Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiance calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Improved passive microwave sounding of the atmosphere

The effort this year focused primarily on 118-GHz transmittance experiments. The data analyzed here was collected with the Microwave Temperature Sounder (MTS) radiometer package during the CAMEX deployment of 1993 with the aim of validating current models of atmospheric microwave absorption in the O2 bands near 54 and 118 GHz. Particular attention has been paid to data collected during four flights when the MTS scanned zenith while profiles of downwelling radiances were collected through ascents and descents. These radiances, in conjunction with radiosonde temperature data, permit the retrieval of band-averaged absorption profiles for each channel. The Millimeter-wave Propagation Model (MPM92) provides theoretical expressions for the absorption of microwaves by oxygen and water vapor and accounts for the interference of pressure-broadened spectral lines'. This model is a good fit to laboratory measurements at temperatures ranging from 279-327 K, but it has been suggested that extrapolation to the conditions of the atmospheric tropopause may result in underestimation of absorption by as much as 15 percent. Preliminary results of the analysis of MTS data appear to be in general agreement with the predictions of the MPM model to within the accuracy of the measurements, which through the coldest parts of the atmosphere ranges from less than plus or minus 5 percent in the most opaque channels to greater than plus or minus 10 percent in the most transparent channels. At those altitudes where each channel is most sensitive to changes in absorption, there is some indication that the modeled absorption may be biased low relative to the observations. Accurate instrument calibration provided challenges, particularly when observed radiances were as much as 260 K below the temperatures of the cold calibration load.

Staelin, D. H.↗

The Sixth SeaWiFS/SIMBIOS Intercalibration Round-Robin Experiment (SIRREX-6)

For the sixth Sea-Viewing Wide Field-of-View Sensor (SeaWiFS) Intercalibration Round-Robin Experiment (SIRREX-6), NASA personnel carried the same four Satlantic in-water radiometers to nine separate laboratories and calibrated them. Two of the sensors were seven-channel radiance heads and two were seven-channel irradiance heads. The calibration and data reduction procedures used at each site followed that laboratory's normal procedures. The reference lamps normally used for the calibration of these types of instruments by the various laboratories were also used for this experiment. NASA personnel processed the data to produce calibration parameters from the various laboratories

Riley, Thomas↗

Radiometric Calibration Assessment of Commercial High Spatial Resolution Multispectral Image Products

Radiometric calibration of commercial imaging satellite products is required to ensure that science and application communities can better understand their properties. Inaccurate radiometric calibrations can lead to erroneous decisions and invalid conclusions and can limit intercomparisons with other systems. To address this calibration need, satellite at-sensor radiance values were compared to those estimated by each independent team member to determine the sensor's radiometric accuracy. The combined results of this evaluation provide the user community with an independent assessment of these commercially available high spatial resolution sensors' absolute calibration values.

Holekamp, Kara↗

Radiometric Characterization of the IKONOS, QuickBird, and OrbView-3 Sensors

Radiometric calibration of commercial imaging satellite products is required to ensure that science and application communities can better understand their properties. Inaccurate radiometric calibrations can lead to erroneous decisions and invalid conclusions and can limit intercomparisons with other systems. To address this calibration need, satellite at-sensor radiance values were compared to those estimated by each independent team member to determine the sensor's radiometric accuracy. The combined results of this evaluation provide the user community with an independent assessment of these commercially available high spatial resolution sensors' absolute calibration values.

Holekamp, Kara↗

Calibration of the Airborne Visible/Infrared Imaging Spectrometer in the Laboratory

Imaging spectrometry data must be spectrally, radiometrically and geometrically calibrated in order to: 1) derive physical parameters from measured spectral radiance, 2) compare data acquired from different regions and at different times, 3) compare and analyze the imaging spectrometry data with data acquired from other calibrated sensors, and 4) compare and analyze data with results from computer models. The calibration of AVIRIS data is the process by which laboratory characterization data are applied to raw instrument data (digitized number versus spectral channels) to produce quantitative spectra (radiance versus wavelength) for each image pixel in units of spectral radiance. The AVIRIS sensor and calibration process are described by Vane and the application of the calibration data to the raw digital data is described by Green. This calibration process is validated for in-flight performance of the sensor using a rigorous ground-truth campaign. This workshop paper reviews the laboratory characterization data set that is used in the AVIRIS calibration process. The laboratory measurements used to acquire the calibration data are divided into three classes: 1) spectral calibration, 2) radiometric calibration, and 3) spatial calibration.

