Search NASA⌕ Search

SEARCH · Search NASA

Results for “racking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

NLR HPC Eagle Node Power Data

Power time series captured from all Eagle nodes using iLO (Integrated Lights Out) The Eagle HPC operated at NLR from 2019 through 2024. Eagle was a 2,000-node, 8-petaflop system. This dataset is a comprehensive time series of instantaneous snapshots of power usage at 1 minute intervals from all nodes at the node level. Data provided in compressed Hive dataset/Parquet format. iLO Power Time Series Fields ts: Timestamp dv: Device / Node - Rack and Unit - r103u17 == r(ack)103u(nit)17 vl: Value - Value in watts (instantaneous value at sampling time) day month year

97 MATHEMATICS AND COMPUTING↗

NLR HPC Eagle GPU Node Metrics

Ganglia node metrics and iLO (Integrated Lights Out) power data captured from six representative Eagle GPU nodes The Eagle HPC operated at NLR from 2019 through 2024. Eagle was a 2,000-node, 8-petaflop system. This dataset is a representative sample of metrics for 6 of the GPU nodes. Each GPU node contained 2 CPUs and 2 GPUs. Data provided in compressed CSV format. Ganglia and iLO Power Time Series Fields ts: Timestamp dv: Device / Node - Rack and Unit - r103u17 == r(ack)103u(nit)17 mt: Metric (only present for Ganglia) vl: Value - Value in watts for iLO power (instantaneous value at sampling time) or specified Ganglia metric below Ganglia Metrics Metric name -- Metric description -- Unit cpu_aidle -- Percent of time since boot idle CPU -- Percent cpu_idle -- Percent CPU idle -- Percent cpu_nice -- Percent CPU nice -- Percent cpu_speed -- Speed in MHz of CPU -- MHz cpu_user -- Percent CPU user -- Percent cpu_wio -- The percentage of CPU Wait I/O -- Percent gpu0_bar1_memory -- Used GPU bar1 memory -- MB gpu0_decoder_util -- GPU decoder utilization -- Percent gpu0_ecc_db_error -- Total ECC error counts for the GPU -- Number gpu0_encoder_util -- GPU encoder utilization -- Percent gpu0_fan -- Fan speed -- RPM gpu0_fb_memory -- Used GPU framebuffer memory -- MB gpu0_graphics_clock_report -- Current clock speeds for the device -- MHz gpu0_mem_total -- Memory total -- MB gpu0_mem_util -- Memory utilization -- Percent gpu0_power_usage_report -- Power usage report -- Watts gpu0_temp -- GPU 1 temperature -- Celsius gpu1_bar1_memory -- Used GPU bar1 memory -- MB gpu1_decoder_util -- GPU decoder utilization -- Percent gpu1_ecc_db_error -- Total ECC error counts for the GPU -- Number gpu1_encoder_util -- GPU encoder utilization -- Percent gpu1_fan -- Fan speed -- RPM gpu1_fb_memory -- Used GPU framebuffer memory -- MB gpu1_graphics_clock_report -- Current clock speeds for the GPU -- MHz gpu1_mem_total -- Memory total -- MB gpu1_mem_util -- Memory utilization -- MB gpu1_power_usage_report -- Power usage report -- Watts gpu1_temp -- GPU 1 temperature -- Celsius ipmi_cpu1_temp -- CPU 1 temperature -- Celsius ipmi_cpu2_temp -- CPU 2 temperature -- Celsius ipmi_inlet_ambient_temp -- Temperature measured at intake -- Celsius ipmi_vr_p1_temp -- CPU 1 voltage regulator temperature -- Celsius ipmi_vr_p2_temp -- CPU 2 voltage regulator temperature -- Celsius mem_buffers -- Amount of buffered memory -- Bytes mem_cached -- Amount of cached memory -- Bytes mem_free -- Amount of available memory -- Bytes mem_shared -- Amount of shared memory -- Bytes mem_total -- Amount of available memory -- Bytes

97 MATHEMATICS AND COMPUTING↗

Special pliers connect hose containing liquid under pressure

For speed and safety in handling disconnect fittings on a hose carrying liquid under pressure, special pliers have been constructed. A gear and rack mechanism is combined with two or more wide-opening U-shaped jaws which are placed over the quick-disconnect fittings.

