Search NASA⌕ Search

SEARCH · Search NASA

Results for “shield”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Application of Stuffed Whipple Shield to Robotic Spacecraft

Protection of human life onboard the International Space Station (ISS) requires reinforced shielding of crewed modules to prevent penetration of micro-meteoroid and orbital debris (MMOD), while optimizing the necessary mass for that application. An efficient way to achieve that protection consists in combining metal plates with ceramic and Kevlar fabrics in critical areas, a configuration known as the “Stuffed Whipple Shield”. In robotic spacecraft, fuel tanks are particularly vulnerable to MMOD impacts due to their pressurized contents and thin walls. Risk assessment of the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) spacecraft using the Bumper3-Sat hypervelocity impact simulation tool demonstrated that the risk of propulsion tank damage due to MMOD particles coming from the ram direction (Launch Vehicle Adapter side) violated NASA requirements to limit the generation of orbital debris and threatened mission success. To mitigate the risk and achieve compliance, the basic configuration of the ISS Stuffed Whipple shield was scaled down and adapted to become a tank shield in the spacecraft ram direction. This paper will describe the adaptation of the ISS Stuffed Shield to a robotic spacecraft, while also comparing the effectiveness of the proposed shield design with more traditional single-wall and double-wall alternatives used in robotic spacecraft under similar conditions.

Ivonne M. Rodriguez↗

SAFETY ANALYSIS REPORT FOR PACKAGING SHIELDING & NUCLEAR CRITICALITY SAFETY COURSES DEVELOPED AND CONDUCTED BY OAK RIDGE NATIONAL LABORATORY

The US Department of Energy (DOE) Packaging Certification Program, Office of Packaging and Transportation, is offering Safety Analysis Report for Packaging (SARP) Shielding and Nuclear Criticality Safety (NCS) courses for SARP generalists and analysts. The SARP generalist course is designed for project managers, supervisors, NCS/shielding subject matter experts (SME), and SMEs in non-NCS/shielding technical areas (e.g., structural, thermal, package design) who need to improve their understanding of how NCS/shielding analyses fit into the broader spectrum of SARP documentation. The generalist course provides an overview of the regulations and guidelines for the criticality and shielding analyses included in a SARP, and it illustrates how the NCS/shielding chapters integrate with the other parts of the SARP. After course material is presented, students in the generalist course will review an actual SARP document to examine key elements of the shielding and criticality analyses. The analyst course provides detailed instructions on the radioactive material package shielding analyses and NCS evaluation fundamentals needed by analysts/practitioners, including safety analysts and/or technical reviewers, to prepare and/or review technical analyses for SARP documentation. The analyst course also provides an overview of regulations and guidelines, in addition to detailed in-class exercises associated with package shielding and NCS analyses. Analysis teams will be faced with staged SARP examples in which several important decision processes in the generation of a SARP will be demonstrated and discussed. Both courses are offered at Oak Ridge National Laboratory, and for interested students, the analyst course is offered for one hour of graduate credit (course ME-690) from the University of Nevada at Reno. An overview of the course will be provided to ensure that the NCS community is aware of the course and its intent to support the shielding and NCS aspects of packaging and transportation analyses for SARP activities.

