Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Variability in NGC 3201 Giant Stars and Its Impact on Their Spectroscopic [Fe/H] Determination

We present the analysis of 34 light curves in V and I of 17 giant stars in the globular cluster NGC 3201 to check if such stars are variable and if their variability has some kind of impact on the iron abundance as obtained from spectroscopic measurements. First, we computed the generalized Lomb–Scargle and phase dispersion minimization periodograms of the sample to check if the stars were variables. In this way, seven stars of the sample were found to be nonvariable, two stars are considered as possible variables, and eight stars were found to be variable, with periods ranging from 0.0881 ± 0.0001 to 0.5418 ± 0.0027 days. According to the literature, the variables have distinct values of [Fe I/H]: the three most metal-rich stars are in the red giant branch (RGB) stage, one has [Fe I/H] = −1.37 dex, while the other two have [Fe I/H] = −1.31 dex. The two most metal-poor variables have [Fe I/H] = −1.61 dex and [Fe I/H] = −1.62 dex, and are AGB stars; the remaining variables have [Fe I/H] = −1.44, −1.48, and −1.50 dex, the first two being RGB stars while the last is an AGB star. On the other hand, stars that appear to be nonvariable have −1.56 ≤ [Fe I/H] ≤ −1.40. We conclude that variability somehow affects the spectroscopic determination of the iron content of giant stars in NGC 3201, increasing the iron spread of the cluster. If variability is not taken into account, this spread could be incorrectly interpreted as due to an intrinsic iron spread affecting the stars of the cluster.

36 MATERIALS SCIENCE↗

High-resolution in situ electrochemical NMR with interdigitated electrodes

A system for carrying out electrochemical nuclear magnetic resonance spectroscopy (EC-NMR) is disclosed, along with methods of manufacturing the EC-NMR system, and methods of using the EC-NMR system to monitor electrochemical reactions. The system comprises interdigitated electrodes arranged in a cylindrically symmetric manner. The system allows for nuclear magnetic resonance spectroscopy to be carried out on a sample during electrolysis with minimal effect to its sensitivity.

Tong, YuYe J.↗

Geant4 simulation for a study of a possible use of carbon ions pencil beam for the treatment of ocular melanomas with the active scanning system at CNAO Centre

The aim of this work is to validate the Geant4 application reproducing the CNAO (National Centre for Oncological Hadrontherapy) beamline and to study of a possible use of carbon ion pencil beams for the treatment of ocular melanomas at the CNAO Centre. The promising aspect of carbon ions radiotherapy for the treatment of this disease lies in its superior relative radiobiological effectiveness (RBE). The Monte Carlo Geant4 toolkit is used to simulate the complete CNAO extraction beamline, with the active and passive components along it. A human eye modeled detector, including a realistic target tumor volume, is used as target. Cross check with previous studies at CNAO using protons allows comparisons on possible benefits on using such a technique with respect to proton beams. Before the eye-detector irradiation a validation of the Geant4 simulation with CNAO experimental data is carried out with both carbon ions and protons. Important beam parameters such as the transverse FWHM and scanned radiation field 's uniformity are tested within the simulation and compared with experimental measurements at CNAO Centre. The physical processes involved in secondary particles generation by carbon ions and protons in the eye-detector are reproduced to take into account the additional dose to the primary beam given to irradiated eye's tissues. A study of beam shaping is carried out to produce a uniform 3D dose distribution (shaped on the tumor) by the use of a spread out Bragg peak. The eye-detector is then irradiated through a two dimensional transverse beam scan at different depths. In the use case the eye-detector is rotated of an angle of 40 deg. in the vertical direction, in order to mis-align the tumor from healthy tissues in front of it. The treatment uniformity on the tumor in the eye-detector is tested. For a more quantitative description of the deposited dose in the eye-detector and for the evaluation of the ratio between the dose deposited in the tumor and the other eye components, proton and carbon DVHs (Dose Volume Histograms) are compared. A high statistics simulated sample is used to minimize statistical errors. In the simulation a new particle generation method is developed in order to reproduce the experimental treatment plan by importing the DICOM RT-PLAN file, which contains all the information on the irradiation geometries and sequences (treatment plan parameters). Conclusions Even further validations must be done, the good results so far obtained by this work point out and confirm the possibility of using carbon ions delivered with active scanning beams to treat the ocular melanoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Weighted greedy-optimal design of computer experiments for kernel-based and Gaussian process model emulation and calibration

