Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample complexity analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Exploring 2D X-ray diffraction phase fraction analysis with convolutional neural networks: Insights from kinematic-diffraction simulations

Abstract Deep-learning models are effective for analyzing the complex information in 2D X-ray diffraction (XRD) patterns. Accurately collecting parameters of the material sample is crucial during model training, significantly impacting model performance. In this study, we employ a kinematic-diffraction simulator to generate simulated 2D XRD patterns for Ti–6Al–4V alloy, allowing precise control of sample parameters. These simulated patterns are used to train convolutional neural networks, predicting $$\upbeta$$ β -phase volume fractions. The training data set consists exclusively of 2D XRD patterns with pure $$\upalpha$$ α - or pure $$\upbeta$$ β -phase, while the testing set incorporates patterns with intermediate phase volume fraction. In particular, we investigate how the architectures of the model influence prediction reliability and computational performance. Experimental results reveal that, with appropriate training, the convolutional neural network accurately detects intermediate phase volume fractions even trained with only pure-phase patterns, achieving a mean square error accuracy of $$9.4 \times 10^{-4}$$ 9.4 × 10 - 4 . Graphical abstract

Yue, Weiqi↗

Altersbestimmung an thermalen Tiefenwässern im Oberjura des Molassebeckens mittels Krypton-Isotopen

81 Kr (half-life 229,000 years) is an ideal tracer for old groundwater. The Upper Jurassic rock in the deep Molasse Basin is an outstanding geothermal groundwater reservoir (with temperatures up to 140 °C). However, due to the complex groundwater evolution (ion and isotope exchange, gas flux, etc.), comprehensive hydrogeological studies completed to date, including 14 C–DIC and He isotopes, could not resolve the recharge dynamics and residence times. Nine geothermal wells were therefore sampled for 81 Kr/ 85 Kr employing the laser-based atom trap tracer analysis technique (ATTA). In the western and central basin, the results reveal predominant groundwater recharge during the last glacial period with one sample influenced by infiltration during the earlier glacial period. Recharge signatures and 81 Kr-model-ages fit very well to subglacial recharge with cross-formational flow through the sedimentary cover (600 to >3000 m deep). In the eastern basin, the results point to the Cromerian complex, indicating a slower flow system with less influence from recharge during glacial periods.

54 ENVIRONMENTAL SCIENCES↗

Local atomic structure and Ni nanophase segregation in Zn 1-x Ni x S thin films

Here, the local atomic structure of Zn 1-x Ni x S thin films was investigated using X-ray absorption spectroscopy. The films were grown using RF-sputtering at atomic concentrations x = 0.00, x = 0.04, x = 0.08 and x = 0.14. X-ray diffraction shows that the lattice parameter contracts with increasing Ni concentration, consistent with the smaller atomic radii of Ni compared to that one of Zn. Optical absorption reveals a reduction of the bandgap as Ni concentration increases, except for sample x = 0.14 where a complex behavior is observed. Results from X-ray absorption near edge structure (XANES) spectroscopy indicate a shift in the valence state of Ni for the x = 0.14 sample. The analysis of the extended X-ray absorption fine structure (EXAFS) spectra indicate a contraction of ~0.7 Å in the Ni–S bond distance when compared to the Zn–S bond length, which generates local lattice distortions and an increment of the static disorder as the Ni concentration increases. The EXAFS results for sample x = 0.14 show the presence of a Zn 1-x Ni x S phase and a nanoscopic metallic Ni phase with domain sizes below the diffraction limit. These results reveal that the local atomic structure differs in a significant manner from the average crystalline structure, implying its importance for the determination of the electronic properties of this material.

