Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Parameters associated with design effect of child anthropometry indicators in small-scale field surveys

Background: Cluster surveys provide rapid but representative estimates of key nutrition indicators in humanitarian crises. For these surveys, an accurate estimate of the design effect is critical to calculate a sample size that achieves adequate precision with the minimum number of sampling units. This paper describes the variability in design effect for three key nutrition indicators measured in small-scale surveys and models the association of design effect with parameters hypothesized to explain this variability. Methods: 380 small-scale surveys from 28 countries conducted between 2006 and 2013 were analyzed. We calculated prevalence and design effect of wasting, underweight, and stunting for each survey as well as standard deviations of the underlying continuous Z-score distribution. Mean cluster size, survey location and year were recorded. To describe design effects, median and interquartile ranges were examined. Generalized linear regression models were run to identify potential predictors of design effect. Results: Median design effect was under 2.00 for all three indicators; for wasting, the median was 1.35, the lowest among the indicators. Multivariable linear regression models suggest significant, positive associations of design effect and mean cluster size for all three indicators, and with prevalence of wasting and underweight, but not stunting. Standard deviation was positively associated with design effect for wasting but negatively associated for stunting. Survey region was significant in all three models. Conclusions: This study supports the current field survey guidance recommending the use of 1.5 as a benchmark for design effect of wasting, but suggests this value may not be large enough for surveys with a primary objective of measuring stunting or underweight. The strong relationship between design effect and region in the models underscores the continued need to consider country- and locality-specific estimates when designing surveys. These models also provide empirical evidence of a positive relationship between design effect and both mean cluster size and prevalence, and introduces standard deviation of the underlying continuous variable (Z-scores) as a previously unexplored factor significantly associated with design effect. The magnitude and directionality of this association differed by indicator, underscoring the need for further investigation into the relationship between standard deviation and design effect.

60 APPLIED LIFE SCIENCES↗

Efficient Screening of Climate Model Sensitivity to a Large Number of Perturbed Input Parameters [plus supporting information]

Modern climate models contain numerous input parameters, each with a range of possible values. Since the volume of parameter space increases exponentially with the number of parameters N, it is generally impossible to directly evaluate a model throughout this space even if just 2-3 values are chosen for each parameter. Sensitivity screening algorithms, however, can identify input parameters having relatively little effect on a variety of output fields, either individually or in nonlinear combination.This can aid both model development and the uncertainty quantification (UQ) process. Here we report results from a parameter sensitivity screening algorithm hitherto untested in climate modeling, the Morris one-at-a-time (MOAT) method. This algorithm drastically reduces the computational cost of estimating sensitivities in a high dimensional parameter space because the sample size grows linearly rather than exponentially with N. It nevertheless samples over much of the N-dimensional volume and allows assessment of parameter interactions, unlike traditional elementary one-at-a-time (EOAT) parameter variation. We applied both EOAT and MOAT to the Community Atmosphere Model (CAM), assessing CAM’s behavior as a function of 27 uncertain input parameters related to the boundary layer, clouds, and other subgrid scale processes. For radiation balance at the top of the atmosphere, EOAT and MOAT rank most input parameters similarly, but MOAT identifies a sensitivity that EOAT underplays for two convection parameters that operate nonlinearly in the model. MOAT’s ranking of input parameters is robust to modest algorithmic variations, and it is qualitatively consistent with model development experience. Supporting information is also provided at the end of the full text of the article.

54 ENVIRONMENTAL SCIENCES↗

Quantitative Phase Composition of TiO 2 -Coated Nanoporous-Au Monoliths by X-ray Absorption Spectroscopy and Correlations to Catalytic

Porous titania/metal composite materials have many potential applications in the fields of green catalysis, energy harvesting, and storage in which both the overall morphology of the nanoporous host material and the crystallographic phase of the titania (TiO 2 ) guest determine the material’s performance. New insights into the structure–function relationships of these materials were obtained by near-edge X-ray absorption fine structure (NEXAFS) spectroscopy that, for example, provides quantitative crystallographic phase composition from ultrathin, nanostructured titania films, including sensitivity to amorphous components. We demonstrate that crystallographic phase, morphology, and catalytic activity of TiO 2 -functionalized nanoporous gold (np-Au) can be controlled by a simple annealing procedure (T < 1300 K). The material was prepared by atomic layer deposition of ~2 nm thick TiO 2 on millimeter-sized samples of np-Au (40–50 nm mean ligament size) and catalytically investigated with respect to aerobic CO oxidation. Moreover, the annealing-induced changes in catalytic activity are correlated with concurrent morphology and phase changes as provided by cross-sectional scanning electron microscopy, transmission electron microscopy, and near-edge X-ray absorption fine structure (NEXAFS) spectroscopy.

