Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensor data validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Advances in Rotational Seismic Measurements

Rotational motion is increasingly understood to be a significant part of seismic wave motion. Rotations can be important in earthquake strong motion and in Induced Seismicity Monitoring. Rotational seismic data can also enable shear selectivity and improve wavefield sampling for vertical geophones in 3D surveys, among other applications. However, sensor technology has been a limiting factor to date. The US Department of Energy (DOE) and Applied Technology Associates (ATA) are funding a multi-year project that is now entering Phase 2 to develop and deploy a new generation of rotational sensors for validation of rotational seismic applications. Initial focus is on induced seismicity monitoring, particularly for Enhanced Geothermal Systems (EGS) with fracturing. The sensors employ Magnetohydrodynamic (MHD) principles with broadband response, improved noise floors, robustness, and repeatability. This paper presents a summary of Phase 1 results and Phase 2 status.

58 GEOSCIENCES↗

Ubiquitous Nuclear Threat Detection Final Report, Harvey Mudd College Engineering Clinic

The Lawrence Livermore National Labs clinic team was asked to design a repeatable, portable procedure that would incentivize participants to carry detectors that form a radiation sensor network along repeated paths, to precisely known locations and past known radioactive sources. To achieve these goals, the team designed day-long and week-long data collection procedures in the form of puzzle hunt events. The team also created an Android app in order to support this measurement campaign and foster engagement. A ground truth collection method was constructed and validated through repeated use. Information concerning effective deployment of the data-collection procedure was gathered for future iterations. Over the course of procedural testing, 6 de 17 HMC students participated and collected 250 hours of data. 3 deployments of the procedure were conducted in each semester. A total of 63 students participated and collected 300 hours of data over the year. Deployment 1: 16 students, Deployment 2: 17 students, Deployment 3: 8 users, ~18 active hours, Deployment 4: 4 students, ~10 active hours, and Deployment 5: 18 students, ~40 active hours.

42 ENGINEERING↗

POD-based constrained sensor placement and field reconstruction from noisy wind measurements: A perturbation study

Sensor placement at the extrema of Proper Orthogonal Decomposition (POD) is efficient and leads to accurate reconstruction of the wind field from a limited number of measure- ments. In this paper we extend this approach of sensor placement and take into account measurement errors and detect possible malfunctioning sensors. We use the 48 hourly spa- tial wind field simulation data sets simulated using the Weather Research an Forecasting (WRF) model applied to the Maine Bay to evaluate the performances of our methods. Specifically, we use an exclusion disk strategy to distribute sensors when the extrema of POD modes are close. It turns out that this strategy can also reduce the error of recon- struction from noise measurements. Also, by a cross-validation technique, we successfully locate the malfunctioning sensors.

54 ENVIRONMENTAL SCIENCES↗

Fiber optic instrumentation for nuclear fuels and materials irradiations

The ability to predict the safety and reliability of new and advanced nuclear fuels and materials requires high-fidelity measurements during instrumented irradiation experiments. Optical fiber-based sensors are promising candidates for instrumentation in high-temperature (300-1200 C. degrees) irradiation environments, provided that signal attenuation due to radiation damage and/or high-temperature operation is not prohibitively large. To determine the feasibility of using silica optical fibers in instrumented irradiation capsules, a computational model has been developed to predict broadband optical attenuation in fused silica fiber materials as a function of time, temperature, and dose. Defect concentrations are calculated using a set of 11 coupled differential equations that include neutron-induced displacement, radiation-induced bond cleavage at precursor sites, and thermally-assisted molecular diffusion and defect recombination at elevated temperatures. Defect concentrations are coupled with the known optical properties of the various defects in fused silica to predict optical attenuation. The effects of radiation-induced compaction (i.e., formation of the 'metamict' phase) on the optical attenuation are also included. Results show that elevated temperatures significantly reduce attenuation resulting from defect centers (attenuation below ∼750 nm) as well as attenuation resulting from radiation-induced compaction (attenuation above ∼800 nm). The predicted attenuation is acceptable for most fiber optic-based sensor systems with a dynamic range on the order of 20-50 dB for a reasonable length (1-2 meters) of fiber in the high-flux region. Many optical components use a wavelength of 850 nm, which lies in the low-attenuation window. An irradiation campaign has been initiated to provide temperature-dependent optical attenuation data at high dose to validate the predictive model. (author)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cross-source sensing data fusion for building occupancy prediction with adaptive lasso feature filtering

