluate the performance of time synchronization latency with various channel error rates in different PITS operational modes.

network time protocol↗

30th Anniversary of the Montreal Protocol: from the Safeguard of the Ozone Layer to the Protection of the Earth's Climate

The year 2017 marked the celebration of the 30th anniversary of the Montreal Protocol on Substances that Deplete the Ozone Layer. Hailed as an outstanding example of international cooperation for environmental protection, the Montreal Protocol, signed on September 16th, 1987, became the first international treaty to achieve universal ratification in 2010. This Protocol has halted the destruction of the ozone layer by controlling the production and consumption of ozone-depleting substances (ODSs).

Montreal Protocol↗

Network Emulation Testbed Capabilities for Prototyping Space DTN Software and Protocols

This paper delves into network emulation tools essential for evaluating and designing Delay Tolerant Networking (DTN) protocols in space and satellite networking. It surveys and assesses the capability of current testbeds to create realistic test environments crucial for developing and evaluating DTN protocols. Specifically, this study provides a comprehensive overview of key DTN protocol stacks and related network emulation platforms and a detailed exploration of NASA’s research facilities. Finally, the paper underscores the fundamental emulation capabilities and the importance of a standardized framework for scenario creation, highlighting its vital role in evaluating and advancing future emulation platforms for space DTN.

Network Emulation and Simulation↗

Separation Assurance in Urban Air Mobility Systems Using Shared Scheduling Protocols

Ensuring safe separation between aircraft is a critical challenge in air traffic management, particularly in urban air mobility (UAM) environments where high traffic density and low altitudes require precise control. In these environments, conflicts often arise at the intersections of flight corridors, posing significant risks. We propose a tactical separation approach leveraging shared scheduling protocols, originally designed for Ethernet networks and operating systems, to coordinate access to these intersections. Using a decentralized Markov decision process framework, the proposed approach enables aircraft to autonomously adjust their speed and timing as they navigate these critical areas, maintaining safe separation without a central controller. We evaluate the effectiveness of this approach in simulated UAM scenarios, demonstrating its ability to reduce separation violations to zero while acknowledging trade-offs in flight times as traffic density increases. Additionally, we explore the impact of non-compliant aircraft, showing that while shared scheduling protocols can no longer guarantee safe separation, they still provide significant improvements over systems without scheduling protocols.

Separation Assurance↗

Building America Indoor Temperature and Humidity Measurement Protocol

When modeling homes using simulation tools, the heating and cooling set points can have a significant impact on home energy use. Every 4 years the Energy Information Administration (EIA) Residential Energy Consumption Survey (RECS) asks homeowners about their heating and cooling set points. Unfortunately, no temperature data is measured, and most of the time, the homeowner may be guessing at this number. Even one degree Fahrenheit difference in heating set point can make a 5% difference in heating energy use! So, the survey-based RECS data cannot be used as the definitive reference for the set point for the 'average occupant' in simulations. The purpose of this document is to develop a protocol for collecting consistent data for heating/cooling set points and relative humidity so that an average set point can be determined for asset energy models in residential buildings. This document covers the decision making process for researchers to determine how many sensors should be placed in each home, where to put those sensors, and what kind of asset data should be taken while they are in the home. The authors attempted to design the protocols to maximize the value of this study and minimize the resources required to achieve that value.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Building America Indoor Temperature and Humidity Measurement Protocol

When modeling homes using simulation tools, the heating and cooling set points can have a significant impact on home energy use. Every four years, the Energy Information Administration (EIA) Residential Energy Consumption Survey (RECS) asks homeowners about their heating and cooling set points. Unfortunately, no temperature data is measured, and most of the time, the homeowner may be guessing at this number. Even one degree Fahrenheit difference in heating set point can make a 5% difference in heating energy use! So, the survey-based RECS data cannot be used as the definitive reference for the set point for the "average occupant" in simulations. The purpose of this document is to develop a protocol for collecting consistent data for heating/cooling set points and relative humidity so that an average set point can be determined for asset energy models in residential buildings. This document covers the decision making process for researchers to determine how many sensors should be placed in each home, where to put those sensors, and what kind of asset data should be taken while they are in the home. The authors attempted to design the protocols to maximize the value of this study and minimize the resources required to achieve that value.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

AIMD‐Based Protocols for Modeling Exciplex Fluorescence Spectra and Inter‐System Crossing in Photocatalytic Chromophores