36 MATERIALS SCIENCE↗

Prismatic analyser concept for neutron spectrometers

Developments in modern neutron spectroscopy have led to typical sample sizes decreasing from few cm to several mm in diameter samples. We demonstrate how small samples together with the right choice of analyser and detector components makes distance collimation an important concept in crystal analyser spectrometers. We further show that this opens new possibilities where neutrons with different energies are reflected by the same analyser but counted in different detectors, thus improving both energy resolution and total count rate compared to conventional spectrometers. The technique can readily be combined with advanced focussing geometries and with multiplexing instrument designs. We present a combination of simulations and data showing three different energies simultaneously reflected from one analyser. Experiments were performed on a cold triple axis instrument and on a prototype inverse geometry Time-of-flight spectrometer installed at PSI, Switzerland, and shows excellent agreement with the predictions. Typical improvements will be 2.0 times finer resolution and a factor of 1.9 in flux gain compared to a focussing Rowland geometry, or of 3.3 times finer resolution and a factor of 2.4 in flux gain compared to a single flat analyser slab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Acceptance sampling using judgmental and randomly selected samples

We present a Bayesian model for acceptance sampling where the population consists of two groups, each with different levels of risk of containing unacceptable items. Expert opinion, or judgment, may be required to distinguish between the high and low-risk groups. Hence, high-risk items are likely to be identifed (and sampled) using expert judgment, while the remaining low-risk items are sampled randomly. We focus on the situation where all observed samples must be acceptable. Consequently, the objective of the statistical inference is to quantify the probability that a large percentage of the unsampled items in the population are also acceptable. We demonstrate that traditional (frequentist) acceptance sampling and simpler Bayesian formulations of the problem are essentially special cases of the proposed model. We explore the properties of the model in detail, and discuss the conditions necessary to ensure that required samples sizes are non-decreasing function of the population size. The method is applicable to a variety of acceptance sampling problems, and, in particular, to environmental sampling where the objective is to demonstrate the safety of reoccupying a remediated facility that has been contaminated with a lethal agent.

54 ENVIRONMENTAL SCIENCES↗

Electrostatic Beneficiation of Lunar Simulant

Electrostatic beneficiation of lunar regolith is a method allowing refinement of specific minerals in the material for processing on the moon. The use of tribocharging the regolith prior to separation was investigated on the lunar simulant MLS-I by passing the dust through static mixers constructed from different materials; aluminum, copper, stainless steel, and polytetrafluoroethylene (PTFE). The amount of charge acquired by the simulant was dependent upon the difference in the work function of the dust and the charging material. XPS and SEM were used to characterize the simulant after it was sieved into five size fractions (> 100 pm, 75-100 pm, 50- 75 pm, 50-25 pm, and < 25 pm), where very little difference in surface composition was observed between the sizes. Samples of the smallest (< 25 pm) and largest (> 100 pm) size fractions were beneficiated through a charge separator using the aluminum (charged the simulant negatively) and PTFE (charged positively) mixers. The mass fractions of the separated simulant revealed that for the larger particle size, significant unipolar charging was observed for both mixers, whereas for the smaller particle sizes, more bipolar charging was observed, probably due to the finer simulant adhering to the inside of the mixers shielding the dust from the charging material. Subsequent XPS analysis of the beneficiated fractions showed the larger particle size fraction having some species differentiation, but very little difference for the smaller.size. Although MLS-1 was made to have similar chemistry to actual lunar dust, its mineralogy is quite different. On-going experiments are using NASA JSC-1 lunar simulant. A vacuum chamber has been constructed, and future experiments are planned in a simulated lunar environment.

Trigwell, Steve↗

An iterative procedure for obtaining maximum-likelihood estimates of the parameters for a mixture of normal distributions

This paper addresses the problem of obtaining numerically maximum-likelihood estimates of the parameters for a mixture of normal distributions. In recent literature, a certain successive-approximations procedure, based on the likelihood equations, was shown empirically to be effective in numerically approximating such maximum-likelihood estimates; however, the reliability of this procedure was not established theoretically. Here, we introduce a general iterative procedure, of the generalized steepest-ascent (deflected-gradient) type, which is just the procedure known in the literature when the step-size is taken to be 1. We show that, with probability 1 as the sample size grows large, this procedure converges locally to the strongly consistent maximum-likelihood estimate whenever the step-size lies between 0 and 2. We also show that the step-size which yields optimal local convergence rates for large samples is determined in a sense by the 'separation' of the component normal densities and is bounded below by a number between 1 and 2.