Bowen, Douglas G.↗

Radiological Shielding Design for the Neutron Backscattering Spectrometer EMU

In this paper we present modelling and design of compact radiation shielding required for operation of the EMU instrument, located at Australia's OPAL nuclear reactor. The acceptance criteria for the shielding design were (i) safety - dose rate ≤ 3 μSv/h at external surfaces of the instrument's experimental area, (ii) floor load limit < 20 tons/m{sup 2}, (iii) low cost and (iv) for maintenance purposes 'easy access' to components of the instruments. The EMU instrument is a cold neutron backscattering spectrometer designed to measure inelastic neutron scattering. Its distinctive feature is that it has a tight elastic energy transfer resolution, of about 1 μeV. The instrument provides unique opportunities to study diffusion in complex materials, e.g. water molecules in confinement, polymers or biological molecules, particularly in the Asia-Oceania region. EMU is the first instrument located on the CG3 neutron beam line of the OPAL Neutron Guide Hall (NGH). A pre-existing evacuated neutron guide of dimensions 200 mm (height) x 50 mm (width) feeds into the shared EMU/KOOKABURRA pre-monochromator bunker shielding assembly, and its bottom cross section will be intercepted ∼200 mm further in air by the highly orientated pyrolytic graphite (HOPG) EMU pre-monochromator (take-off angles from 125.4 deg. to 148 deg.). The bunker shielding assembly for EMU also contains a beryllium filter and Focusing Guide Section D (FGD, 170 mm (height) x 50 mm (width)). To accommodate the range of take-off angles Pb cylindrical shielding blocks of radius 140 mm and 500 mm height have been designed. These blocks will be located at the section of the bunker where the neutron beam will exit towards the experimental area and they will reside on top of a hollow steel base (sides 10 mm thick), on which they move by sliding and are integrated with the tertiary shutter. The experimental area is enclosed by a concrete wall of 2.5 m height and 300 mm thickness, shared with the KOOKABURRA instrument, Gyprock Plasterboard panels with viewing windows, a wall from the Out-of-Pile Bunker and the CG3 shielding. The neutron beam enters the experimental area via the tertiary shutter, into the Focusing Guide Section C (FGC), which has an entrance guide cross-section of 158 mm (height) x 79 mm (width) and exit guide cross-section of 149 mm (height) x 85 mm (width) and is of length 816 mm. The vacuum chamber of FGC will be connected to the vacuum chamber of the Background Chopper (BC, disc of outer radius 350 mm). Focusing Guide Section B (FGB) is aligned with FGC and its vacuum shared with the BC vacuum. The FGB has an exit guide cross section of 50 mm (height) x 49 mm (width) and is of length 4046 mm, which will focus the neutron beam vertically and horizontally towards the Al window entrance (0.82 mm thickness, labelled N16) of the Scattering Tank assembly (constructed from 20 mm - 40 mm thickness stainless steel and will be under vacuum < 1 x 10{sup -3} mbar). Inside the Scattering Tank there is another section of Focusing Guide (FGA), with an exit guide cross-section of 30 mm (height) 30 mm (width) and of length 417 mm. The neutron beam exiting the FGA will be reflected by the HOPG crystal pieces of the Graphite Chopper (GC) towards the Backscattering Monochromator (BM). The reflected neutron beam will first pass through the other Al window (0.82 mm thickness, labelled N17) of the Scattering Tank and then enter into a flight tube (steel of 10 mm thickness). The BM is formed in an 1800 mm spherical radius array of Si crystal elements (0.87 mm thickness) and is oscillated by the linear motor Doppler Drive. The neutron beam will be reflected back at 180 deg. from, and focussed by the BM to reenter the Scattering Tank through the N17 Al window. It will then pass through the GC (HOPG crystals are rotated out of the way) and will reach the scattering sample of interest to the instrument end user. Also, inside the Scattering Tank there will be {sup 3}He linear position-sensitive detectors, and Analyser Arrays formed in an 1800 mm radius spherical arrays of Si crystal elements (0.87 mm thickness) glued on aluminium support frames (10 mm thickness) and span ∼160 deg. arc.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Efficacy of Lower-Body Shielding in Computed Tomography Fluoroscopy-Guided Interventions

Purpose: Computed tomography (CT) fluoroscopy-guided interventions pose relevant radiation exposure to the interventionalist. The goal of this study was to analyze the efficacy of lower-body shielding as a simple structural method for decreasing radiation dose to the interventionalist without limiting access to the patient. Material and Methods: All examinations were performed with a 128-slice dual source CT scanner (12 Multiplication-Sign 1.2-mm collimation; 120 kV; and 20, 40, 60, and 80 mAs) and an Alderson-Rando phantom. Scatter radiation was measured with an ionization chamber and a digital dosimeter at standardized positions and heights with and without a lower-body lead shield (0.5-mm lead equivalent; Kenex, Harlow, UK). Dose decreases were computed for the different points of measurement. Results: On average, lower-body shielding decreased scatter radiation by 38.2% within a 150-cm radius around the shielding. This decrease is most significant close to the gantry opening and at low heights of 50 and 100 cm above the floor with a maximum decrease of scatter radiation of 95.9% close to the scanner's isocentre. With increasing distance to the gantry opening, the effect decreased. There is almost no dose decrease effect at {>=}150 above the floor. Scatter radiation and its decrease were linearly correlated with the tube current-time product (r{sup 2} = 0.99), whereas percent scatter radiation decrease was independent of the tube current-time product. Conclusion: Lower-body shielding is an effective way to decrease radiation exposure to the interventionalist and should routinely be used in CT fluoroscopy-guided interventions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