Fusing various sensing data sources can significantly improve the accuracy and reliability of building occupancy detection. Fusing environmental sensors and wireless network signals are seldom studied for its computational and technical complexity. Here, this study aims to propose an integrated adaptive lasso model that is able to extract critical data features for environmental and Wi-Fi probe dual sensing sources. Through rapid feature extraction and process simplification, the proposed method aims to improve the computational efficiency of occupancy detecting models. To validate the proposed model, an onsite experiment was conducted to examine two occupancy data resolutions, (real-time and four-level occupancy resolutions). The results suggested that, among all twelve features, eight features are most relevant. The mean absolute error of the real-time occupancy can be reduced to 2.18 and F1_accuracy is about 84.36% for the four-level occupancy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mitigating urban heat island and enhancing indoor thermal comfort using terrace garden

The United Nations advocates for sustainable urban planning and design, emphasizing green infrastructure initiatives to mitigate urban heat island effects and enhance the resilience and livability of cities globally. To address urban heat challenges, a study was conducted in Chennai, India, from April to June 2023. The study focused on assessing temperature dynamics on a building's terrace by comparing a well-maintained garden area with an exposed region. Temperature and humidity sensors were deployed in both the garden and exposed areas of the terrace, as well as within rooms beneath it, to monitor hourly temperature fluctuations. The findings indicate a significant reduction in internal room temperatures in areas with rooftop gardens, ranging from 4 to 11 °C, depending on the time of year and sun's position, compared to rooms with fully exposed roof configurations. Additionally, simulation studies were performed to validate these findings, suggesting that optimizing the distribution of soil beds and plant density across the roof could yield an additional temperature reduction of 3–4 °C, resulting in an overall difference of up to 14–15 °C. The study highlights the efficacy of rooftop gardens in providing cooling effects during daylight hours and maintaining temperature parity post-sunset. Through analysis of sensor data, the research elucidates the intricate relationship between green infrastructure and thermal comfort, offering insights for energy-efficient building design and resilient urban planning. The findings underscore the potential of rooftop gardens in fostering a more comfortable, energy-efficient, and sustainable urban living environment.

54 ENVIRONMENTAL SCIENCES↗

An empirical method that separates irreversible stem radial growth from bark water content changes in trees: theory and case studies

Substantial uncertainty surrounds our knowledge of tree stem growth, with some of the most basic questions, such as when stem radial growth occurs through the daily cycle, still unanswered. Here, we employed high-resolution point dendrometers, sap flow sensors, and developed theory and statistical approaches, to devise a novel method separating irreversible radial growth from elastic tension-driven and elastic osmotically driven changes in bark water content. We tested this method using data from five case study species. Experimental manipulations, namely a field irrigation experiment on Scots pine and a stem girdling experiment on red forest gum trees, were used to validate the theory. Time courses of stem radial growth following irrigation and stem girdling were consistent with a-priori predictions. Patterns of stem radial growth varied across case studies, with growth occurring during the day and/or night, consistent with the available literature. Importantly, our approach provides a valuable alternative to existing methods, as it can be approximated by a simple empirical interpolation routine that derives irreversible radial growth using standard regression techniques. In conclusion, our novel method provides an improved understanding of the relative source–sink carbon dynamics of tree stems at a sub-daily time scale.

59 BASIC BIOLOGICAL SCIENCES↗

Adaptive Cyber-Physical Resilience for Building Control Systems

The main goal of the project is to develop an AI-based process layer cybersecurity suite for detection, isolation and mitigation of cyber-attack effects on operation of building energy management systems (BEMS). The following constituent key technologies were developed under the program towards fulfilling the program objectives: (1) developed a high fidelity BEMS testbed for generation of training data and validation of developed technologies; (2) developed a physics informed ML based attack detection and localization module (ADL) capable of detecting high impact stealthy attacks (HISA - attacks causing 30% energy utilization but no immediate visible impact otherwise) with 98% accuracy; (3) developed a methodology to determine ’representative days’ to limit the data required for training; (4) developed a virtual sensing system that can reconstruct affected sensors with 10% error for the same HISA set; (5) developed a resilient model predictive control system that can continue operation of the BEMS without jeopardizing stability for the HISA set; and (6) integrated and deployed all the constituent modules and demonstrated the efficacy of the technology in real-time in a hardware in loop simulation.