Peters, B. C., Jr.↗

ChIPPS: Charged Information-storage Polymer Preparation System

Technological advances are required to support principal science objectives of missions to the solar system’s icy worlds to seek biosignatures of past/extant life. Sensitivity and reliability are key concerns due to small sample sizes (µL – mL) and the extraordinary import of the results. The preparation and processing of small samples can constrain limits of detection (LoDs); therefore, the Charged Information-storage Polymer Preparation System (ChIPPS) project is advancing the technologies of autonomous sample preparation and processing to add a new class of reliably detectable biosignatures: charged polymers and particles, which can be the information storage-and-transmission means for life. Specifically, we are developing an integrated microfluidic sample-processing unit to prepare icy-world samples to support complementary solid-state nanopore-based analyses: 1) charged-polymer analysis, to characterize variations in polymer chain size, shape, and charge vs. position along the chain; 2) polymer and nanoparticle sizing-and-counting, to characterize the relative abundance of polymer chains, as well as small (virus-sized) particles, by their dimensions and charge. Although no such autonomous system presently exists, such measurements can reveal the nature and abundance of charged polymers that could be used by biological systems to store and transfer information—as DNA and RNA are used terrestrially—without limitation to terrestrial nucleic acids, given that life elsewhere may utilize different information store-and-transfer moieties. Key system components include (a) a lysis unit for mechanical sample disruption; b) an ion-exchange column for charged macromolecule/nanoparticle purification; c) dialyzer to remove excess salt; d) concentrator to enhance signal; e) supporting pumps, valves, bubble traps, connectors, filters, etc.; f) interface to nanopore detection instruments.

Space Biology↗

High-throughput full-automatic synchrotron-based tomographic microscopy

At the TOMCAT (TOmographic Microscopy and Coherent rAdiology experimenTs) beamline of the Swiss Light Source with an energy range of 8-45 keV and voxel size from 0.37 {micro}m to 7.4 {micro}m, full tomographic datasets are typically acquired in 5 to 10 min. To exploit the speed of the system and enable high-throughput studies to be performed in a fully automatic manner, a package of automation tools has been developed. The samples are automatically exchanged, aligned, moved to the correct region of interest, and scanned. This task is accomplished through the coordination of Python scripts, a robot-based sample-exchange system, sample positioning motors and a CCD camera. The tools are suited for any samples that can be mounted on a standard SEM stub, and require no specific environmental conditions. Up to 60 samples can be analyzed at a time without user intervention. The throughput of the system is dependent on resolution, energy and sample size, but rates of four samples per hour have been achieved with 0.74 {micro}m voxel size at 17.5 keV. The maximum intervention-free scanning time is theoretically unlimited, and in practice experiments have been running unattended as long as 53 h (the average beam time allocation at TOMCAT is 48 h per user). The system is the first fully automated high-throughput tomography station: mounting samples, finding regions of interest, scanning and reconstructing can be performed without user intervention. The system also includes many features which accelerate and simplify the process of tomographic microscopy.

43 PARTICLE ACCELERATORS↗

A Taylor Expansion-Based Adaptive Design Strategy for Global Surrogate Modeling With Applications in Groundwater Modeling

Global sensitivity analysis (GSA) and uncertainty quantification (UQ) for groundwater modeling are challenging because of the model complexity and significant computational requirements. To reduce the massive computational cost, a cheap-to-evaluate surrogate model is usually constructed to approximate and replace the expensive groundwater models in the GSA and UQ. Constructing an accurate surrogate requires actual model simulations on a number of parameter samples. Thus, a robust experimental design strategy is desired to locate informative samples so as to reduce the computational cost in surrogate construction and consequently to improve the efficiency in the GSA and UQ. In this study, we develop a Taylor expansion-based adaptive design (TEAD) that aims to build an accurate global surrogate model with a small training sample size. TEAD defines a novel hybrid score function to search informative samples, and a robust stopping criterion to terminate the sample search that guarantees the resulted approximation errors satisfy the desired accuracy. The good performance of TEAD in building global surrogate models is demonstrated in seven analytical functions with different dimensionality and complexity in comparison to two widely used experimental design methods. The application of the TEAD-based surrogate method in two groundwater models shows that the TEAD design can effectively improve the computational efficiency of GSA and UQ for groundwater modeling.

