Performance Assessment of the NOAA-20 VIIRS RSB Using Deep Convective Clouds

The Visible Infrared Imaging Radiometer Suite (VIIRS) onboard the NOAA-20 (N20) satellite was launched on November 18, 2017. The N20 VIIRS reflective solar bands (RSBs) are calibrated on-orbit using a solar diffuser. An accurate on-orbit calibration is crucial to the high-quality downstream products facilitating atmosphere, ocean and land applications. In this study, the stability of the Level 1B (L1B) reflectance product is investigated using measurements over deep convective clouds (DCCs) for M-bands M1-M5, M7-M11, and I-bands I1-I3. The methodologies developed previously for Terra and Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) sensors and Suomi National Polar-orbiting Partnership (SNPP) VIIRS are extended and applied to the N20 RSB to derive DCC-based trends. The Collection 2 L1B data produced by NASA Land Science Investigator-led Processing Systems (SIPS) is used to evaluate the performance of the N20 VIIRS RSB calibration. At nadir, the reflectance trends for M1, M5, M8-M11, and I3 are insignificant compared to their corresponding variations (STDs) except for bands M2-M4, M7, and I1-I2, whose trends are larger than or equivalent to their STDs. The reflectance is relatively stable compared to their STDs for all the study RSBs at six aggregation zones across the entire scan angle range. Also discussed in this paper are the detector-to-detector differences and half-angle mirror side differences using the DCCs. Future applications using DCCs, which include an intercomparison with SNPP VIIRS, are also discussed.

N20 VIIRS↗

Reflectance characteristics of reference materials used in lidar hard target calibration

Lidar hard target calibration is discussed, emphasizing the transfer target methodology. Characteristics of example calibratrion target surfaces are described in light of four reflectance mechanisms, specular, diffuse, retroreflection, and off-specular reflectance. The ideal transfer target is one which can be described as entirely diffusely reflecting, i.e., Lambertian. Correction for retroreflection is required when using the flowers of a sulfur transfer target at CO2 laser wavelengths. Corrections for specular and retroreflection for the integrating sphere are negligible; however, the off-specular reflectance of rough metal surfaces used in the integrating spheres is only qualitatively compared with the diffuse reflectance of flowers of sulfur.

Haner, David A.↗

Reflective Solar Band Striping Mitigation Method for the GOES-R Series Advanced Baseline Imager Using Special Scans

The large focal plane arrays used in the new generation of the Geostationary Operational Environmental Satellites (GOES) advanced baseline imager (ABI) introduce new calibration challenges compared with the heritage GOES imagers. The increased number of detectors allows for increased spatial, spectral, and temporal performance, but as a trade-off, it has an increased risk of image striping. We detail the development of a new postlaunch relative calibration capability for ABI reflective solar bands that utilizes ABI special scans to generate a set of relative gains that can be applied to improve image quality and reduce image striping. Results demonstrate that the method reduces image striping in the ABI solar reflective bands over varying scene content and time, both diurnally and over an extended period. This methodology ensures a calibration strategy that is consistent with heritage approaches yet adapts to the new postlaunch validation challenges presented by the new class of operational imagers in the GOES-R series. The developed approach is ready for operational use, as needed, and can be easily implemented into operations to support the operational production of geostationary imagery of the Earth.

Monica Cook↗

Absolute radiometric calibration of the NOAA AVHRR sensors

Three different approaches to the absolute radiometric calibration of the two reflective channels of the NOAA AVHRR sensors are presented. The first method involves ground and atmospheric measurements and reference to another calibrated satellite sensor. The second involves ground and atmospheric measurements with no reference to another sensor, while the third method involves no ground and atmospheric measurements but reference to another sensor. NOAA-9 and NOAA-10 AVHRR data sets are presented.

Teillet, P. M.↗

MODIS Solar Diffuser On-Orbit Degradation Characterization Using Improved SDSM Screen Modeling