ABSTRACT This study introduces a computational protocol for modeling the emission spectra of exciplexes using excited‐state ab initio molecular dynamics (AIMD) simulations. The protocol is applied to a model exciplex formed by oligo‐p‐phenylenes (OPPs) and triethylamine (TEA), which is of interest in the context of photocatalytic reduction of . AIMD facilitates efficient sampling of the conformational space of OPP3 and OPP4 exciplexes with TEA, offering a dynamic alternative to previously employed static methods. The AIMD‐based protocol successfully reproduces experimental emission spectra for OPP‐TEA exciplexes, agreeing with previous computational and experimental findings. The results show that AIMD simulations provide an efficient means of sampling the conformational space of these exciplexes, requiring less user input and, in some instances, fewer computational resources than multiple excited‐state optimizations initiated from user‐specified initial structures. The study also evaluates the yield of intersystem crossing (ISC) using AIMD and Landau‐Zener probability. The results suggest that ISC is a minor decay channel for OPP3 and OPP4. This work provides new insights into the structural flexibility and emission characteristics of OPP‐TEA photoredox catalyst systems, potentially contributing to improved design strategies for organic chromophores in reduction applications.

Giudetti, Goran [Department of Chemistry Universit↗

A Systematic Review of Protocols for the Three-Dimensional Morphologic Assessment of Abdominal Aortic Aneurysms Using Computed Tomographic Angiography

The morphology of infrarenal abdominal aortic aneurysms (AAAs) directly influences the perioperative outcome and long-term durability of endovascular aneurysm repair. A variety of methods have been proposed for the characterization of AAA morphology using reconstructed three-dimensional (3D) computed tomography (CT) images. At present, there is lack of consensus as to which of these methods is most applicable to clinical practice or research. The purpose of this review was to evaluate existing protocols that used 3D CT images in the assessment of various aspects of AAA morphology. An electronic search was performed, from January 1996 to the end of October 2010, using the Embase and Medline databases. The literature review conformed to PRISMA statement standards. The literature search identified 604 articles, of which 31 studies met inclusion criteria. Only 15 of 31 studies objectively assessed reproducibility. Existing published protocols were insufficient to define a single evidence-based methodology for preoperative assessment of AAA morphology. Further development and expert consensus are required to establish a standardized and validated protocol to determine precisely how morphology relates to outcomes after endovascular aneurysm repair.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of imaging protocol on left ventricular ejection fraction using gated-SPECT myocardial perfusion imaging

Background: There are limited data on the impact of the imaging protocol (single-day stress-rest, SD, vs. dual-day, DD) on the change in left ventricular (LV) ejection fraction (EF) (post-stress-rest) in relation to ischemia and on outcome. Methods: Using propensity score matching procedure, 490 of 1121 patients with known CAD, undergoing a SD or a DD in a multicenter study, were evaluated. Stress and rest gated-SPECT myocardial perfusion imaging was used to quantify LV perfusion, EF, and volumes. Outcome was assessed at an average follow-up time of 3.2 years. Results: Post-stress LVEF in SD and DD were comparable across all degrees of ischemia. The change in LVEF in patients with severe ischemia was, however, higher in the DD protocol, independent of the extent of CAD. At follow-up, 240 patients (49.0%) required coronary revascularization (CR) and 52 patients (10.6%) had hard events. The ischemic burden was independently associated with CR and hard-events; the post-stress LVEF was associated with CR but the change in EF was not predictive of either CR or hard events. Conclusions: In patients with severe ischemia, underestimation of post-stress myocardial stunning could be observed with the SD protocol. Post-stress LVEF and the extent ischemia, but not the change in EF, are predictive of CR and hard events.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A combined static-dynamic single-dose imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT

Background: SPECT myocardial perfusion imaging (MPI) is a clinical mainstay that is typically performed with static imaging protocols and visually or semi-quantitatively assessed for perfusion defects based upon the relative intensity of myocardial regions. Dynamic cardiac SPECT presents a new imaging technique based on time-varying information of radiotracer distribution, which permits the evaluation of regional myocardial blood flow (MBF) and coronary flow reserve (CFR). In this work, a preliminary feasibility study was conducted in a small patient sample designed to implement a unique combined static-dynamic single-dose one-day visit imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT for improving the diagnosis of coronary artery disease (CAD). Methods: Fifteen patients (11 males, four females, mean age 71 ± 9 years) were enrolled for a combined dynamic and static SPECT (Infinia Hawkeye 4, GE Healthcare) imaging protocol with a single dose of {sup 99m}Tc-tetrofosmin administered at rest and a single dose administered at stress in a one-day visit. Out of 15 patients, eleven had selective coronary angiography (SCA), 8 within 6 months and the rest within 24 months of SPECT imaging, without intervening symptoms or interventions. The extent and severity of perfusion defects in each myocardial region was graded visually. Dynamically acquired data were also used to estimate the MBF and CFR. Both visually graded images and estimated CFR were tested against SCA as a reference to evaluate the validity of the methods. Results: Overall, conventional static SPECT was normal in ten patients and abnormal in five patients, dynamic SPECT was normal in 12 patients and abnormal in three patients, and CFR from dynamic SPECT was normal in nine patients and abnormal in six patients. Among those 11 patients with SCA, conventional SPECT was normal in 5, 3 with documented CAD on SCA with an overall accuracy of 64%, sensitivity of 40% and specificity of 83%. Dynamic SPECT image analysis also produced a similar accuracy, sensitivity, and specificity. CFR was normal in 6, each with CAD on SCA with an overall accuracy of 91%, sensitivity of 80%, and specificity of 100%. The mean CFR was significantly lower for SCA detected abnormal than for normal patients (3.86±1.06 vs 1.94±0. 0.67, P < 0.001). Conclusions: The visually assessed image findings in static and dynamic SPECT are subjective, and may not reflect direct physiologic measures of coronary lesion based on SCA. The CFR measured with dynamic SPECT is fully objective, with better sensitivity and specificity, available only with the data generated from the dynamic SPECT method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How variable are the volumetric measurements from gated perfusion SPECT when a one-day stress-rest protocol is used?

Background: Using myocardial perfusion scintigraphy (MPS), an increase in left ventricular (LV) volumes or a decrease in ejection fraction (EF) from rest to stress may be clinically important. The variation in these measures between the low-dose stress acquisition and high-dose rest acquisition in a one-day stress-rest protocol has not been established. We assessed the reproducibility of gated volumetric indices between stress and rest and the normal variation in ungated TID ratio for a one-day stress-rest {sup 99m}Tc-tetrofosmin protocol. Methods: Two thousand and one hundred and fifty eight (2158) {sup 99m}Tc-tetrofosmin MPS patient studies were analyzed retrospectively. Studies were excluded for incomplete data, significant technical difficulties, or (for gated analysis but not for analysis of TID ratio) if the LV EF was > 75%. An analysis of gated data was undertaken to establish the reproducibility of ventricular volumes and EF between stress and rest scans. Ungated volume data were analyzed to determine the confidence limits of TID ratio according to ventricular volume. Results: Gated data were analyzed for 621 patients without inducible hypoperfusion. Mean EF at rest was slightly higher than after stress (62.4% ± 10.3% vs 61.2% ± 10.4%, P < 0.001), and the standard deviation of the difference was 5.2% (95% CI 4.9% to 5.5%). Ungated volumes were available for 992 non-ischaemic patients. The upper 95% CI for TID ratio was 1.23. This increased from 1.20 to 1.37 between the highest and lowest deciles of rest ungated volume. Conclusion: Using a one-day stress-rest {sup 99m}Tc-tetrofosmin protocol, a fall in LV EF between rest and stress of > 11.6% or a TID ratio of > 1.23 is likely to be clinically reliable. The upper limit of normal for TID ratio needs to be increased for patients with small LV chamber volumes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proof-of-concept studies of novel protocols for producing highly pure 48 V from a 48 Cr/ 48 V generator