IMRT treatment of anal cancer with a scrotal shield

The risk of sterility in males undergoing radiotherapy in the pelvic region indicates the use of a shielding device, which offers protection to the testes for patients wishing to maintain fertility. The use of such devices in the realm of intensity-modulated radiotherapy (IMRT) in the pelvic region can pose many obstacles during simulation, treatment planning, and delivery of radiotherapy. This work focuses on the development and execution of an IMRT plan for the treatment of anal cancer using a scrotal shielding device on a clinical patient. An IMRT plan was developed using Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA), using a wide array of gantry angles as well as fixed jaw and fluence editing techniques. When possible, the entire target volume was encompassed by the treatment field. When the beam was incident on the scrotal shield, the jaw was fixed to avoid the device and the collimator rotation optimized to irradiate as much of the target as possible. This technique maximizes genital sparing and allows minimal irradiation of the gonads. When this fixed-jaw technique was found to compromise adequate coverage of the target, manual fluence editing techniques were used to avoid the shielding device. Special procedures for simulation, imaging, and treatment verification were also developed. In vivo dosimetry was used to verify and ensure acceptable dose to the gonads. The combination of these techniques resulted in a highly conformal plan that spares organs and risk and avoids the genitals as well as entrance of primary radiation onto the shielding device.

61 RADIATION PROTECTION AND DOSIMETRY↗

A simulation of X-ray shielding for a superconducting electron cyclotron resonance ion source

It is generally assumed that large amounts of x-rays are emitted from the ion source of an Electron Cyclotron Resonance (ECR) instrument. The total amount of x-rays should be strictly limited to avoid the extra heat load to the cryostat of the superconducting ECR ion source, since they are partly absorbed by the cold mass into the cryostat. A simulation of x-ray shielding was carried out to determine the effective thickness of the x-ray shield needed via the use of Geant4. X-ray spectra of the 10 GHz Nanogan ECR ion source were measured as a function of the thickness variation in the x-ray shield. The experimental results were compared with Geant4 results to verify the effectiveness of the x-ray shield. Based on the validity in the case of the 10 GHz ECR ion source, the x-ray shielding results are presented by assuming the spectral temperature of the 28 GHz ECR ion source.

43 PARTICLE ACCELERATORS↗

Passive shielding effect on space profile of magnetic field emissions for wireless power transfer to vehicles

Magnetic fields emitted by wireless power transfer systems are of high importance with respect to human safety and health. Aluminum and ferrite are used in the system to reduce the fields and are termed as passive shielding. In this paper, the influence of these materials on the space profile has been investigated with the help of simulations on Comsol for the four possible geometries—no shielding, ferrite, aluminum, and full shielding. As the reflected impedance varies for the four geometries, the primary current is varied accordingly to maintain constant power transfer to the secondary side. Surrounding magnetic field plots in the vertical direction show that maxima's of the two coils for the no shielding geometry are centered at the respective coils and for the remaining three are displaced closer to each other. This closeness would lead to more effective addition of the two coil fields and an increase in the resultant field from space point of view. This closeness varies with distance in the horizontal direction and vertical gap between the coils and is explained in the paper. This paper provides a better understanding of effect of the passive shielding materials on the space nature of magnetic fields for wireless power transfer for vehicle applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-T-523: Investigation of Various MR-Compatible Shielding Materials for Direction Modulated Brachytherapy (DMBT) Tandem Applicator for Cervical Cancer Treatment

Purpose: To evaluate various shielding materials such as Gold (Au), Osmium (Os), Tantalum (Ta), and Tungsten (W) based alloys for use with a novel intensity modulation capable direction modulated brachytherapy (DMBT) tandem applicator for image guided cervical cancer HDR brachytherapy. Methods: The novel MRI-compatible DMBT tandem, made from nonmagnetic tungsten-alloy rod with diameter of 5.4 mm, has 6 symmetric peripheral holes of 1.3 mm diameter with 2.05 mm distance from the center for a high degree intensity modulation capacity. The 0.3 mm thickness of bio-compatible plastic tubing wraps the tandem. MCNPX was used for Monte Carlo simulations of the shields and the mHDR Ir-192 V2 source. MC-generated 3D dose matrices of different shielding materials of Au, Os, Ta, and W with 1 mm3 resolution were imported into an in-house-coded inverse optimization planning system to evaluate 19 clinical patient plans. Prescription dose was 15Gy. All plans were normalized to receive the same HRCTV D90. Results: In general, the plan qualities for various shielding materials were similar. The OAR D2cc for bladder was very similar for Au, Os, and Ta with 11.64±2.30Gy. For W, it was very close 11.65±2.30Gy. The sigmoid D2cc was 9.82±2.46Gy for Au and Os while it was 9.84±2.48Gy for Ta and W. The rectum D2cc was 7.44±3.06Gy for Au, 7.43±3.07Gy for Os, 7.48±3.05Gy for Ta, and 7.47±3.05Gy for W. The HRCTV D98 and V100 were very close with 16.37±1.87 Gy and 97.37±1.93 Gy, on average, respectively. Conclusion: Various MRI-compatible shielding alloys were investigated for the DMBT tandem applicator. The clinical plan qualities were not significantly different among these various alloys, however. Therefore, the candidate metals (or in combination) can be used to select best alloys for MRI image guided cervical cancer brachytherapy using the novel DMBT applicator that is capable of unprecedented level of intensity modulation.