The Solar Diffuser (SD) is used for the MODIS reflective solar bands (RSB) calibration. An on-board Solar Diffuser Stability Monitor (SDSM) tracks the degradation of its on-orbit bi-directional reflectance factor (BRF). To best match the SDSM detector signals from its Sun view and SD view, a fixed attenuation screen is placed in its Sun view path, where the responses show ripples up to 10%, much larger than design expectation. Algorithms have been developed since the mission beginning to mitigate the impacts of these ripples. In recent years, a look-up-table (LUT) based approach has been implemented to account for these ripples. The LUT modeling of the elevation and azimuth angles is constructed from the detector 9 (D9) of SDSM observations in the MODIS early mission. The response of other detectors is normalized to D9 to reduce the ripples observed in the sun-view data. The accuracy of all detectors degradation estimation depends on how well the D9 approximated. After multiple years of operation (Terra: 16 years; Aqua: 14 years), degradation behavior of all detectors can be monitored by their own. This paper revisits the LUT modeling and proposes a dynamic scheme to build a LUT independently for each detector. Further refinement in the Sun view screen characterization will be highlighted to ensure the degradation estimation accuracy. Results of both Terra and Aqua SD on-orbit degradation are derived from the improved modeling and curve fitting strategy.

Chen, H.↗

A Portable Ground-Based Atmospheric Monitoring System (PGAMS) for the Calibration and Validation of Atmospheric Correction Algorithms Applied to Aircraft and Satellite Images

Detecting changes in the Earth's environment using satellite images of ocean and land surfaces must take into account atmospheric effects. As a result, major programs are underway to develop algorithms for image retrieval of atmospheric aerosol properties and atmospheric correction. However, because of the temporal and spatial variability of atmospheric transmittance it is very difficult to model atmospheric effects and implement models in an operational mode. For this reason, simultaneous in situ ground measurements of atmospheric optical properties are vital to the development of accurate atmospheric correction techniques. Presented in this paper is a spectroradiometer system that provides an optimized set of surface measurements for the calibration and validation of atmospheric correction algorithms. The Portable Ground-based Atmospheric Monitoring System (PGAMS) obtains a comprehensive series of in situ irradiance, radiance, and reflectance measurements for the calibration of atmospheric correction algorithms applied to multispectral. and hyperspectral images. The observations include: total downwelling irradiance, diffuse sky irradiance, direct solar irradiance, path radiance in the direction of the north celestial pole, path radiance in the direction of the overflying satellite, almucantar scans of path radiance, full sky radiance maps, and surface reflectance. Each of these parameters are recorded over a wavelength range from 350 to 1050 nm in 512 channels. The system is fast, with the potential to acquire the complete set of observations in only 8 to 10 minutes depending on the selected spatial resolution of the sky path radiance measurements

Schiller, Stephen↗

Development of a High-Fidelity CLARREO Pathfinder Simulator

CLARREO Pathfinder is a hyperspectral instrument designed to resolve reflectance of solar radiation from Earth in the wavelength range of 350 nm to 2300 nm with an uncertainty of 0.3% (k=2) or less. Its success will demonstrate CLARREO’s ability to provide on-orbit SI-Traceable calibration of measured spectral reflectance with an advanced accuracy. The CLARREO pathfinder simulator has been developed to generate high-fidelity inter-calibration event data products that can be used for pre-launch inter-calibration algorithm study. A high-fidelity simulation for CLARREO inter-calibration events includes computationally intensive radiative transfer calculations for observations within each individual collocation footprint. A principal component based radiative transfer model is incorporated in the simulator to enable an ultra-fast forward simulation, ensuring a low latency data processing for month- to year-long intercalibration events. This paper introduces the design and development of the CLARREO pathfinder simulator and some of its applications for inter-calibration matching error evaluation.

Wan Wu↗

VIIRS Reflective Solar Band Radiometric and Stability Evaluation Using Deep Convective Clouds

This work takes advantage of the stable distribution of deep convective cloud (DCC) reflectance measurements to assess the calibration stability and detector difference in Visible Infrared Imaging Radiometer Suite (VIIRS) reflective bands. VIIRS Sensor Data Records (SDRs) from February 2012 to June 2015 are utilized to analyze the long-term trending, detector difference, and half angle mirror (HAM) side difference. VIIRS has two thermal emissive bands with coverage crossing 11 microns for DCC pixel identification. The comparison of the results of these two processing bands is one of the indicators of analysis reliability. The long-term stability analysis shows downward trends (up to approximately 0.4 per year) for the visible and near-infrared bands and upward trends (up to 0.5per year) for the short- and mid-wave infrared bands. The detector difference for each band is calculated as the difference relative to the average reflectance overall detectors. Except for the slightly greater than 1 difference in the two bands at 1610 nm, the detector difference is less than1 for other solar reflective bands. The detector differences show increasing trends for some short-wave bands with center wavelengths from 400 to 600 nm and remain unchanged for the bands with longer center wavelengths. The HAM side difference is insignificant and stable. Those short-wave bands from 400 to 600 nm also have relatively larger HAM side difference, up to 0.25.Comparing the striped images from SDR and the smooth images after the correction validates the analyses of detector difference and HAM side difference. These analyses are very helpful for VIIRS calibration improvement and thus enhance product quality