58 GEOSCIENCES↗

Efficient Bayesian inference with latent Hamiltonian neural networks in No-U-Turn Sampling

When sampling for Bayesian inference, one popular approach in the computational field is to use Hamiltonian Monte Carlo (HMC) and specifically the No-U-Turn Sampler (NUTS), which automatically decides the end time of the Hamiltonian trajectory. However, HMC and NUTS can require numerous numerical gradients of the target density and can prove slow in practice when relying on computationally expensive forward models. We propose Latent Hamiltonian neural networks (L-HNNs) with HMC and NUTS for solving Bayesian inference problems. Once trained, L-HNNs do not require numerical gradients of the target density during sampling, and hence numerous evaluations of the forward computational model. Moreover, L-HNNs satisfy important properties such as perfect time reversibility and Hamiltonian conservation, making them well-suited for use within HMC and NUTS because stationarity can be shown. We also propose the integration of L-HNNs in an online error monitoring scheme, in which numerical gradients of the target density are used for a few samples whenever the L-HNNs prediction errors are large. This online error monitor scheme prevents sample degeneracy in regions of low probability density and ensures robust uncertainty quantification. We demonstrate L-HNNs in NUTS with online error monitoring on several analytical examples involving complex, heavy-tailed, and high-local-curvature probability densities. We then demonstrate the applicability of L-HNNs in NUTS to two computational case studies, namely the Allen-Cahn stochastic partial differential equation and an elliptic partial differential equation with 25 and 50 inference parameters, respectively. Overall, the L-HNNs in NUTS with online error monitoring satisfactorily inferred these probability densities. In conclusion, compared to traditional NUTS, L-HNNs in NUTS with online error monitoring required 1–2 orders of magnitude fewer numerical gradients of the target density and improved the effective sample size (ESS) per gradient (which is a measure of both the sampling quality and the computational expense) by an order of magnitude.

97 MATHEMATICS AND COMPUTING↗

Large volume high-pressure cell for inelastic neutron scattering

Inelastic neutron scattering measurements typically require two orders of magnitude longer data collection times and larger sample sizes than neutron diffraction studies. Inelastic neutron scattering measurements on pressurised samples are particularly challenging since standard high-pressure apparatus restricts sample volume, attenuates the incident and scattered beams, and contributes background scattering. Here, we present the design of a large volume two-layered piston-cylinder pressure cell with optimised transmission for inelastic neutron scattering experiments. The design and the materials selected for the construction of the cell enable its safe use to a pressure of 1.8 GPa with a sample volume in excess of 400 mm{sup 3}. The design of the piston seal eliminates the need for a sample container, thus providing a larger sample volume and reduced absorption. The integrated electrical plug with a manganin pressure gauge offers an accurate measurement of pressure over the whole range of operational temperatures. The performance of the cell is demonstrated by an inelastic neutron scattering study of UGe{sub 2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Irradiation Test Devices for Transient Testing

The Transient Reactor Test facility (TREAT) resumed operations in 2017 in order to reclaim its crucial role in nuclear-heated fuel safety research. TREAT’s historic era of operation (1959-1994) was best known for integral-scale testing of large fuel specimens/bundles under postulated reactor plant accident conditions, but TREAT also supported smaller-scale phenomena identification tests that elucidated fundamental behaviors and paved the way for these integral-scale tests. Advances in modern computational capabilities and a resurgence of interest in novel reactor technologies have created an opportunity for emphasizing modernized science-based and separate effects tests once again at TREAT. An innovative approach to this type of testing has been developed to leverage minor radioactivity built-in during brief TREAT irradiations by arranging smaller fuel specimens in low activation hardware so that they can be easily extracted and shipped for post irradiation examination within weeks. This recently-established capability, termed the Minimal Activation Retrievable Capsule Holder (MARCH) irradiation vehicle system, includes capabilities for cost-effective simplified-environment testing of centimeter-scale fuel samples of various geometries, temperature-controlled irradiations of millimeter-size samples for lower-length-scale model development, liquid-metal bonded heat sink capsules for controlling transient temperature response in fuel rodlets, and an innovative approach to high throughput irradiation of transient sensors and instrumentation. The MARCH system’s capabilities will also set the foundation for fuel safety research performed in larger integral-scale test devices with coolant environments representing reactor plants. Based upon historic approaches, but modernized to meet current nuclear technology needs, these larger irradiation devices include flowing pressurized water (including the ability to depressurize to steam) as well liquid metal cooling loops for various fuel rod and small bundle specimens. Here, this paper describes the recently-established MARCH system and current trajectory to enabling advanced transient science with a suite of irradiation test devices.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