60 APPLIED LIFE SCIENCES↗

SU-F-T-86: Electron Dosimetric Effects of Bolus and Lens Shielding in Treating Superficial Eye Lesions

Purpose: Electron therapy for the treatment of ocular lymphomas requires the lens to be shielded to prevent secondary cataracts. This work evaluates the dosimetry under a suspended eyeshield with and without bolus for low energy electron fields. Methods: Film (GafChromic EBT3) dosimetry and relative output factors were measured for 6, 8, and 10 MeV electron energies. A customized 5 cm diameter circle electron orbital cutout was constructed for a 6×6 cm applicator with a lens shield, 1 cm diameter Cerrobend cylinder with 2.2 cm length, suspended from an XV film covering the open field. Relative output factors were measured using a Scanditronix electron diode in a solid water phantom. Depth dose profiles were collected for bolus thicknesses of 0, 3, and 5 mm in solid water at a source to surface distance (SSD) of 100 cm. These measurements were repeated in a Rando phantom. Results: At 5 mm, the approximate distance of the lens from the surface of the cornea, the estimated dose in solid water under the suspended lens shield was reduced to 16%, 14%, and 13% of the unblocked dose at the same depth, for electron energies of 6, 8, and 10 MeV, respectively. Applying bolus increased estimated doses under the block to 22% for 3-mm and 32% for 5-mm thicknesses for a 6 MeV incident electron beam. This effect is reduced for higher energies where the corresponding values were 15.5% and 18% for 3-mm and 5-mm for an 8 MeV electron beam. Conclusion: The application of bolus to treat superficial eye lesions of the conjunctiva increases lens dose at a depth of 5-mm under the shielding block with decreasing electron energy. Careful selection of electron energy is needed to account for electron scatter under the lens shield with the application of bolus in order to prevent cataracts.

07 ISOTOPE AND RADIATION SOURCES↗

Biological shield design and analysis of KIPT accelerator-driven subcritical facility.

Argonne National Laboratory of the United States and Kharkov Institute of Physics and Technology of Ukraine have been collaborating on the conceptual design development of an electron accelerator-driven subcritical facility. The facility will be utilized for performing basic and applied nuclear research, producing medical isotopes, and training young nuclear specialists. This paper presents the design and analyses of the biological shield performed for the top section of the facility. The neutron source driving the subcritical assembly is generated from the interaction of a 100-kW electron beam with a natural uranium target. The electron energy is in the range of 100 to 200 MeV, and it has a uniform spatial distribution. The shield design and the associated analyses are presented including different parametric studies. In the analyses, a significant effort was dedicated to the accurate prediction of the radiation dose outside the shield boundary as a function of the shield thickness without geometrical approximations or material homogenization. The MCNPX Monte Carlo code was utilized for the transport calculation of electrons, photons, and neutrons. Weight window variance-reduction techniques were introduced, and the dose equivalent outside the shield can be calculated with reasonably good statistics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of the concrete shield compositions from the 2010 criticality accident alarm system benchmark experiments at the CEA Valduc SILENE facility