42 ENGINEERING↗

In-Flight Gain Monitoring of SPIDER’s Transition-Edge Sensor Arrays

We report experiments deploying large arrays of transition-edge sensors (TESs) often require a robust method to monitor gain variations with minimal loss of observing time. We propose a sensitive and non-intrusive method for monitoring variations in TES responsivity using small square waves applied to the TES bias. We construct an estimator for a TES’s small-signal power response from its electrical response that is exact in the limit of strong electrothermal feedback. We discuss the application and validation of this method using flight data from SPIDER, a balloon-borne telescope that observes the polarization of the cosmic microwave background with more than 2000 TESs. This method may prove useful for future balloon- and space-based instruments, where observing time and ground control bandwidth are limited.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution time-resolved experiments on mixing and entrainment of buoyant jets in stratified environments

Fluid jets interacting with a stratified layer play an important role in the safety of several reactor designs. In the containment of nuclear power plants, fluid jets dominate the transport and mixing of gaseous species and consequent hydrogen distribution in case of a severe accident. The mixing phenomena in the containment are driven by buoyant high-momentum injections (jets) and low momentum injection plumes. Mixing near the postulated break is initially dominated by high flow velocities. Plumes with moderate flow velocities are instead relevant in the break compartment during the long-term pressurization phase, or in any of the apertures between two connected compartments if the mass flows are sufficiently high and the density differences between efflux and ambient are sufficiently low. Phenomena of interest include free plumes (as produced by the efflux from the break compartment in a larger room or directly from a break flow), wall plumes (such those produced by low mass flows through inter-compartment apertures), and propagating stratification fronts in the ambient (for any stably stratified conditions). These phenomena have been highly ranked about nuclear reactor design, especially regarding of safety protocols. During a Pressurized Thermal Shock (PTS) scenario, the interaction between the cold ECCS injection plume and the stratified fluid present in the cold (or hot) leg is important in order to determine the temperature at the time-dependent temperature at the inlet of the reactor pressure vessel (RPV) and the potential to cause a thermal shock on the RPV wall. In sodium-cooled fast reactors (SFRs), core channels are typically hydro-dynamically isolated so that there exists a considerable temperature variation at the exit of adjacent fuel assemblies. All the above phenomena are characterized by the interaction of buoyant jets with the stratified flow. In stratified layers baroclinic forces create significant redistribution of turbulent kinetic energy and scales, which leads to anisotropy. This important physical phenomenon is highly three dimensional and is challenging to capture even with high-fidelity CFD simulations, due in part to lack of sufficiently resolved validation data. Furthermore, the experimental data available in the open literature do not feature the level of fidelity needed for an extensive validation of turbulence models in lower order CFD. To shed new lights into the crucial phenomena object of the present research project, it was proposed to conduct coordinated experiments and simulations at the University of Michigan and the George Washington University. The project has resulted in an experimental database of high-resolution time-resolved measurements of jets in uniform and stratified environments. The novel experimental data will be used to validate computational fluid dynamic (CFD) codes, including both Large Eddy Simulations (LES) and unsteady Reynolds-averaged Navier-Stokes equations (URANS) methodologies. In the Experimental and Multiphase flow (ECMF) laboratory at Univerisity of Michigan, we built two experimental facilities to investigate also the effect of scaling. The first facility, DESTROJER (DEnsity Stratified Turbulent ROund free Jet ExpeRiment), featuring a contoured jet nozzle with a diameter of D=12.7mm and a 1m×1m×1m cubic tank, which is made of acrylic glass for optical access. The ratio between the tank width and the nozzle diameter is equal to 78, which ensures that there is no direct interaction between the jet and the side walls. A second, modular experimental facility, features three different tank sizes of size 10×10×30, 20×20×30, 30×30×30 cm3 respectively (all tanks have the same height of 30 cm), and a jet diameter of 2mm. For the modular facility, tank-to-nozzle ratio of 50, 100, and 150 are obtained respectively. Experiments with different-density jet impactions and sharp interface with a density difference of 3.16% In the Laboratory at George Washington University, complementary experiments have been carried out at a facility featuring the same dimensions as DESTROYER. Experiments with different jet diameters have been carried out as well. High-resolution time-resolved measurements have been performed at all facilities using high-speed particle image velocimetry (PIV) and planar laser-induced fluorescence (PLIF). In this way, simultaneous measurements of velocity and density fields have been carried out. At the University of Michigan, wire-mesh sensors have been designed and built to gather high-resolution, time-dependent data of the stratified front in the tank. These measurements are important to provide accurate initial conditions for the CFD simulations. An important outcome of the project has been the development of novel techniques to achieve refractive index matching (RIM) of acqueous solutions with high density differences. RIM is crucial if optical techniques such as PIV are used to measure velocity fields. Previous to this project, experiments up to 3% density difference had been reported in the literature. With the methodology developed in this project, we have been able to push the envelop to density differences up to 9%. The experiments have been used to validate Reynolds Averaged Navier-Stokes (RANS) turbulence models and Large Eddy Simulations (LES) models. Both NEK5000 and the commercial CFD code STAR-CCM+ have been used. The experimental data will be made available to the community through the NE-KAMS databasehave been successfully conducted in the scaled facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Innovative Patient Room Lighting System with Integrated Spectrally Adaptive Control

