Search NASA⌕ Search

SEARCH · Search NASA

Results for “service systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Stress Testing California's Hydroclimatic Whiplash: Potential Challenges, Trade‐Offs and Adaptations in Water Management and Hydropower Generation

Abstract Inter‐annual precipitation in California is highly variable, and future projections indicate an increase in the intensity and frequency of hydroclimatic “whiplash.” Understanding the implications of these shocks on California's water system and its degree of resiliency is critical from a planning perspective. Therefore, we quantify the resilience of reservoir services provided by water and hydropower systems in four basins in the western Sierra Nevada. Using downscaled runoff from 10 climate model outputs, we generated 200 synthetic hydrologic whiplash sequences of alternating dry and wet years to represent a wide range of extremes and transitional conditions used as inputs to a water system simulation model. Sequences were derived from upper (wet) and lower (dry) quintiles of future streamflow projections (2030–2060). Results show that carryover storage was negatively affected in all basins, particularly in those with lower storage capacity. All basins experienced negative impacts on hydropower generation, with losses ranging from 5% to nearly 90%. Reservoir sizes and inflexible operating rules are a particular challenge for flood control, as in extremely wet years spillage averaged nearly the annual basins' total discharge. The reliability of environmental flows and agricultural deliveries varied depending on the basin, intensity, and duration of whiplash sequences. Overall, wet years temporarily rebound negative drought effects, and greater storage capacity results in higher reliability and resiliency, and lesser volatility in services. We highlight potential policy changes to improve flexibility, increase resilience, and better equip managers to face challenges posed by whiplash while meeting human and environmental needs.

Environmental Sciences & Ecology↗

Field Demonstration of Residential DER Service-Oriented Load Participation

Amidst a concerning surge in power consumption during peak hours, coupled with heightened power grid instability, and driven by a growing demand for electricity, aggregations of Distributed Energy Resource are becoming a viable means for providing essential reliability services.Electric utility companies have proactively implemented Demand Response programs for decades. These programs employ Direct Load Control methods to enhance power grid stability, achieved by controlling customers’ Distributed Energy Resource during peak hours to reduce power consumption. However, a notable drawback of Direct Load Control has been high unenrollment rates of DR program participants due to customer discomfort.Therefore, the underlying issue of over-consumption persists. To address these concerns, this paper introduces a Service-Oriented Load Participation approach to providing grid services such as Demand Response. Leveraging a Service-Oriented Architecture, this method offers the advantage of efficient service management and provisioning within the system. The SOLP approach not only aims to reduce power consumption but also to maintain customer satisfaction by ensuring a comfortable grid service experience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Use of Operating Agreements and Energy Storage to Reduce Photovoltaic Interconnection Costs: Technical and Economic Analysis

This report presents an analytical methodology to identify alternative options to manage interconnection costs and streamline interconnection timelines for distribution system-connected photovoltaic (PV) systems not co-located with load. Specifically, the report details the methodology and results of an analysis that: 1. Identifies potential grid violations that would be induced by a PV system requesting interconnection to a distribution circuit; 2. Identifies multiple technically viable options for mitigating the potential violations, including infrastructure upgrades, downsizing the PV system size, curtailment of PV, and addition of battery energy storage; 3. Defines the required technical operating parameters of the system in order to mitigate all potential violations (the "Operating Envelope"); 4. Compares the economics of each option, from the PV developer's perspective. The analysis supports the ongoing evolution of interconnection standards for combined PV and energy storage systems by providing a methodology to define allowable maximum export limits during each hour. The methodology presented could be used by utilities as part of the interconnection study process, to inform negotiations with DER developers and the drafting of mutually acceptable interconnection agreements. The resulting technical operating parameters could be included as part of the interconnection service agreement (ISA) between the system owner and the utility company. The companion report to this analysis, Gill et al. (2022), details the envisioned framework for the implementation of the technical operating parameters.