Here, the quest to improve the quality of nuclear data, such as half-lives, transition yields, and reaction cross-sections, is a shared endeavor among various areas of nuclear science. 48 V is a vanadium isotope for which experimental data on neutron reaction cross-sections is needed. However, traditional isotope production techniques cannot produce 48 V with high enough isotopic purity for some of these measurements. “Isotope harvesting” at the Facility for Rare Isotope Beams (FRIB) is a new isotope production technique that could potentially yield 48 V with the necessary purity for such studies. In this case, 48Cr would be collected and allowed to generate 48 V that can be separated from undecayed 48 Cr to yield highly pure 48 V. Thus, any protocol for producing pure 48 V via isotope harvesting would involve utilizing a separation technique that can effectively separate 48 Cr and 48 V. In this study, the radiotracers 51 Cr and 48 V were used to develop possible radiochemical separation methodologies, which can be translated to obtain high purity 48 V via this novel isotope production method. The developed protocols utilize either ion exchange or extraction chromatographic resins. Separations of 51 Cr and 48 V with AG 1-X8 anion exchange resin respectively resulted in recoveries of 95.6(26)% and 96.2(12)% with radionuclidic purities of 92(2)% and 99(1)%. An even more effective Cr and V separation was obtained with an extraction chromatographic resin (TRU resin) and 10 M HNO 3 loading solution. Here, 51 Cr and 48 V respectively had recoveries of 94.1(28)% and 96.2(13)% with high radionuclidic purities (100(2)% and 100(1)%) in small volumes (8.81(8) mL and 5.39(16) mL). This study suggests that, to maximize the yield and isotopic purity of 48 V, the best production protocol would involve utilizing two separations with TRU resin and 10 M HNO 3 to isolate 48 Cr and purify the generated 48 V.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Optimizing a chemical cleaning protocol to determine the nickel isotopic composition of ancient seawater from carbonates

Reconstructing the ancient marine cycle of Ni, a trace metal in the oceans essential to enzymes regulating the C, N, and O cycles, would inform how Ni bioavailability shaped early life. The Ni isotopic composition of seawater (δ 60 Ni SW ) through time could provide insight, but this approach requires sedimentary archives that faithfully record δ 60 Ni SW . Carbonates are an often-used record of seawater chemistry, but contaminants could bias the measured δ 60 Ni of bulk sediment. To isolate the true carbonate-bound δ 60 Ni signal, we optimized a chemical cleaning protocol designed to minimize non‑carbonate Ni contributions and maximize carbonate recovery. We analyzed ODP Site 1007 sediments and evaluated oxidative and reductive pre-cleaning steps and carbonate dissolution protocols. Our results show that only reductive cleaning significantly altered the subsequent carbonate leachate composition, lowering Ni/Ca ratios by up to 60% and δ 60 Ni values by as much as 0.4 ‰. In contrast, δ 60 Ni values were largely insensitive to premature carbonate dissolution during pre-cleaning or to partial leaching of silicates during carbonate dissolution, even at higher acid molarities or longer reaction times. We recommend an evidence-based protocol that removes hydro-soluble salts and clays, applies reductive cleaning and oxidative cleaning for certain sample compositions, and dissolves carbonate using 0.5 M acetic acid, adjusted to pH 5. Using these results, we infer a ∼ 0.9 ‰ Ni isotopic fractionation between chemically cleaned deep-water carbonates (+0.4 ± 0.1 ‰) and deep seawater. This method development is a key step toward accurately reconstructing ancient marine Ni cycles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Clinical Experience With Image-Guided Radiotherapy in an Accelerated Partial Breast Intensity-Modulated Radiotherapy Protocol

Purpose: To explore the feasibility of fiducial markers for the use of image-guided radiotherapy (IGRT) in an accelerated partial breast intensity modulated radiotherapy protocol. Methods and Materials: Nineteen patients consented to an institutional review board approved protocol of accelerated partial breast intensity-modulated radiotherapy with fiducial marker placement and treatment with IGRT. Patients (1 patient with bilateral breast cancer; 20 total breasts) underwent ultrasound guided implantation of three 1.2- x 3-mm gold markers placed around the surgical cavity. For each patient, table shifts (inferior/superior, right/left lateral, and anterior/posterior) and minimum, maximum, mean error with standard deviation were recorded for each of the 10 BID treatments. The dose contribution of daily orthogonal films was also examined. Results: All IGRT patients underwent successful marker placement. In all, 200 IGRT treatment sessions were performed. The average vector displacement was 4 mm (range, 2-7 mm). The average superior/inferior shift was 2 mm (range, 0-5 mm), the average lateral shift was 2 mm (range, 1-4 mm), and the average anterior/posterior shift was 3 mm (range, 1 5 mm). Conclusions: This study shows that the use of IGRT can be successfully used in an accelerated partial breast intensity-modulated radiotherapy protocol. The authors believe that this technique has increased daily treatment accuracy and permitted reduction in the margin added to the clinical target volume to form the planning target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