VIIRS↗

A study to explore the use of orbital remote sensing to determine native arid plant distribution

The author has identified the following significant results. A theory has been developed of a method for determining the reflectivities of natural areas from ERTS-1 data. This method requires the following measurements: (1) ground truth reflectivity data from two different calibration areas; (2) radiance data from ERTS-1 MSS imagery for the same two calibration areas; and (3) radiance data from ERTS-1 MSS imagery for the area(s) in which reflectivity is to be determined. The method takes into account sun angle effects and atmospheric effects on the radiance seen by the space sensor. If certain assumptions are made, the ground truth data collection need not be simultaneous with the ERTS-1 overflight. The method allows the calculation of a conversion factor for converting ERTS-1 MSS radiance measurements of a given overflight to reflectivity values. This conversion factor can be used to determine the reflectivity of any area in the general vicinity of the calibration areas which has a relatively similar overlying atmosphere. This method, or some modification of it, may be useful in ERTS investigations which require the determination of spectral signatures of areas from spacecraft data.

Mcginnies, W. G.↗

NASA's CLARREO Pathfinder Mission: The Reflected Solar’s First SITSat

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder mission will take reflected solar (RS) highly accurate measurements needed to monitor Earth’s climate and will be the first RS SI-traceable Satellite Sensor (SITSat). The mission includes a RS spectrometer that will be installed on the International Space Station (ISS) and take measurements for at least one year. CLARREO Pathfinder (CPF) will use on-orbit calibration to achieve an unprecedented high accuracy with SI-traceability and the inter-calibration of other on-orbit instruments. The spectrometer is based on the HyperSpectral Imager for Climate Science (HySICS) instrument developed by the University of Colorado/Laboratory for Atmospheric and Space Physics of Boulder, CO, USA. HySICS is being designed to have a radiometric uncertainty of 0.3% (1-sigma), a five to ten times improvement over existing spaceflight RS instruments. High accuracy SI-traceable measurements such as these are critical to develop long-term climate-quality data sets. Additionally, by measuring spectral reflectance with high accuracy the CPF instrument will serve as an on-orbit intercalibration radiometric reference for operational Earth-viewing sensors, such as the Clouds and Earth’s Radiant Energy System (CERES) broadband shortwave instrument and the Visible/Infrared Imaging Radiometer Suite (VIIRS). Two-axis pointing, a spectral range from 350 nm to 2300 nm, and a spectral resolution ≤6 nm enable CPF to provide nearly coincident temporal, spatial, angular, and spectral matching of intercalibration targets, with sampling sufficient to reduce random errors. The intercalibration method will refine knowledge of target sensors’ effective offsets, gain, non-linearity, spectral response, and polarization sensitivity (as is relevant). Calibrated reflectance and reflected radiance spectra will be distributed to the scientific community through a NASA Distributed Active Archive Center (DAAC). We will present an overview of the CLARREO Pathfinder mission, its anticipated impact on monitoring climate variability, and the novel CPF direct intercalibration approach.

climate↗

Ground-reference site and on-board methods for sensor absolute calibration in the 0.4 to 2.5 micron range

The absolute radiometric calibration uncertainty requirement for several multispectral imaging sensors to be used in the Earth Observing System (EOS) program is +/- 2 percent (one sigma) with respect to the sun. Proposed in-flight absolute calibration methods are reviewed that have this uncertainty as their goal. In particular two methods are described as are recent improvements to them that concern reflectance- and radiance-based calibration using a carefully selected ground reference site. The magnitudes of the error sources are listed. A ratioing radiometer approach to monitoring the reflectance of a solar diffuser used for onboard calibration is discussed.

Slater, P. N.↗

An absolute photometric system at 10 and 20 microns

Two new direct calibrations at 10 and 20 microns are presented in which terrestrial flux standards are referred to infrared standard stars. These measurements give both good agreement and higher accuracy when compared with previous direct calibrations. As a result, the absolute calibrations at 10 and 20 microns have now been determined with accuracies of 3 and 8 percent, respectively. A variety of absolute calibrations based on extrapolation of stellar spectra from the visible to 10 microns are reviewed. Current atmospheric models of A-type stars underestimate their fluxes by about 10 percent at 10 microns, whereas models of solar-type stars agree well with the direct calibrations. The calibration at 20 microns can probably be determined to about 5 percent by extrapolation from the more accurate result at 10 microns. The photometric system at 10 and 20 microns is updated to reflect the new absolute calibration, to base its zero point directly on the colors of A0 stars, and to improve the accuracy in the comparison of the standard stars.