14 SOLAR ENERGY↗

Providing Ancillary Services with Photovoltaic Generation in Multi-Timescale Grid Operation: Preprint

With photovoltaic (PV) generation substantially increases, electric power systems need more flexible resources that can provide ancillary services to mitigate the variability and uncertainty of the PV generation. On the one hand, the increase of PV generation necessitates the needs of more flexible resources. On the other hand, PV generation, because of its low operation cost, has been replacing the conventional generation in the system which is the main flexible resources in the current system. Consequently, there is a trend to require the renewable generation including PV to provide flexible ancillary services to further accommodate more PV integration. This paper proposes a multi-timescale grid operation model considering the various control strategies of PV providing different ancillary services. Numerical case studies demonstrate that with PV providing both regulation reserve and primary frequency reserve, the system operating costs and PV curtailment will be reduced significantly. It shows that not only the system reliability but also PV's profitability can be improved with PV providing more ancillary services.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Anomaly Detection and Mitigation for Dynamic Frequency Regulation in Hydropower-Battery Systems

Hydropower operators and energy storage providers are increasingly interested in participating in frequency regulation services, driven by the incentives offered by independent system operators, such as the PJM Interconnection. This transition, however, unfolds against the backdrop of a modernizing and rapidly digitizing power grid, exposing the integrated legacy infrastructure to a multitude of cybersecurity threats. This work presents an approach for developing an anomaly detection and mitigation system to address cybersecurity challenges during the participation of a hydropower-integrated battery energy storage system (BESS) in a frequency regulation market. The applied anomaly detector utilizes machine learning algorithms to provide detailed classification of cyber-physical events. Later, the applied mitigation system triggers predefined corrective actions to minimize the impact of data integrity attacks on the regulation market and system stability. We evaluated the proposed approach on a hydropower-integrated BESS topology, specifically analyzing the slow regulation signal (Reg A) coming from the PJM market. Our simulation results demonstrate that the proposed approach performs well in detecting data integrity attacks within the allocated time frame and also minimizes the system's transient instability during the participation of hydropower and BESS in the regulation market.

battery energy storage system↗

Software defined grid energy storage

Today, consumer battery installations are isolated, physical devices. Virtual power plants (VPPs) allow consumer devices to aggregate for grid services, but they are are vertically integrated, vendor controlled systems (e.g., Tesla’s VPP). Consumer batteries are therefore unable to participate in energy markets or other grid services outside what their vendor provides. We describe a software system that provides software control of multiple, networked battery energy storage systems in the electric grid. The system introduces two new ideas that enable flexible and dependable management of energy storage. The first is a virtual battery, which can either partition a battery or aggregate multiple batteries. The second is a reservation-based API which allows asynchronous control of batteries to meet contractual guarantees in a safe and dependable manner. Virtual batteries and a reservation-based API address the unique challenges of achieving high and efficient utilization of energy storage systems, including heterogeneity of battery systems such as varying C-rates, participation in energy markets, utility bill management systems, community resource sharing, and reliability. Using a testbed comprised of sonnen Inc. storage units installed in several homes and a lab, we demonstrate that virtualized batteries can seamlessly replace physical batteries, flexibly manage energy storage resources, isolate multiple clients using a shared battery, and create new energy storage applications.

25 ENERGY STORAGE↗

ARIES/Flatirons Facility - Hydrogen System Capability Buildout

Under the Advanced Research for Integrated Energy Systems (ARIES) initiative, NREL will build out hydrogen system capabilities at the Flatirons campus. The hydrogen infrastructure at the Flatirons campus will include a research-ready megawatt-scale electrolyzer with hydrogen compression and storage, and a fuel cell system. This hardware will support H2@Scale goals by enabling integrated systems R&D (e.g., to demonstrate grid services, energy storage, renewable hydrogen production, and innovative end-use applications). The system will be coupled with the controllable grid interface at the Flatirons campus and will be designed with flexibility to provide a testbed for integrated electrolyzer R&D, hydrogen utilization R&D, and to study the science of scaling for hydrogen energy systems.