36 MATERIALS SCIENCE↗

Understanding the Structure and Dynamics of Complex Biomembrane Interactions by Neutron Scattering Techniques

The membrane is one of the key structural materials of biology at the cellular level. Composed predominantly of a bilayer of lipids with embedded and bound proteins, it defines the boundaries of the cell and many organelles essential to life and therefore is involved in almost all biological processes. Membrane-specific interactions, such as drug binding to a membrane receptor or the interactions of an antimicrobial compound with the lipid matrix of a pathogen membrane, are of interest across the scientific disciplines. Herein we present a review, aimed at nonexperts, of the major neutron scattering techniques used in membrane studies: small-angle neutron scattering, neutron membrane diffraction, neutron reflectometry, quasielastic neutron scattering, and neutron spin echo. Neutron scattering techniques are well suited to studying biological membranes. The nondestructive nature of cold neutrons means that samples can be measured for long periods without fear of beam damage from ultraviolet, electron, or X-ray radiation, and neutron beams are highly penetrating, thus offering flexibility in samples and sample environments. Most important is the strong difference in neutron scattering lengths between the two most abundant forms of hydrogen, protium and deuterium. Changing the relative amounts of protium/deuterium in a sample allows the production of a series of neutron scattering data sets, enabling the observation of differing components within complex membrane architectures. This approach can be as simple as using the naturally occurring neutron contrast between different biomolecules to study components in a complex by changing the solution H 2 O/D 2 O ratio or as complex as selectively labeling individual components with hydrogen isotopes. This review presents an overview of each experimental technique with the neutron instrument configuration, related sample preparation and sample environment, and data analysis, highlighted by a special emphasis on using prominent neutron contrast to understand structure and dynamics. This review gives researchers a practical introduction to the often enigmatic suite of neutron beamlines, thereby lowering the barrier to taking advantage of these large-facility techniques to achieve new understandings of membranes and their interactions with other molecules.

59 BASIC BIOLOGICAL SCIENCES↗

Multimodal imaging of oil-in-water bilgewater emulsion and biofilms

Bilgewater emulsions, consisting of oil and surfactant mixtures in water, affect many aquatic species. Thus development of methods and techniques to treat or mitigate the formation and undesired consequences of shipboard emulsions are urgently needed. This work presents new results of the evolution of the bilgewaer chemical and physical properties using in situ imaging. A Navy O/W emulsion consisting of three oils and a detergent mixture was used as the synthetic bilgewater model [1, 2]. Synthetic oil-in-water (O/W) emulsion droplets were seled in a vacuum compatible microfluidic sample holder and imaged using a suite of tools including scanning electron microscopy (SEM), time-of-flight secondary ion mass spectrometry (ToF-SIMS), confocal laser scanning microscopy, and optical microscopy, highlighting the advantage of multiscale analysis and its applications in waste reduction and treatment in the environment. The transferrable and vacuum compatible microfluidic interface, System for Analysis at the Liquid Vacuum Interface (SALVI), was used in this study. SALVI enabled surface analysis of liquids and liquid-solid interactions using ToF-SIMS and SEM [3, 4]. Its detection window is an aperture of 2 ?m in diameter open to vacuum, permitting direct detection of the liquid surface. Liquid is withheld by surface tension within the aperture. The interface is composed of a silicon nitride membrane and polydimethylsiloxane microchannel [3, 4]. A variety of samples including complex liquid mixtures, ionic liquids, single mammalian cells, live biofilms, and solid-electrolyte interface have been analyzed using in situ imaging [5, 6]. The feasibility of using SALVI for in situ SEM imaging of nanoparticles and colloids in liquid was recently demonstrated [7]. This paper shows new findings of multimodal imaging and analysis of synthesized emulsion particles in water. Figure 1 depicts a schematic of multimodal in situ imaging of bilgewater emulsion using SEM and ToF-SIMS. Furthermore, we study the interactions of microbes and bilgewater emulsion. Microbes play an important role in the ocean. We hypothesize that microbes release organics that can act as surfactants that affect bilgewater formation or weakening. We present the first systematic study of emulsions and biofilms and investigate the effects of biofilms on bilgewater emulsions. Pseudomonas was selected as a model strain. Biofilms were cultured in a microchannel to allow culture [8]. Once a thick layer of biofilms was formed, the medium solution was changed to a mixture consisting of 50 % bilgewater emulsion. Dispersed biofilms were collected at 24 hrs. and 48 hrs. after emulsions were introduced into the channel. Bilgewater emulsions, biofilms, and mixtures of bilgewater emulsions and biofilms were analyzed using multiple in situ and ex situ techniques as described earlier. Our findings indicate that biofilms change the chemical makeup of the emulsion surface compositions and emulsion droplet size distribution, confirming the hypothesis that extracellular polymeric substance (EPS) related components released from biofilms can function as surfactants and change the oil-in-water interfaces.