LoCuSS: CALIBRATING MASS-OBSERVABLE SCALING RELATIONS FOR CLUSTER COSMOLOGY WITH SUBARU WEAK-LENSING OBSERVATIONS

We present a joint weak-lensing/X-ray study of galaxy cluster mass-observable scaling relations motivated by the critical importance of accurate calibration of mass proxies for future X-ray missions, including eROSITA. We use a sample of 12 clusters at z {approx_equal} 0.2 that we have observed with Subaru and XMM-Newton to construct relationships between the weak-lensing mass (M) and three X-ray observables, gas temperature (T), gas mass (M{sub gas}), and quasi-integrated gas pressure (Y{sub X}), at overdensities of {Delta} = 2500, 1000, and 500 with respect to the critical density. We find that M{sub gas} at {Delta} {<=} 1000 appears to be the most promising mass proxy of the three because it has the lowest intrinsic scatter in mass at a fixed observable, {sigma}{sub ln{sub M}} {approx_equal} 0.1, independent of the cluster dynamical state. The scatter in mass at fixed T and Y{sub X} is a factor of {approx}2-3 larger than at fixed M{sub gas}, which are indicative of the structural segregation that we find in the M-T and M-Y{sub X} relationships. Undisturbed clusters are found to be {approx}40% and {approx}20% more massive than disturbed clusters at fixed T and Y{sub X}, respectively, at {approx}2{sigma} significance. In particular, A 1914-a well-known merging cluster-significantly increases the scatter and lowers the normalization of the relation for disturbed clusters. We also investigated the covariance between the intrinsic scatter in M-M{sub gas} and M-T relations, finding that they are positively correlated. This contradicts the adaptive mesh refinement simulations that motivated the idea that Y{sub X} may be a low-scatter mass proxy, and agrees with more recent smoothed particle hydrodynamic simulations based on the Millennium Simulation. We also propose a method to identify a robust mass proxy based on principal component analysis. The statistical precision of our results is limited by the small sample size and the presence of the extreme merging cluster in our sample. We therefore look forward to studying a larger, more complete sample in the future.

79 ASTRONOMY AND ASTROPHYSICS↗

Reconsidering the effects of local star formation on type Ia supernova cosmology

Recent studies found a correlation with ∼3σ significance between the local star formation measured by GALEX in SN Ia host galaxies and the distances or dispersions derived from these SNe. We search for these effects by using data from recent cosmological analyses to greatly increase the SN Ia sample; we include 179 GALEX-imaged SN Ia hosts with distances from the Joint Light-curve Analysis (JLA) and Pan-STARRS SN Ia cosmology samples and 157 GALEX-imaged SN Ia hosts with distances from the Riess et al. H{sub 0} measurement. We find little evidence that SNe Ia in locally star-forming environments are fainter after light curve correction than SNe Ia in locally passive environments. We find a difference of 0.000 ± 0.018 (stat+sys) mag for SNe fit with SALT2 and 0.029 ± 0.027 (stat+sys) mag for SNe fit with MLCS2k2 (R{sub V}=2.5), which suggests that proposed changes to recent measurements of H{sub 0} and w are not significant and numerically smaller than the parameter measurement uncertainties. We measure systematic uncertainties of ∼0.01–0.02 mag by performing several plausible variants of our analysis. We find the greatly reduced significance of these distance modulus differences compared to Rigault et al. results from two improvements with fairly equal effects, our larger sample size and the use of the JLA and Riess et al. sample selection criteria. Without these improvements, we recover the results of Rigault et al. We find that both populations have similar dispersions in distance than found by Rigault et al. and Kelly et al., with slightly smaller dispersions for locally passive (log(Σ{sub SFR}) < −2.9 dex) SNe Ia fit with MLCS, the opposite of the effect seen by Rigault et al. and Kelly et al. We caution that measuring the local environments of SNe Ia in the future may require a higher resolution instrument than GALEX and that SN Ia sample selection has a significant effect on local star formation biases.