This article is concerned with the approximation of high-dimensional functions by kernel-based methods. Motivated by uncertainty quantification, which often necessitates the construction of approximations that are accurate with respect to a probability density function of random variables, we aim at minimizing the approximation error with respect to a weighted $L^p$-norm. We present a greedy procedure for designing computer experiments based upon a weighted modification of the pivoted Cholesky factorization. The method successively generates nested samples with the goal of minimizing error in regions of high probability. Numerical experiments validate that this new importance sampling strategy is superior to other sampling approaches, especially when used with non-product probability density functions. We also show how to use the proposed algorithm to efficiently generate surrogates for inferring unknown model parameters from data.

97 MATHEMATICS AND COMPUTING↗

Uncertainties in model-independent extractions of amplitudes from complete experiments

A new generation of over-complete experiments is underway, with the goal of performing a high precision extraction of pseudoscalar meson photo-production amplitudes. Such experimentally determined amplitudes can be used both as a test to validate models and as a starting point for an analytic continuation in the complex plane to search for poles. Of crucial importance for both is the level of uncertainty in the extracted multipoles. We have probed these uncertainties by analyses of pseudo-data for KLambda photoproduction, first for the set of 8 observables that have been published for the K{sup +} Lambda channel and then for pseudo-data on a complete set of 16 observables with the uncertainties expected from analyses of ongoing CLAS experiments. In fitting multipoles, we have used a combined Monte Carlo sampling of the amplitude space, with gradient minimization, and have found a shallow X{sup 2} valley pitted with a large number of local minima. This results in bands of solutions that are experimentally indistinguishable. All ongoing experiments will measure observables with limited statistics. We have found a dependence on the particular random choice of values of Gaussian distributed pseudo-data, due to the presence of multiple local minima. This results in actual uncertainties for reconstructed multipoles that are often considerable larger than those returned by gradient minimization routines such as Minuit which find a single local minimum. As intuitively expected, this additional level of uncertainty decreases as larger numbers of observables are included.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Oxidation Penetration in Nuclear Graphite

Study results are presented for seven grades of graphite where 21 cylindrical samples were oxidized to a nominal level of mass loss. Low mass loss samples exhibited ~3% oxidative mass loss, intermediate ~8%, and high ~11%. Flat sample surfaces were covered during oxidation to minimize oxidation penetration at the top and bottom of each sample. Oxidized samples had their diameters reduced stepwise in 1 mm or 2 mm increments. Residual samples were weighed, geometric dimensions were recorded, and Archimedes measurements were taken at each step. Preliminary comparative graphical analysis is presented to illustrate the resultant density gradients observed. Raw tabular data are also provided.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ion beam production with sub-milligram samples of material from an ECR source for AMS

Current accelerator mass spectrometry experiments at the Argonne Tandem Linac Accelerator System facility at Argonne National Laboratory push us to improve the ion source performance with a large number of samples and a need to minimize cross contamination. These experiments can require the creation of ion beams from as little as a few micrograms of material. These low concentration samples push the limit of our current efficiency and stability capabilities of the electron cyclotron resonance ion source. A combination of laser ablation and sputtering techniques coupled with a newly modified multi-sample changer has been used to meet this demand. We will discuss performance, stability, and consumption rates as well as planned improvements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Post-irradiation examination of UN-Mo-W fuels for space nuclear propulsion