bilgewater, multimodal imaging, biofilms↗

Extension of Complex Refractive Index Measurements to the Near-Infrared for Liquids: Methodology and Uncertainty Analysis

Optical identification of liquid droplets, aerosols, or thin films is important for many applications. While reference spectra are sometimes available for such measurements, they are not always applicable to the observed spectrum or the given sample morphology. Reference spectra for many forms can be modeled, however, if the n/k vectors (real and imaginary refractive indices) are available. In previous work we have reported protocols to determine the n/k vectors for dozens of liquids, primarily in the mid-infrared (MIR) spectral range from 7500 to 400 cm –1 . In this work we extend the spectral range into the near-infrared (NIR) region, demonstrating a method to measure and merge the data sets to create composite n/k data ranging from 10 000 to 400 cm –1 (1.0 to 25 µm) with absorbance fidelity spanning over four orders of magnitude, and vastly improved signal-to-noise in the NIR. The precision of the composite data is evaluated for three different liquids, focusing primarily on the steps for converting the raw absorbance spectra to k values. The variability in both MIR and NIR data as well as in the final n/k vectors is also investigated for several liquids. For typical liquids, the overall variability (reported as 2σ) in the final n and k-vectors is determined to be ∼0.4% and 3%, respectively. Finally, the derived n/k data are used to calculate absorbance spectra for aerosol droplets, showing marginal variability due to the typical measurement errors in the final n/k vectors.

47 OTHER INSTRUMENTATION↗

Titan In-situ Resource Utilization (ISRU) Sample Return (TISR)

Titan is unique in the outer solar system in that it is the only moon with a thick atmosphere, and the only body in the solar system outside the Earth with liquid seas on its surface. The Titanian oceans, however, are seas of liquid hydrocarbons, and the rocks on the surface are solid water ice. Like other icy Moons of the outer solar system, beneath the ice crust, Titan also has a subsurface ocean. Rodriguez et al. refer to it as the “world with two oceans”, an organic-rich body with interior-surface-atmosphere interactions that are comparable in complexity to the Earth. [1] Titan is scientifically fascinating in many ways [2], [3], [4]. The Compass Team will emphasize just one here: Titan is a high priority target for astrobiology [4] [5] [6] [7] [8] [9] [10] [11]. It is a world with a surface and atmosphere rich in the complex organic compounds known as tholins. A detailed understanding of the nature of these complex compounds will require an analysis using a full laboratory on Earth. Because of its value to understanding the organic compounds of the outer solar system which may be the primordial building-blocks of life, return of samples from Titan to laboratories on Earth will be the primary goal of this mission. While this would give unprecedented science return, returning even a small sample from Titan using conventional technology would be tremendously difficult. Saturn is almost a billion miles from the Earth, about thirteen times farther than Mars. A return mission to Saturn requires such a large total-mission ∆V that, with conventional technology, the mass ratios required are prohibitive. Such a sample return would truly be “mission incredible.” But to date, a sample return mission from so distant a target has been assumed to be, not merely incredible, but mission impossible. The Compass Team has proposed [2] [12] that by manufacturing the propellant for the return to Earth using the resources available on Titan, such a mission becomes possible. The task of this report is to show that it is reasonable with credible space technology.

Titan↗

Quantum algorithm to simulate Lindblad master equations

We present a quantum algorithm for simulating a family of Markovian master equations that can be realized through a probabilistic application of unitary channels and state preparation. Our approach employs a second-order product formula for the Lindblad master equation, achieved by decomposing the dynamics into dissipative and Hamiltonian components and replacing the dissipative segments with randomly compiled, easily implementable elements. The sampling approach eliminates the need for ancillary qubits to simulate the dissipation process and reduces the gate complexity in terms of the number of jump operators. We provide a rigorous performance analysis of the algorithm. We also extend the algorithm to time-dependent Lindblad equations, generalize the family of Markovian master equations it can be applied to, and explore applications beyond the Markovian noise model. A new error bound, in terms of the diamond norm, for second-order product formulas for time-dependent Liouvillians is provided that might be of independent interest. Published by the American Physical Society 2025