Blaydes, R. A.↗

Floating device aligns blind connections

Panel-mounted connectors overcome the misalignment of blind connectors in electronic rack mounted equipment. The connector is free to move in the vertical direction by the action of a parallelogram mount. This freedom of motion maintains the guide pin hole centerline parallel to the guide pin centerline at all times.

Resel, J. E.↗

Minicomputer-controlled programmed oscillator

Two programmed oscillators have been constructed, each using a low-cost minicomputer for the calculation and control functions, and each contained in a single rack of equipment. They are capable of operation in a phase-tracking mode as well as a frequency-tracking mode. When given an ephemeris suitable for the planet Venus, these units maintained phase coherence of better than 5 deg rms at 2388 MHz.

Winkelstein, R.↗

Exploratory screening tests of several alloys and coatings for automobile thermal reactors

A total of 23 materials (including uncoated ferritic and austenitic iron-base alloys, uncoated nickel and cobalt-base superalloys, and several different coatings on AISI 304 stainless steel) were screened as test coupons on a rack in an automobile thermal reactor. Test exposures were generally 51 hours including 142 thermal cycles of 10 minutes at 1010 + or - 30 C test coupon temperature and 7-minutes cool-down to about 510 C. Materials that exhibited corrosion resistance better than that of Hastelloy X include: a ferritic iron alloy with 6 weight percent aluminum; three nickel-base superalloys; two diffused-aluminum coatings on AISI 304; and a Ni-Cr slurry-sprayed coating on AISI 304. Preliminary comparison is made on the performance of the directly impinged coupons and a reactor core of the same material.

Oldrieve, R. E.↗

Corrosion study of bare and coated stainless steel

A program was conducted at Kennedy Space Center from February 1968 to February 1971 to evaluate the performance of austenitic stainless steel alloys used in fluid systems lines. For several years, there had been numerous failures of stainless steel hardware caused by pitting and stress corrosion cracking. Several alloys were evaluated for effectiveness of certain sacrificial-type protective coverings in preventing corrosion failures. Samples were tested in specially designed racks placed 91 meters (100 yards) above high-tide line at Cape Kennedy. It is concluded that: (1) unprotected tubing samples showed evidence of pitting initiation after 2 weeks; (2) although some alloys develop larger pits than others, it is probable that the actual pitting rate is independent of alloy type; (3) the deepest pitting occurred in the sheltered part of the samples; and (4) zinc-rich coatings and an aluminum-filled coating have afforded sacrificial protection against pitting for at least 28 months. It is believed that a much longer effective coating life can be expected.

Morrison, J. D.↗

Fault tolerant data management system

Described in detail are: (1) results obtained in modifying the onboard data management system software to a multiprocessor fault tolerant system; (2) a functional description of the prototype buffer I/O units; (3) description of modification to the ACADC and stimuli generating unit of the DTS; and (4) summaries and conclusions on techniques implemented in the rack and prototype buffers. Also documented is the work done in investigating techniques of high speed (5 Mbps) digital data transmission in the data bus environment. The application considered is a multiport data bus operating with the following constraints: no preferred stations; random bus access by all stations; all stations equally likely to source or sink data; no limit to the number of stations along the bus; no branching of the bus; and no restriction on station placement along the bus.

Gustin, W. M.↗

Heat pipe applications for the space shuttle.

Discussion of six specific applications for heat pipe (HP) devices on the space shuttle. These applications were chosen from 27 concepts formulated as part of a study to evaluate the potential benefits associated with HP use. The formulation process is briefly described along with the applications which evolved. The bulk of the discussion deals with the 'top' six - namely, HP radiators for waste heat rejection, an HP augmented cold rail, an HP circuit for electronic equipment cooling, modular heat sink for control of remote packages, an HP temperature control for compartments, and air-cooled equipment racks. The philosophy, physical design details, and performance data are presented for each concept along with a comparison with the baseline design where applicable.

Tawil, M.↗

Signal conditioner for potentiometer type transducers

Low cost method is described for signal conditioning of pot-type transducers utilizing printed circuitry. Conditioner fits into standard rack, accommodates 56 channels, and can be operated by one attendant.

Armentrout, E. C.↗

CJ concept for advanced aircraft wiring

The techniques and hardware are described which were developed for facilitating the use of flexible flat conductor cable (FFCC) in commercial air transports. The system was designed as an evolutionary transition from the current round wire harnessing to the use of FFCC harnesses. The equipment discussed includes the pressure crimp barrel designed for terminating FFCC, reel-fed applicator, cable connectors and adaptors, and equipment racks.