Rieke, G. H.↗

Evaluation of Detector-to-Detector and Mirror Side Differences for Terra MODIS Reflective Solar Bands Using Simultaneous MISR Observations

The Moderate Resolution Imaging Spectroradiometer (MODIS) is one of the five Earth-observing instruments on-board the National Aeronautics and Space Administration (NASA) Earth-Observing System(EOS) Terra spacecraft, launched in December 1999. It has 36 spectral bands with wavelengths ranging from 0.41 to 14.4 mm and collects data at three nadir spatial resolutions: 0.25 km for 2 bands with 40 detectors each, 0.5 km for 5 bands with 20 detectors each and 1 km for the remaining 29 bands with 10 detectors each. MODIS bands are located on four separate focal plane assemblies (FPAs) according to their spectral wavelengths and aligned in the cross-track direction. Detectors of each spectral band are aligned in the along-track direction. MODIS makes observations using a two-sided paddle-wheel scan mirror. Its on-board calibrators (OBCs) for the reflective solar bands (RSBs) include a solar diffuser (SD), a solar diffuser stability monitor (SDSM) and a spectral-radiometric calibration assembly (SRCA). Calibration is performed for each band, detector, sub-sample (for sub-kilometer resolution bands) and mirror side. In this study, a ratio approach is applied to MODIS observed Earth scene reflectances to track the detector-to-detector and mirror side differences. Simultaneous observed reflectances from the Multi-angle Imaging Spectroradiometer (MISR), also onboard the Terra spacecraft, are used with MODIS observed reflectances in this ratio approach for four closely matched spectral bands. Results show that the detector-to-detector difference between two adjacent detectors within each spectral band is typically less than 0.2% and, depending on the wavelengths, the maximum difference among all detectors varies from 0.5% to 0.8%. The mirror side differences are found to be very small for all bands except for band 3 at 0.44 mm. This is the band with the shortest wavelength among the selected matching bands, showing a time-dependent increase for the mirror side difference. This study is part of the effort by the MODIS Characterization Support Team (MCST) in order to track the RSB on-orbit performance for MODIS collection 5 data products. To support MCST efforts for future data re-processing, this analysis will be extended to include more spectral bands and temporal coverage.

Wu, Aisheng↗

Sensor On-orbit Calibration and Characterization Using Spacecraft Maneuvers

Spacecraft flight operations often require activities that involve different kinds of maneuvers for orbital adjustments (pitch, yaw, and roll). Different maneuvers, when properly planned and scheduled, can also be applied to support and/or to perform on-board sensor calibration and characterization. This paper uses MODIS (Moderate Resolution Imaging Spectroradiometer) as an example to illustrate applications of spacecraft maneuvers for Earth-observing sensors on-orbit calibration and characterization. MODIS is one of the key instruments for NASA's Earth Observing System (EOS) currently operated on-board the EOS Terra and Aqua spacecraft launched in December 1999 and May 2002, respectively. Since their launch, both Terra and Aqua spacecraft have made a number of maneuvers, specially the yaw and roll maneuvers, to support the MODIS on-orbit calibration and characterization. For both Terra and Aqua MODIS, near-monthly spacecraft roll maneuvers are executed for lunar observations. These maneuvers are carefully scheduled so that the lunar phase angles are nearly identical for each sensor's lunar observations. The lunar observations are used to track MODIS reflective solar bands (RSB) calibration stability and to inter-compare Terra and Aqua MODIS RSB calibration consistency. To date, two sets of yaw maneuvers (each consists of two series of 8 consecutive yaws) by the Terra spacecraft and one set by the Aqua spacecraft have been performed to validate MODIS solar diffuser (SD) bi-directional reflectance factor (BRF) and to derive SD screen transmission. Terra spacecraft pitch maneuvers, first made on March 26, 2003 and the second on April 14, 2003 (with the Moon in the spacecraft nadir view), have been applied to characterize MODIS thermal emissive bands (TEB) response versus scan angle (RVS). This is particularly important since the pre-launch TEB RSV measurements made by the sensor vendor were not successful. Terra MODIS TEB RVS obtained from pitch maneuvers have been used in the current LIB calibration algorithm. Lunq observations from pitch maneuvers also provided information to cross-calibrate MODIS with other sensors (MISR and ASTER) on the same platform. We will provide a summary of MODIS maneuver activities and their applications for MODIS calibration and characterization. The results and lessons learned discussed in this paper from MODIS maneuver activities will provide useful insights into future spacecraft and sensor operation.