In December of 2013, the U.S. Department of Energy’s SSL R&D Program released a Funding Opportunity Announcement (FOA), that for the first time, contained opportunities for comprehensive application-specific system development. The FOA included opportunities for two applications, one of which was a Patient Room. Philips Lighting Research North America, submitted a proposal for the Patient Room application, and was selected for the complete project award. The award amount was for $497,127, with a Philips Research co-funding commitment 165,709 dollars. The total project value was 662,836 dollars. This project sought to redefine lighting for the patient room application. The goal was to deliver an innovative LED patient suite (patient room and bathroom) lighting system solution that was 40% more energy-efficient than traditional fluorescent incumbent technologies, and would meet all the visual and non-visual needs of patients, caregivers and visitors, and improve the patient experience. State-of-the-art multichannel LED platforms and control technologies that would provide spectral tuning and become part of an intelligent, connected lighting system drove the solution. The project was scoped into four main task areas that included a) System Concept Creation, b) Identification of the Luminaire Portfolio, c) Development of the Connected Lighting Infrastructure, and d) System Performance Validation. Each of the four main tasks were completed and validated extensively over the course the 2 ½ year project. The system concept was created by first developing a lighting design that demonstrated best practices for patient room lighting – illuminance and uniformity for task performance, reduced glare, and convenient controls, in addition to giving patients control over the lighting in their environment. A framework was defined to deliver circadian support via software behaviors. Through that process luminaires were identified from the Philips portfolio that were adaptable – by their form, dimensions, and optical materials – to mix multicolor LED platforms uniformly and deliver target design lumen levels. The Blue Sky luminaire was selected for the patient bed area to give the illusion of skylight while providing white light on the patient bed. Luminaires used existing 2-channel tunable white LED boards, and newly developed 4-channel LED boards. Red-Orange, Blue, Green, and Blue-shifted Yellow LED chips were selected based on spectral characteristics and their ability to produce high quality white light. 4-channel Power over Ethernet (PoE) drivers were developed and firmware written so they would communicate with both 2- and 4-channel boards. These components formed the backbone of the connected lighting infrastructure. Software, flexible and nuanced in its complexity, was written to set behaviors for myriad lighting scenes in the room throughout the 24 hour day – and all could be overridden by manual controls. This included a dynamic tunable white program, three color changing automatic programs that simulated degrees of sunrise to sunset palettes, and an amber night lighting system that offered visual cues for postural stability to minimize the risk of falls. All programs were carefully designed to provide visual comfort for all occupants, support critical task performance for staff, and to support the patient’s 24hr rhythms. A full scale mockup room was constructed in the Philips Cambridge Lab. The lighting system was installed, tested and functionality demonstrated to ensure smooth operation of system components – luminaires, drivers, PoE switches, wall controls, patient remote, and daylight and occupancy sensors. How did the system perform? It met visual criteria, confirmed by calculations, simulations and measurements in the field. It met non-visual criteria, confirmed by setting circadian stimulus (CS) targets and performing calculations using the calculator developed by the Lighting Research Center. Finally, human factors validation studies were conducted to gain insight from real end users in the healthcare profession; surveys were administered, data analyzed, and audio comments captured. The general consensus was positive, with requests to pilot the system in their hospitals. The importance of the research completed under this grant is that it allowed the exploration and development of a unique lighting system, one that would deliver a blend of visual and non-visual criteria in patient room design for today’s healthcare environment. The research investigated the area of multichannel LED technology, multichannel Power over Ethernet (PoE) drivers and their integration with automatic and manual controls as a system – uncovering and meeting challenges along the way. It married visual needs of patients and staff with support for 24 hour rhythms, placing value on the wellbeing of the patient – while successfully saving energy over incumbent technologies. Indications are that the market is ready and willing to invest – multiple healthcare facilities are in line to pilot this system, recognizing its value beyond energy to patient and staff well-being. Its value to the public can best be expressed by a patient support coordinator who, after spending several hours in the room being immersed in the lighting, analyzing all its features, commented: “This re-writes lighting for healthcare”.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling Validation of Mechanical and Thermal Borehole Breakouts From Polyaxial Laboratory Tests to Determine Maximum Horizontal in Situ Stress