The National Aeronautics and Space Administration's return to space nuclear propulsion stems from the need for a more efficient method of space travel. Nuclear thermal propulsion systems have been shown to be two times more efficient than chemical propulsion. NASA's Sirius program was created to fabricate and test fuels for space nuclear propulsion, specifically to determine their performance under prototypical startup conditions. The Sirius project featured 4 test capsules, Sirius-1 featured uranium nitride fuel dispersed in a matrix of tungsten and rhenium, while Sirius-2A, -2B, and -3 featured uranium nitride-molybdenum-tungsten fuel (UN-Mo-W). This study discusses the Sirius-2A and -2B irradiation experiments at the Idaho National Laboratory, specifically their performance under irradiation at the Transient Reactor Test Facility. It was found that the fuel samples overall did not exhibit significant cracking, though the Sirius-2A fuel did have one large crack on the surface of the fuel. There was minimal hydrogen absorption in the samples, though it is unknown if the absorption occurred during irradiation or during fabrication. Mechanical testing indicated that the UN fuel demonstrated ceramic behavior as expected, and the Mo/W matrix demonstrated linear elastic behavior to failure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Near-isothermal furnace for in situ and real time X-ray radiography solidification experiments

In this paper, we present a newly developed near-isothermal X-ray transparent furnace for in situ imaging of solidification processes in thin metallic samples. We show that the furnace is ideally suited to study equiaxed microstructure evolution and grain interaction. To observe the growth dynamics of equiaxed dendritic structures, a minimal temperature gradient across the sample is required. A uniform thermal profile inside a circular sample is achieved by positioning the sample in the center of a cylindrical furnace body surrounded by a circular heater arrangement. Performance tests with the hypo-eutectic Al-15wt.%Cu and the near-eutectic Al-33wt.%Cu alloys validate the near-isothermal character of the sample environment. Controlled cooling rates of less than 0.5 K min{sup −1} up to 10 K min{sup −1} can be achieved in a temperature range of 720 K–1220 K. Integrated in our rotatable laboratory X-ray facility, X-RISE, the furnace provides a large field of view of 10.5 mm in diameter and a high spatial resolution of ∼4 μm. With the here presented furnace, equiaxed dendrite growth models can be rigorously tested against experiments on metal alloys by, e.g., enabling dendrite growth velocities to be determined as a function of undercooling or solutal fields in front of the growing dendrite to be measured.

36 MATERIALS SCIENCE↗

The crystal structure of a biogenic aragonite from the nacre of an ammonite shell

The crystal structure of a biogenic aragonite from the nacre of an ammonite shell was obtained using synchrotron high-resolution powder X-ray diffraction (HRPXRD) data and Rietveld structure refinement. The well-preserved ammonite sample is from Alberta, Canada, and is from the Cretaceous period. The aragonite structure was refined in space group Pmcn, Z = 4, and the cell parameters obtained are a = 4.96265(2), b = 7.97016(4), c = 5.74474(3) {angstrom}, and V = 227.222(2) {angstrom}{sup 3}. The chemical analyses indicate a formula of [Ca{sub 0.995}Sr{sub 0.004}Ba{sub 0.001}]{Sigma} = 1.0(CO{sub 3}). The average <Ca-O> and <C-O> distances are 2.5281(3) and 1.2871(6) {angstrom}, respectively, and the average <O-C-O> angle is 119.94(8){sup o}. The CO{sub 3} groups are non-planar. Based on crystal-structure data for biogenic and non-biogenic aragonite samples, aragonite from ammonite nacre has minimal structural distortions and is very similar to non-biogenic aragonite, in particular, a sample from Spain.

58 GEOSCIENCES↗

BY-110 Headspace Sampling Comparison Test: Volume 1

The Hanford Tank Operations Contractor, Washington River Protection Solutions, conducted comparison tests of two Hanford Waste tank vapor sampling systems to determine the relative differences in quantifying Chemicals of Potential Concern (COPC) while sampling the same waste tank. The systems are the traditional in situ, inline headspace sampling (HS) method and the recently developed slipstream sampling unit for testing respirator chemical cartridges known as the cartridge test (CT) rig. The comparison test was performed to determine if results obtained using the CT rig are similar to results obtained using the traditional HS method. Using the CT rig would provide efficiencies in headspace vapors sampling such as applying ALARA principles, minimizing worker entries to the tank farms, and eliminating the physical strain of manually lowering the headspace sampling bundles into the waste tanks. Six sampling events were conducted during January and February 2018 to collect headspace vapor samples from Hanford tank BY-110 with the two systems. Pacific Northwest National Laboratory was tasked with conducting an analysis of the analytical results to assess the comparability of the sampling methods and make recommendations on future testing or deployment of the CT method.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