Borras, Evan (ORCID:000900017709037X)↗

DOE JGI Metagenome Workflow

The DOE Joint Genome Institute (JGI) Metagenome Workflow performs metagenome data processing, including assembly; structural, functional, and taxonomic annotation; and binning of metagenomic data sets that are subsequently included into the Integrated Microbial Genomes and Microbiomes (IMG/M) (I.-M. A. Chen, K. Chu, K. Palaniappan, A. Ratner, et al., Nucleic Acids Res, 49:D751–D763, 2021, https://doi.org/10.1093/nar/gkaa939) comparative analysis system and provided for download via the JGI data portal (https://genome.jgi.doe.gov/portal/). This workflow scales to run on thousands of metagenome samples per year, which can vary by the complexity of microbial communities and sequencing depth. Here, we describe the different tools, databases, and parameters used at different steps of the workflow to help with the interpretation of metagenome data available in IMG and to enable researchers to apply this workflow to their own data. We use 20 publicly available sediment metagenomes to illustrate the computing requirements for the different steps and highlight the typical results of data processing. The workflow modules for read filtering and metagenome assembly are available as a workflow description language (WDL) file (https://code.jgi.doe.gov/BFoster/jgi_meta_wdl). The workflow modules for annotation and binning are provided as a service to the user community at https://img.jgi.doe.gov/submit and require filling out the project and associated metadata descriptions in the Genomes OnLine Database (GOLD) (S. Mukherjee, D. Stamatis, J. Bertsch, G. Ovchinnikova, et al., Nucleic Acids Res, 49:D723–D733, 2021, https://doi.org/10.1093/nar/gkaa983).

59 BASIC BIOLOGICAL SCIENCES↗

Nb3Sn Coating of Twin Axis Cavity for SRF Applications

The twin axis cavity with two identical accelerating beams has been proposed for Energy recovery linac (ERL) applications. Nb3Sn is a superconducting material with a higher critical temperature and a higher critical field as compared to Nb, which promises a lower operating cost due to higher quality factors. Two niobium twin axis cavities fabricated at JLab and were proposed to be coated with Nb3Sn. Due to their more complex geometry, the typical coating process used for basic elliptical cavities needs to be improved to coat these cavities. This devel-opment advances the current coating system at JLab for coating complex cavities. Two twin axis cavities were coated recently for the first time. This contribution dis-cusses initial results from coating of twin axis cavities, RF testing and witness sample analysis with an overview of the current challenges towards high performance Nb3Sn coated twin axis cavities.

Tiskumara, J.↗

Nb₃Sn Coating of Twin Axis Cavity for SRF Applications

The twin axis cavity with two identical accelerating beams has been proposed for energy recovery linac (ERL) applications. Nb₃Sn is a superconducting material with a higher critical temperature and a higher critical field as compared to Nb, which promises a lower operating cost due to higher quality factors. Two niobium twin axis cavities were fabricated at JLab and were proposed to be coated with Nb₃Sn. Due to their more complex geometry, the typical coating process used for basic elliptical cavi-ties needs to be improved to coat these cavities. This development advances the current coating system at JLab for coating complex cavities. Two twin axis cavities were coated recently for the first time. This contribution dis-cusses initial results from coating of twin axis cavities, RF testing and witness sample analysis with an overview of the current challenges towards high performance Nb₃Sn coated twin axis cavities.