In October 2010, a series of benchmark experiments were conducted at the French Commissariat a l'Energie Atomique et aux Energies Alternatives (CEA) Valduc SILENE facility. These experiments were a joint effort between the United States Department of Energy Nuclear Criticality Safety Program and the CEA. The purpose of these experiments was to create three benchmarks for the verification and validation of radiation transport codes and evaluated nuclear data used in the analysis of criticality accident alarm systems. This series of experiments consisted of three single-pulsed experiments with the SILENE reactor. For the first experiment, the reactor was bare (unshielded), whereas in the second and third experiments, it was shielded by lead and polyethylene, respectively. The polyethylene shield of the third experiment had a cadmium liner on its internal and external surfaces, which vertically was located near the fuel region of SILENE. During each experiment, several neutron activation foils and thermoluminescent dosimeters (TLDs) were placed around the reactor. Nearly half of the foils and TLDs had additional high-density magnetite concrete, high-density barite concrete, standard concrete, and/or BoroBond shields. CEA Saclay provided all the concrete, and the US Y-12 National Security Complex provided the BoroBond. Measurement data from the experiments were published at the 2011 International Conference on Nuclear Criticality (ICNC 2011) and the 2013 Nuclear Criticality Safety Division (NCSD 2013) topical meeting. Preliminary computational results for the first experiment were presented in the ICNC 2011 paper, which showed poor agreement between the computational results and the measured values of the foils shielded by concrete. Recently the hydrogen content, boron content, and density of these concrete shields were further investigated within the constraints of the previously available data. New computational results for the first experiment are now available that show much better agreement with the measured values.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Investigation of Shielding Material in Radioactive Waste Management - 13009

In this study, various waste packages have been prepared by using different materials. Experimental work has been performed on radiation shielding for gamma and neutron radiation. Various materials were evaluated (e.g. concrete, boron, etc.) related to different application areas in radioactive waste management. Effects of addition boric compound mixtures on shielding properties of concrete have been investigated for neutron radiation. The effect of the mixture addition on the shielding properties of concrete was investigated. The results show that negative effects of boric compounds on the strength of concrete decreasing by increasing boric amounts. Shielding efficiency of prepared mixture added concrete up to 80% better than ordinary concretes for neutron radiation. The attenuation was determined theoretically by calculation and practically by using neutron dose rate measurements. In addition of dose rate measurements, strength tests were applied on test shielding materials. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Resonance Self-Shielding Using Deterministic Transport Methods with Pointwise Cross Sections (Invited) - Eugene P. Wigner Reactor Physics Award

The difficulty of predicting resonance absorption has been recognized since the birth of reactor physics. A paper published by Wigner, et al. in 1955 describes pioneering theoretical work done in 1941 to provide an estimate for the resonance absorption in heterogeneous uranium lattices. This work introduced many fundamental concepts, including the narrow resonance (NR) approximation and the Wigner rational expression for the escape probability from a fuel lump, and it established an equivalence relation for resonance absorption in homogeneous and heterogeneous systems. During the 1960's, Bondarenko proposed an approach in which resonance shielding factors are precomputed and parametrized as a function of the background cross section by using the NR approximation and equivalence theory. This provided an efficient technique for treating resonance absorption in reactor lattices. The Bondarenko method and its modern variations (e.g., certain subgroup techniques) have become the predominate method for resonance shielding calculations in reactor physics. However, this approach has several limitations, most of which are well known, such as the treatment of resonance interference effects and its reliance on homogeneous-heterogeneous equivalence theory relationships. Other limitations are more subtle and less generally recognized, such as neglecting the impact of self-shielding the multigroup (MG) elastic removal cross section and the effects of directionally dependent shielding on the total cross section. This paper and the accompanying presentation apply deterministic solutions of the continuous energy (CE) neutron transport equation to examine common approximations made in resonance methods for a uniform lattice. The calculated fine-structure spectra are used to calibrate the impact of the approximations and describe how results from CE flux solution can be incorporated in the Bondarenko self-shielding method to improve the accuracy. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Lattice Physics Calculations Using the Embedded Self-Shielding Method in Polaris, Part I: Methods and Implementation

Polaris is a 2-dimensional multigroup lattice physics capability in the SCALE code system for the analysis of light water reactor fuel designs. The goal of light water reactor lattice physics codes is to generate few-group homogenized cross sections for downstream full-core nodal diffusion calculations. Additionally, lattice physics calculations contain three primary components: the cross section processing calculation, the 2D transport calculation, and the depletion calculation. This paper summarizes the calculational methods and their implementation into Polaris, with an emphasis on implementation of the embedded self-shielding method. The accuracy of the embedded self-shielding method depends on the procedure used to generate self-shielding factors on the multigroup library. Numerical benchmarks calculations reveal that the accuracy of Polaris eigenvalue predictions is enhanced by (1) using heterogeneous unit cell models to generate the self-shielding factors on the library and (2) using self-shielding factors for within-group scattering cross section.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Genetic algorithm optimization of tin–copper graded shielding for improved plutonium safeguards measurements