To accurately assess rock behavior in the deep subsurface, it is necessary to measure the in situ stress directions and magnitudes. The current methods for measuring the in situ stress state in the deep subsurface primarily include hydraulic fracturing tests (i.e., the minimum horizontal stress) or occasionally observing existing compressive borehole breakouts (i.e., the maximum horizontal stress) that have occurred naturally from drilling. If there are no existing compressive breakouts in a borehole, the maximum horizontal in situ stress cannot be estimated with much confidence. In response to this data gap, a new thermal breakout technology is being developed that will provide a method for thermally inducing borehole breakouts and obtaining consistent measurements of the maximum horizontal stress magnitude. This thermal breakout technology involves heating the borehole and increasing the thermoelastic compressive stress in the rock until a breakout develops, which is directly correlated to the maximum horizontal stress magnitude. In support of developing the thermal breakout technology, polyaxial laboratory tests have been performed on small-scale boreholes within rock blocks where mechanically- and thermally-induced borehole breakouts have been created. Numerical models along with the principal of superposition were created and used to analyze the polyaxial laboratory tests to predict the maximum horizontal stress, given the same data that would be obtained in an actual subsurface borehole thermal breakout test. Multiple failure criteria were used to evaluate the best prediction of the breakout onset and maximum horizontal stress. The maximum horizontal stress predictions were compared to the actual maximum horizontal stress applied at breakout using acoustic events recorded from emission sensors in the polyaxial tests. The results showed consistent results that could be used to refine the modeling approach and failure criterion that are used to make the maximum horizontal stress predictions. This study provided insight and validation for the thermal breakout stress measurement concept.

Jones, Matt↗

Robust online monitoring for calibration assessment of transmitters and instrumentation - 260

Robust online monitoring (OLM) technologies are expected to enable the extension or elimination of periodic sensor calibration intervals in operating and new reactors. Advances in OLM technologies will improve the safety and reliability of current and planned nuclear power systems through improved accuracy and increased reliability of sensors used to monitor key parameters. In this paper, we discuss an overview of research being performed within the Nuclear Energy Enabling Technologies (NEET)/Advanced Sensors and Instrumentation (ASI) program, for the development of OLM algorithms to use sensor outputs and, in combination with other available information, 1) determine whether one or more sensors are out of calibration or failing and 2) replace a failing sensor with reliable, accurate sensor outputs. A Gaussian Process (GP)-based uncertainty quantification (UQ) method previously developed for UQ in OLM, was adapted for this purpose. The resulting models are being evaluated for use in high-confidence signal validation for the purpose of detecting and diagnosing sensor faults, and for computing virtual sensor outputs that may be used as a temporary replacement for failing sensors. In addition to assessing sensor drift, approaches for extracting sensor response time in an automated fashion were developed, for monitoring changes in sensor response time in pressure transmitters. Such changes are also indicative of various fault modes. These algorithms were evaluated with existing measurement data from several laboratory-scale flow loops. Ongoing research in this project is focused on further evaluation of the algorithms, optimization for accuracy and computational efficiency, and integration into a suite of tools for robust OLM that are applicable to monitoring sensor calibration state in nuclear power plants. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