BY-110 Headspace Sampling Comparison Test: Volume 2: Raw Data

The Hanford Tank Operations Contractor, Washington River Protection Solutions, conducted comparison tests of two Hanford Waste tank vapor sampling systems to determine the relative differences in quantifying Chemicals of Potential Concern (COPC) while sampling the same waste tank. The systems are the traditional in situ, inline headspace sampling (HS) method and the recently developed slipstream sampling unit for testing respirator chemical cartridges known as the cartridge test (CT) rig. The comparison test was performed to determine if results obtained using the CT rig are similar to results obtained using the traditional HS method. Using the CT rig would provide efficiencies in headspace vapors sampling such as applying ALARA principles, minimizing worker entries to the tank farms, and eliminating the physical strain of manually lowering the headspace sampling bundles into the waste tanks. Six sampling events were conducted during January and February 2018 to collect headspace vapor samples from Hanford tank BY-110 with the two systems. Pacific Northwest National Laboratory was tasked with conducting an analysis of the analytical results to assess the comparability of the sampling methods and make recommendations on future testing or deployment of the CT method.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A comparison of cost and quality of three methods for estimating density for wild pig (Sus scrofa)

A critical element in efective wildlife management is monitoring the status of wildlife populations; however, resources to monitor wildlife populations are typically limited. We compared cost efectiveness of three common population estimation methods (i.e. non-invasive DNA sampling, camera sampling, and sampling from trapping) by applying them to wild pigs (Sus scrofa) across three habitats in South Carolina, U.S.A where they are invasive. We used mark-recapture analyses for fecal DNA sampling data, spatially-explicit capture-recapture analyses for camera sampling data, and a removal analysis for removal sampling from trap data. Density estimates were similar across methods. Camera sampling was the least expensive, but had large variances. Fecal DNA sampling was the most expensive, although this technique generally performed well. We examined how reductions in efort by method related to increases in relative bias or imprecision. For removal sampling, the largest cost savings while maintaining unbiased density estimates was from reducing the number of traps. For fecal DNA sampling, a reduction in efort only minimally reduced costs due to the need for increased lab replicates while maintaining high quality estimates. For camera sampling, efort could only be marginally reduced before inducing bias. We provide a decision tree for researchers to help make monitoring decisions.

54 ENVIRONMENTAL SCIENCES↗

Molecular and physical characteristics of aerosol at a remote free troposphere site: implications for atmospheric aging

Aerosol properties are transformed by atmospheric processes during long-range transport and play a key role in the Earth's radiative balance. To understand the molecular and physical characteristics of free tropospheric aerosol, we studied samples collected at the Pico Mountain Observatory in the North Atlantic. The observatory is located in the marine free troposphere at 2225 m above sea level, on Pico Island in the Azores archipelago. The site is ideal for the study of long-range-transported free tropospheric aerosol with minimal local influence. Three aerosol samples with elevated organic carbon concentrations were selected for detailed analysis. FLEXPART retroplumes indicated that two of the samples were influenced by North American wildfire emissions transported in the free troposphere and one by North American outflow mainly transported within the marine boundary layer.Ultrahigh-resolution Fourier transform ion cyclotron resonance mass spectrometry was used to determine the detailed molecular composition of the samples. Thousands of molecular formulas were assigned to each of the individual samples. On average ~60 % of the molecular formulas contained only carbon, hydrogen, and oxygen atoms (CHO), ~30 %contained nitrogen (CHNO), and ~10 % contained sulfur (CHOS). The molecular formula compositions of the two wildfire-influenced aerosol samples transported mainly in the free troposphere had relatively low averageO/C ratios (0.48±0.13 and 0.45±0.11) despite the 7–10 days of transport time according to FLEXPART. In contrast, the molecular composition of the North American outflow transported mainly in the boundary layer had a higher average O/C ratio (0.57±0.17) with 3 days of transport time. To better understand the difference between free tropospheric transport and boundary layer transport, the meteorological conditions along the FLEXPART simulated transport pathways were extracted from the Global Forecast System analysis for the model grids. We used the extracted meteorological conditions and the observed molecular chemistry to predict the relative-humidity-dependent glass transition temperatures (T g ) of the aerosol components. Comparisons of the T g to the ambient temperature indicated that a majority of the organic aerosol components transported in the free troposphere were more viscous and therefore less susceptible to oxidation than the organic aerosol components transported inthe boundary layer. Although the number of observations is limited, the results suggest that biomass burning organic aerosol injected into the free troposphere is more persistent than organic aerosol in the boundary layer having broader implications for aerosol aging.