43 PARTICLE ACCELERATORS↗

Proteomic Analysis of Exosomes for Discovery of Protein Biomarkers for Prostate and Bladder Cancer

Extracellular vesicles (EVs) are released by nearly all cell types as part of normal cell physiology, transporting biological cargo, including nucleic acids and proteins, across the cell membrane. In pathological states such as cancer, EV-derived cargo may mirror the altered state of the cell of origin. Exosomes are the smaller, 50–150 nanometer-sized EVs released from fusion of multivesicular endosomes with the plasma membrane. Exosomes play important roles in cell-cell communication and participate in multiple cancer processes, including invasion and metastasis. Therefore, proteomic analysis of exosomes is a promising approach to discover potential cancer biomarkers, even though it is still at an early stage. Herein, we critically review the advances in exosome isolation methods and their compatibility with mass spectrometry (MS)-based proteomic analysis, as well as studies of exosomes in pathogenesis and progression of prostate and bladder cancer, two common urologic cancers whose incidence rates continue to rise annually. As urological tumors, both urine and blood samples are feasible for noninvasive or minimally invasive analysis. A better understanding of the biological cargo and functions of exosomes via high-throughput proteomics will help provide new insights into complex alterations in cancer and provide potential therapeutic targets and personalized treatment for patients.

60 APPLIED LIFE SCIENCES↗

Skylab M518 multipurpose furnace convection analysis

An analysis was performed of the convection which existed on ground tests and during skylab processing of two experiments: vapor growth of IV-VI compounds growth of spherical crystals. A parallel analysis was also performed on Skylab experiment indium antimonide crystals because indium antimonide (InSb) was used and a free surface existed in the tellurium-doped Skylab III sample. In addition, brief analyses were also performed of the microsegregation in germanium experiment because the Skylab crystals indicated turbulent convection effects. Simple dimensional analysis calculations and a more accurate, but complex, convection computer model, were used in the analysis.

Bourgeois, S. V.↗

Characterization of low thermal conductivity PAN-based carbon fibers

The microstructure and surface chemistry of eight low thermal conductivity (LTC) PAN-based carbon fibers were determined and compared with PAN-based fibers heat treated to higher temperatures. Based on wide-angle x ray diffraction, the LTC PAN fibers all appear to have a similar turbostratic structure with large 002 d-spacings, small crystallite sizes, and moderate preferred orientation. Limited small-angle x ray scattering (SAXS) results indicate that, with the exception of LTC fibers made by BASF, the LTC fibers do not have well developed pores. Transmission electron microscopy shows that the texture of the two LTC PAN-based fibers studied (Amoco T350/23X and /25X) consists of multiple sets of parallel, wavy, bent layers that interweave with each other forming a complex three dimensional network oriented randomly around the fiber axis. X ray photoelectron spectroscopy (XPS) analysis finds correlations between heat treated temperatures and the surface composition chemistry of the carbon fiber samples.

Katzman, Howard A.↗

Leveraging Machine Learning Capabilities for the Characterization of Irradiated Uranium: A Case Study of Analysis Methods for Nuclear Safeguards and Nuclear Forensics

Nondestructively determining the initial enrichment of irradiated uranium is a complex and laborious multivariable problem due to the presence of fission products. This work demonstrates the capabilities of machine learning to analyze gamma-ray spectral data to determine initial enrichment without knowledge of the decay time of the sample. The approach developed is agnostic to the particular scenario and is applicable to a wide variety of applications in nuclear forensics and nuclear safeguards. We irradiated 5 mg uranium standard reference materials at discrete enrichment values ranging from 0.02% to 97% 235 U (weight percent) in UT Austin’s Nuclear Engineering Teaching Laboratory TRIGA Mark II 1.1 MW research reactor, allowed each to decay for 8 hours, and then measured each sample via gamma-ray spectrometry for 50 hours post-irradiation yielding 1,400 individual gamma-ray spectra discretized into 8,192 energy bins. We then trained decision trees models to analyze individual gamma-ray spectra and estimate the associated initial enrichment without knowledge of the time since end of irradiation. We evaluated the performance of the models with a reserved test set not used for training or calibrating the model. A decision tree model constructed with this procedure achieved a mean absolute error in initial enrichment determination of 2.3% (weight percent 235 U). Next, we implemented a principal component analysis pre-processing routine of the gamma-ray spectrometry data to reduce the dimensionality of the dataset from 8,192 channels in the spectrum to 10 principal components while retaining over 99% of the inherent variance in the data. Decision tree models constructed with these data demonstrated decreased mean absolute error in enrichment determination, reduced computational time, and decreased complexity. A single decision tree model constructed with this procedure achieved a mean absolute error in initial enrichment determination of 0.05% (weight percent 235 U). Furthermore, we analyzed these models with learning curves to ensure that overfitting did not occur. The capabilities provided by these models can be naturally extended to other application-focused measurements in the fields of nuclear safeguards, nuclear forensics, and nuclear non-proliferation.