EVALUATION OF OPERATION TEMPERATURES UNDER NATURAL CONVECTION HELIUM FLOW IN A CONFINED CAVITY

The Spallation Neutron Source (SNS) is a high-power accelerator-based pulsed neutron source led by Oak Ridge National Laboratory (ORNL) to achieve high fluxes of neutrons for scientific experiments. Active and passive cooling of the systems and parts forming the SNS have been considered to warrant the safe operation of the facility. The diverse cooling systems make use of conjugated heat transfer mechanisms to provide a stable operation temperature for all components in the machine. Thermal power deposited into stainless-steel piping lines due to particle radiation may reach values of up to 1.2 W/cc in the regions located closer to the center of the lower IRP. These energy deposition levels, in not actively cooled components, such as the transfer-line-outer-vacuum-layer may increase the temperature of the component beyond design requirement limitations. The evaluation of the operation temperatures for the former components relies in the assumption that a low-pressure helium atmosphere provides enough heat removal capacity based on natural convection phenomena. In this work, the evaluation of steady state temperatures in components such as the CMS transfer lines has been evaluated using computational fluid dynamics (CFD), analytical correlations and experimental measurements. The companion experiments were conducted in a closed helium system at pressures varying from 1.1 to 1.5 bar. A copper rod was affixed horizontally between viewing windows and heated at constant power, and measurements were made of both the rod temperature and ambient temperature via a system fiberoptic distributed temperature sensors and RTDs. It was found that the measured heat transfer coefficients agree well with the predictions of Churchill and Chu correlations across the range of cases considered. Additionally, the ambient helium volume above the rod was imaged via background oriented schlieren (BOS), and these data was used to determine the line-averaged density gradients in this region. These gradients were compared to simulation data to validate the predictions of natural convection simulations.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗

Sci—Fri PM: Dosimetry—06: Commissioning of a 3D patient specific QA system for hypofractionated prostate treatments

The objective of this work is to commission the 6MV-SRS beam model in COMPASS (v2.1, IBA-Dosimetry) and validate its use for patient specific QA of hypofractionated prostate treatments. The COMPASS system consists of a 2D ion chamber array (MatriXX{sup Evolution}), an independent gantry angle sensor and associated software. The system can either directly calculate or reconstruct (using measured detector responses) a 3D dose distribution on the patient CT dataset for plan verification. Beam models are developed and commissioned in the same manner as a beam model is commissioned in a standard treatment planning system. Model validation was initially performed by comparing both COMPASS calculations and reconstructions to measured open field beam data. Next, 10 hypofractionated prostate RapidArc plans were delivered to both the COMPASS system and a phantom with ion chamber and film inserted. COMPASS dose distributions calculated and reconstructed on the phantom CT dataset were compared to the chamber and film measurements. The mean (± standard deviation) difference between COMPASS reconstructed dose and ion chamber measurement was 1.4 ± 1.0%. The maximum discrepancy was 2.6%. Corresponding values for COMPASS calculation were 0.9 ± 0.9% and 2.6%, respectively. The average gamma agreement index (3%/3mm) for COMPAS reconstruction and film was 96.7% and 95.3% when using 70% and 20% dose thresholds, respectively. The corresponding values for COMPASS calculation were 97.1% and 97.1%, respectively. Based on our results, COMPASS can be used for the patient specific QA of hypofractionated prostate treatments delivered with the 6MV-SRS beam.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel, Low-Cost, Light-Weight High Efficiency (H*10 Capable) Neutron Detector-Dosimeter