54 ENVIRONMENTAL SCIENCES↗

Laser-induced magnetic fields in ICF capsules, Final Report, DE-FG02-08ER85128, Phase 1

Laser-induced magnetic fields in ICF capsules Final Report, DE-FG02-08ER85128, Phase 1 E. L. LINDMAN, Otowi Technical Services, Los Alamos, NM. The performance of an inertial-confinement-fusion (ICF) capsule can be improved by inserting a magnetic field into it before compressing it [Kirkpatrick, et al., Fusion Technol. 27, 205 (1995)]. To obtain standoff in an ICF power generator, a method of inserting the field without the use of low-inductance leads attached to the capsule is desired. A mechanism for generating such a field using a laser was discovered in Japan [Sakagami, et al., Phys. Rev. Lett. 42, 839 (1979), Kolodner and Yablonovitch, Phys. Rev. Lett. 43, 1402 (1979)] and studied at Los Alamos in the 1980s [M. A. Yates, et al., Phys. Rev. Lett. 49, 1702 (1982); Forslund and Brackbill, Phys. Rev. Lett. 48, 1614 (1982)]. In this mechanism, a p-polarized laser beam strikes a solid target producing hot electrons that are accelerated away from the target surface by resonant absorption. An electric field is created that returns the hot electrons to the target. But, they do not return to the target along the same trajectory on which they left. The resulting current produces a toroidal magnetic field that was observed to spread over a region outside the hot spot with a radius of a millimeter. No experimental measurements of the magnetic field strength were performed. Estimates from computer simulation suggest that field strengths in the range of 1 to 10 Mega gauss (100 to 1000 Tesla) were obtained outside of the laser spot. To use this mechanism to insert a magnetic field into an ICF capsule, the capsule must be redesigned. In one approach, a central conductor is added, a toroidal gap is cut in the outer wall and the DT fuel is frozen on the inner surface of the capsule. The capsule is dropped into the reaction chamber and struck first with the laser that generates the magnetic field. The laser hot spot is positioned at the center of the toroidal gap. As the magnetic field spreads from the hot spot over the surface that contains the toroidal gap, it will propagate through the gap and set up a steady state in the capsule. The main compression is then initiated. First, it closes the gap and crow-bars the field, then it compresses the fuel to ignition. In addition to this application, we discuss the use of this mechanism to induce Mega-gauss fields in laboratory apparatus for measurements of the effects of large magnetic fields on material samples. A preliminary target design for this purpose is presented. It is made of high-density material with no hydrogen surface contamination to minimize fast ion losses and to minimize x-ray preheat of the sample (the material, whose magnetic properties are to be measured). In it, the gap is designed to allow the magnetic field to move into the interior of the target while minimizing the flow of hot electrons into the interior. By adjusting the size of the gap as well as its configuration, the hot electron effects can be minimized. Since the strength of the magnetic field depends on the radial distance to the sample from the center of the conductor carrying the return current, the sample is located at a point of minimum conductor radius. This location also minimizes the effects on the measurement of any hot electrons that flow into the interior. Useful experiments can be accomplished with the “seed” field alone in this geometry. Compressing the capsule after the insertion of the seed field may allow experiments with even larger magnetic fields. We have used computer-simulation techniques to address a number of issues. Our conclusions include: • This magnetic-field generating mechanism is a viable method for generating magnetic fields in ICF targets and for laboratory experiments. • Useful experiments on material samples can be done with the seed field of 1 to10 Mega gauss (100 to 1000 Tesla) and higher magnetic fields can be obtained by subsequently compressing the capsule. • The results reported here can be studied experimentally with a modest CO2 laser that emits 4.5 J of energy in a 1-ns pulse focused into a 60-μm-diameter spot. • We have reproduced the published calculation of Forslund and Brackbill and extended the results to relativistic hot electrons. The difference in our peak magnetic field (1.25 Mg) versus that in the published calculation (1.3 Mg) is negligible. • We have shown that hot electrons can jump a gap while the magnetic field penetrates through the gap into an internal region. • We find that background plasma or a plasma gradient near the accelerating region is essential to the formation of the magnetic-field structures. • And, we have identified resistive losses in the surface return current as a serious issue that must be addressed in future work.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New Instrument for Time-Resolved OH and HO 2 Quantification in High-Pressure Laboratory Kinetics Studies