Drescher, Adam↗

A Novel Biomedical Device Utilizing Light Emitting Nano-Structures

This paper will discuss the development of a novel biomedical detection device that will be used to detect microorganisms with the use of infrared fluorochrome polymers attached to antibodies in fluids such as water. The fluorochrome polymers emit light in the near inferred region (NIR), approximately 805 nm, when excited by an NIR laser at 778 nm. The device could remarkably change the way laboratory testing is done today. The testing process is usually performed on a time scale of days while our device will be able to detect microorganisms in minutes. This type of time efficient analysis is ideal for use aboard the International Space Station and the Space Shuttle (ISS/SS) and has many useful commercial applications, for instance at a water treatment plant and food processing plants. With more research and experimentation the testing might also one day be used to detect bacteria and viruses in complex fluids such as blood, which would revolutionize blood analysis as it is performed today. My contribution to the project has been to develop a process which will allow an antibody/fluorescent dye pair to be conjugated to a specific bacteria or virus and than to to be separated from a sample body of water for detection. The antibody being used in this experiment is anti beta galactosidase and its complement enzyme is beta galactosidase, a non harmful derivative of E. Coli. The anti beta galactosidase has been conjugated to the fluorochrome polymer, IRDye800, which emits at approximately 806 nm. The dye when excited by the NIR laser emits a signal which is detected by a spectrometer and then is read by state of the art computer software. The state-of-the-art process includes incubating the anti beta galactosidase and beta galactosidase in a phosphate buffer solution in a test tube, allowing the antibody to bind to specific sites on the enzyme. After the antibody is bound to the enzyme, it is centrifuged in specific filters that will allow free antibody to wash away and leave the antibody-enzyme complexes on top in solution for testing and analysis. This solution is pipetted into a cuvette, a special plastic test tube, which will then be excited by the laser. The signal read will tell US that an antibody is present and since it is bound to the enzyme, that the bacteria is also present.

Varaljay, Vanessa A.↗

Compound-Specific Isotope Analysis of Amino Acids for Stardust-Returned Samples

Significant portions of the early Earth's prebiotic organic inventory , including amino acids, could have been delivered to the Earth's sur face by comets and their fragments. Analysis of comets via spectrosc opic observations has identified many organic molecules, including me thane, ethane, arnmonia, cyanic acid, formaldehyde, formamide, acetal ehyde, acetonitrile, and methanol. Reactions between these identifie d molecules could allow the formation of more complex organics such a s amino acids. Isotopic analysis could reveal whether an extraterrest rial signature is present in the Stardust-exposed amines and amino ac ids. Although bulk isotopic analysis would be dominated by the EACA contaminant's terrestrial signature, compoundspecific isotope analysi s (CSIA) could determine the signature of each of the other individua l amines. Here, we report on progress made towards CSIA of the amino acids glycine and EACA in Stardustreturned samples.

Cook, Jamie↗

Sample Preparation for 3D Characterization of Irradiated Fuel

Thorough characterization of nuclear fuel is essential when striving to understand its microstructural evolution in response to varying irradiation conditions. A detailed understanding of the microstructural evolution of irradiated fuel can be useful when predicting the fuel’s response to off-normal conditions and related phenomena such as high burnup fuel fragmentation (HBFF) and fission gas release. This sort of characterization and the study of complex phenomena like HBFF that are related to fuel performance are an important part of the US Department of Energy Office of Nuclear Energy’s Advanced Fuels Campaign (AFC). Multiple characterization techniques are commonly used to perform post-irradiation examination (PIE) analysis on an irradiated fuel sample, but many of these techniques are limited to the 2D surface analysis of the fuel pellet. Although there is a lot of useful information to be gained by analyzing the fuel pellet surface, a 2D analysis provides only an approximation of the nature of the material’s features, such as porosity and grain structure. Therefore, it is critical to analyze the 3D structure of the material, as materials exist and respond to conditions in all three dimensions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