The goal of this project was to design, develop and validate a novel, spectroscopy enabled H*(10) neutron dosimetry system based on the tensioned metastable fluid detector (TMFD) sensor technology. The project team consisted of staff from Oak Ridge National Laboratory (ORNL), Purdue University (PU) and Sagamore Adams Laboratories, LLC (SAL). PU-SAL staff were tasked with the design, development, construction and testing of the H*TMFD hardware and software, along with developing the control and data acquisition software for comparison of predictions from H*TMFD against a commonly accepted and widely used industry standard system; for this project, the Li-I detector coupled to bonner spheres (LiI-BSS) system manufactured by Ludlum, Inc. was utilized as the reference (“gold”) standard – similar in terms of neutron spectroscopy enablement to another industry recognized, albeit, significantly higher cost (est. $300K) system referred to as “ROSPEC” (from BTI, Inc., which was not available for this project). ORNL staff were tasked with providing field-relevant guidance, apparatus and facilities for acquiring data against calibrated neutron sources, and comparing results of H*TMFD against LiI-BSS system predictions in a series of blind-tests conducted at ORNL. Over the course of 12 months, the PU-SAL-ORNL staff successfully accomplished the proposed technical and administrative tasks, inclusive of engaging in outreach to potential users of this technology in the DOE-wide infrastructure. The proposed tasks were successfully accomplished in timely manner; the follow-up type tasks pertaining to SBIR type Phases 2-3 were discussed and are initiated, inclusive of filing for intellectual property (IP) disclosures and possible patent filings by PU’s Office of Technology Commercialization (OTC). Two H*TMFD system architectures (see Exhibits 1 & 2 in the report) were developed and constructed for hand-portability by health-physicists (HPs) – the HP-H*TMFD, and the H*TMFD system which consists of a side-by-side mounted array of 4 TMFDs of 3 different sizes in sensitive volume (including one with borated fluid) that now simultaneously enables neutron energy spectroscopy: single bin for < 0.1 MeV, and 152 energy bins in the 0.1-15.2 MeV range; H*(10) dosimetry from ~5 μRem/h towards 10 R/h ranges. Several experiments were conducted using neutron sources in various configurations (shielded and unshielded). In direct comparison against the LiI-BSS industry standard (acquiring data for 26h each source), the H*TMFD system (acquiring data for ~6h for each source) offered H*(10) dose predictions for the most part accurate to within +/-10% for dose rates in the 100-300 μRem/h range. The LiI-BSS was impractical to use under ultra-low (~10 μRem/h) dose rate space, as also another metering device used at ORNL (Ludlum 4241L non-spectroscopy enabled) for which the lower limit is set by the manufacturer at 100 μRem/h. The enablement for efficient use in timely manner at the 10 μRem/h levels is deemed to be a strong enabling factor for H*TMFD for use in the DOE-nuclear laboratory arena. In terms of weight, the HP-H*TMFD weighs under ~5-7 lb.; the H*TMFD system weighs ~35-lb. As such, it is ~1/4 the weight of an LiI-BSS system weighing ~120 lb (LiI detector with 6 bonner spheres) and, ~1/2 the weight of ROSPEC. As a result of this activity, two involved post-doctoral student staff have now transitioned their knowledge and experiences to DOE’s Pacific Northwest National Laboratory (PNNL). A PU graduate student has also benefited from this project work which formed a principal basis for his Ph.D. dissertation work (in progress).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Introducing “ The Integrator ”: A novel technique to monitor environmental flow systems

Abstract We introduce “ The Integrator ,” a novel technique to quantify transport and reaction metrics commonly used to characterize flow systems. This development consists of two products: (1) The Integrator sampling device and (2) its supporting mathematical framework, which is compatible with semi‐continuous sensor data. The use of The Integrator device simplifies the logistics of sample collection and greatly reduces the number of samples needed, making it ideal to characterize systems that are: (1) difficult to access, (2) large and thus intractable or highly heterogeneous, and (3) highly instrumented otherwise but where a more holistic, mechanistic understanding may be gained by monitoring one or more currently untracked elements. We tested and validated The Integrator technique using experimental data collected from a heart rate monitor (high‐quality, high‐frequency data in response to known excitation events) and solute tracer experiments conducted in two contrasting (fourth and seventh order) rivers. In the Supporting Information , we provide details concerning the design of The Integrator device used in our field case studies and provide insight into potential improvements. Despite our case studies focus on the analysis of conservative and reactive transport of solutes in rivers, the principles behind The Integrator technique can be used to monitor water quality in hyporheic zones, aquifers, wetlands, swamps, karsts, oceans, wastewater treatment plants, pipe networks, and air quality. Furthermore, special arrangements of Integrator devices can be used to gather data at spatial and temporal resolutions that are currently unattainable due to high transportation and/or personnel costs.

54 ENVIRONMENTAL SCIENCES↗

TEAMER: Performance mapping of Re Vision's Persistance PTO

Contains datasets from experimental measurements that were used to validate Re Vision's Persistence PTO's efficiency and performance. These measurements were obtained using a dynamometer test bench setup. The data includes open-circuit voltage and loss measurements to validate machine characteristics, efficiency mapping tests to determine the generator's performance mapping, and efficiency mapping tests to determine the converter's efficiency over the feasible operating range. This data was collected between June 2023 and September 2023. The data was collected at the National Renewable Energy Laboratory's Flatirons Campus, Colorado, United States. The data was collected using NREL's 5-kW dynamometer test bench, equipped with a torque sensor and various voltage and current sensors fed to a dedicated data acquisition system. Units for the data are included in the data file headers for each data series. A text editor or spreadsheet software such as Excel is required to view the *.csv data. The data are also provided in *.mat files. To view data plots, a Matlab script with *.mat files are provided.

16 TIDAL AND WAVE POWER↗