Here, we have constructed a new time-resolved high-pressure fluorescence assay by gas expansion (HP-FAGE) apparatus, optimized for the detection of OH and HO 2 radicals in complex gas-phase reactions. The new instrument fills a gap in the existing experimental toolkit for chemical kinetics by enabling the quantification of two key reactive species with microsecond time resolution from high-pressure sources, which was previously not attainable. The HP-FAGE is interfaced with a flow reactor, designed for pressures up to 100 bar and temperatures up to 1000 K, in which reactions are initiated by laser photolysis of radical precursors at repetition rates of 1–10 Hz. The HP-FAGE samples gas out of the reactor into a miniature FAGE chamber, where OH is detected by resonant laser-induced fluorescence using a time-delayed probe laser pulse. HO 2 is converted to OH via reaction with NO and then detected by OH fluorescence. The novel FAGE design places the probe region very close to the gas expansion, minimizing the transport time of sampled molecules and resulting in time resolution better than 20 μs for both OH and HO 2 . We calibrate the sensitivity of HP-FAGE, validate its performance with measurements of well-known reaction kinetics (OH + CH 4 , OH + OH, OH + HO 2 , and HO 2 + HO 2 ), and discuss prospects for its future use.

calibration↗

Scanning SQUID susceptometers with sub-micron spatial resolution

Superconducting QUantum Interference Device (SQUID) microscopy has excellent magnetic field sensitivity, but suffers from modest spatial resolution when compared with other scanning probes. This spatial resolution is determined by both the size of the field sensitive area and the spacing between this area and the sample surface. In this paper we describe scanning SQUID susceptometers that achieve sub-micron spatial resolution while retaining a white noise floor flux sensitivity of ≈2μΦ{sub 0}/Hz{sup 1/2}. This high spatial resolution is accomplished by deep sub-micron feature sizes, well shielded pickup loops fabricated using a planarized process, and a deep etch step that minimizes the spacing between the sample surface and the SQUID pickup loop. We describe the design, modeling, fabrication, and testing of these sensors. Although sub-micron spatial resolution has been achieved previously in scanning SQUID sensors, our sensors not only achieve high spatial resolution but also have integrated modulation coils for flux feedback, integrated field coils for susceptibility measurements, and batch processing. They are therefore a generally applicable tool for imaging sample magnetization, currents, and susceptibilities with higher spatial resolution than previous susceptometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Pyrolysis of Poplar Using a Captive Sample Reactor: Effects of Inorganic Salts on Primary Pyrolysis Products

We have constructed a captive sample reactor (CSR) to study fast pyrolysis of biomass. The reactor uses a stainless steel wire mesh to surround biomass materials with an isothermal environment by independent controlling of heating rates and pyrolysis temperatures. The vapors produced during pyrolysis are immediately entrained and transported in He carrier gas to a molecular beam mass spectrometer (MBMS). Formation of secondary products is minimized by rapidly quenching the sample support with liquid nitrogen. A range of alkali and alkaline earth metal (AAEM) and transition metal salts were tested to study their effect on composition of primary pyrolysis products. Multivariate curve resolution (MCR) analysis of the MBMS data shows that transition metal salts enhance pyrolysis of carbohydrates and AAEM salts enhances pyrolysis of lignin. This was supported by performing similar separate studies on cellulose, hemicellulose and extracted lignin. The effect of salts on char formation is also discussed.

09 BIOMASS FUELS↗