Redslob, J.↗

Performance characteristics of zinc-rich coatings applied to carbon steel

A program was conducted to evaluate the performance of topcoated and untopcoated zinc-rich coatings. Sacrificial coatings of this type are required for protecting carbon steel structures from the aggressive KSC sea coast environment. A total of 59 commercially available zinc-rich coatings and 47 topcoated materials were exposed for an 18-month period. Test panels were placed in special racks placed approximately 30.5 m (100 feet) above the high tide line at the KSC Corrosion Test Site. Laboratory tests to determine the temperature resistance, abrasion resistance, and adhesion of the untopcoated zinc-rich coatings were also performed. It has been concluded that: (1) The inorganic types of zinc-rich coatings are far superior to the organic types in the KSC environment. (2) Organic zinc-rich coatings applied at 0.1 - 0.15 mm (4-6 mils) film thickness provide better corrosion protection than when applied at the manufacturers' recommended nominal film thickness of .08 mm (3 mils). (3) Topcoats are not necessary, or even desirable, when used in conjunction with zinc-rich coatings in the KSC environment. (4) Some types of inorganic zinc-rich coatings require an extended outdoor weathering period in order to obtain adequate mechanical properties. and (5) A properly formulated inorganic zinc-rich coating is not affected by a 24-hour thermal exposure to 400 C (752 F).

Paton, W. J.↗

A band clamp with a spring toggle lever

Clamp could have several applications, as it provides tolerance for both expansion and contraction. It might be useful with firemen's breathing apparatus and luggage racks and other freight-carrying equipment. Also, using same piece as handle and spring reduces production costs by reducing number of parts.

Simmonds, M.↗

Spacelab soft mockup comparative evaluation

An assessment of two proposed Spacelab configurations with diameters of 14 and 12 feet was conducted by using two inexpensive wooden mockups containing cardboard fixtures. Also examined was an alternate mounting arrangement for the 12-foot diameter configuration, taking advantage of conforming equipment racks to the cylinder walls. A volume comparison of the three configurations was made using a life sciences payload which is considered to be one of the more voluminous payloads. It was found that crew volume in the 12-foot baseline configuration appeared marginal for the life sciences payload, especially where crewmen were engaged in activities with competing demands. The 12-foot configurations of life sciences payloads offered little margin for stowage or equipment growth. Increased demands would necessitate longer module lengths. Similar results could be expected with other large volume payloads.

Watters, H.↗

Development of a uninterrupted power system: ac and dc to dc converter

This program covered the design, fabrication and testing of an advanced development model uninterrupted power system. The input and output requirements imposed on the power processor were specified such that the unit is electrically interchangeable with existing power systems used by the Federal Aviation Administration in installations which have a history of failure due to electrical transient conditions. Input power is from either of two single-phase ac power sources or batteries with electronic selection and transfer between power sources. Battery reconditioning is automatic when either ac source is present. The output power is rated at 84OW; the nominal output is 24V at 35A. Within the 84OW limit, the regulated output voltage is adjustable from 22V to 30Vdc. Protection against continuous overloading or short circuit is provided. The unit is packaged in a standard 19-inch rack mount configuration with 7-inch panel height. Controls are on the front panel with power input and output through connectors on the rear surface. Cooling is by free convection from fin areas located on the side and rear panels. The packaged unit weighs 52.8 lbs., which can be reduced significantly if a three-phase ac power source is used.

Cronin, D. L.↗

Airborne infrared astronomy telescope

Description of a 91.5-cm (36-in.) airborne infrared telescope installed in a C141A StarLifter as a national IR observatory. The telescope system is mounted in a specially constructed cavity located just ahead of the leading edge of the wing. All controls and ancillary systems are located in consoles and racks mounted aft of the telescope. The telescope is a conventional Cassegrain design which can be used either directly with the focal point behind the primary mirror or in a folded configuration by inserting a tertiary mirror following the secondary which folds the optical path through the support bearing into the aircraft cabin area. The telescope system is designed to operate at all ambient conditions from sea level to 15,200 m. The system is optimized for operation at ambient temperatures experienced at 13,000 to 15,000 m (220 K). The entire telescope assembly with the exception of noncritical covers and brackets is constructed of Invar-type material to minimize the effects of thermal distortions. Pointing accuracy and stability of the telescope with respect to the target are achieved through multiple stages of stabilization and vibration isolation equipment.

Cameron, R. M.↗