Green Robert O.↗

Detector Based Calibration of a Portable Imaging Spectrometer for CLARREO Pathfinder Mission

The Climate Absolute Refractivity and Reflectance Observatory (CLARREO) Pathfinder (CPF) mission is being developed to demonstrate SI-traceable retrievals of reflectance at unprecedented accuracies for global satellite observations. An Independent Calibration of the CPF sensor using the Goddard Laser for Absolute Measurement of Radiance (GLAMR) is planned to allow validation of CPF accuracies. GLAMR is a detector-based calibration system relies on a set of NIST-calibrated transfer radiometers to assess the spectral radiance from the GLAMR sphere source to better than 0.3 % (k=2). The current work describes the calibration of the Solar, Lunar Absolute Reflectance Imaging Spectroradiometer (SOLARIS) that was originally developed as a calibration demonstration system for the CLARREO mission and is now being used to assess the independent calibration being developed for CPF. The methodology for the radiometric calibration of SOLARIS is presented as well as results from the GLAMR-based calibration of SOLARIS. The portability of SOLARIS makes it capable of collecting field measurements of earth scenes and direct solar and lunar irradiance similar to those expected during the on-orbit operation of the CPF sensor. Results of SOLARIS field measurements are presented. The use of SOLARIS in this effort also allows the testing protocols for GLAMR to be improved and the field measurements by SOLARIS build confidence in the error budget for GLAMR calibrations. Results are compared to accepted solar irradiance models to demonstrate accuracy values giving confidence in the error budget for the CLARREO reflectance retrieval.

Aytac, Yigit↗

Analysis of Aeronet Extended Wavelength Retrievals of Aerosol Absorption Parameters Including 380 NM and 500 NM for Detection of Brown Carbon in Biomass Burning and Iron Oxides in Desert Dust

To investigate near UV aerosol absorbers, such as iron in mineral dust and brown carbon from biomass burning, AERONET spectral imaginary refractive index and size distributions retrievals were performed with the input of additional wavelength data. This includes adding both measured spectral AOD and sky radiances at 380 nm and 500 nm to the four channels (440, 675, 870 and 1020 nm) that are used in the standard retrieval data product. The vector radiative transfer code in the AERONET Version 3 retrievals enabled more accurate computations in the ultraviolet region (380 nm). Calibration of the 380 nm channel radiances was done by the vicarious method since the integrating sphere radiance source that is used for all other wavelengths does not produce sufficient energy at 380 nm. Spectral single scattering albedo, imaginary refractive indices and aerosol size distributions from these six wavelength retrievals are compared to the standard four wavelength retrieval values.

Aerosol↗

MTF Analysis of LANDSAT-4 Thematic Mapper

A research program to measure the LANDSAT 4 Thematic Mapper (TM) modulation transfer function (MTF) is described. Measurement of a satellite sensor's MTF requires the use of a calibrated ground target, i.e., the spatial radiance distribution of the target must be known to a resolution at least four to five times greater than that of the system under test. A small reflective mirror or a dark light linear pattern such as line or edge, and relatively high resolution underflight imagery are used to calibrate the target. A technique that utilizes an analytical model for the scene spatial frequency power spectrum will be investigated as an alternative to calibration of the scene. The test sites and analysis techniques are also described.

Schowengerdt, R.↗

Comparison of modelled and empirical atmospheric propagation data

The radiometric integrity of TM thermal infrared channel data was evaluated and monitored to develop improved radiometric preprocessing calibration techniques for removal of atmospheric effects. Modelled atmospheric transmittance and path radiance were compared with empirical values derived from aircraft underflight data. Aircraft thermal infrared imagery and calibration data were available on two dates as were corresponding atmospheric radiosonde data. The radiosonde data were used as input to the LOWTRAN 5A code which was modified to output atmospheric path radiance in addition to transmittance. The aircraft data were calibrated and used to generate analogous measurements. These data indicate that there is a tendancy for the LOWTRAN model to underestimate atmospheric path radiance and transmittance as compared to empirical data. A plot of transmittance versus altitude for both LOWTRAN and empirical data is presented.

Schott, J. R.↗

Comparison of modelled and empirical atmospheric propagation data

The radiometric integrity of TM thermal infrared channel data was evaluated and monitored to develop improved radiometric preprocessing calibration techniques for removal of atmospheric effects. Modelled atmospheric transmittance and path radiance were compared with empirical values derived from aircraft underflight data. Aircraft thermal infrared imagery and calibration data were available on two dates as were corresponding atmospheric radiosonde data. The radiosonde data were used as input to the LOWTRAN 5A code which was modified to output atmospheric path radiance in addition to transmittance. The aircraft data were calibrated and used to generate analogous measurements. These data indicate that there is a tendency for the LOWTRAN model to underestimate atmospheric path radiance and transmittance as compared to empirical data. A plot of transmittance versus altitude for both LOWTRAN and empirical data is presented.