39 EE - Hydrogen and Fuel Cell Technologies (EE-3F↗

Trust Model Utilization for Energy Grid Communication

The internet information that is used by the Energy Grid of Things requires both preventative security measures as well as surveillance measures. The preventative security measures include certificates, encryption, and all of the basic security protocols as defined by published standards. The surveillance measures include monitoring information flow activities and evaluating these messages for indications of potential security attacks. We describe in this paper the utilization of a Distributed Trust Model that was developed specifically for monitoring communication within an Energy Grid of Things. The goal for the Distributed Trust Models is to provide a level of aggregate trust that a Distributed Energy Resource Management System can meet its grid service obligations, as opposed to a detailed individual Distributed Energy Resources assessment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Providing Ancillary Services with Photovoltaic Generation in Multi- Timescale Grid Operation

With penetration levels of photovoltaic (PV) generation substantially increasing, electric power systems need more flexible resources that can provide ancillary services to mitigate the variability and uncertainty of the PV. On one hand, the increase in PV generation necessitates more flexible resources; on the other hand, because of its low operation cost, PV generation has been replacing conventional generation, which is currently the main flexible resource. Consequently, there is a trend to require renewable generation, including PV, to provide flexible ancillary services. This paper proposes a multi-timescale grid operation model considering the various control strategies of PV providing different ancillary services. Numerical case studies demonstrate that with PV providing both regulation reserve and primary frequency reserve, the system operating costs and PV curtailment will be reduced significantly. Results show that not only the system reliability can be improved but also PV profitability with PV providing more ancillary services.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Endogeneity of pedestrian survival time and emergency medical service response time: Variations across disadvantaged and non-disadvantaged communities

The Vision Zero-Safe Systems Approach prioritizes fast access to Emergency Medical Services (EMS) to improve the survivability of road users in transportation crashes, especially concerning the recent increase in pedestrian-involved crashes. Pedestrian crashes resulting in immediate or early death are considerably more severe than those taking longer. The time gap between injury and fatality is known as survival time, and it heavily relies on EMS response time. The characteristics of the crash location may be associated with EMS response and survival time. A US Department of Transportation initiative identifies communities often facing challenges. Six disadvantaged community (DAC) indicators, including economy, environment, equity, health, resilience, and transportation access, enable an analysis of how survival and EMS response times vary across DACs and non-DACs. To this end, this study created a unique and comprehensive database by linking DACs data with 2017–2021 pedestrian-involved fatal crashes. This study utilizes two-stage residual inclusion models with segmentation for DACs and non-DACs accounting for the endogenous relationship between EMS response and pedestrian survival time. The results indicate that EMS response time is higher and pedestrian survival time is lower in DACs than in non-DACs. A delayed EMS response time is associated with a greater reduction in survival time in DACs compared to non-DACs. Factors, e.g., nighttime and interstate crashes, contribute to higher EMS response time, while pedestrian drugs, driver speeding, and hit-and-run behaviors are associated with a greater reduction in survival time in DACs than non-DACs. Finally, the implications of the findings are discussed in the paper.

60 APPLIED LIFE SCIENCES↗

Anomaly Detection and Mitigation for Dynamic Frequency Regulation in Hydropower-Battery Systems: Preprint

Hydropower operators and energy storage providers are increasingly interested in participating in frequency regulation services, driven by the incentives offered by independent system operators, such as the Pennsylvania-New Jersey-Maryland Interconnection (PJM), in a competitive electricity market. This transition, however, unfolds against the backdrop of a modernizing and rapidly digitizing power grid, exposing the integrated legacy infrastructure and vulnerable communication networks to a multitude of cybersecurity threats. These evolving threats not only endanger grid operations but also have the potential to trigger cascading disruptions across the broader grid network and influence regulation markets. This work presents an approach for developing an anomaly detection and mitigation system to address cybersecurity challenges during the participation of a hydropower-integrated battery energy storage system (BESS) in a frequency regulation market. The applied anomaly detector utilizes machine learning algorithms to provide detailed classification of cyber-physical events and provide a comprehensive situation awareness to grid operators. Later, the applied mitigation system triggers predefined corrective actions to minimize the impact of data integrity attacks on the regulation market and system stability. We evaluated the proposed approach on a fully active BESS topology using the slow regulation signal (Reg A) coming from the PJM market. Our simulation results reveal that the proposed approach performs well in detecting data integrity attacks within the allocated time frame and also minimizes the system's instability and economic loss during the participation of hydropower and BESS in the regulation market.

battery energy storage system↗