Plutonium nuclear material safeguards is essential to ensure that states do not divert plutonium to clandestine nuclear weapons programs. Traditional safeguards methods rely on correlated neutron measurements. Detection systems based on organic scintillators, which are sensitive to fast neutrons and photons, are gaining support for use in safeguards applications due to increased capabilities and shorter measurement times compared to the current state-of-the-art. A drawback of organic scintillators in plutonium measurements is data throughput limitations; 241 Am builds up in plutonium samples and emits 60-keV gamma rays with a high specific activity. In this work, a genetic algorithm is used to design graded shielding made of tin and copper to attenuate the 60-keV gamma rays. The shield is designed to limit the attenuation of the higher-energy, fission photons, because fission photons can be used as a signature. The genetic algorithm optimization takes days to run, while a complete search space exploration would take years. The genetic algorithm was run for different levels of 60-keV gamma-ray attenuation, and the thickness of the required shielding layers was determined at each level. Tin–copper shielding was placed in front of an array of organic scintillation detectors for a measurement of approximately 4.5 kg of alpha-phase, weapons-grade plutonium, an AmLi source, and a 252 Cf source. We show that the shield successfully attenuated low-energy, non-fission gamma rays, which significantly improved the organic scintillator performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surrogate modeling of Monte Carlo radiation transport with convolutional neural networks for shielding optimization

Here, we present a machine learning (ML)-based surrogate model using convolutional neural networks (CNN) designed to emulate the attenuation of neutron fields as they pass through various shielding materials. This model can compute the outgoing neutron flux almost instantaneously and achieves reasonable accuracy compared to traditional Monte Carlo (MC)-based codes, which are computationally intensive. This emulator alleviates the complexity of neutron radiation transport through shielding materials by reducing the dimensionality and enables shielding optimization for a known radiation environment. This optimization process, which would have taken an unrealistic timeline due to several complex radiation transport simulations, can now be achieved in minutes, thus increasing computational capabilities in radiation shielding assessment. We demonstrate the applications of this emulator in computing effective dose rates and optimizing shielding solutions for a heavy-ion accelerator facility, such as the Facility for Rare Isotope Beams, where secondary neutrons produced via beam interactions dominate the radiation environment.

accelerator shielding↗

Role Evaluation of Active Groups in Lignin on UV-Shielding Performance

The contribution of the active groups in lignin to ultraviolet (UV)-shielding performance still remains unclear. In this study, we employed 16 lignin model compounds and theoretical calculations to ascertain the contribution of different functional groups to UV-shielding performance. These results showed that the order of UV-shielding performance on functional groups was -C=C–CHO > -C=C–COOH > -C=C–CH 2 OH > --C=C > quinone > -COOH > -OCH 3 ≈ -OH. Moreover, the synergism between the para-substituted electron-donating group -OH and the electron-withdrawing group allyl on the aromatic ring played a major role in UV-shielding performance of lignin models, whereas the additive effect of meta/ortho-substituted -OCH 3 played a secondary role. Furthermore, we found that the hydrophile–lipophile balance (HLB) value of lignin models also greatly affected the sunscreen protection factor (SPF) of lignin model-based sunscreens. A closer HLB value of lignin to 8.89 corresponded with a higher SPF of the lignin model-based sunscreen. The commercial photoprotective ingredient ethylhexyl methoxycinnamate (EHMC) and lignin models had a synergistic effect on UV-shielding performance caused by the π–π stacking interaction between the parallel-displaced stacked aromatic rings of lignin models and EHMC. Additionally, the UV irradiation test showed that these sunscreens prepared using lignin models and EHMC exhibited good photostability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Plume dynamics and shielding characteristics of nanosecond scale multiple pulse in carbon ablation

The behavior of ablated plumes produced by nanosecond scale multiple laser pulses typical for carbon ablation is studied in order to understand the plume expansion dynamics and shielding effect of plume with special interest to ionization of plumes. The patterns of a planar plume (typical for channel cutting) and an axisymmetric plume (typical for hole drilling) appear to be quite different. Ionization in carbon plume is estimated using the Saha equation. An iterative procedure is developed to determine the local equilibrium temperature affected by ionization. It is shown that though shielding due to the presence of ionized particles in carbon plume is small, the effect of ionization on plume temperature can be considerable. Shielding effect is calculated for laser pulses with different time intervals between pulses. The effects of high temperature and low density of plume are conflicting and cause shielding behavior to be nonmonotonic. It is shown that the nonmonotonic dependence of the delivered laser energy, the pulse number, and the difference in shielding characteristics between planar and axisymmetric formulations increase with the time duration between two consecutive pulses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