Schott, J. R.↗

Terra MODIS Sees Solar Eclipses: Analysis of Reflective Solar Band Response at Multiple Radiance Levels

The MODIS imaging spectroradiometer instruments on-board NASA's Terra and Aqua satellites have 20 reflective solar bands (RSB) covering a wavelength range from 400 to 2200 nm. Radiance is calculated from processing raw signals with background, temperature, and electronic contamination corrected. Measured gain is calibrated with a fully Sunlit solar diffuser (SD) at a stable radiance level, considering a slowly changing SD reflectance degradation. These measurements provide time-dependent gain adjustment factors, and the calibration assumes a linear response for each band and detector. Hence, an analysis of the dependence on different radiance levels is warranted. The MODIS design has no mechanism for varying radiance levels, except for an attenuator screen. However, it has been in static configuration for Terra since mid-2003. An external source of radiance attenuation can be utilized during solar eclipse events, while maintaining high stability and accuracy of solar calibration standards. Due to its long mission lifetime, Terra has seen several Sun-Moon near-conjunction events when it coincides with the orbit path where the SD is directly illuminated. As of August 2020, we have identified 7 viable partial solar eclipses in the Terra mission data. We will discuss several results of our study, including comparison of measured SD signal to predicted radiance reduction based on a solar disk radiance model; nominal and outlier behavior as a function of bands, detectors, and mirror-sides; and comparison with other data sets. Our main conclusion from this study is that there is no notable correlation of detector-dependent trend with radiance level for most RSB bands.

Terra↗

Radiometric Calibration of the Earth Observing System's Imaging Sensors

The work on the grant was mainly directed towards developing new, accurate, redundant methods for the in-flight, absolute radiometric calibration of satellite multispectral imaging systems and refining the accuracy of methods already in use. Initially the work was in preparation for the calibration of MODIS and HIRIS (before the development of that sensor was canceled), with the realization it would be applicable to most imaging multi- or hyper-spectral sensors provided their spatial or spectral resolutions were not too coarse. The work on the grant involved three different ground-based, in-flight calibration methods reflectance-based radiance-based and diffuse-to-global irradiance ratio used with the reflectance-based method. This continuing research had the dual advantage of: (1) developing several independent methods to create the redundancy that is essential for the identification and hopefully the elimination of systematic errors; and (2) refining the measurement techniques and algorithms that can be used not only for improving calibration accuracy but also for the reverse process of retrieving ground reflectances from calibrated remote-sensing data. The grant also provided the support necessary for us to embark on other projects such as the ratioing radiometer approach to on-board calibration (this has been further developed by SBRS as the 'solar diffuser stability monitor' and is incorporated into the most important on-board calibration system for MODIS)- another example of the work, which was a spin-off from the grant funding, was a study of solar diffuser materials. Journal citations, titles and abstracts of publications authored by faculty, staff, and students are also attached.

Slater, Philip N.↗

Uncertainty in Calibration, Detection and Estimation of Metal Concentrations in Engine Plumes Using OPAD

Improvements in uncertainties in the values of radiant intensity (I) can be accomplished mainly by improvements in the calibration process and in minimizing the difference between the background and engine plume radiance. For engine tests in which the plume is extremely bright, the difference in luminance between the calibration lamp and the engine plume radiance can be so large as to cause relatively large uncertainties in the values of R. This is due to the small aperture necessary on the receiving optics to avoid saturating the instrument. However, this is not a problem with the SSME engine since the liquid oxygen/hydrogen combustion is not as bright as some other fuels. Applying the instrumentation to other type engine tests may require a much brighter calibration lamp.

Hopkins, Randall C.↗

GIFTS SM EDU Radiometric and Spectral Calibrations

The Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) Sensor Module (SM) Engineering Demonstration Unit (EDU) is a high resolution spectral imager designed to measure infrared (IR) radiance using a Fourier transform spectrometer (FTS). The GIFTS instrument gathers measurements across the long-wave IR (LWIR), short/mid-wave IR (SMWIR), and visible spectral bands. The raw interferogram measurements are radiometrically and spectrally calibrated to produce radiance spectra, which are further processed to obtain atmospheric profiles via retrieval algorithms. This paper describes the processing algorithms involved in the calibration. The calibration procedures can be subdivided into three categories: the pre-calibration stage, the calibration stage, and finally, the post-calibration stage. Detailed derivations for each stage are presented in this paper.