79 ASTRONOMY AND ASTROPHYSICS↗

Finite-size effects in lead scandium tantalate relaxor thin films

Large electromechanical effects in relaxor ferroelectrics are generally attributed to the collective response of an ensemble of correlated, nanometer-sized polar structures induced by chemical and charge disorder. Here, we study finite-size effects on such polar order (i.e., how it evolves when sample dimensions approach the polarization correlation length) in 7–70-nm-thick films of the relaxor ferroelectric PbSc 0.5 Ta 0.5 O 3 . Temperature-dependent polarization studies reveal a linear suppression of the polarization and nonlinearity associated with relaxor order as the film thickness decreases to ≈ 30 nm. Below this thickness, however, the suppression rapidly accelerates, and polarization is completely absent by film thicknesses of ≈ 7 nm, despite the continued observation of a broad peak in dielectric permittivity and frequency dispersion. Diffuse-scattering measurements reveal the diffuse-scattering symmetry, and analysis suggests the films have a polarization correlation length of ≈ 23 nm. Finally, taken together, it is apparent that reduction of sample size and the resulting distribution of polar structures drive suppression and eventual quenching of the electrical response of relaxors, which may be attributed to increasing dipole-dipole and dipole-interface interactions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Learning curves for drug response prediction in cancer cell lines

Motivated by the size and availability of cell line drug sensitivity data, researchers have been developing machine learning (ML) models for predicting drug response to advance cancer treatment. As drug sensitivity studies continue generating drug response data, a common question is whether the generalization performance of existing prediction models can be further improved with more training data. We utilize empirical learning curves for evaluating and comparing the data scaling properties of two neural networks (NNs) and two gradient boosting decision tree (GBDT) models trained on four cell line drug screening datasets. The learning curves are accurately fitted to a power law model, providing a framework for assessing the data scaling behavior of these models. The curves demonstrate that no single model dominates in terms of prediction performance across all datasets and training sizes, thus suggesting that the actual shape of these curves depends on the unique pair of an ML model and a dataset. The multi-input NN (mNN), in which gene expressions of cancer cells and molecular drug descriptors are input into separate subnetworks, outperforms a single-input NN (sNN), where the cell and drug features are concatenated for the input layer. In contrast, a GBDT with hyperparameter tuning exhibits superior performance as compared with both NNs at the lower range of training set sizes for two of the tested datasets, whereas the mNN consistently performs better at the higher range of training sizes. Moreover, the trajectory of the curves suggests that increasing the sample size is expected to further improve prediction scores of both NNs. These observations demonstrate the benefit of using learning curves to evaluate prediction models, providing a broader perspective on the overall data scaling characteristics. A fitted power law learning curve provides a forward-looking metric for analyzing prediction performance and can serve as a co-design tool to guide experimental biologists and computational scientists in the design of future experiments in prospective research studies.

60 APPLIED LIFE SCIENCES↗

Validation of the Scientific Program for the Dark Energy Spectroscopic Instrument

The Dark Energy Spectroscopic Instrument (DESI) was designed to conduct a survey covering 14,000 deg$^{2}$ over 5 yr to constrain the cosmic expansion history through precise measurements of baryon acoustic oscillations (BAO). The scientific program for DESI was evaluated during a 5 month survey validation (SV) campaign before beginning full operations. This program produced deep spectra of tens of thousands of objects from each of the stellar Milky Way Survey (MWS), Bright Galaxy Survey (BGS), luminous red galaxy (LRG), emission line galaxy (ELG), and quasar target classes. These SV spectra were used to optimize redshift distributions, characterize exposure times, determine calibration procedures, and assess observational overheads for the 5 yr program. In this paper, we present the final target selection algorithms, redshift distributions, and projected cosmology constraints resulting from those studies. We also present a One-Percent Survey conducted at the conclusion of SV covering 140 deg$^{2}$ using the final target selection algorithms with exposures of a depth typical of the main survey. The SV indicates that DESI will be able to complete the full 14,000 deg$^{2}$ program with spectroscopically confirmed targets from the MWS, BGS, LRG, ELG, and quasar programs with total sample sizes of 7.2, 13.8, 7.46, 15.7, and 2.87 million, respectively. These samples will allow exploration of the Milky Way halo, clustering on all scales, and BAO measurements with a statistical precision of 0.28% over the redshift interval z < 1.1, 0.39% over the redshift interval 1.1 < z < 1.9, and 0.46% over the redshift interval 1.9 < z < 3.5.

79 ASTRONOMY AND ASTROPHYSICS↗