Xiong, X.↗

Signals of Opportunity Airborne Demonstrator (SoOP-AD)

In the second year of the SoOp-AD project, a brassboard analog section has been completed, along with working designs for the digital section and an antenna compatible with the NASA Langley B-200 or UC-12B aircraft. Resource requirements for the digital section FPGA are being finalized. One technical challenge at P-band is that the low transmitted data rate makes isolation of the direct and reflected signals using path delay, the conventional practice for GNSS reflectometry, difficult. Any retrieval of surface reflectivity from these measurements must account for the combination of direct and reflected signal in both the sky-view and Earth-view antennas. We have approached this challenge on several fronts; First, through null steering of the antenna. Second, through the formulation of an empirical calibration function for the reflectivity; and finally through estimating the direct and reflected signal powers as independent states in a Kalman filter. In addition to the direct-reflected interference from the same transmitter, there is also the possibility of interference due to transmissions, in adjacent bands, from other satellites in the constellation. Ground-based repeaters are also present in the S-band spectrum. Digital filters are being designed to isolate these repeaters, using simulations to verify the magnitude of their effect on the reflectivity and soil moisture retrievals. Other contributions to the error budget include the uncertainty in aircraft altitude, and the antenna pattern.

Radar↗

Calibration of AIS Data Using Ground-based Spectral Reflectance Measurements

Present methods of correcting airborne imaging spectrometer (AIS) data for instrumental and atmospheric effects include the flat- or curved-field correction and a deviation-from-the-average adjustment performed on a line-by-line basis throughout the image. Both methods eliminate the atmospheric absorptions, but remove the possibility of studying the atmosphere for its own sake, or of using the atmospheric information present as a possible basis for theoretical modeling. The method discussed here relies on use of ground-based measurements of the surface spectral reflectance in comparison with scanner data to fix in a least-squares sense parameters in a simplified model of the atmosphere on a wavelength-by-wavelength basis. The model parameters (for optically thin conditions) are interpretable in terms of optical depth and scattering phase function, and thus, in principle, provide an approximate description of the atmosphere as a homogeneous body intervening between the sensor and the ground.

Conel, J. E.↗

An Overview of Lunar Calibration and Characterization for the EOS Terra and Aqua MODIS

The Moon can be used as a stable source for Earth-observing sensors on-orbit radiometric and spatial stability monitoring in the VIS and NIR spectral regions. It can also serve as a calibration transfer vehicle among multiple sensors. Nearly identical copies of the Moderate Resolution Imaging Spectroradiometer (MODE) have been operating on-board the NASA's Earth Observing System (EOS) Terra and Aqua satellites since their launches in December 1999 and May 2002, respectively. Terra and Aqua MODIS each make observations in 36 spectral bands covering the spectral range from 0.41 to 14.5 microns and are calibrated on-orbit by a set of on-board calibrations (OBCs) including: 1) a solar diffuser (SD), 2) a solar diffuser stability monitor (SDSM), 3) a blackbody (BB), and 4) a spectro-radiometric calibration assembly (SRCA). In addition to fully utilizing the OBCs, the Moon has been used extensively by both Terra and Aqua MODIS to support their on-orbit calibration and characterization. A 4 This paper provides an overview of applications of lunar calibration and characterization from the MODIS perspective, including monitoring radiometric calibration stability for the reflective solar bands (RSBs), tracking changes of the sensors response versus scan-angle (RVS), examining the sensors spatial performance , and characterizing optical leaks and electronic crosstalk among different spectral bands and detectors. On-orbit calibration consistency between the two MODIS instruments is also addressed. Based on the existing on-orbit time series of the Terra and Aqua MODIS lunar observations, the radiometric difference between the two sensors is less than +/-1% for the RSBs. This method provides a powerful means of performing calibration comparisons among Earth-observing sensors and assures consistent data and science products for the long-term studies of climate and environmental changes.

Xiong, X.↗