Tian, J.↗

Impacts of the Angular Dependence of the Solar Diffuser BRDF Degradation Factor on the SNPP VIIRS Reflective Solar Band On-Orbit Radiometric Calibration

Using an onboard sunlit solar diffuser (SD) as the primary radiance source, the visible infrared imaging radiometer suite (VIIRS) on the Suomi National Polar-orbiting Partnership satellite regularly performs radiometric calibration of its reflective solar bands (RSBs). The SD bidirectional reflectance distribution function (BRDF) value decreases over time. A numerical degradation factor is used to quantify the degradation and is determined by an onboard SD stability monitor (SDSM), which observes the sun and the sunlit SD at almost the same time. We had shown previously that the BRDF degradation factor was angle-dependent. Consequently, due to that the SDSM and the RSB view the SD at very different angles relative to both the solar and the SD surface normal vectors, directly applying the BRDF degradation factor determined by the SDSM to the VIIRS RSB calibration can result in large systematic errors. We develop a phenomenological model to calculate the BRDF degradation factor for the RSB SD view from the degradation factor for the SDSM SD view. Using the yearly undulations observed in the VIIRS detector gains for the M1-M4 bands calculated with the SD BRDF degradation factor for the SDSM SD view and the difference between the VIIRS detector gains calculated from the SD and the lunar observations, we obtain the model parameter values and thus establish the relation between the BRDF degradation factors for the RSB and the SDSM SD view directions.

Lei, Ning↗

Diurnal Cycles in SST: Coupled Data Assimilation and Future Observational Requirements

Most operational centers are developing coupled (atmosphere-ocean) data assimilation systems as an alternative to uncoupled counterparts (atmosphere- or ocean-only). The Sea Surface Temperature (SST) is one of the key variables that tightly connects the atmosphere and ocean states and also air-sea fluxes. However, current prototype coupled data assimilation systems rely on external (L4) gridded SST or along-track (L3 or L2) SST retrievals as observed data or relaxation field. But in reality, SST are measurements are available from sparse in-situ network of ships, moorings, and buoys; all of them combined together are far less than those from satellites. However, satellites do not directly measure temperature, and inferring SST from satellite measured radiances requires a radiative transfer model, its calibration and also bias correction.The NASA Global Modeling and Assimilation Office (GMAO) is developing a coupled data assimilation system which assimilates SST directly from the raw observations, i.e., satellite radiances and in-situ observations. The methodology to directly assimilate radiances for SST became operational in Jan, 2017 in the GMAO's near-real time Weather Analysis and Prediction System. There were many modifications to the GMAO system in order to implement SST assimilation, most of which generally improved the predictability of the system. In order to maintain and further improve this system, we advocate for the availability of a microwave satellite radiometer in future beyond the currently operational GPM- GMI and AMSR-2 missions. For improved modeling of the near-surface temperature, salinity and mixing processes, we suggest adding more than one temperature sensor and salinity sensors to the drifting buoy network.

Akella, Santha↗

Cross-Calibration of AQUA-MODIS and NPP-VIIRS Reflective Solar Bands for a Seamless Record of CERES Cloud and Flux Properties

The CERES measured shortwave and longwave fluxes rely on the cloud properties derived using the coincident observations from the accompanying high-resolution MODIS and VIIRS imagers. The calibration consistency is required between MODIS and VIIRS radiances to ensure that the CERES provided cloud property retrievals are temporally consistent. This paper presents multiple approaches of cross-calibrating the spectrally comparable reflective solar bands (RSB) of Aqua-MODIS and NPP- VIIRS, and estimates the radiometric biases for individual band pair. The inter-comparison is performed between the Aqua-MODIS collection 6.1 level 1B and NPP-VIIRS Land PEATE V1 datasets. Radiometric biases up to 3% were estimated bet een the MODIS and VIIRS radiances for visible bands.

Bhatt, Rajendra↗

Response Versus Scan-Angle Corrections for MODIS Reflective Solar Bands Using Deep Convective Clouds

The absolute radiometric calibration of the reflective solar bands (RSBs) of Aqua- and Terra-MODIS is performed using on-board calibrators. A solar diffuser (SD) panel along with a solar diffuser stability monitor (SDSM) system, which tracks the performance of the SD over time, provides the absolute reference for calibrating the MODIS sensors. MODIS also views the moon and deep space through its space view (SV) port for lunar-based calibration and computing the zero input radiance, respectively. The MODIS instrument views the Earths surface through a two-sided scan mirror, whose reflectance is a function of angle of incidence (AOI) and is described by response versus scan-angle (RVS). The RVS for both MODIS instruments was characterized prior to launch. MODIS also views the SD and the moon at two different assigned RVS positions. There is sufficient evidence that the RVS is changing on orbit over time and as a function of wavelength. The SD and lunar observation scans can only track the RVS variation at two RVS positions. Consequently, the MODIS Characterization Support Team (MCST) developed enhanced approaches that supplement the onboard calibrator measurements with responses from pseudo-invariant desert sites. This approach has been implemented in Level 1B (L1B) Collection 6 (C6) for selected short-wavelength bands. This paper presents an alternative approach of characterizing the mirror RVS to derive the time-dependent RVS correction factors for MODIS RSBs using tropical deep convective cloud (DCC) targets. An initial assessment of the DCC response from Aqua-MODIS band 1 C6 data indicates evidence of RVS artifacts, which are not uniform across the scans and are more prevalent in the left side Earth-view scans.

Bhatt, Rajendra↗